Quick reference guide
Electronic three-phase energy meter
for DIN railmount, with MID confirmation
and ModBus interface.
Please note
This document is only a quick reference guide and does not handle every function. The complete
users guide is available at: www.kdk-dornscheidt.de
Information for your safety
This Quick Start Guide does not contain all applicable safety regulations for meter operation. Due to
extraordinary operating conditions as well as local rules or regulations, it may be necessary to take
further safety measures.
Please Note
Installation and operation of the device described in this manual may only be performed by quali-
ed personnel. Only persons who are authorized to install, connect and use this device, who have
proper knowledge about labeling and grounding electrical equipment and circuits, and can do so in
accordance with local (safety) regulations, are considered to be qualied personnel in this manual.
Attention
The housing is sealed, do not open the meter! No warranty if the housing is opened or
the seal is removed. Please check that all cables are free from mechanical stress after
assembly.
Dimensions (mm)
Width: 70.0 mm
Height with cover: 140.0 mm
Height without cover: 92.4 mm
Depth: 63.0 mm
For a complete overview of all of the display values available in the manual mode, please refer to
the technical descriptions in the download section at www.kdk-dornscheidt.de
Changing the Modbus address by using the touch panel keys on the meter
1. Use the left arrow key to scroll through the menu until “addr 001” is displayed
2. Press both arrow buttons for 5 sec to change the address - indicator blinks once when change
mode is active
3. Increase with the right arrow key address value until the desired address is displayed
4. To exit the edit mode, press again both buttons for 5 sec
5. Leaving the change mode is conrmed by a ashing of the display
6. If this conrmation is not done, the device is still in change mode - try conrmation again
7. Check the address setting by doing step 1)
Attention
Measurement for billing purpose only with MID conrmed meters.
Example for MID labeling:
For further requests regarding Solar-Log™ or meter conguration inside Solar-Log™ please contact:
[email protected], or: +49 74 28 - 94 18 - 660
For further requests regarding the PRO meter please contact:
[email protected], or: 02244 / 919940
V1.1
Achtung: ZuVerrechnungszweckendürfennurZählermit
MID–Konformitätserklärungverwendetwerden.

BeispielfürdieMIDKennzeichnung:
BeiRückfragenzumSolarLog™,oderderKonguraondesZählersimSolarLog™
wendenSiesichbiean:support@solarlog.com,oder:07428/9418660

BeiRückfragenzumZählerwendenSiesichbiean:info@kdkdornscheidt.com,
oder:02244/919940
V1.1
Kurzanleitung:
InformaonzuIhrereigenenSicherheit:
DieseKurzanleitungenthältnichtallefürdenBetriebdesZählersgeltenden
Sicherheitsvorschrien.EskannaufGrundbesondererBetriebsbedingungen,örtlichenVorschrienoder
Verordnungennotwendigsein,weitereMaßnahmenzuergreifen.
QualiziertesPersonal:
DerZählerdarfnurvonqualiziertemFachpersonalinstalliertundangeschlossenwerden.Esgeltenjene
Personenalsqualiziert,diezugelassensind,Geräte,SystemeundStromkreiseentsprechendderSicher
heitsnormenundVerordnungeninBetriebzusetzen,einzuschalten,zuerdenundzumarkieren.
Abmessungen(mm):

Breite:   70mm
Höhem.Abdeckung:140mm
Höheo.Abdeckung:92,4mm
Tiefe:   63mm
Achtung:
DasZählergehäuseistversiegelt,derZählerdarfnichtgeönetwerden.
BeiÖnungdesZählersoderZerstörungderSiegelerlischtderGaraneanspruch.

