manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SolaX Power
  6. •
  7. Inverter
  8. •
  9. SolaX Power X3-Retro Fit Series User manual

SolaX Power X3-Retro Fit Series User manual

I
Packing List
Quick Installation Guide
-Drill holes with φ10 drill. Depth: at least 60mm.
-Mark position of six holes.
-Tighten the expansion tubes. Screw the expansion screws.
-Make the bottom of the inverter lean on the bracket.
-Overview of Mounting
- Screw the set screw on the right-top of
inverter tightly.(PH1 cross screwdriver.
torque:3±0.1Nm)
- If necessary, customer can install an
anti-theft lock on the right-top of the
inverter.
AC Connection
EPS wiring diagram
For Australia/New Zealand
For other countries
EPS connection steps:
Note: ConnectPEwire into
1. Make wire(EPS cable size: refer to table 2)
2. Insert EPS cable into EPS port through screw cap.
Note: The right most port
should not be connected !
EPS Connection(for E Version )
Communication interface bewteen inverter and battery is CAN with a RJ45
connector.
Note:
The battery communication can only work when the battery BMS iscompatible
withtheinverter.
B:Communication Connection Steps:
A:Power Connection Steps:
BMS_CANH
GND BMS_485A BMS_485B
GNDNTC GND BMS_CANL
Definition
23 4 56 7 81
PIN
Press down spring until it clicks audibly into place
The ne wire strands must be seen in the champer
wire strands
Battery Connection(optional)
Before connecting to battey, please install a nonpolarized DC breaker to make
sure inverter can be securely disconnected during maintanance.
Battery breaker
Voltage
Current[A] 32A
Model X3-Fit-8.0-E X3-Fit-8.0-C X3-Fit-10.0-E X3-Fit-10.0-C
Nominal voltage of DC breaker should be larger than maximum
voltage of battery.
X3-Retro Fit 8kW-10kW
Mounting Steps
table2: Cable and Micro-breaker recommended
EPS Cable ≥5mm²
EPS breaker
≥5mm² ≥5mm² ≥5mm²
32A 32A 32A 32A
Model X3-Fit-8.0-E X3-Fit-8.0-C X3-Fit-10.0-E X3-Fit-10.0-C
369 mm
260 mm
E Version For Other Countries
E Version For AU/NZ
This function can be achieved manually or automatically according to
user’s preference.
For manual solution, please install an external switch.
L 1
L 2
L 3
N
P E
60mm
12mm
L 1
L 2
L 3
N
60mm
12mm
high-voltage lithium battery.
+
-
CAN
Nonpolarized
DC breaker
Power connection
Communication connection
BMS Port:
The rst RJ45 port from right
- Aim the upper side of the inverter to the top small hook ofthe bracket.
-Press the inverter slightly toward the hole to make it rmly installed.
L1 L1
L2 L2
L3 L3
NN
SolaX
meter
+
-
Battery
E-BAR
Main switch
RCD
PE
SolaX X3-Retro Fit inverter
Loads
L2
L1
L2L1 L3 N
L3
N
EPS
Loads
L2L1 L3 N
RCD
N-BAR
the cable is not
required for
Australia
Changeover device with
interlocked switching
SolaX
meter
+
-
Battery
DPDT
E-BAR
Main switch
RCD
PE
SolaX X3-Retro Fit inverter
Loads
L2
L1
L2L1 L3 N
L3
N
L1 L1
L2 L2
L3 L3
NN PE
EPS
Loads
L2L1 L3 N
RCD
Australia/New Zealand other countries
Battery connection diagram
BMS PIN Denition
3.Insert AC cable into AC port
through screw cap.
a.L-wire,N-wire connection
b.PE wire connection
4. Connect the wire to the AC terminal in the inverter. 
AC connectionsteps(AC cable size:refer to table1):
1.Remove thetop-down cover.
2. Make AC wires.
Cable 4-5mm²
Micro-breaker
4-5mm²5-6mm²5-6mm²
25A 25A 32A 32A
Model X3-Fit-8.0-E X3-Fit-8.0-C X3-Fit-10.0-E X3-Fit-10.0-C
table1
60mm
12mm
L 1
L 2
L 3
N
P E
Step3:Assemble the cable gland and
screw the cable nut.
Step4: Insert one RJ45 side of the cable into
BMS port inside of inverter and the other side
into RS485 or Can port of the battery.
Step1: Disassemble the GEN/Meter
/BMS cable gland.
Step2: Prepare a communication
