SMINN's base station controllers are developed with state-of-
the-art electronic devices. They provide a high degree of
operating reliability and security.
Residential, commercial and light industry environments.
Equipped with a solid communication bus RS 485 that allows
more mounting versatility and makes them more immune to
interference.
This device meets the corresponding provisions as long as its
usage is compliant to what was envisaged. Having applied the
following regulations.
They are designed to provide the activation and movement
order to SMINN motor controllers, alarms, access control and
home automation systems, etc. They are suitable for industrial,
commercial and/or residential environments.
These devices are built using high quality materials and
components and the latest technology. They are devices that
observe the current regulations for usage in residential,
commercial and light industry environments.
USAGE RESTRICTIONS
Operation is not guaranteed when installed in different equipment than the specified one.
THE USAGE INSTRUCTIONS OF THIS DEVICE SHALL BE HANDED TO THE USER, WHO WILL
HAVE THEM IN THEIR POSSESSION. IF THEY ARE MISLAID, THE USER CAN ASK FOR A COPY
OR DOWNLOAD IT DIRECTLY FROM WWW.SMINN.COM
The manufacturer reserves the right to change the specifications of these systems as well as
this manual without prior warning. The equipment must be manipulated only by specialized
and/or skilled personnel.
WARRANTY
This product has undergone a complete TEST during its manufacturing process that guarantees
its reliability and proper operation. The manufacturer provides 24 months of warranty to the
product from the date printed in the product and against any anomaly that it may present in its
appearance or operation.
Any damage caused by third parties, natural causes (flooding, fire, lightning, etc), arising from
improper handling or installation, vandalism or any other cause non attributable to the
manufacturer will void the warranty. The warranty only covers repairs or replacement of the
damaged device.
Any expenses derived from assembling, travelling, transport, natural wear of parts, etc., and, in
general, any expenses that are not part of the repairs or replacement of the damaged element
of the system are excluded.
The installer/provider will ask the manufacturer for a RMA number or authorization for
transport of the system in warranty. Without this previous requisite, the manufacturer will not
be able neither to process nor provide warranty service.
WARNING
This product must be used in installations which has been conceived for, considering any other
as improper use. The packaging must not be dumped in the environment. Keep products,
packaging, wrapping, documentation, etc., out of the reach of children. Follow the current local,
national or European regulations. The information contained in this document may have some
mistakes that will be corrected in future editions. The manufacturer reserves the right to modify
the contents of this document or the product without any prior warning.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE)
In accordance with the European Directive 2002/96/EC about waste electrical and electronic
equipment (WEEE), the presence of this symbol (see symbol at the bottom of this text) in the
product or in the packaging, means that this article shall not be disposed in local non-classified
waste streams. It is the user’s responsibility to dispose this product taking it to a collection
point designed for waste recycling of electrical and electronic devices. The separate collection
of this product helps optimize the waste sorting and recycling of any recyclable material and
also decreases the impact on health and the environment. For more information about the
correct wasting of this product, please contact the local authority or the distributor where you
acquired this product.
CE DECLARATION OF CONFORMITY
The company ELSON SISTEMAS, S.L
Pol. Torrelarragoiti, P6-A3-1ª
48170 Zamudio - Bizkaia (SPAIN)
Declares
The product: BASE STATION CONTROLLER BXM-220
Manufactures by ELSON ELECTRÓNICA, S.A.
Under the trademark: SMINN
For use in: Residential, Commercial or light industry
enviroments.
This device meets the provisions as long as its usage is compilant to what
was envisaged, having applied the following regulations:
Telecommunications: EN 300 220-1 v1.3.1 (2000-09)
EN 300 220-1 v1.1.1 (2000-09)
Electromagnetic
compatibility: 2004-108-CE
Low Voltage 2006-95-CE
2010-01-15 Zamudio
Jose Miguel Blanco Perez
Chief Technical Officer