BiebeachtenSie:
BeidiesemDokumenthandeltessichlediglichumeineKurzbeschreibung,in
dernichtaufalleFunkonenderGeräteeingegangenwerdenkann.
EineausführlicheBeschreibungstehtIhnenaufwww.kdkdornscheidt.dezur
Verfügung.
ElektronischerDrehstromzähler
fürDINSchienenmontage
mitMIDKonformitätserklärung
mitModBusSchnistelle
M 15 0122
Solare Datensysteme GmbH • www.solar-log.com • Subject to change without notice | EN | 11.2015 | Version 1.2
V1.12
Aenon: MeasurementforbillingpurposeonlywithMID
conrmedmeters.

ExampleforMIDlabeling:
ForfurtherrequestsregardingSolarLog™,ormeterconguraoninsideSolarLog™
pleaseconsider:support@solar‐log.com,or:07428/9418660

ForfurtherrequestsregardingthePROmeterpleaseconsider:
info@kdk‐dornscheidt.com,or:02244/919940
V1.12
Quickreferenceguide:
Informa�onforyoursafety:
Installa�onandopera�onofthedevicedescribedinthismanualmayonlybeperformedbyqualiedper‐
sonnel.Onlypeoplethatareauthorizedtoinstall,connectandusethisdevice,whohaveproperknow‐
ledgeaboutlabelingandgroundingelectricalequipmentandcircuitsandcandosoinaccordancewith
local(safety)regula�ons,areconsideredqualiedpersonnelinthismanual.
Dimensions(mm):

Width:   70mm
Heightwithcover: 140mm
Heightwithoutcover:92,4mm
Depth:  63mm
Aenon:
Caseissealed,donotopenthemeter!Nowarrantyifcaseisopened
orsealisremoved.

Electronicthreephaseenergymeter
forDINrailmount,withMIDconrmaon
andModBusinterface.
Pleasenote:Thisdocumentisonlyaquickreferenceguideanddoesnothandleevery
func�on.Thecompleteusersguideisavailableat:www.kdk‐dornscheidt.de
Solar-Log™ PRO380 connection assignments (only RS485)
As consumption meter (bi-directional): OUT = connection to the grid – IN = connection to the house/plant
As battery meter (bi-directional): IN = connection to the grid – OUT = connection to the battery
Please note that only the Solar-Log™ Pro 380 can operate on the RS485 interface.
It is not possible to combine the operation with other components.
If the meter is the last device on the bus, it has to be terminated at connection block 22 and 23 with
a resistor (120 ohm / 0.25 W).
All display values of the meter
Change the meter from the automatically rotating display to the manual display by pressing the
keys. Pressing on the keys here allows all of the available display values to be accessed in sequence.
If no keys are pressed after a short time, the meter reverts back to the automatic display mode.
Data shown in the automatic scroll sequence:
Indicator for energy direction per phase 1 2 3
r = Reverse F = Forward
Active energy (forward) in KWh (OBIS: 1.8.0)
Accumulating
Active energy (reverse) in KWh (OBIS: 2.8.0)
Accumulating
Current output (total)
Meter type: PRO380, 100A
Connection diagram
Connection diagram for dierent operating modes
Solar-Log™ PRO380 (RS485 or S0) connection assignments
The meter connections are labeled IN (bottom) and OUT (top)
As consumption or sub-consumer meter: Connection to the grid (IN) – connection for appliances (OUT)
As inverter /production meter: Connection for the production (IN) – connection to the grid (OUT)
Technical data
Nominal voltage 230 / 400 V AC
Current 0.25 - 5(100) A
Frequency 50 Hz
Measurement Active energy (A+, A-), reverse lock
Accuracy class B
Power consumption < 10 VA - < 2 W
Start-up current 20 mA
Width 4 TE (70 mm)
Pulse Output LED 10,000 Imp/kWh, 2,5 ms
S0–pulse output: 1,000 Imp/kWh, 25 ms
Temperature range -25°C to +55°C
Max. rel. humidity 75% average, 95% short term
Registered harmonics: 0.05 – 0.25 kHz
LED blinking red consumption >4W, pulsrate= consumption
Display 6 + 2 Digits (999999,11 kWh)
Max diameter Mainclamps: max. 25 mm2
Additional clamps:: max. 2.5 mm2
Baud rate ModBus 9600 baud
Connection diagram 1000 (DIN 43856)
Input “L1, L2, L3” Input Phase L1, L2, L3
Output “L1, L2, L3” Output Phase L1, L2, L3
Clamp “N” Neutral connection N
Clamps 18, 19 S0-pulse output “A+” (Clamp 18 = “+”)
Clamps 20, 21 S0-pulse output „A-“ (Clamp 20 = “+”)
Clamps 22, 23 ModBus-connection 22 -> A, 23 -> B
Clamps 24, 25 External Tariff (230V AC)
Terminal block connector Solar-Log™ PRO380
Clamp Clamp
1 -> 22 (A)
4 -> 23 (B)
V1.1
TechnischeDaten:
Nennspannung:  230/400VAC
Strom:0,255(100)A
Frequenz:50Hz
Messgröße:Wirkverbrauch,Rücklaufsperre
Genauigkeitsklasse:  B
Eigenverbrauch:   <10VA<2W
Breite:4TE(70mm)
ImpulsausgangLED:  10.000Imp/kWh,2,5ms
S0–Impulsausgang:  1.000Imp/kWh,25ms
Arbeitstemperatur:   25°Cbis+55°C
Max.rel.Lufeuchte:  75%imMiel,kurzzeig95%
RegistrierteHarmonische: 0,05–0,25kHz
LED:rotblinkend:Bezug>4W,Impulsrate=Verbrauch
Display:6+2Digits(999999,11kWh)
MaximalerLeiterquerschni:Hauptklemmen: max.35mm²
Zusatzklemmen: max.2,5mm²
BaudrateModBus:   9600baud


