Sminn BOX S 220 User manual

BOX S220
innovative in electronics
INSTRUCTION MANUAL
DESCRIPTION
BASE STATION CONTROLLER
SMINN's base station controllers are developed
with state-of-the-art electronic devices. They
provide a high degree of operating reliability and
security. Equipped with a solid communication
bus RS 485 that allows more mounting versatility
and makes them more immune to interference.
They are designed to provide the activation and
movement order to SMINN motor controllers,
alarms, access control and home automation
systems, etc. They are suitable for industrial,
commercial and/or residential environments.
These devices are built using high quality
materials and components and the latest
technology. They are devices that observe the
current regulations for usage in residential,
commercial and light industry environments.
OPERATION
When a code from a SMINN key-tag or keypad is received, the base
station controller checks if it is already registered in the memory. If it is
registered and not blocked, the relay will activate.
ERASE MEMORY
The memory can only be erased using SMINN's programming console
and knowing its PIN, avoiding accidental or malicious erasures.
BLOCKING A CODE IN THE MEMORY
A transmitter code cannot be simply erased from the memory, but it can
be blocked so it won't work anymore. Blocking codes in the memory can
only be done using a SMINN programming console and knowing its PIN.
MANUAL PROGRAMMING
The steps to program the receiver are detailed below.
1. Press and hold the K1 button (fig. 1).
2. Approach to the reader the key-tag you want to record. When the
reader sends the code, the receiver memorizes it and it will beep twice as
a validation signal.
3. Repeat this process for as many key codes you want to register in
memory.
4. Release the programming button of the receiver.
Pressing any other channel will not make any effect.
BACKUP COPY
Although the device is protected against power line disturbances and
electrical surges, it is important to keep a backup of the memory card in
case of breakdown or damages caused by external circumstances such
as electric storms, theft, improper handling, etc.
INSTALLATION
SMINN's base station controller is ready to be easily fixed on a wall using
the supplied wall plugs and screws. Before connecting or operating the
device the power supply switch or differential shall be disconnected.
Specialized and/or skilled personnel will do the installation, using
properly protected cable of enough gauge. Take into account that
devices permanently connected to the mains need to have an accessible
connection device (i.e. a magnetothermic switch). The wiring should be
done following the instructions printed in the serigraphy of the circuit
board. Make sure that the memory is inserted and properly configured.
After programming and verifying the equipment, close the case with the
supplied top.
SMINN'S BASE STATION MOTOR CONTROLLERS INCLUDE A LIGHT
SIGNAL TO KNOW IF THE EQUIPMENT IS POWERED.
CONNECTION
Wiring is easy using the terminal block for three circuits. Readers are
connected using just 4 wires on the terminals 3 to 6. 2 of them are for
power and the other two for the RS485 data bus.
Terminal Function Note
1
2
3 Positive (+)
4 Negative (-)
5 Line (A)
6 Line (B)
7
8 Activation relay
9
The RS485 BUS is used in Half / Duplex mode with two wires: A and B.
All elements of the BUS must have the same connection. A wires
connected to A, and B to B (they must not be exchanged).
Power
Power input at 230 V or 12/24 AC / DC
(depending on model)
Power output to readers/keypads
Apply to the BUS RS485 line
(1) 12/24 V AC/DC
ti dependingop onal mod
230 VAC
(1)
N
RUN K1
OK
RD125 RD125 KB120
Activation signal to the control panel
FUS. 0.3A
3
+ A B
NAC NC
-
4 5 6 7 8 9
+
A
B
-
L
Rev. 1614

T. 944 525 120+34
www. sminn.com
info@sminn.com
Pol. Torrelarragoiti, P6 A3 - 1ª
48170 Zamudio Bizkaia
innovative in electronics
CE DECLARATION OF CONFORMITY
The company ELSON SISTEMAS, S.L
Pol. Torrelarragoiti, P6-A3-1ª
48170 Zamudio - Bizkaia (SPAIN)
Declares
The product: BASE STATION CONTROLLER BXS-220
Manufactures by ELSON ELECTRÓNICA, S.A.
