Somogyi Elektronic home COG 01 User manual

COG01
instructionmanual
használatiutasítás
návodnapouž itie
manualdeutilizare
uputstvozaupotrebu
navodilozauporabo
uputazauporabu
návodkpouž ití
használatiutasítás
návodnapouž itie
manualdeutilizare
uputstvozaupotrebu
navodilozauporabo
návodkpouž ití
uputazauporabu


COG01
carbon-monoxideandgassensor
•detectsthepresenceofcarbon-monoxide(CO),agaswithnocolororsmell,andofcommonhouseholdgasessuchasPBandnaturalgas
•requiresnoassemblyormaintenance;youcanstartusingtheproductinstantly
•highlysensitive:alertswhenCOconcentrationexceeds200ppm
•soundalarm(min.85dB)
•LEDindicators
•1,4 mpowercord
•powersuply:230V~/50Hz
Productparts:
1.Speaker
2.LEDpoweronindicator
3.LEDCOindicator
4.LEDgasindicator
5.Gassensorhole
6. Wall mount
7. CO test button
8. Power cord
9. Mounting holes
COG01 hastwoseparate built-insensorstodetect thepresenceof carbon-monoxide,andofother commonhouseholdgases suchasnaturalgas, methane(CH4),as wellaspropane
(C3H8)andbutane(C4H10),whicharecommonlydistributedincylinders.Forhigherreliability,boththeCOsensorandthecircuitryincludeaself-testingmechanism.Thesensor’sLED
lightssignalalldetectedsituations.Thealarmalwayssoundsbeforethegas’sconcentrationreachesalethallevel.
Locatingthedevice
Thesensorscandetectthepresenceofcarbon-monoxide,naturalgas(methane),propaneandbutane.Whenlocatingthesensor,thekeythingtoconsideriswhatsortofdangeryouare
tryingtoprotectyourselffrom.
Thedensityofcarbon monoxideissimilarto thatofwarmair,therefore theidealheightwherethesensorshould belocatedisat least1.5metersabovethefloorlevel, anditshouldbe at
least 1.8meters awayfrom the supervised burningdevice. Do not placethe sensor closerthan 30cm toany corner.The sensor willonly measure a realisticvalue for the roomif you
observetheaboveparameterswhenlocatingit.
Thesensor shouldbe placedcloseto appliancesthat produceexhaust.Wheneverany materialis burntina suboptimalway,thereis apotential emergencybecausecarbon-monoxide
maybeproduced:
-gasstoves,gascookers,gasheaters,gaswaterheaters,gasfurnaces,fireplaces,oilheaters,woodorcoalfueledheaters,gardenstoveswithgrill,cigarettesmoke,carexhaust
pipesetc.
Ifachimneyis blockedorunderunfavorable windconditions,theexhaust ofburnersmaybechanneled backindoors.Carbon-monoxidecan accumulateneartheburners connectedto
the chimney,and alsonear thevent orservice doorat thebottom ofthe chimney.Asimilarsituationcan buildup nearthe fanslocated abovegasstoves.As modern,perfectly isolated
doorsandwindowsbecomeincreasinglywide-spread,homeslosetheirpreviousnaturalventilation.
Attention!Thesensorcanonlydetectdangerouscarbon-monoxidelevelsintheparticularroomwhereitislocated.Carbon-monoxide,however,maystillbepresentinotherplaces.
Thedensity ofhousehold gasesvaries ona largescale.Youneedtodecide whichgas youwish todetect, andplace thesensorabovethe flooror belowthe ceilingaccordingly. Inboth
bases,the sensor’snearest sideshould be30 centimetersaway fromthechosen surface(floor orceiling). Naturalgas islighter thanair,which meansit accumulatesinhigher places;
therefore, to detect naturalgas, place the sensor below theceiling. Propane-butane is heavierthen air, thereforeto detect propane-butane, place the sensorabove the floor. In both
cases,itisbesttomountthesensoronawall.
Whenlocatingthedevice,makesureyouobservethefollowing:
Forreliableoperation,avoidthefollowingenvironmentalconditions:
0 0
-temperaturesbelow-10 Corabove50 C;
-wet,humid,dusty,dirtyorpollutedair;
-areasbehindacurtainorpieceoffurniture;
-closetocoolingorheatingdevices,behindfans;
-inthewayofairflow,e.g.,nexttoanopendoororwindow;
-anylocationwheresmokeorsteammaynaturallybepresent(e.g.,nearthestove,burnerorelectrickettleinthekitchen);closetoasmokingarea;
-inlocationswithhighhumidity(e.g.,immediatelyaboveasink,ornexttoabathtub,showercabin,washingmachineetc.);
-nearthecar’sexhaustinagarage.
Installation
1.Choosewhereyouwishtolocatethedeviceasdescribedabove.
2. Fasten the wall mount to the desired location.
3. Slide the sensor onto the wall mount.
4. Connect the sensor to the power network. The product will emit a beep and the power on LED (2) will start to flash (lit up for 3 seconds, then turned off for 1
second). This indicates that the product is working correctly.After 3 to 5 minutes, the product is ready for use.
Testingandself-diagnostics
Itisrecommendedtotestthecarbon-monoxidesensorwheninstallingtheproduct;thenrepeatthetestonceeveryweek.PressandholdtheCOTESTbutton(6)for
1-2seconds.Thecarbon-monoxideindicatorLED(3)willflashup3timesinread,andtheproductwillemit3shortbeeps.
Itisnot possibleto testthe gassensor bypressing abutton; forthispurposeuseadevicewith asmall amountof gas(e.g., anunlit lighter).Hold thelighter5
centimeters awayfrom thegas sensor’shole(5), andlet gasenter throughthe holefor afewseconds.The productwill emita beepand thegas indicator
LED(4)willstarttoflash.Thissignalwilllastaslongastheproductdetectsthepresenceofgas.Whenthatisnolongerthecase,thesensorgoesbackto
normalmode.
Do nottest the productin anyother way(e.g., by blowingsmoke directlyinto it)because that candamage the sensor.Under proper use,the
sensor’sexpectedlifetimeis5years.

Operation,alarm
Innormalmode,thepoweronLED(2)islitup.Iftheproductdetectscarbon-monoxide,theCOindicatorLED(3)startstoflashinred,accompaniedbya
beeping sound. If the product detects gas, the gas indicator LED (4) starts to flash in red. As part of its normal operation, the product tests carbon-
monoxideperiodically.Whilethistestisinprogress,theCOindicatorLED(3)islitingreenforafewseconds.
OperationoftheLEDindicators:
Importantnotes
Itispossiblethatgasproducedinadistantpartofthebuildingdoesnotreachthesensorintimetoalarmthepeopleinsideontime(e.g.,becausesomedoorsareclosed).
The sensordoes not immediatelyindicate thatthere is dangeroussituation unlessit is locatedin theroom where thegas isproduced. Even inthat case,the alarm only goesoff ifthe
concentrationofthegasexceedsthedangerousthreshold.The sensordoes notdetect heat,smoke, flamesor light.There maybe scenarioswhere thegasdoesnotreachthesensor
fastenoughand,asaresult,theremaynotbeenoughtimetoescape.
Itisnotguaranteedthatthesensorcanalwaysalarm everyoneintime.Theloud soundalarmmaybe suppressedbyothernoise suchasmusic,and itmaybemore difficulttorecognize
forpeoplewithimpairedhearing.Thesensorcannotwarnpersonsundertheinfluenceofmedicationoralcohol.Insuchcases,itisrecommendedtoinstallspecialgassensorsifneeded.