Anschlussschema:
Zählertyp:  PRO380,100A
NachSchaltungstyp1000(DIN43856)

Input„L1,L2,L3“  ZuleitungseingangPhaseL1,L2,L3
Output„L1,L2,L3“  ZuleitungsabgangPhaseL1,L2,L3
Klemme„N“NeutralleiteranschlussN
Klemmen18,19  S0Impulsausgang„Bezug“(Kl.18=„+“) 
Klemmen20,21  S0Impulsausgang„Lieferung“(Kl.20=„+“)
Klemme22,23   ModBus–AnschlussKlemme22>A,23>B
Klemme24,25  externeTarifumschaltung(230VAC)
KlemmleistensteckerSolarLog PRO380
KlemmeKlemme
1>     22(A)
4>     23(B)
V1.1
AlleAnzeigewertedesZählers:
DurchDrückenderTastenwechseltderZählervonderautomaschrollierendenAnzeige
indiemanuelleAnzeige.HierkönnenmielsTastendruckalleverfügbarenAnzeigewerte
derReihenachaufgerufenwerden.Wirdkeinegedrückt,kehrtderZählernachkurzerZeit
wiederindenautomaschenModuszurück.
InderautomaschrollierendenAnzeigewerdennacheinanderdiefolgenden
Werteangezeigt:
FüreinevollständigeÜbersichtallerverfügbarenAnzeigewerteimmanuellen
ModusbeachtenSiebiedieausführlichetechnischeBeschreibungalsDown
loadaufwww.kdkdornscheidt.de.
ÄnderungderModbusAdressemitHilfederSensortastenamZähler:

1.MitderlinkenPfeiltastedurchdasMenübläern,bis„addr001“
angezeigtwird
2.ZurÄnderungderAdressebeidePfeiltastenfür5secdrücken–Anzeige
blinkt1xauf,wennÄnderungsmodusakvist.
3.MitderrechtenPfeiltasteAdresswerterhöhen,bisgewünschteAdresse
angezeigtwird
4.ZumVerlassendesÄnderungsmodusnochmalsbeidePfeiltastenfür5sec
drücken
5.VerlassendesÄnderungsmoduswirddurchblinkendesDisplaysbestägt
6.SolltedieseBestägungnichterfolgenistGerätimmernochimÄnde
rungsmodus–Bestägungnochmalsversuchen
7.KontrolledereingestelltenAdressedurchannavigierenwie1)
EnergierichtungsanzeigeproPhase123
r=Lieferung(Reverse)F=Bezug(Forward)

