SoClean 2 User manual

User Manual
SoClean.com
SoClean 2 Automated PAP Disinfecting System
Guide d’utilisation
Système de désinfection PPC automatique SoClean 2
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 1A000330-11_Rev B-SC1200 Manual_CA_040720.indd 1 4/28/20 1:23 PM4/28/20 1:23 PM

ENGLISH ..........................................................................................................I
FRANÇAIS ...................................................................................................... II
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 2A000330-11_Rev B-SC1200 Manual_CA_040720.indd 2 4/28/20 1:23 PM4/28/20 1:23 PM

ENGLISH
User Manual ISoClean 2 Automated PAP Disinfecting System
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 3A000330-11_Rev B-SC1200 Manual_CA_040720.indd 3 4/28/20 1:23 PM4/28/20 1:23 PM

Thank You!
*See Indication of use, Cautions and Specications.
†Data on le.
Thank you for purchasing the
SoClean 2 PAP disinfecting system.*
This manual contains a product overview and key
set-up instructions. Once connected, you’ll find that daily
disinfecting of your PAP equipment has never been easier.
The SoClean patented process destroys 99.9% of PAP
germs, bacteria and other pathogens without the need
for water or harsh chemicals.†The SoClean 2 allows you
to use disinfected PAP equipment daily, without the need
to disconnect.
While the SoClean is designed to fit many PAP models,
some models require additional parts or set-up steps.
If you do not currently have these parts, they can be
purchased from SoClean or an authorised reseller.
See SoClean.com for PAP model details.
SoClean is committed to developing innovative and safe
ways to improve the health and well-being of PAP users.
Please feel free to contact us with any questions you
may have at SoClean.com/contact.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 4A000330-11_Rev B-SC1200 Manual_CA_040720.indd 4 4/28/20 1:23 PM4/28/20 1:23 PM

Thank You!
TABLE OF CONTENTS
INDICATIONS FOR USE, CONTRAINDICATIONS,
SPECIFICATIONS, WARNINGS AND CAUTIONS 2
YOUR HEALTH AND OZONE SAFETY 4
CLASSIFICATION, MANUFACTURER SYMBOLS AND FCC NOTICE 5
INCLUDED WITH YOUR SOCLEAN 2 6
SOCLEAN 2 CONTROL PANEL 10
KEY PAP PARTS 12
CONNECTION STEPS 14
SUPPORTED PAP MACHINES AND ADAPTERS 17
SET LANGUAGE, CLOCK AND CYCLE SCHEDULE 18
USING YOUR SOCLEAN 2 22
CARE AND MAINTENANCE OF YOUR SOCLEAN 2 24
FAQS24
SoClean.com 800-916-4577
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 5A000330-11_Rev B-SC1200 Manual_CA_040720.indd 5 4/28/20 1:23 PM4/28/20 1:23 PM

2 | INDICATIONS FOR USE, CONTRAINDICATIONS, SPECIFICATIONS, WARNINGS AND CAUTIONS2 |
*DISCLAIMER: SoClean does not represent through the use of the terms disinfect, disinfectant or disinfection
herein, or in other documentation, a kill rate of more than 99.9% of germs and bacteria in PAP equipment.
†Data on le.
Specifications:
INDICATIONS FOR USE, CONTRAINDICATIONS,
SPECIFICATIONS, WARNINGS AND CAUTIONS
Read this User Manual before operating
the equipment.
Use this product only in the manner described in this User
Manual. If the equipment is used in a manner not specified
by the manufacturer, the safety protection provided by the
equipment may be impaired.
Environmental characteristics:
Operating: 10°C to 38°C (50°F to 100°F),
15% to 70% humidity
Ozone concentration:
When operated in a 11.6 m2room with 2.4
metre-high ceilings, the average ambient ozone
concentration in the room over the operating
cycle is < 0.05 parts per million (PPM).†
Electrical characteristics:
AC adapter input: AC 100~240V, 50/60HZ, 0.5A
AC adapter output: DC 12V, 1.5A max.
Power consumption: 18W max.
Physical characteristics:
Dimensions: 200 x 184 x 225 mm
Weight: 2.5 kg
Cord length: 142 cm
Storage and transport conditions:
-20°C to +55°C (-4°F to 131°F),
15% to 70% humidity
Indications for use: The SoClean 2 is a general Positive
Airway Pressure (PAP) disinfecting device and is intended
to be used in the home. An individual who uses Positive
Airway Pressure (PAP) equipment can use the SoClean 2 to
destroy 99.9% of germs and bacteria and other pathogens
on PAP equipment, or when the user wants the added
benefit of thorough PAP system disinfection.*†
The SoClean 2 attaches to a PAP machine and runs
daily while the mask is inside the SoClean Chamber. The
SoClean 2 does not need to be disconnected before using
your PAP machine.
Contraindications for use: Persons with underlying lung
diseases, such as asthma and chronic obstructive pulmonary
disease (also known as COPD, which includes emphysema
and chronic bronchitis), and those with cardiovascular
disease may be sensitive to ozone and should consult with
their physician before using this product.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 2A000330-11_Rev B-SC1200 Manual_CA_040720.indd 2 4/28/20 1:23 PM4/28/20 1:23 PM