Inorder tominimizerisk,people mustbecomeawareofthe alarmimmediately,andmust actquicklyand inthecorrectway.Youneedtoidentifythe sourceofthegas, ventilatetheroom
and,incaseoflethalhazard,youmustescapefromthebuilding.Open alldoorsandwindows. Informallpeoplethat maybeaffected.Ifit ispossible,turnoffthedevicethatissuspected
tobemalfunctioning.
Whenyouarestartingtousethesensor,explaineveryoneinthehouseholdwhattheyneedtodoincaseofanalarm;identifypossibleescaperoutes.
Staycalmandleavethebuildingasquicklyaspossible;ifneeded,calltheemergencylineforanambulanceandfirefighters.
Thissensorisnotdesignedtoprovideprofessionalreliability;itisnotguaranteedtosavelivesincaseofagasleakage.Theproductcannotreplaceotherreasonableprecautionsandthe
usualtypesofinsurance.Makingsuretheseareinplaceistheresponsibilityofthepeopleusingthebuilding.
Ifthereisanalarmwhileyouareaway,contactatechniciantohaveyourburningdevicesinspected.
Itis recommendedto removedust,dirt anddead insectsfromthe outsideofthesensor atleast onceeverymonth. Neverpaint overthesensor,and makesurenopaint ordust fromthe
wallgets insidethe product.For regularcleaning, usea softbrush, aclothand avacuum cleaner.Make surethe ventsarenot blocked.Theproductrequires nocleaning inside;never
disassembletheproduct.
Thesensorisdesignedforindoorhouseholduseonly.Donotexposetheproducttodirectsunlightorheat.
Technicalparameters
detectedgas:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . carbon-monoxide(CO),naturalgas(methane,CH4),propane(C3H8),butane(C4H10)
sensortype:...........................................................................................electro-chemical
expectedsensorlifespan: .......................................................................................5years
0 0
environmenttemperature:...................................................................................-10C–50C
humidity:...................................................................................................10–95%
alarmsoundstrength: ................................................................................85dB/3mminimum
alarmthreshold(concentration/duration):................................................................200ppm(30seconds)
powersupply:...........................................................................................230V~/50Hz
dimensions:...........................................................................................115x72x41mm
COG01
carbon-monoxideandgassensor
Carbon-monoxide LED indicator Gas LED indicator
Red Green Yellow Red Green Yellow
Carbon-monoxide detected Flashing
Gas detected Flashing
CO sensor malfunction Flashing
Gas sensor malfunction Flashing

szén-monoxidésgázérzékelő
COG01
•érzékeliésjelziaszíntelenésszagtalanszén-monoxid(CO),valamintaháztartásbanhasználatosgázok(PB,földgáz)jelenlétét
•szereléstéskarbantartástnemigényel,azonnalüzembehelyezhető
•nagyérzékenységű,már200ppmCOkoncentrációfelettriaszt
•hangosriasztás(min.85dB)
•LEDállapotjelzők
•1,4mhálózaticsatlakozókábel
•tápellátás:230V~/50Hz
Aberendezésrészei:
1.Hangszóró
2.MűködéstvisszajelzőLED
3.COérzékelésvisszajelzőLED
4.GázérzékelésvisszajelzőLED
5.Gázérzékelőnyílás
6. Rögzíto elem
7. CO teszt gomb
8. Hálózati csatlakozókábel
9. Rögzíto fülek
A COG 01 a beépített két külön szenzor segítségével érzékeli a szén-monoxid és a háztartásban használatos gázok- a természetes gázok (földgáz, metán (CH4)), valamint a
palackokba töltött propán (C3H8) és bután (C4H10) gázok- jelenlétét.A megbízhatóság érdekében a CO szenzor és az elektronika saját öntesztelő funkcióval rendelkezik.ALED
visszajelzőkmindenállapotrólmegfelelőtájékoztatástnyújtanak.Ariasztásmégazelőttbekövetkezik,hogyazadottgázkoncentrációéletveszélyeslenne.
Akészülékelhelyezése
AzérzékelőCOésföldgáz(metán),valamintpropán-butángázokérzékeléséreképes.Azelhelyezésnélaztkellfigyelembevenni,hogyelsősorbanmilyenfenyegetettségetszeretnénk
védeni.
A szén-monoxid hasonló sűrűségű, mint a meleg levegő, ezért a készülék ideális elhelyezési magassága padlószint felett legalább 1,5 méter, és a megfigyelt készüléktől legyen
legalább1,8métertávolságra.Nehelyezzeasarkokhoz30centiméternélközelebb!Ígyfogazadotthelyiségreténylegesenjellemzőértéketmérni.
Ariasztótelsősorbanazokhoz aberendezésekhezközel kellelhelyezni,amelyek működésesoránégéstermékjönlétre. Mindentökéletlenégési folyamatnálveszélyhelyzetléphetfel,
mertszén-monoxidkeletkezik:
- gáztűzhely, gáz főzőlap, gázkonvektor, gázbojler, gázkazán, gáz fűtőkészülék, kandalló, olajkályha, fa- és széntüzelésű kályha, grill tűzhely, cigarettafüst, autó-motor
kipufogócső…
Akéménydugulása,vagyesetenkéntaszerencsétlenszéljárás következtébenvisszaáramolhatazégéstermékalakásba.Akéményrekötöttkazánésegyébkészülékekmellett,illetve
a kémény alsó szellőző, tisztító nyílásainál is megjelenhet a gyilkos gáz. Hasonló eset fordulhat elő a gáz főzőlap feletti konyhai légelszívók esetében is. Amai, kiválóan szigetelő
nyílászáróknemtesziklehetővéalakásokkorábbitermészetesszellőzését.
Figyelem!Akészülékcsakarraahelyiségrevonatkozóanjelziaszén-monoxidveszélyeskoncentrációjújelenlétét,aholelhelyezték!Ettőlfüggetlenülagázmásuttisjelenlehet!
A háztartási gázok fajsúlya jelentős mértékben eltérő. Meg kell határozni, hogy melyik anyag figyelése a cél, és annak megfelelően kell a padlószint fölé, vagy a mennyezet alá
elhelyezni – mindkét esetben attól 30 centiméterre legyen a készülék legközelebbi oldala. Aföldgáz könnyebb a levegőnél, ezért felfelé törekszik, ebben az esetben az érzékelőt a
mennyezetalákelltenni.Apropán-butángáznehezebbalevegőnél,ezértakészüléketapadlószintfölékellhelyezni.Lehetőségszerintoldalfalracélszerűszerelni.
Azelhelyezésnélügyeljenakövetkezőkre:
Amegbízhatóműködésérdekébenelkellkerülniazalábbikörnyezetikörülményeket:
0 0
-–10 C-nálhidegebb,vagy50 C-nálmelegebbhőmérséklet;
-nyirkos,párás,poros,piszkos,szennyezettlevegő;
-függönyésbútormögöttihely;
-hűtő-vagyfűtőberendezésekközvetlenközele,ventilátorokmellett;
-nemhelyezhetőazáramlólevegőútjába,pl.nyitottajtóésablakmellé;
-nemtehetőolyanhelyre,aholtermészetesmódonjelenlehetfüstvagygőz(pl.konyhábanatűzhelyésfőzőlapközelébe,vízmelegítőmellé...);dohányzóhelyközelébe;
-magaspáratartalmúhelyekre(pl.közvetlenülmosogatófölé,fürdőkád,zuhanykabin,mosógép…mellé)
-garázsbanakipufogógázkeletkezésénekközelébe.