cable(without sheath)and insert
the communication cable through
the cable nut.
E E
EE
AB C DE
F G HIJ
X3- Retro Fi t User Man ual
8.0kW - 10.0kW
L
X3-Retro-Fi t 8kW-10kW
K
P
PE port at right side!
PE
(The sleeve.torque: 12±0.2Nm)
(φ4hexagon wrench.torque:3±0.1Nm)
(The sleeve .torque:4±0.1Nm)
(One-word screwdriver.torque:2±0.1Nm)
(tighten torque:3.0Nm) (tighten torque:3.0Nm) (tighten torque:3.0Nm)
(tighten torque:2.0Nm) (tighten torque:3.0Nm)
O
N
M
Earth Connection&Start Inverter
Earth Connection Steps(mandatory):
Startinverter
Inverter will start up automatically when the battery is discharging.
Check the status of indicators and LCD screen. The left indicator should
be blue and the indicator screen should display the main interface.
Start Guide Monitoring Operation
Cable size: 12AWG.
ring terminal
Meter Connection
English
Deutsch
Language
Country
VDE0126
Safety
Mode Select
> self use <
Work Mode
1.Set language 2.Set date time 3.Set the safety standard
This function allows the inverter able to control energy exported to the grid.
There are user value and factory value. The factory value is default which can not be charged
by user. The user value setting by installer must be less than the factory value.
4.Set export control
5.Set work mode
There are 4 work modes for choice.
Self use/
Back up mode/
Feed in Priority/
Force Time Use
6.Set EPS system(For E Version only)
X3-Retro Fit inverter with E Version can work on the EPS mode.
EPS parameters can be set as below.
- “Mute”means you can set the warning of system which has entered EPS mode.
- ”No”means there will be a buzzing and it is the default value.
- ”Yes”means you choose to shut down the warning function.
Besides ,if the buzzing is sharp, it means EPS output is over loads.“
Frequency “here can be set 50Hz or 60Hz please based on correlative loads.
7.Set relay control (The function is being developed)
Relay Control is an optional function which can control designated load
intelligently by consuming the surplus energy when feed in power reaches
certain value.
This function can only be achieved with solax product “Smart Plug”.
For specific operation, please refer to “ Smart Plug user manual”.
1) Insert L/N wires and the 485cable
into the meter.
Meter connection step
To grid-L
To inverter-L
To grid-N
To inverter-N
485A
485B
7 111
36 9
1516
4
3
14711
69
Meter connection diagram
Electrical
grid
Home Electric meter,
Three phase
meter
Load
Meter connection
L
N
Communication interface bewteen inverter and meter is RS485 with
a RJ45 connector.
User value:
Export Control
4000W
Battery will stop discharing to keep higher capacity when the
grid is on. Only when the gird is off and PV energy is not
enough, battery will start to discharge to keep the emergency
load working normally.
This work mode applies to the area where suffering from
blackout regularly.
The priority of inverter output power is:
supplying the load feeding to the grid charging the
battery.
This work mode applies to the area with high feed-in tariff.
Self Use
(default)
Force Time Use
Back Up Mode
Feed in Priority
The external generator generated power will be used to supply
the local loads firstly, then to charge the battery. The redundant
power will export to the public grid.
When there is no external generator supplied, battery will
discharge for local loads firstly, and grid will supply power when
the battery capacity is not enough.
In this work mode the charging and discharging time can be set
flexibly, and it also allows to select whether charge from the grid
or not.
Parameter Comment
c. Insert connection into corresponding Meter terminal inside of the
inverter.