Under the trademark: SMINN
For use in: Residential, Commercial or light industry
enviroments.
This device meets the provisions contained in the article 3 of the
R&TTE 1999/05/CE Regulation, as long as its usage is compliant to
what was envisaged, having applied the following regulations:
Electromagnetic EN 301489-1 v1.3.1 (2001-09)
compatibility: EN 301489-1 v1.3.1 (2001-11)
Low Voltage EN 60730-1: 2000
2010-03-30 Zamudio
Jose Miguel Blanco Perez
Chief Technical Officer
USAGE RESTRICTIONS
Operation is not guaranteed when installed in different equipment than
the specified one.
THE USAGE INSTRUCTIONS OF THIS DEVICE SHALL BE HANDED TO
THE USER, WHO WILL HAVE THEM IN THEIR POSSESSION. IF THEY ARE
MISLAID, THE USER CAN ASK FOR A COPY OR DOWNLOAD IT
DIRECTLY FROM WWW.SMINN.COM
The manufacturer reserves the right to change the specifications of these
systems as well as this manual without prior warning. The equipment
must be manipulated only by specialized and/or skilled personnel.
WARRANTY
This product has undergone a complete TEST during its manufacturing
process that guarantees its reliability and proper operation. The
manufacturer provides 24 months of warranty to the product from the
date printed in the product and against any anomaly that it may present
in its appearance or operation.Any damage caused by third parties,
natural causes (flooding, fire, lightning, etc), arising from improper
handling or installation, vandalism or any other cause non attributable to
the manufacturer will void the warranty. The warranty only covers repairs
or replacement of the damaged device. E Any expenses derived from
assembling, travelling, transport, natural wear of parts, etc., and, in
general, any expenses that are not part of the repairs or replacement of
the damaged element of the system are excluded. The installer/provider
will ask the manufacturer for a RMA number or authorization for
transport of the system in warranty. Without this previous requisite, the
manufacturer will not be able neither to process nor provide warranty
service.
WARNING
This product must be used in installations which has been conceived for,
considering any other as improper use. The packaging must not be
dumped in the environment. Keep products, packaging, wrapping,
documentation, etc., out of the reach of children. Follow the current local,
national or European regulations. The information contained in this
document may have some mistakes that will be corrected in future
editions. The manufacturer reserves the right to modify the contents of
this document or the product without any prior warning.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE)
In accordance with the European Directive 2002/96/EC about waste
electrical and electronic equipment (WEEE), the presence of this symbol
(see symbol at the bottom of this text) in the product or in the
packaging, means that this article shall not be disposed in local non-
classified waste streams. It is the user’s responsibility to dispose this
product taking it to a collection point designed for waste recycling of
electrical and electronic devices. The separate collection of this product
helps optimize the waste sorting and recycling of any recyclable material
and also decreases the impact on health and the environment. For more
information about the correct wasting of this product, please contact the
local authority or the distributor where you acquired this product.
ON Led1.
PROG button
2.
LED RUN (OK)/Relay3.
BUS terminal block and relay4.
Buzzer5.
Fuse6.
Power terminals7.
Plug-in memory socket8.
TECHNICAL CHARACTERISTICS
Power Depending on model
Energy consumption < 5 W
Communication BUS RS485 Half / Duplex
Encryption High security encryption
Code memorization Plug-in memory of 250 codes
Memory expansion 500 / 1000 / 2000
Wiring 4-wire (recommended shielded cable CAT5)
Max. capacity of peripherals 2 readers RD 125 + 2 keypads KB 120
Maximum distance > 200 m
Watertight Ip54 - (IP66 with cable glands)
Operation temp. -20ºC - +85º C
Dimensions 100 mm x 130 mm x 50 mm
Casing ABS
BOX S 220 230 V AC
BOX S 224 12/24 AC/DC
1
2
3
45
6
7
8
FUS. 0.3A
BXS-220
Fig. 1
COMPONENTS
SPAIN
This manual suits for next models
9
Other Sminn Controllers manuals