Üzembehelyezés
1.Határozzamegafentiekszerintakészülékhelyét!
2. Csavarozza fel a hátlapot a kívánt helyre!
3. Csúsztassa bele a készüléket a rögzítő elembe!
4. Csatlakoztassa az érzékelőt a hálózatra! Ekkor hangjelzés kíséretében a működést visszajelző LED (2) villogni kezd – 3mp világít, 1mp kikapcsol, ez mutatja a helyes
működés kezdetét. 3-5 perc után a készülék üzemképes.
Tesztelés,öndiagnosztika
ACO érzékelő tesztelését az üzembe helyezésnél, majd folyamatos működésnél hetente javasolt elvégezni. Nyomja 1-2 másodpercig a CO teszt gombot (6).A CO
érzékelésvisszajelzőLED(3)3-szorpirosanfelvillanés3rövidhangjelzéstadakészülék.
Agázérzékelő funkciótgombsegítségévelnem tudjuktesztelni,eztegy gyengébbgázkibocsátásúeszközzel(pl. egynemmeggyújtottöngyújtóval) tudjuk.Tartsa
az öngyújtót a gáz érzékelő nyílástól (5) 5 cm-re, és engedje néhány másodpercig a nyílásba a gázt. Ekkor készülék hangjelzést ad és a gáz érzékelés
visszajelzőLED(4)villognikezd.Mindaddigezállfenn,amígagáztérzékeliakészülék.Amikorezmegszűnik,visszaállalaphelyzetbe.
Ne teszteljea készüléketmás módon(pl. közvetlenül füstötfújva bele), mert szennyeződhetaz érzékelője. Normál használatmellett 5 év aszenzor
várhatóélettartama.

szén-monoxidésgázérzékelő
COG01
Működés,riasztás
Alaphelyzetben aműködést visszajelzőLED (2)világít. COérzékelés eseténa hangjelzésmellett, aCO érzékelésvisszajelző LED(3) kezd pirosan
villogni. Gáz érzékelés esetén a gáz érzékelés visszajelző LED (4) kezd pirosan villogni. Az üzemszerű működés közben az készülék CO érzékelője
bizonyosidőközönkéntfelülvizsgálatottart,ekkoraCOérzékelésvisszajelzőLED(3)zöldenvilágítnéhánymásodpercig.
LEDvisszajelzőkműködése:
Fontostudnivalók
Előfordulhat,hogyazépülettávolabbirészénmegjelenőgáznemjutelidejébenazérzékelőhöz,hogyazfigyelmeztesseaháziakat(pl.becsukottajtókmiatt).
Az érzékelő nem figyelmeztet azonnal a veszélyre, hacsak nem éppen abban a helyiségben jelentkezik, ahol el van helyezve. Ez esetben is csak a gáz töménységének riasztási
küszöbszintetmeghaladóértékeeseténjelez.Nemérzékelhőt,füstöt,lángotvagyfényt.Előfordulhatnakolyanesetek,amikoragáznemérieleléggyorsanazérzékelőt,emiattesetleg
nembiztosítvaelegendőidőtameneküléshez.
Nem garantált, hogy minden esetben, minden érintettet tud figyelmeztetni. Az erős hangjelzést elnyomhatja más zaj, pl. zenehallgatás, vagy hallássérült emberek nehezebben
azonosítjákbe.Gyógyszerekésalkoholhatásaalattállóembertnemtudfigyelmeztetni.Ilyenesetekben,szükségeseténszereltessenfelspeciálisgázérzékelőket.
A kialakult veszély minimalizálása érdekében azonnal tudomást kell szerezni a riasztásról és gyorsan, valamint megfelelően kell reagálni rá. Be kell azonosítani a veszélyforrást,
szellőztetni kell,és életveszély eseténki kellmenekülni az épületből.Nyisson ki mindenajtót ésablakot! Értesítsen mindenérintettet! Havan rá lehetősége,kapcsolja ki avélhetően
hibásberendezést!
Használatbavételkormagyarázzaelacsaládtagoknak,hogymiateendőjükegyesetlegesriasztáskor,határozzákmegelőrealehetségesmenekülésiútvonalakat.
Maradjanaknyugodtak,ésminélgyorsabbanhagyjákelazépületet,majdszükségeseténhívjákamentőketésatűzoltókat!
Ez akészülék nem professzionálisanüzembiztos kivitelű, nem garantáljagázszivárgás esetén az életmentést.Nem helyettesíti az elvárhatóegyéb óvintézkedéseketés aszokásos
biztosításokmegkötését.Ezalakókfeladata.
Atávollétébenbekövetkezettriasztáseseténellenőriztesseberendezéseitszakemberrel!
Akészülékházról ajánlott legalább havonta eltávolítani a port, piszkot, rovar- és bogármaradványokat. Nem szabad lefesteni és vigyázzon, hogy ne kerülhessen bele faltörmelék,
vakolat.Rendszeres tisztításáhozhasználjon puhaecsetet, törlőkendőtés porszívót.Győződjönmegaszellőzőrácsok átjárhatóságáról!Akészüléket belülnem kelltisztítani,tilosazt
szétszerelni!
Kizárólagbeltéri,háztartásihasználatraalkalmas.Neérjeközvetlenülnapfényvagyhősugárzásakészüléket!
Műszakiadatok
érzékeltgázfajtája: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . szén-monoxid(CO),földgáz(metánCH4),propán(C3H8),bután(C4H10)
érzékelőtípusa:..........................................................................................elektro-kémiai
érzékelővárhatóélettartama:.......................................................................................5év
0 0
környezetihőmérséklet:....................................................................................-10C–50C
környezetipáratartalom:.......................................................................................10–95%
hangjelzéserőssége:.....................................................................................min.85dB/3m
riasztásiszint(koncentráció/időtartam):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200ppm(30másodperc)
tápellátás:..............................................................................................230V~/50Hz
méretek:.............................................................................................115x72x41mm
CO érzékelés visszajelző LED Gáz érzékelés visszajelző LED
Piros Zöld Sárga Piros Zöld Sárga
CO érzékelés Villog
Gáz érzékelés Villog
CO érzékelő hiba Villog
Gáz érzékelő hiba Villog

COG01
detektorprítomnostioxiduuhoľ natéhoaplynu
•zisťujeasignalizujeprítomnosťbezfarebnéhoanepáchnucehooxiduuhoľnatého(CO), aplynu,používanévdomácnosti (PB,zemnýplyn)
•nevyžadujemontážaúdržbu,dásaokamžiteuviesťdoprevádzky
•mávysokúcitlivosťaspustívýstražnúsignalizáciuužnadkoncentráciou200ppmCO
•hlasnávýstražnásignalizácia(min.85dB)
•LEDkontrolkypreindikáciustavuchránenéhopriestoru
•1,4msieťovýpripojovacíkábel
•napájenie:230V~/50Hz
Súčiastkyzariadenia:
1.Reproduktor
2.LEDkontrolkafungovania
3.LEDkontrolkapreindikáciuprítomnostiCO
4.LEDkontrolkapreindikáciuprítomnostiplynu
5.Otvor preindikáciuplynu
6.Fixačnýprostriedok
7.TlačidlonatestovanieCO
8.Sieťovýpripojovacíkábel
9.Fixačnéuši
COG 01 so2 zabudovanými senzormi zisťuje a signalizuje prítomnosťbezfarebného a nepáchnuceho oxiduuhoľnatého (CO), a plynu, používanýchv domácnostiach (PB, zemný
plyn,metánCH4)abombový propán(C3H8)abután (C4H10).KvôlispoľahlivostiCOdetektor aelektronikadisponujesosamodiagnostikou.LEDkontrolkynásupozorniaainformujú.