ENG | 3
WARNING: Do not use a fragrant oil in the water
reservoir or highly fragrant soaps to wash the sleep
equipment when using the SoClean 2.
WARNING: Discontinue use if acne or a rash
develops along the mask contact line and call SoClean
customer care.
WARNING:
Ensure the correct clock time and cycle
start time are set on your SoClean 2 before using
your PAP machine. Pay particular attention to the
AM/PM setting if using the 12-hr mode. Failure to do
so may result in the SoClean 2 device operating at an
unexpected time.
WARNING:
In the event of loss of power to your
home or the SoClean 2, ensure the correct clock time
and daily start time are set on the SoClean 2 before
using your PAP machine. Failure to do so may result
in the SoClean 2 device operating at an unexpected
time.
WARNING:
Do not physically alter the Hose Detect
Switches on your SoClean 2 device. Inspect the
Hose Detect Switches regularly for damage or
inability to move up/down. Failure of the Hose
Detect Switches on your SoClean 2 may result in
the SoClean operating at an unexpected time.
WARNING:
Keep away from water sources including
rain, bathtubs, sinks and pools. To clean, wipe with a
damp cloth. Do not submerge the SoClean 2 device
in liquid or use chemical cleaners.
WARNING:
Keep away from children. Do not place
any living thing inside the Chamber during use.
WARNING:
Do not inhale from the Injection Hose or
the Injection Hose outlet on the back of the device.
WARNING:
Only rest the flexible section of the PAP
Hose, not the rigid connector, in the Hose Detect Slot.
WARNING:
Do not breathe through your PAP mask
if the SoClean 2 is operating a disinfecting cycle.
WARNING:
Do not use in explosive air environments,
near gas vapours or other flammables, etc. Do not
place any flammable or ignitable items on top of the
SoClean 2.
WARNING: Keep the SoClean 2 Lid closed until the
green status light illuminates (approximately two hours
after completion of the disinfecting cycle).
WARNING: Do not remove gasket from the Hose
Detect Switch Slot.
CAUTION: The Lid Gasket is removable. Ensure that
the Lid Gasket is installed properly before operating a
disinfecting cycle.
WARNING: Do not dismantle the SoClean 2.
CAUTION: Do not place Neutralizing Pre-wash
in the SoClean Chamber or PAP reservoir.
Neutralizing Pre-wash is for cleaning your PAP
equipment only.
CAUTION: Please ensure that the black Injection
Hose from the back of the SoClean 2 is connected to
your PAP before operating your SoClean 2 device.
WARNING: If a strong ozone odor is detected when
the SoClean 2 is operating, turn the SoClean 2 off
by disconnecting the AC power adapter and contact
customer care.
WARNING: Do not route your PAP Hose through
both Hose Detect Slots while or after using your
PAP. This may result in the SoClean 2 device
running at an unexpected time.
WARNING: Remove clear outer wrapper and blue
tape from Cartridge Filter.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 3A000330-11_Rev B-SC1200 Manual_CA_040720.indd 3 4/28/20 1:23 PM4/28/20 1:23 PM