230
VAC
L
N
B
A
-
+
BA
-
+BA
-
+
BA
-
+
Activation signal
to the control panel
RD125 RD125 KB120
BATT
OPERATION
.
When a code from a SMINN key-tag or keypad is received, the base station controller checks
if it is already registered in the memory. If it is registered and not blocked, the relay will
activate.
.
ERASE MEMORY
.
The memory can only be erased using SMINN's programming console and knowing its PIN,
avoiding accidental or malicious erasures.
.
BLOCKING A CODE IN THE MEMORY
.
A transmitter code cannot be simply erased from the memory, but it can be blocked so it
won't work anymore. Blocking codes in the memory can only be done using a SMINN
programming console and knowing its PIN.
..
MANUAL PROGRAMMING
.
The steps to program the motor controller are detailed below.
1. Press and hold the K1 button (fig. 1-3).
2. Approach to the reader the key-tag you want to record. When the reader sends the code,
the receiver memorizes it and it will beep twice as a validation signal. Now the programming
button can be released and the memory remains open for 10 sec. to register new key-tags.
3. After 10 seconds since the last registration, the memory closes and changes into receiver
mode.
.
BACKUP COPY
.
Although the device is protected against power line disturbances and electrical surges,
it is important to keep a backup of the memory card in case of breakdown or damages caused
by external circumstances such as electric storms, theft, improper handling, etc.
.
INSTALLATION
.
SMINN's Base-Station controller is designed to be easily fixed on a wall using the supplied wall
plugs and screws. Before connecting or operating the device, the power supply switch or
differential shall be disconnected. Specialized and/or skilled personnel will do the installation,
using properly protected cable of enough gauge. Take into account that devices permanently
connected to the mains need to have an accessible connection device
(i.e. a magnetothermic switch). The wiring should be done following the instructions printed
in the serigraphy of the circuit board. Make sure that the memory is inserted and properly
configured. After programming and verifying the equipment, close the case with
the supplied top.
SMINN'S BASE STATION CONTROLLERS ARE EQUIPPED WITH A LED TO LET KNOW
IF THE DEVICE IS POWERED.
CONNECTION
.
Wiring is easy using the terminal block for three circuits.
Readers are connected using just 4 wires on the terminals 3 to 6,
with two wires for power and two for the RS485 data BUS.
.
Terminal Function Note
Power
1
2
Positive (+)
Negative (-)
Line (A)
Line (B)
Activation relay
230V AC power input
Power output to readers/keypads
Apply to the BUS RS485 line
The RS485 BUS is used in Half / Duplex mode with two wires: A and B.
All elements of the BUS must have the same connection. A wires connected to A,
and B to B (they must not be exchanged).
.
Fig.1
1. ON Led
2. Memory
3. PROG button
4. RUN (OK) LEDs /Relay
5. Radio module.
6. Relay
7. Battery connector.
8. BUS terminal block and relay.
9. 230VAC power connector
10. Fuse 0.3A
COMPONENTS
BXM-220
TECHNICAL CHARACTERISTICS
Power supply Depending on model
Energy consumption < 10 W
Communication
Encryption High security encryption
Code memorization Plug-in memory of 250 codes
Memory expansion 500 / 1000 / 2000
Wiring 4-wire (recommended shielded cable CAT5)
Max. capacity of peripherals 2 RD125 readers + 2 KB120 keyboards
Maximum distance > 200m
Watertight IP54 - (IP65 with cable glands)
Operation temp. -20ºC / +85ºC
Dimensions 185 x 145 x 65 mm
Casing ABS
BUS RS485 Half / Duplex
Normally Open contacts
3
4
5
6
7
8
9
10
Positive (+)
Negative (-) Power output for electric locks (12VDC)
GENERAL WIRING
DIRECT CONNECTION TO THE ELECTRIC LOCK
BOX M 220 230VAC
Optional cards Tarjeta de radio TRSH
Optional battery 12V - 1.3A/h (97x52x43mm)
12VDC ELECTRIC LOCK
230
VAC
L
N
B
A
-
+
OPTIONAL COMPONENTS
TRSH RADIO CARD BATTERY 12V - 1.3A/h
*Optional battery
Other Sminn Controllers manuals
Popular Controllers manuals by other brands

Honeywell
Honeywell S05 Series Product data

Bosch Thermotechnology
Bosch Thermotechnology MBC 2 manual

Emerson
Emerson Fisher 299H installation guide

Ametek
Ametek DPA1 Series Installation, operation and troubleshooting instructions

NXP Semiconductors
NXP Semiconductors MC9S12ZVH64 Reference manual

Omron
Omron E5 K-T - datasheet