Alarmzačnefungovaťeštepredtým,kýmkoncentráciaplynubybolaživotunebezpečný..
Umiestnenieprístroja
DetektorsignalizujeCO, zemnýplyn(metán)apropán-butánplyny.Priumiestneníprístrojadbajtenato,akétypyplynovchcetesignalizovať.
CO je podobnej hustotyako vzduch, preto je ideálne prístrojumiestniť min. 1,5 m nad podlahoua od kontrolovaného prístroja má byťvo vzdialenosti 1,8 m. Neumiestňujte prístrojk
rohombližšieako30cm!Taktobudemeraťskutočnéhodnotypredanúmiestnosť.
Alarmjepotrebnévprvomradeumiestniťvblízkostitýchprístrojov,priktorýchpoužívaníprichádzakvytvoreniuspalín.Prikaždomneúplnomhorenímôženastaťnebezpečenstvo,lebo
savytváraoxiduhoľnatý:
-komín,plynovýsporák,plynovárúra,plynový konvektor, plynovýbojler,plynový ohrievač,krb,olejovýradiátor, pecv ktoromsa používadrevo nadrevoauhlie,gril,cigaretový
dym,motorauta…
Priupchaníkomína alebov prípadochnevhodnéhofúkania vetra,plyn samôžedostaťspäťdo bytu.Životunebezpečnýplynsamôžeobjaviť ajprikotlynapojenéhonakomín,alebo pri
dolnej vetracej, čistiacej časti komína. Podobný prípad môže nastať aj v prípade digestorov nad kuchynskými plynovými sporákmi. Dnešné okná a dvere s výbornou izoláciou
neumožňujúpôvodnéprírodnévetraniabytu.
Pozor!PrístrojsignalizujenebezpečnúkoncentráciuCOibavtommiestnosti,vktorejjeumiestnený.Nezávisleodtohoplynmôžebyťajinde!
Špecifikačnéhmotnosti plynovvdomácnostisú rozdielne.Musíteurčiť,výskyt akejlátkymieniteprístrojom sledovaťa vzávislosti odtohohoumiestnite nadúroveňpodlahyalebo pod
úroveňstropu,v obochprípadoch musíbyťnajbližšiastranaprístroja odpodlahy čistropuvzdialená 30cm. Zemnýplynjeľahšíako vzduch,a pretostúpasmeromhore.Ak chcetezistiť
prítomnosť zemného plynu v miestnosti, detektor musíte umiestniť pod strop. Propán-bután je ťažší ako vzduch a ak chcete zistiť jeho prítomnosť, detekčný prístroj je potrebné
umiestniťnadúroveňpodlahy.Prístrojsamáinštalovaťpodľamožnostinabočnústenumiestnosti.
Priumiestnenídbajtenanasledovnéveci:
Kvôlibezpečnémuprevádzkovaniusamávyhnúťnasledovnýmpodmienkamprostredia:
0 0
-teplotanižšiaako-10 C alebovyššiaako50 C
-vlhký,znečistenývzduch,sprachom,parou
-priestorzazáclonoualebozanábytkom
-priamablízkosťchladiacichaohrievacíchzariadení,ventilátorov
-nesmiesaumiestniťdocestyprúdiacehovzduchu,napr.priotvorenomokne
-nesmiesaumiestniťnatakémiesto,kdemôžebyťdymalebopara(napr.vkuchynivblízkostisporáka,rúry,vedľaohrievačavody...),vblízkostifajčiarskejmiestnosti
-namiestasvysokýmobsahompary(napr.bezprostrednenadumývadlo,vaňu,práčky...)
-vgaráživblízkostivytvoreniavýfukovýchplynov
Uvedeniedoprevádzky
1.Definujtepodľahoreuvedenépodmienkymiestoprístroja!
2.Pripevnitezadnýkrytnapredpokladanémiesto!
3.Zasuňteprístrojdodržiaku!
4. Pripojte prístroj k elektrickej sieti! V tomto prípadezvuková indikácia a LED (2) kontrolka začne blikať - na 3 s. sa rozsvieti, 1s. zhasne. Tá indikácia signalizuje správnu
funkciuprístroja.Po3-5min.jeprístrojprevádzkyschopný!
Testovanie,samodiagnostika
TestovanieCOsnímačanavrhujemespustiťpriprvomprevádzkovaní, pristálehofungovania razzatýždňa. Stlačtepočas1-2 sec.COtesttlačidlo(6).LED kontrolkapre
indikáciuprítomnostiCO(3)3-krátzažiaričerveneaprístrojvydáva3krátkyzvukovýsignál.
Režim prítomnosti plynu nevieme testovať pomocou tlačidla, len napr. nepripáleným zapaľovačom. Držte zapaľovača na 5 cm od otvoru snímača plynu (5), a
pustiteplynpočaspársec.dootvoru.VtedyprístrojvydávazvukovýsignálaLEDkontrolkapreindikáciuprítomnostiplynu(4)začneblikať.Dovtedyzostanetak,
kýmprístrojsignalizujekoncentráciuplynu.Akdetektoružnecítiplyn,vrátisadozákladnéhorežimu.
Netestujte prístroj iným spôsobom (napr. priamym fúknutím plynu do prístroja), lebo sa môže znečistiť senzor prístroja. Pri normálnom použití je
životnosťsenzora5rokov.

COG01
detektorprítomnostioxiduuhoľ natéhoaplynu
Prevádzkovanie,alarm
VzákladnomstavesvietiLEDkontrolkafungovania(2).PočassnímaniaCOprizvukovomsignálečervenáLEDkontrolkapreindikáciuprítomnostiCO
(3) začneblikať. Počas snímaniaplynu červenáLED kontrolkapre indikáciuprítomnosti plynu(4) začne blikať.Počas fungovaniaCO snímačv určitom
časerevizujeprevádzkovanie,vtedyLEDkontrolkapreindikáciuprítomnostiCO(3)počasniekoľkosec.svietivzelenejfarbe.
PrevádzkaLEDkontroliek:
Dôležitéinformácie
Môžesastať,žeplynktorýsaobjavívinejčastibudovysanedostanevčasksenzoru,abyupozorniltýchktorísanachádzajúvbudove (napr.kvôlizatvorenýmdverám).
COsenzorneupozorníokamžitenanebezpečenstvo, vprípade aksanenachádzapriamo vtejmiestnostikde vzniklonebezpečenstvo.Ajv tomtoprípadesignalizujelen poprekročení
hranicekoncentrácieplynu.Nesnímateplotu,dym,plameňalebosvetlo
Môžusavyskytnúťtakýprípad,keďsaplynnedostanevpotrebnomčaseksenzoru,týmsanezabezpečípotrebnýčasnauniknutie.