4 |4 | YOUR HEALTH AND OZONE SAFETY/CLASSIFICATION, MANUFACTURER, SYMBOLS AND FCC NOTICE
YOUR HEALTH AND OZONE SAFETY
• Ozone, the triatomic form of oxygen (O3), is known
as activated oxygen.
• Ozone is an effective, invisible disinfectant.
• The SoClean 2 uses ozone to disinfect Positive Airway
Pressure (PAP) equipment; ozone contacts the PAP
equipment only, not the user.
• The SoClean 2 is designed to produce only enough
ozone for effective disinfection of your PAP equipment.
• While breathing large amounts of ozone can irritate
breathing passages of humans, following the
instructions for use ensures that SoClean 2 users
will not breathe in large amounts of ozone.
• Ozone quickly dissipates in the atmosphere. If you
accidentally interrupt the cycle and release ozone by
opening the SoClean Chamber before the end of the
cycle, simply step away from the SoClean 2 to avoid
unintended exposure.
• The smell of ozone is detectable at low concentrations
by some people. The scent of ozone is similar to a
sweet chlorine-like smell.
• If you smell ozone and believe the SoClean 2 device
is not operating correctly, disconnect the power to the
device, step away from the SoClean 2 and contact
SoClean customer care.
• Ozone is a gaseous disinfectant that naturally breaks
down after it is generated. The SoClean is designed
to safely contain ozone within the system and has a
catalyst Cartridge Filter inside the SoClean Chamber to
convert ozone back to oxygen.
WARNING: If a strong ozone odor is detected when
the SoClean 2 is operating, turn the SoClean 2 off
by disconnecting the AC power adapter and contact
SoClean customer care.
WARNING: Discontinue use if acne or a rash
develops along the mask contact line and call
SoClean customer care.
Contraindications for Use: Persons with
underlying lung diseases, such as asthma and chronic
obstructive pulmonary disease (also known as COPD,
which includes emphysema and chronic bronchitis) and
those with cardiovascular disease may be sensitive to
ozone and should consult with their physician before
using this product.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 4A000330-11_Rev B-SC1200 Manual_CA_040720.indd 4 4/28/20 1:23 PM4/28/20 1:23 PM

ENG | 5
FCC Notice
Please note that changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 18 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
CLASSIFICATION, MANUFACTURER, SYMBOLS & FCC NOTICE
Classification
Health Canada Device License Number 100197, Device Classification: Class 2
Designed by and Manufactured for:
SoClean, Inc., 12 Vose Farm Road, Peterborough, New Hampshire 03458 USA
Waste Electrical and Electronic Equipment (WEEE).
It is the responsibility of the end user to dispose
of this equipment at a designated collection point.
Not made with
natural rubber latex
Symbols
Serial number
Catalogue
number
Consult
manual
Date of
manufacture
Do not use
if package
is damaged.
Manufacturer
JDI Electronics Factory
Sima Industrial Zone, Sima Village, Changping Town,
Dongguan City, Guangdong Province, China 523570
Federal
Communications
Commission
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 5A000330-11_Rev B-SC1200 Manual_CA_040720.indd 5 4/28/20 1:23 PM4/28/20 1:23 PM