a. Unscrew the cable nut of Meter connector and insert two
communication wires through it.
485A 485B
b. Trip the insulation from the communication cable, and then
insert it into connector.
wires 485A
485B
Firmware Upgrading
Please ensure the inverter is steadily powered on. Inverter must keep the battery on through whole procedure of upgrading. Please prepare a PC and
an U-disk.
Preparation
Warning!
Make sure the input power is more than 180V (operate the upgrade on a sunny day), otherwise it may result in serious failing during upgrading.
1) Please contact our service support to get the update les, and extract itintoyourU-disk as following: 
2) Press the “Enter” key for 5 seconds to enter Off Mode. Then unscrew the waterproof lid and insert U-disk into the “upgrade” port at the
bottom of the inverter.
“update\ARM\618.00098.00_Hybrid_X3G3_Manager_VX.XX_XX-XX.usb”;
“update\DSP\618.00096.00_Hybrid_G3X3_Master_VX.XX_XX-XX.hex”;
3) The LCD will be shown as the picture. Then press up and down to select the one that you want to upgrade and press “OK” to confirm to
upgrade.
>ARM
4) After the upgrade is finished, the LCD will display “succeed”(only for DSP upgrades), please remember to pull off the U-disk, screw the
waterproof lid and press the “Esc” to return to the Main interface. Then press the “Enter” key to exit Off Mode.
U-disk
Update
DSP
Update(ARM)
Updating---------25%
614.00260.01
Solax provides two ways for users to choose: WiFi(optinal) and Ethernet(LAN)
Inverter provides a WiFi port which can collect data from inverter and transmit it to monitoring-website via a Pocket WiFi.
(Purchase the product from supplier if needed)
Diagram
Could
Router
WiFi Connection Steps:
Step3. Create an user account online.( Please check the Pocket WiFi user
manual for more details.)(PH1 cross screwdriver .torque:1.5±0.1Nm)
Step1. Plug Pocket WiFi into “WiFi” port at the bottom of the inverter.
Step2. Build the connection between the inverter and router.
WiFi(optinal)
LAN
LAN Connection Steps:
LAN Port: The RJ45 port from right side Third
LAN/DRM Port
Communication interface bewteen inverter and router is RS485
with a RJ45 connector.
LAN PIN Definition
Application Occasion
This function is appliable for the below situation:
When the WiFi signal is too weak to transmit data, user can
use LAN port for the monitoring with a data cable.
Note: The WiFi module still needs to be connected
when using LAN connection.
TX+
TX- RX+ X X RX- X X
123 4 56 7 8
1
8
Could
Router
data cable
Please refer to BMS connection steps (for user manual page30) for LAN connection. Please kindly noted the PIN definition and port
position will be slightly different.
Ethernet(LAN)
LAN communication is the standard communication interface. It can transmit the data between the router and inverter via the l
ocal network.
2) Insertthe other side of the cable into the meter port on the
inverter.
SolaX
meter
+
-
Battery
DPDT
E-BAR
Main switch
RCD
PE
SolaX X3-Retro Fit inverter
Loads
L2
L1
L2L1 L3 N
L3
N
L1 L1
L2 L2
L3 L3
NN PE
EPS
Loads
L2L1 L3 N
RCD
1
36
2
5
6
4
6
7
Turn on the AC switch, EPS switch and battery switch.
Press the “Enter” key for five seconds to exit Off Mode. (The mode is factory
defaulted as Off Mode)
Make sure the external EPS contactor is connected well. (if needed)
Make sure the battery is connected well.
Make sure the meter is connected well.
Make sure all the AC wirings are completed.
Ensure the inverter fixed well on the wall.
E
>Relay1 Setting
>Relay2 Setting
Relay Control
(φ4hexagon wrench.torque:2.0±0.2Nm)
>2013 - 06 - 06
10 : 19
Date time
> Mute: No
Frequency: 50Hz
EPS auto restart
EPS system