Nezaručuje sa, že vie upozorniť v každom prípade každého. Silnú signalizáciu môže stlmiť iný zvuk, napr. počúvanie hudby, alebo sluchovo postihnuté osoby ťažšie zbadajú
signalizáciu. Nevieupozorniťosobypodvplyvomalkoholualiekov.Vtakýchtoprípadoch,podľapotrebyumiestnitešpeciálnedetektoryplynu.
Preminimalizovanievytvorenéhonebezpečenstva,okamžitetrebazobraťnavedomiepoplach,a vhodnereagovaťnato.Musísaidentifikovaťnebezpečenstvo,musísavyvetraťapri
ohrozeníživotatrebabudovuopustiť.Otvortevšetkyoknáadvere!Upozornitevšetkydotyčnéosoby.Akmátemožnosťvypnitepravdepodobnéchybnézariadenie!
Priuvedenído prevádzkyvysvetlite členomrodiny,ako jepotrebnékonaťprimožnom poplachu,upresnite siprípadnéúnikovécesty. Zostaňtepokojný,ačímskôropustitebudovu,av
prípadepotrebyzavolajtezáchrannúslužbuapožiarnikov!
Tento prístroj nieje profesionálne bezpečne prevádzkový, nezaručuje záchranu života pri úniku plynu. Nenahradzuje ostatnépotrebné ochranné, preventívne opatrenia a uzavretie
poistení.Tojeúlohouobývajúcich.
VprípadepoplachupočasVašejneprítomnostiskontrolujtezariadenievoVašombyteodborníkom!
Zkrytuprístrojasaodporúčaaspoňrazzamesiacodstrániťprach,nečistotu,zostatkyhmyzu.Nesmiesazamaľovať,adbajtenato,abysadoprístrojanedostaliúlomkyzosteny,kúsky
omietky. K pravidelnému čisteniu použite mäkký štetec, utierku a vysávač. Ubezpečte sa o prechodnosti vetracích otvorov! Prístroj vo vnútri netreba čistiť, je zakázané prístroj
rozoberať!
Výrobokjevhodnýibanavnútorné,domácepoužitie.Nevystavujtepriamemutepelnémužiareniualeboslnečnémužiareniu!
Technickéúdaje
typdetekovanéhoplynu: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . oxiduhoľnatý(CO),zemnýplyn(metánCH4),propán(C3H8),bután(C4H10)
typdetektora:.........................................................................................elektro-chemický
očakávanáživotnosťdetektora:...................................................................................5rokov
0 0
okolitáteplota:............................................................................................-10C–50C
okolitávlhkosť:..............................................................................................10–95%
hlasitosťsignalizácie:.....................................................................................min.85dB/3m
úrovnepoplachu(koncentrácia/trvanie):....................................................................200ppm(30sec)
napájanie:..............................................................................................230V~/50Hz
rozmery:.............................................................................................115x72x41mm
LED kontrolka pre indikáciu prítomnosti CO LED kontrolka pre indikáciu prítomnosti plynu
Červená Zelená Žltá Červená Zelená Žltá
Indikácia prítomnosti CO Bliká
Indikácia prítomnosti plynu Bliká
Chyba CO detektoru Bliká
Chyba plyn detektoru Bliká

COG01
•detectează şiavertizează asupraprezenţei monoxiduluidecarbon (CO),care esteinodor şiincolor,precum şia gazelorutilizateîngospodărie
(PB,gazmetan)
•nu necesitămontajşiîntreţinere,poatefipusînfuncţiuneimediat
•sensibilitateridicată,detecteazăconcentraţiideCOîncepânddela200ppm
•avertizaresonoră(min.85dB)
•indicatoaredestarecuLED
•cabludealimentarecuolungimede1,4m
•alimentare:230V~/50Hz
Componenteleaparatului:
1.Difuzor
2.LEDdeverificareafuncţionării
3.LEDdeverificarepentrudetectareadeCO
4.LEDdeverificarepentrudetectareadegaze
5.Orificiupentrudetectareadegaze
6. Dispozitiv de fixare
7. Buton de testare CO
8. Cablu de alimentare
9. Urechi de fixare
DetectorulCOG 01poate detectamonoxidul decarbon şigazele utilizateîn gospodărie(gaz metan(CH4), precumşi propan(C3H8) şibutan (C4H10)îmbuteliat) cuajutorulcelor doi
senzori integraţi. În vederea asigurării fiabilităţii, senzorul CO şi componentele electronice sunt dotate cu o funcţie de autotestare. LED-urile de verificare oferă informaţii
corespunzătoarefiecăreistări.Alarmasedeclanşeazăcumultînaintecaconcentraţiadegazsăpunăînpericolviaţacelordingospodărie.
Amplasareaaparatului
Aparatulpoate detectamonoxidulde carbon(CO)şigazul metan,precumşipropanul/butanul. Laamplasareaaparatuluitrebuie avutînvedere naturapericoluluifaţăde caredorimsă
neprotejămînprimulrând.
Densitateamonoxiduluidecarbon coincidecuceaaaeruluicald,motiv pentrucareînălţimeaidealădeamplasarea aparatuluiestede1,5 metridelanivelulpodeleişila minim1,8metri
delaaparatulmonitorizat.Nu-lamplasaţilamaipuţinde30centimetridecolţurileîncăperii!Înacestmodaparatulvamăsuraconcentraţiaefectivăagazelorînîncăpere.
Detectorultrebuie amplasatîn primulrândînapropierea aparatelorcare genereazăprodusedeardere întimpul funcţionării.Oriceprocesde ardereincompletă prezintăpericolpentru
căformeazămonoxiddecarbon:
-reşoucugaz,plită,convector degaz,boiler cugaz,cazan cugaz,aparat deîncălzirecu gaz,sobă,sobă cuulei,sobă culemnsaucucărbune,cuptor grill,fumulde ţigară,fumul
emisdeautoturisme…
Încazulînfundăriihornuluisaudacăvântulbate dindirecţienefavorabilă,produsele dearderepotfireintroduseînlocuinţă.Concentraţii periculoasepotaparelângă cazanulconectatla
horn şi lângă celelalte aparate, precum şi la orificiile de ventilare din partea de jos a cazanului. Acelaşi lucru se poate întâmpla şi în cazul unei hote montate deasupra aragazului.
Ferestreleşiuşilemoderneasigurăoizolaţieexcelentă,darnumaipermitventilaţianaturalăalocuinţei,aşacumseîntâmplaîntrecut.
Atenţie!Aparatulsemnaleazăacumulareauneiconcentraţiipericuloaseamonoxiduluidecarbondoarpentruîncăpereaîncareesteamplasat!Monoxiduldecarbonpoatesăfieprezent
şiînalteîncăperi!
Greutatea specifică a gazelor de uz casnic diferă semnificativ. Trebuie stabilit monitorizarea cărui material se are în vedere, iar în funcţie de acest lucru, aparatul trebuie amplasat
deasuprapodeleisausubplafon.În ambelecazuri,laturacea maiapropiatăaaparatuluitrebuiesă fielacelpuţin 30cmdepodeasaude plafon.Gazulmetaneste maiuşordecâtaerul
şi, dinacest motiv, semişcă în sus.În acestcaz, detectorul trebuieamplasat subplafon. Propanul/butanul estemai greu decâtaerului, deaceea aparatul trebuieamplasat deasupra
podelei.Pecâtposibil,esterecomandatcaaparatulsăfiemontatpeunperetelateral.