6 | INCLUDED WITH YOUR SOCLEAN 2
Number Part name SKU Description
1Removable
Hose Slot Plug PN1214
This allows you to set up the SoClean 2 device on either the right or
left side of your PAP machine. Place this plug in the Hose Slot that
you don’t use.
2SoClean
Chamber N/A Place your mask in here when you wake up. Close the Lid to ensure
that the daily automated disinfecting cycle runs.
3 Lid Gasket PN1215 Ensures a tight seal around the SoClean Chamber when the SoClean
2 Lid is closed. Do not close the Lid without this part in place.
4 SoClean Lid N/A Close the Lid after you place your mask in the SoClean Chamber to
ensure that the cycle occurs.
5 Cartridge Filter PN1207UNI
This Cartridge Filter converts ozone back into normal oxygen.
Remove outer plastic wrapper and blue tape prior to
installation. You can repurchase the Filter along with the Check
Valve as part of the Cartridge Filter Kit.
6Hose Detect
Switch N/A
The Hose Detect Switch detects when the SoClean 2 is configured
for operation by detecting the presence of the hose in the Hose Slot
when the Lid is closed. If no hose is detected, the SoClean 2 will
not run a cycle. Hose Detect Switch operation can be inspected
by gently pushing down and releasing the grey plastic switch and
hearing an audible click. The switch should move freely down and up
when pressed gently.
7Neutralizing
Pre-wash
PN1101
1.5 oz.
The Neutralizing Pre-wash removes any material or odor that could
react with ozone. Wash your PAP equipment following the PAP
manufacturer’s instructions before connecting the SoClean 2 device,
or when you receive a new mask, hose or reservoir.
INCLUDED WITH YOUR SOCLEAN 2
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 6A000330-11_Rev B-SC1200 Manual_CA_040720.indd 6 4/28/20 1:23 PM4/28/20 1:23 PM

ENG | 7
1
2
34
5
7
6
1.5 oz.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 7A000330-11_Rev B-SC1200 Manual_CA_040720.indd 7 4/28/20 1:23 PM4/28/20 1:23 PM

8 | INCLUDED WITH YOUR SOCLEAN 2
Number Part name SKU Description
8 Control panel N/A Buttons, display and cycle light indicator for SoClean
functions. See page 10 for details.
9Injection Hose
A and B PN1104.12 The Injection Hose A and B carries ozone from the SoClean
device to the PAP machine. See page 16.
10 Check Valve PN1207UNI
This item comes pre-installed into the Injection Hose. It is a
one-way Check Valve that prevents water in your humidifier
reservoir from backing up and entering your SoClean 2 device.
If you can see water in this clear tube, replace the Check Valve
assembly immediately. You can repurchase it along with the
Cartridge Filter as part of the Cartridge Filter Kit.
11 Injection Fitting
PN1106 (with
humidifier reservoir)
PN1116 (without
humidifier reservoir -
not included)
Connects the Injection Hose A and B to your PAP machine.
See page 15.
12 AC adapter PN1222 Supplies power to your SoClean 2. See page 16.
INCLUDED WITH YOUR SOCLEAN 2
Replacement Parts
WARNING: Please purchase your Cartridge Filter Kits from SoClean®only. Authentic Cartridge Filter Kits can be purchased from SoClean via multiple online
marketplaces, such as Amazon®and eBay®, in addition to SoClean.com. However, please conrm that the seller of your Cartridge Filter Kit is SoClean, and
not any other seller, to ensure the authenticity of your Cartridge Filter Kit. SoClean has discovered counterfeit Cartridge Filter Kits being sold, particularly on
Amazon®and eBay®, with Check Valves and Filters that leak and can cause damage to your SoClean machine or to your property due to water leakage from the
counterfeit Check Valves. Please contact SoClean immediately if you have had any issues with your Cartridge Filter Kit. Amazon®is a registered trademark owned
by Amazon Technologies, Inc. eBay®is a registered trademark owned by eBay, Inc. SoClean®is a registered trademark owned by SoClean, Inc.
You will replace some SoClean parts regularly due to normal wear
and usage. A message appears on your SoClean after a certain
amount of use (typically around six months) as a reminder to
replace the Cartridge Filter and Check Valve. These two parts are
ordered as a set called the Cartridge Filter Kit (PN1207UNI).
The Neutralizing Pre-wash (PN1101.8) is also available for
purchase if you run out. Follow your PAP manufacturer’s
instructions for cleaning your PAP equipment.
To reorder supplies, contact your authorised reseller or visit
SoClean.com and search for the desired part.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 8A000330-11_Rev B-SC1200 Manual_CA_040720.indd 8 4/28/20 1:23 PM4/28/20 1:23 PM

ENG | 9
8
10
9
12
11
A
B
8Replacement Parts
PN1207UNI
PN1101.8
PN1229–Complete Tubing Kit
8 oz
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 9A000330-11_Rev B-SC1200 Manual_CA_040720.indd 9 4/28/20 1:23 PM4/28/20 1:23 PM