Other manuals for X3-Retro Fit Series

4

Other SolaX Power Inverter manuals

SolaX Power X3 Hybrid Series User manual

SolaX Power

SolaX Power X3 Hybrid Series User manual

SolaX Power A1-Hybrid-6.0-US User manual

SolaX Power

SolaX Power A1-Hybrid-6.0-US User manual

SolaX Power X3-MGA-20K-G2-LV User manual

SolaX Power

SolaX Power X3-MGA-20K-G2-LV User manual

SolaX Power X1 Series User manual

SolaX Power

SolaX Power X1 Series User manual

SolaX Power X3-Retro Fit Series User manual

SolaX Power

SolaX Power X3-Retro Fit Series User manual

SolaX Power DataHub 1000 User manual

SolaX Power

SolaX Power DataHub 1000 User manual

SolaX Power BMS Parallel Box-II User manual

SolaX Power

SolaX Power BMS Parallel Box-II User manual

SolaX Power X3-MEGA G2 Series User manual

SolaX Power

SolaX Power X3-MEGA G2 Series User manual

SolaX Power X1 Series User manual

SolaX Power

SolaX Power X1 Series User manual

SolaX Power X1-Hybrid-3.0-D User manual

SolaX Power

SolaX Power X1-Hybrid-3.0-D User manual

SolaX Power X3-Retro Fit Series User manual

SolaX Power

SolaX Power X3-Retro Fit Series User manual

SolaX Power X3-ULTRA User manual

SolaX Power

SolaX Power X3-ULTRA User manual

SolaX Power X3-Fit-G4 User manual

SolaX Power

SolaX Power X3-Fit-G4 User manual

SolaX Power X1 Series User manual

SolaX Power

SolaX Power X1 Series User manual

SolaX Power X1 Series User manual

SolaX Power

SolaX Power X1 Series User manual

SolaX Power X1-Retro Fit User manual

SolaX Power

SolaX Power X1-Retro Fit User manual

SolaX Power X3-ULTRA User manual

SolaX Power

SolaX Power X3-ULTRA User manual

SolaX Power X3-FORTH Series User manual

SolaX Power

SolaX Power X3-FORTH Series User manual

SolaX Power X1 Series User manual

SolaX Power

SolaX Power X1 Series User manual

SolaX Power X1-Hybrid-G4 User manual

SolaX Power

SolaX Power X1-Hybrid-G4 User manual

SolaX Power BMS Parallel Box-II User manual

SolaX Power

SolaX Power BMS Parallel Box-II User manual

SolaX Power X3-Retro Fit Series User manual

SolaX Power

SolaX Power X3-Retro Fit Series User manual

SolaX Power X1-Hybrid-3.0-LV User manual

SolaX Power

SolaX Power X1-Hybrid-3.0-LV User manual

SolaX Power X1 Series User manual

SolaX Power

SolaX Power X1 Series User manual

Popular Inverter manuals by other brands

bluetron HSI Series Installation and operating instructions

bluetron

bluetron HSI Series Installation and operating instructions

Wagan 2003-5 user manual

Wagan

Wagan 2003-5 user manual

Sungrow SH3.0RS user manual

Sungrow

Sungrow SH3.0RS user manual

Power One AURORA PVI-6000-OUT-US-W Installation and operation manual

Power One

Power One AURORA PVI-6000-OUT-US-W Installation and operation manual

Champion 200978 Operator's manual

Champion

Champion 200978 Operator's manual

Goodwe EH Plus Series Quick installation guide

Goodwe

Goodwe EH Plus Series Quick installation guide

Deye SUN-30K-G04 user manual

Deye

Deye SUN-30K-G04 user manual

Growatt 8000MTLP-S Installation & operation manual

Growatt

Growatt 8000MTLP-S Installation & operation manual

Hitachi HFC-VWA2 SERIES instruction manual

Hitachi

Hitachi HFC-VWA2 SERIES instruction manual

Olimpia splendid DC 18 HP Instructions for installation, use and maintenance

Olimpia splendid

Olimpia splendid DC 18 HP Instructions for installation, use and maintenance

Buderus SKR6.1R Installation and maintenance instructions

Buderus

Buderus SKR6.1R Installation and maintenance instructions

Olimpia splendid Unico Instructions for installation, use and maintenance

Olimpia splendid

Olimpia splendid Unico Instructions for installation, use and maintenance

Sungrow SG125HV Quick installation guide

Sungrow

Sungrow SG125HV Quick installation guide

Dometic Go Power! Solar All Electric Kit GP-AE-4 user manual

Dometic

Dometic Go Power! Solar All Electric Kit GP-AE-4 user manual

EMS Piezon C51 installation instructions

EMS

EMS Piezon C51 installation instructions

Nastec NERA STOP MODULE Installation and operation manual

Nastec

Nastec NERA STOP MODULE Installation and operation manual

ORO DC12V-AC220V product manual

ORO

ORO DC12V-AC220V product manual

Solplanet ASW H-S Series user manual

Solplanet

Solplanet ASW H-S Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.