Laamplasareaaparatuluiţineţicontdeurmătoarele:
Pentruasigurareauneifuncţionărifiabileaaparatului,trebuieevitateurmătoarelecondiţiidemediu:
0 0
-temperaturidesub-10 Csaudepeste50 C;
-aerumed,aburit,prăfuit,murdar,impur;
-locuriînspatelemobilieruluisauaperdelelor;
-înimediataapropiereaaparatelorderăciresaudeîncălzire,lângăventilatoare;
-nu-lamplasaţiîncaleacurenţilordeaer,deex.lângăouşăsauungeamdeschis;
-nu-lamplasaţiînlocuriunde,înmodnatural,poatefifumsausepotformaaburi(deex.,înbucătărieînapropriereaaragazului,apliteisauaîncălzitoruluideapă...);înapropierea
locurilordefumat;
-înlocuricuumiditateridicată(deex.,imediatdeasuprachiuvetelor,lângăcăzidebaiesaucabinededuş,înapropriereaaparatelordespălat…);
-înapropriereaemisiilordegazeprodusedemotorulautoturismelorîncazulîncareleporniţiîngaraj.
Punereaînfuncţiune
1.Stabiliţiloculaparatuluiînconformitatecuceledescrisemaisus!
2. Fixaţi cu şuruburi capacul din spate la locul dorit.
3. Introduceţi aparatul în elementul de fixare.
4. Conectaţi senzorul la reţea. În acest moment LED-ul (2) care semnalizează funcţionarea va emite un semnal sonor şi va începe să lumineze intermitent – va lumina 3
secunde, se stinge 1 secundă.Acest lucru arată începerea funcţionării normale. După 3-5 minute aparatul este gata de funcţionare.
Testareşiautodiagnoză
Se recomandă să efectuaţi testarea senzorului CO în momentul punerii în funcţiune, apoi săptămânal, în cazul în care aparatul funcţionează în continuu. Ţineţi apăsat
butonul detestare CO (6)timp de 1-2secunde. LED-ul (3)de verificare pentrudetectarea monoxidului decarbon va luminaintermitent de 3ori, iar aparatulva emite 3
semnalesonore.
Funcţiadedetectareagazelornusepoatetestacuajutorulunuibuton.Puteţiefectuaacestlucrucuuninstrumentcareemiteocantitatemaimicădegaz(deex.,cu
o brichetă neaprinsă). Ţineţi bricheta la 5 cm de orificiul senzorului de gaz (5) şi lăsaţi să intre gazul din brichetă în orificiu timp de câteva secunde. În acest
moment, aparatul va emite un semnal sonor, iar LED-ul (4) de verificare pentru detectarea gazelor începe să lumineze intermitent. Acesta continuă să
luminezepânăcândaparatuldetecteazăprezenţagazului.Înmomentulîncaregazulsedisipează,aparatulrevinelastareadebază.
Nu testaţi aparatul prin alte proceduri (de ex., suflând direct fumîn orificiu) pentru că senzorul se poate umple de impurităţi. În condiţii normale de
utilizare,duratadeviaţăasenzoruluiestede5ani.
detectordemonoxiddecarbonş igaz

COG01
detectordemonoxiddecarbonş igaz
Funcţionareşisemnalizare
Înstarea debază valumina LED-ul(2) deverificare afuncţionării. Încazul încare aparatuldetecteazăprezenţa monoxiduluide carbon,LED-ul (3)de
verificare a CO începe să lumineze intermitent. În cazul în care aparatul detectează prezenţa gazelor, LED-ul (4) de verificare a gazelor începe să
lumineze intermitent. În timpulfuncţionării normale, senzorul COal aparatului efectuează periodicautotestări. În acest caz,LED-ul (3) de verificarea CO
lumineazăintermitentînverdetimpdecâtevasecunde.
FuncţionareaLED-urilordeverificare:
Importantdeştiut
Sepoateîntâmplacagazulapărutîntr-unpunctmaiîndepărtatalclădiriisănuajungăîntimpladetectorpentruaalertalocatarii(deex.,dincauzauşilorînchise).
Senzorul nuavertizează imediat asuprapericolului, decât dacăgazul apareîn aceeaşi încăpereunde esteamplasat aparatul. Dar, chiarşi în acestcaz, alarma estedeclanşată doar
dacă concentraţiagazului depăşeşte limitaadmisă. Aparatulnu poate detecta căldura,fumul sau lumina. Sepoate întâmplaca gazul sănu ajungă destul derepede la detector şisă
poatăasiguratimpsuficientpentruaevacuaîncăperea.
Nuse poategarantacăaparatul vadeclanşa alarmaîn toatesituaţiile şică vaavertiza toatepersoanele încauză. Semnalulsonor poatefi acoperitde altezgomote (deex., demuzică)
saupoatefiperceput maigreudepersoanelecudeficienţedeauz.Nupoate avertizapersoaneleaflatesubinfluenţaunormedicamentesauaalcoolului. Înacestecazuripoatefinevoie
demontareaunordetectoarespecialedegaz.
Pentru a minimaliza pericolul, alarma trebuie percepută imediat şi trebuie să reacţionaţi rapid şi în mod corespunzător la ea. Trebuie să identificaţi sursa de pericol, să aerisiţi şi să
părăsiţiclădireadacăviaţaDvs.esteînpericol.Deschideţitoateuşileşiferestrele!Anunţaţitoatepersoaneledinclădire!Dacăputeţi,opriţiaparatulpecare-lsuspectaţicăs-adefectat!
Lapunereaînfuncţiuneexplicaţimembrilordefamiliecumtrebuiesăprocedezeîncazuldeclanşăriialarmeişistabiliţiînprealabilposibilelecăideevacuare.
Rămâneţicalmi,evacuaţiclădireacâtmairepedeşi,dacăestenevoie,anunţaţisalvareaşipompierii!
Acestaparatnuesteproiectatpentruutilizareprofesionalăşi nugaranteazăsalvareapersoanelorîncazul unorscurgeridegaze.Nuînlocuieşte aplicareaaltormodalităţi deprotecţieşi
niciîncheiereaasigurărilorobişnuite.Acestelucruricadînsarcinalocatarilor.
Încazulîncareînlipsadumneavoastrăs-adeclanşatalarma,solicitaţiverificareaaparatuluidecătreunspecialist!
Serecomandă ştergereaprafului, aimpurităţilor,a rămăşiţelordeinsecte celpuţin odatăpe lună.Esteinterzisă vopsireaaparatului. Nulăsaţimolozul saubucăţilede peretesăajungă
înaparat.Pentrucurăţareaperiodicăaaparatuluiputeţifolosiopensulă,ocârpămoalesauunaspirator.Verificaţicăgrileledeventilarenusuntblocate!Aparatulnutrebuiesăfiecurăţat
îninterior.Esteinterzisădemontareaacestuia!
Aparatulesteconceputexclusivpentruutilizareînspaţiiinterioareşiuzcasnic.Feriţiaparatulderazelesolaredirecteşisurseledecăldură!