WirkenergieBezuginKWh(OBIS:1.8.0)
Saldierend

WirkenergieLieferunginKWh(OBIS:2.8.0)
Saldierend

Momentan‐Leistung(Gesamt)
V1.1
TechnischeDaten:
Nennspannung:  230/400VAC
Strom:0,255(100)A
Frequenz:50Hz
Messgröße:Wirkverbrauch,Rücklaufsperre
Genauigkeitsklasse:  B
Eigenverbrauch:   <10VA<2W
Breite:4TE(70mm)
ImpulsausgangLED:  10.000Imp/kWh,2,5ms
S0–Impulsausgang:  1.000Imp/kWh,25ms
Arbeitstemperatur:   25°Cbis+55°C
Max.rel.Lufeuchte:  75%imMiel,kurzzeig95%
RegistrierteHarmonische: 0,05–0,25kHz
LED:rotblinkend:Bezug>4W,Impulsrate=Verbrauch
Display:6+2Digits(999999,11kWh)
MaximalerLeiterquerschni:Hauptklemmen: max.35mm²
Zusatzklemmen: max.2,5mm²
BaudrateModBus:   9600baud


Anschlussschema:
Zählertyp:  PRO380,100A
NachSchaltungstyp1000(DIN43856)

Input„L1,L2,L3“  ZuleitungseingangPhaseL1,L2,L3
Output„L1,L2,L3“  ZuleitungsabgangPhaseL1,L2,L3
Klemme„N“NeutralleiteranschlussN
Klemmen18,19  S0Impulsausgang„Bezug“(Kl.18=„+“) 
Klemmen20,21  S0Impulsausgang„Lieferung“(Kl.20=„+“)
Klemme22,23   ModBus–AnschlussKlemme22>A,23>B
Klemme24,25  externeTarifumschaltung(230VAC)
KlemmleistensteckerSolarLog PRO380
KlemmeKlemme
1>     22(A)
4>     23(B)
V1.1
AlleAnzeigewertedesZählers:
DurchDrückenderTastenwechseltderZählervonderautomaschrollierendenAnzeige
indiemanuelleAnzeige.HierkönnenmielsTastendruckalleverfügbarenAnzeigewerte
derReihenachaufgerufenwerden.Wirdkeinegedrückt,kehrtderZählernachkurzerZeit
wiederindenautomaschenModuszurück.
InderautomaschrollierendenAnzeigewerdennacheinanderdiefolgenden
Werteangezeigt:
FüreinevollständigeÜbersichtallerverfügbarenAnzeigewerteimmanuellen
ModusbeachtenSiebiedieausführlichetechnischeBeschreibungalsDown
loadaufwww.kdkdornscheidt.de.
ÄnderungderModbusAdressemitHilfederSensortastenamZähler:

1.MitderlinkenPfeiltastedurchdasMenübläern,bis„addr001“
angezeigtwird
2.ZurÄnderungderAdressebeidePfeiltastenfür5secdrücken–Anzeige
blinkt1xauf,wennÄnderungsmodusakvist.
3.MitderrechtenPfeiltasteAdresswerterhöhen,bisgewünschteAdresse
angezeigtwird
4.ZumVerlassendesÄnderungsmodusnochmalsbeidePfeiltastenfür5sec
drücken
5.VerlassendesÄnderungsmoduswirddurchblinkendesDisplaysbestägt
6.SolltedieseBestägungnichterfolgenistGerätimmernochimÄnde
rungsmodus–Bestägungnochmalsversuchen
7.KontrolledereingestelltenAdressedurchannavigierenwie1)
EnergierichtungsanzeigeproPhase123
r=Lieferung(Reverse)F=Bezug(Forward)