10 | SOCLEAN 2 CONTROL PANEL
1 2 3 4 5
6
7
8
SOCLEAN 2 CONTROL PANEL
Number Button(s)/Display Description
1 Sets the clock. See page 19.
2 Cycle run time (duration) The duration, in minutes, of the cycle. See page 20 to set this. The
default cycle run time is set to 7 minutes.
3 Current time The current time. See page 19 to set. Default time is set to12:00 a.m.
4 Daily start time The time of day when the cycle starts. See page 20 to set the schedule.
The default daily cycle start time is set to 10:00 a.m.
5Starts a cycle immediately. The scheduled cycle will still occur.
See page 21.
6Decreases (-) or increases (+) time.
WARNING:
In the event of loss of power to your home or the SoClean 2, ensure the correct clock time and daily start time are set
on the SoClean 2 before using your PAP machine. Failure to do so may result in the SoClean 2 operating at an unexpected time.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 10A000330-11_Rev B-SC1200 Manual_CA_040720.indd 10 4/28/20 1:24 PM4/28/20 1:24 PM

ENG | 11
Number Button(s)/Display Description
7 Status light
The light below the display indicates the cycle status.
See pages 19, 20 and 21 for instructions on scheduling and
manual operation. A green light indicates that the cycle is complete,
and you can remove your PAP mask from the SoClean Chamber
and use your PAP machine.
RED – The SoClean 2 is operating and generating ozone.
YELLOW – The 2-hour cycle is still active. The ozone is working
and dissipating.
GREEN – Cycle is complete. You can use your PAP machine any
time. The light turns off when you open the Lid.
8Sets daily start time. See page 20.
Changes clock between the 24-hour or 12-hour format. See page 19.
and
Messages
The SoClean 2 display panel shows messages that may require action. This list shows the messages and how to correct them:
Message What to Do
Hose not present. Cycle will not run.
Ensure that the PAP Hose is seated securely in the Hose Slot.
Check that the Removable Hose Slot Plug is seated correctly on the
other side. See page 22.
Order Filter Kit. Your Cartridge Filter has reached the end of its life based on your
use. See page 25.
Cycle in process. Do not open the Lid!
Ozone present. The SoClean 2 is performing a cycle. This takes
approximately 2 hours. The green cycle indicator light means that
it is complete. You can now open the Lid, take out your mask and
use your PAP machine.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 11A000330-11_Rev B-SC1200 Manual_CA_040720.indd 11 4/28/20 1:24 PM4/28/20 1:24 PM

12 | KEY PAP PARTS
KEY PAP PARTS
The SoClean 2 device is designed to connect permanently
to your PAP machine and enable operation of either
product.
The SoClean 2 device connects to most PAP machines,
using the standard included parts. This section describes
key parts of your PAP machine in the connection
procedure.
Some PAP machines have features that require additional
steps or parts. Adapters required for SoClean 2 to function
with your PAP contain appropriate instructions. See page 17
for a list of available adapters for specific PAP machines.
See SoClean.com for additional instructions for specific
PAP machines.
The figure on the next page shows a generic representation
of these key parts that are referenced in the SoClean 2
connection procedures. These are only representations:
your actual PAP machine can look different from these
drawings. Review the documentation that came with your
PAP machine for a better idea of what these parts look like
or call SoClean customer care.
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 12A000330-11_Rev B-SC1200 Manual_CA_040720.indd 12 4/28/20 1:24 PM4/28/20 1:24 PM

ENG | 13
Humidifier Open humidifier
Reservoir*
PAP machine
*Reservoir contains water
and typically can be removed.
Mask
(Full, small,
nasal pillows)
PAP hose
Mask hose
Heat plate
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 13A000330-11_Rev B-SC1200 Manual_CA_040720.indd 13 4/28/20 1:24 PM4/28/20 1:24 PM