Datetehnice
tipulgazuluidetectat:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . monoxiddecarbon(CO),gazmetan(CH4),propan(C3H8),butan(C4H10)
tipulsenzorului:..........................................................................................electro-chimic
duratadeviaţăasenzorului:........................................................................................5ani
0 0
temperaturaambientală: ...................................................................................-10C–50C
umiditateaambientală:........................................................................................10–95%
nivelulsonor:...........................................................................................min.85dB/3m
limitadedeclanşareaalarmei(concentraţie/durată):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200ppm(30secunde)
alimentare:.............................................................................................230V~/50Hz
dimensiuni:...........................................................................................115x72x41mm
LED de verificare pentru detectarea de CO LED de verificare pentru detectarea de gaze
Roşu Verde Galben Roşu Verde Galben
Detectare CO Luminează intermitent
Detectare gaz Luminează intermitent
Defecţiune la senzorul CO Luminează intermitent
Defecţiune la senzorul de gaz Luminează intermitent

senzorugljenmonoksidaigasa
COG01
•detektujebezmirisnibezbojniugljenmonoksid(CO),igasovekojisekoristeudomaćinstvu(PBizemnigas)
•jednostavnaupotrebabezmontažeiodržavanja
•velikaosetljivost,većod200ppmCOkoncentracije
•zvučnisignal(min.85dB)
•LEDindikator
•priključnikabel1,4m
•napajanje:230V~/50Hz
Deloviuređaja:
1.Zvučnik
2.LEDindikatorrada
3.LEDindikatorprisustvaCO
4.LEDindikatorprisustvagasa
5.Otvorsenzoragasa
6. Nosač
7. CO test dugme
8. Priključni kabel
9. Ušice za fiksiranje
Uređaj COG01 uz pomoć dvaugrađena senzora detektujeprisustvo ugljenmonoksida igasove koji se upotrebljavaljuu domaćinstvima (zemnigas, metan(CH4)), iflaširani propan
(C3H8)butan(C4H10)gasove.RadibezbednogradaCOsenzorsaelektronikomposedujeautomatskutestfunkciju.LEDindikatoruvekdajeadekvatnuinformacijuotrenutnomrežimu
rada.Alarmćeseoglasitiprenegoštobikoncentracijagasadostiglakritičannivoopasanpoživot.
Postavljanjeuređaja
Uređaj je sposoban dadetektuje CO, zeni gas (metan), odnosnoflaširani propan-butab gasove. Prilikom montaže prvobitnotreba da znate kojigas može da budeprisutan u vašem
domaćinstvu.
Gustina ugljen monoksida je slična gustini toplog vazduha stoga je idealna visina za postavljanje od poda min. 1,5m a razdaljina od praćenog uređaja ne sme biti više od 1,8m. Ne
postavljaljteblizućoškova(min.30cm)!Samoćeuovomslučajuuređajrealnoraditiireagovatinavreme.
Uređaj setreba postavitipre svega ublizinu takvihuređaje kojimogu daproizvedu pojavu neželjenihgasova. Svakonepravilnog sagorevanjaprouzrokuje velikukoncentraciju ugljen
monoksida:
-gasnikotlovi,gasništednjaci,gasnegrejalice,gasnibojleri,gázkazán,gázpeći,kamini,uljnepećiipećinačvrstogorivo,izduvnigasoviautomobila…
Zbog začepljenja dimnjaka, loših vremenskih uslova ili oštećenja kazana može da se desi da se gasovi stvaraju prilikom gorenja vatrete u stambenom prostoru. Smrtonosni ugljen
monoksid može da se pojavi i kod spojeva kazana, otvora za čišćenje dimnjaka itd. Slična je situacija i iznad gasnih štednjaka. Današnji savremeni prozori i vrata onemogućavaju
prirodnoprovetravanjekaokodzastarelihprozoraivrata.
Pažnja!Dometuređajajeograničenasamonaprostorijuukojojjesmešten!Bezobziranatoudrugimprostorijamamožedabudeprisutanugljenmonoksid!
Različita je gustina gasova koji se upotrebljavanju u domaćinstvu. Uređaj se postavlja u zavisnosti od toga koju vrstu gasa želimo pratiti. Za zemni prirodni gas senzor treba da je
postavljen oko 30cm od plafona prostorije dok kod praćenja propan-butan flaširanog gasa senzor se postavlja u blizini poda. Određivanje položaja senzora izuzetno utiče na njenu
preciznostpriradu.Pomogućnostisenzormontirajtenasporednizid,nenazidnakojojsenalazinpr.gasnikotao.
Senzornikadanemontirajteućoškove!
Prilikommontažeobratitepažnjunasledeće:
Radivećebezbednostitrebaizbegavatisledećeradneuslove:
0 0
-temperatureispod-10 Cilivećeod50 C;
-vlažne,prašnjaveprostorije;
-izazavesainameštaja;
-trebaizbegavatiblizinugrejnihirashladnihtela,ventilatora;
-nepostavjajteublizinuvrataiprozora;
-nepostavjajtenamestagdejeprirodnimputemprisutanugljenmonoksid;
-nepostavjajteuprostorijegdejevelikakoncentracijapare(uneposrednublizinuvešmašina,ublizunutuša...)
-nepostavjajteugaraže,uneporedublizinuizduvnihgasova.
Puštanjeurad
1.Premagoreopisanomodreditepozicijuuređaja!
2. Montirajte nosač na odabrano mesto!
3. Postavite uređaj na nosač!
4. Uključite uređaj u struju! Začuće se zvučni signali i LED dioda (2) počeće treptati – 3 sekunde svetli, 1 sekundu je ugašen, ovo ukazuje na pravilan rad uređaja, nakon
isteka 3-5 minuta uređaj je spreman za rad.
Testiranje,diagnostika
TestiranjeCOsenzoratreba izvršitinakon uključenjairadiveće bezbednostiako seuređajkonstantnokoristi svakenedelje jednom.Zatestiranje držitetaster „COtest”
(6)pritisnuto1-2sekunde.LEDindikatorCOprisutnosti(3)ćedatrepne3putaizačučese3kratkazvučnasignala.
Senzorgasase nemožetestirati elektronskimputem,za testiranjekoristitemalukoličinugasa(primermeupaljeni upaljač).Upaljačpribližite senzorugasa(5)oko
5 cm, pustite gas par sekundi u otvor na uređaju. LED indikator prisustva gasa (4) će početi treptati i začuće se zvučni signal. Alarm će biti aktivan dok je
koncentracijagasavećaoddozvoljene,nakonalarmiranjauređajćeopetbitiupripravnosti.
Netestirajteuređajnadruginačin(duvajućidimnanju),tomožedauprljasenzor.Prinormalnimuslovimaradavektrajanjasenzorajeokopetgodina.

Rad,alarm
UosnovnompoložajuLED indikatorrada(2)trebadasvetli.UslučajuCOalarmiranja LEDdiodaCOsenzoratrepticrveno.Ako jeupitanjuzemniiliPB
gas, počećetreptati LED diodasenzora gasa (4).Prilikom konstantne upotrebe,s vremena navreme uređajvrši autodiagnostiku iu tom slučajupali se
LEDdioda(3)COsenzorakojautomslušajusvetlizelenombojomparminuta.
RadLEDindikatora:
Bitnojeznati
Možedasedesidagasizdaljihdelovazgradenedođedosenzoranavremeinealarmiraukućane.(primer:zatvorenavrata).
Alarm seneće oglasitiodmah, semako opasnostnije utoj prostoriji. Iu tom slučaju alarmirasamo ako koncentracija gasadostigne kritični nivo. Senzorne reaguje na toplotu,dim ili
vatru.Možedasedeseslučajevidakoncentracijagasanesitgnedovoljnobrzodosenzoraineomogućavaranuevakuacijuzgrade.