WirkenergieBezuginKWh(OBIS:1.8.0)
Saldierend

WirkenergieLieferunginKWh(OBIS:2.8.0)
Saldierend

Momentan‐Leistung(Gesamt)

Other Solar-Log Measuring Instrument manuals

Solar-Log Pro 380 User manual

Solar-Log

Solar-Log Pro 380 User manual

Solar-Log PRO1 User manual

Solar-Log

Solar-Log PRO1 User manual

Solar-Log 350 User manual

Solar-Log

Solar-Log 350 User manual

Solar-Log 200 User manual

Solar-Log

Solar-Log 200 User manual

Solar-Log 2000 User manual

Solar-Log

Solar-Log 2000 User manual

Solar-Log PRO2 User manual

Solar-Log

Solar-Log PRO2 User manual

Solar-Log PRO380 User manual

Solar-Log

Solar-Log PRO380 User manual

Solar-Log PRO380-CT User manual

Solar-Log

Solar-Log PRO380-CT User manual

Solar-Log 300 Instruction manual

Solar-Log

Solar-Log 300 Instruction manual

Solar-Log 300 User manual

Solar-Log

Solar-Log 300 User manual

Solar-Log PRO1 User manual

Solar-Log

Solar-Log PRO1 User manual

Solar-Log PRO380-Mod-CT User manual

Solar-Log

Solar-Log PRO380-Mod-CT User manual

Solar-Log PRO380-CT User manual

Solar-Log

Solar-Log PRO380-CT User manual

Solar-Log 1000 User manual

Solar-Log

Solar-Log 1000 User manual

Solar-Log PRO380 User manual

Solar-Log

Solar-Log PRO380 User manual

Popular Measuring Instrument manuals by other brands

CET PMC-220 installation guide

CET

CET PMC-220 installation guide

wtw K 500 DIN operating manual

wtw

wtw K 500 DIN operating manual

Avermedia EzRecorder 330 user manual

Avermedia

Avermedia EzRecorder 330 user manual

Fieldpiece SMAN SM380VINT Operator's manual

Fieldpiece

Fieldpiece SMAN SM380VINT Operator's manual

Mega Meg39 user manual

Mega

Mega Meg39 user manual

Thermo Scientific Smart-Vue 2.0 Getting started guide

Thermo Scientific

Thermo Scientific Smart-Vue 2.0 Getting started guide

CPS Leak-Seeker LSCG quick start guide

CPS

CPS Leak-Seeker LSCG quick start guide

PCE Health and Fitness PCE-TG 75 user manual

PCE Health and Fitness

PCE Health and Fitness PCE-TG 75 user manual

Arenal QA03-SDA User & maintenance manual

Arenal

Arenal QA03-SDA User & maintenance manual

ITALON GS.01.00.00.000 IM Installation, Adjustment and Connection Manual

ITALON

ITALON GS.01.00.00.000 IM Installation, Adjustment and Connection Manual

Brookfield Thermosel DV-II+ operating instructions

Brookfield

Brookfield Thermosel DV-II+ operating instructions

SEON vMax Pulse Install and Setup Guide

SEON

SEON vMax Pulse Install and Setup Guide

AGFA CR 10-X user manual

AGFA

AGFA CR 10-X user manual

Thorne & Derrick KATRONIC KATflow 150 operating instructions

Thorne & Derrick

Thorne & Derrick KATRONIC KATflow 150 operating instructions

Xylem Sensus iPERL installation manual

Xylem

Xylem Sensus iPERL installation manual

Major tech MT723 instruction manual

Major tech

Major tech MT723 instruction manual

Teac TC-FR(T)-G6 Instructions for use

Teac

Teac TC-FR(T)-G6 Instructions for use

Cadex C4000 SERIES user manual

Cadex

Cadex C4000 SERIES user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.