14 | CONNECTION STEPS
CONNECTION STEPS
1. Pre-wash PAP equipment
Disconnect your PAP mask, hose and reservoir
from the PAP machine.
Use two capfuls of the included Neutralizing
Pre-wash with 4 litres (1 gallon) of water to wash
your PAP equipment (mask, hose and reservoir),
according to the manufacturer’s instructions
(Figure 1).
Rinse thoroughly with clean water.
Reinsert the reservoir (if used) into the PAP machine.
Do not reattach the hose or mask yet.
After following these steps, your SoClean 2 will disinfect
your PAP machine daily without disconnecting. Before you
disconnect your PAP machine to wash the parts, look at
where the PAP Hose is connected. You will reconnect the
SoClean Injection Fitting to the same location.
Figure 1. Disassemble and wash PAP equipment
CAUTION: Do not place Neutralizing Pre-wash in
the SoClean 2 Chamber or PAP reservoir. Neutralizing
Pre-wash is for cleaning your PAP equipment only.
Please note, SoClean devices do not replace proper
cleaning and maintenance of the PAP device according
to the manufacturer’s instructions
1.5 oz
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 14A000330-11_Rev B-SC1200 Manual_CA_040720.indd 14 4/28/20 1:24 PM4/28/20 1:24 PM

ENG | 15
2. Using an adapter
If your PAP machine requires an adapter, see adapter
instructions for set-up and proceed to Step 5.
3. Connect the Injection Fitting
The Injection Fitting connects the SoClean 2 to your PAP
machine. Once installed, you do not need to disconnect
the Injection Fitting to use your PAP. The SoClean 2
is intended to stay continuously connected to your PAP
machine.
Note: Your PAP reservoir model may require additional
configuration procedures or an adapter. If you have
difficulty with the steps in this guide, contact SoClean
customer care.
With humidifier:
1. Position the Injection Fitting onto the port of
your humidifier (where your PAP Hose was
connected), allowing the smaller Injection Hose B
to enter into the reservoir (Figure 2). The end of the
tubing should be positioned over the heat plate.
2. If necessary, carefully trim the Injection Hose B
in increments until it is the correct length, and
over the heat plate.
Injection
Fitting
Figure 2. Connect the Injection Fitting
For additional help in connecting to your specific
machine, please visit our support pages at:
SoClean.com
Injection
Hose B
Injection
Hose A
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 15A000330-11_Rev B-SC1200 Manual_CA_040720.indd 15 4/28/20 1:24 PM4/28/20 1:24 PM

16 | CONNECTION STEPS/SUPPORTED PAP MACHINES AND ADAPTERS
Injection Fitting
(hose goes to
SoClean 2)
PAP Hose
(goes to mask)
Without humidifier:
1. Pull off the small Injection Hose B from the inside of
the Injection Fitting.
Note: If you are having difficulty disconnecting Injection
Hose B, you may cut the tubing as close to the Injection
Fitting as possible.
2. Attach the Injection Fitting directly to your PAP machine.
3. Reconnect your PAP Hose to the end of the
Injection Fitting.
CAUTION: Please ensure that the black Injection Hose
from the back of the SoClean 2 is connected to your PAP
before operating your SoClean 2.
Note: If you are having difficulty connecting to your PAP, an
additional part may be necessary. Contact SoClean.com.
4. Connect the PAP Hose
Regardless of your humidifier, you can now connect
your PAP Hose to the end of the Injection Fitting, which
is connected to your PAP machine (Figure 3).
5. Connect power
Plug the AC adapter into the connector marked DC 12V,
1.5A on the back of the SoClean 2. The AC adapter
should be plugged into a wall outlet that is easy to access
and observe (Figure 4).
WARNING:
In the event of loss of power to your home or
the SoClean 2, ensure the correct clock time and daily
start time are set on the SoClean 2 before using your PAP
machine. Failure to do so may result in the SoClean 2
device operating at an unexpected time.
6. Reconnect PAP equipment
You can now reattach the mask to the end of the PAP Hose.
Figure 3. Connect PAP Hose to Injection Fitting
Figure 4. Connect AC power
A000330-11_Rev B-SC1200 Manual_CA_040720.indd 16A000330-11_Rev B-SC1200 Manual_CA_040720.indd 16 4/28/20 1:24 PM4/28/20 1:24 PM
Other manuals for 2
5
Table of contents
Languages:
Other SoClean Cleaning Equipment manuals