Nijezagarantovanoalarmiranjesvihugroženihosoba.Jakezvučnesignalemogudaupijudrugizvuci(slušanjeglasnemuzikeitd.)ilijenemoguraspoznatiosobesaoštećenimsluhom,
mogućejedaseosobepoduticajemlekovaialkoholanemogubitialarmiraninavreme.Zaspecijalneuslovemontirajtespecijalnealarmezagas.
Uslučaju opasnostitreba seponašati primerenoi staloženo,trebareagovati naadekvatan naćin:trebalocirati uzrok,treba provetritiprostorije,po potrebinapustiti objekat.Otvorite sve
prozoreivrata!Obavestitesveugrožene!Akosteumogućnostiisključiteuređajkojijeuzrokprisustvugasa!
Prilikommontažeobjasnitesvimukućanimapostupkeuslučajualarma,popotrebiodaberitemaršutuevakuacije.
Prilikomalarmabuditemirniištoprenapustiteobjekat.Popotrebizovitehitnupomoćivatrogasce!
Ovajuređajnijezaprofesionalnuupotrebunedajepotpunusigurnost,negarantujealarmiranje.Negarantujeostalebezbedonosneuslove,tojezadatakukućana.
Nakonalarmaupraznomstanu,uzroketrebadaproveravajustručnalica!
Poželjnosemesečnočišćenjeuređajakojiseradimekanomčetkom,ubrusom,usisivačem.Obratitepažnjudaništaneupadneuuređaj.Uređajjezabranjenorastavljati!
Isključivojepredviđenazazetvoreneprostorijedomaćinstva.Uređajštititeoddirektnoguticajasuncaitoplote!
Tehničkipodaci
vrstagasanakojireagujeuređaj: . . . . . . . . . . . . . . . . . . . . . . . . . . . ugljenmonoksid(CO),zemnigas(metanCH4),propan(C3H8),butan(C4H10)
tipsenzora:............................................................................................elektro-hemijski
radnivekuređaja:.............................................................................................5godina
0 0
temperaturaokolinezarad:.................................................................................-10C–50C
vlažnostvazduhaokolinezarad:.................................................................................10–95%
zvučnisignal: ..........................................................................................min.85dB/3m
nivoalarmiranja(koncentracija/vremenskiinterval): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200ppm(30sekundi)
napajanje:..............................................................................................230V~/50Hz
dimenzije:............................................................................................115x72x41mm
senzorugljenmonoksidaigasa
COG01
LED dioda CO senzora LED dioda senzora gasa
Crveno Zeleno Žuto Crveno Zeleno Žuto
CO prisustvo Trepti
Prisustvo gasa Trepti
Greška CO senzora Trepti
Greška senzora gasa Trepti

COG01
•zaznavabrezvonja,brezbarvniogljikovmonoksid(CO),inplinekateriseuporabljajovgospodinjstvu(PBinzemeljskiplin)
•enostavnauporababrezmontažeinvzdrževanja
•velikaobčutljivost,žeod200ppmCOkoncentracije
•zvočnisignal(min.85dB)
•LEDindikator
•priključnikabel1,4m
•napajanje:230V~/50Hz
Delinaprave:
1.Zvočnik
2.LEDindikatordela
3.LEDindikatorprisotnostiCO
4.LEDindikatorprisotnostiplina
5.Odprtinasenzorja
6. Nosilec
7. CO test gumb
8. Priključni kabel
9. Uhice za fiksiranje
Naprava COG 01 s pomočjo dveh vgrajenih senzorjev zaznava prisotnost ogljikovega monoksida in plinov kateri se uporabljajo v gospodinjstvih (zemeljski plin, metan (CH4)), in
ustekleničenepropan (C3H8)butan (C4H10)pline. Zaradivarnega delovanjaCOsenzor zelektroniko vsebujeavtomatskotest funkcijo.LED indikatorvedno dajeustreznoinformacijo
otrenutnemnačinudela.Alarmiranjesevključuježemnogoprej,predenbikoncentracijaplinabilaškodljiva.
Postavitevnaprave
Naprava je sposobna da zaznava CO, zemeljski plin (metan), oziroma ustekleničene propan-butan pline. Pri montaži je prvotno treba vedeti kateri plin je lahko prisoten v vašem
gospodinjstvu.
Gostotaogljikovegamonoksidajepodobnagostotitoplegazraka,zatorejjeidealnavišinazapostavljanjeodtalmin.1,5marazdaljaodspremljajočenapravenesmebitivečjaod1,8m.
Nepostavljajteblizuvogalov(min.30cm)!Samovtemprimerubonapravarealnodelovalainreagiralapravočasno.
Napravasemorapostavitipredvsemvbližinotakšnihnaprav,katerelahkoproizvedejoprisotnostneželjenihplinov.
Vsakonepravilnoizgorevanjepovzročavelikokoncentracijoogljikovegamonoksida:
-plinskikotli,plinskištedilniki,plinskigrelci,plinskibojleri,gázkazán,plinskepeči,kamini,oljnepečiinpečinatrdogorivo,izpušnipliniavtomobilov…
Zaradizamašitvedimnika,slabihvremenskihpogojevalipoškodbe kotlaselahkozgodidasepliniustvarajo prigorenjuognjavstanovanjskemprostoru.Smrtonosniogljikov monoksid
se lahko pojavi tudi pri spojih kotlov, odprtin za čiščenje dimnika itd. Podobna je situacija tudi nad plinskimi štedilniki. Današnja sodobna okna in vrata onemogočajo naravno
prezračevanjekotprizastarelihoknihinvratih.
Pozor!Dometnapravejeomejensamonaprostorvkateremjenameščen!Brezoziranatojevdrugihprostorihlahkoprisotenogljikovmonoksid!
Različnajegostota plinovkateri seuporabljajovgospodinjstvu.Naprava sepostavlja vodvisnostiodtegakatero vrstoplina želimospremljati.Zazemeljskinaravniplinmora bitisenzor
postavljen približno 30cm od stropa prostora, a pri spremljanju propan-butan ustekleničenega plina se senzor postavlja v bližino tal. Odrejanje položaja senzorja zelo vpliva na
natančnostdelovanjanaprave.Pomožnostisenzormontirajtenavzporednosteno,nenastenonakaterisenahaja npr.plinskikotel.
Senzornikolinemontirajtevvogale!
Primontažiboditepozorninasledeče:
Zaradivečjevarnostisejetrebaizogibatisledečimdelovnimpogojem:
0 0
-temperaturepod -10 Calivečjeod50 C;
-vlažni,prašniprostori;
-izzazavesinpohištva;
-trebaseje izogibatibližinigrelnihinhladilnihteles,ventilatorjev;
-nepostavjajtevbližinovratinoken;
-nepostavjajtenamestakjerjenaravnoprisotenogljikovmonoksid;
-nepostavjajtevprostorkjerjevelikakoncentracijapare(vneposrednobližinopralnihstrojev,vbližinotuša...)
-nepostavjajtevgaraže,vneposrednobližinoizpušnihplinov.
Zagon,delovanje
1.Gledenazgoraj opisanoodreditepozicijonaprave!
2. Postavite nosilec na izbrano mesto!
3. Postavite napravo na nosilec!
4. Vklopite napravo v elektriko. Zaslišali boste zvočni signal in LED dioda bo začela utripati (2) – 3 sekunde sveti, 1 sekundo je vgašen, to kaže na pravilno delovanje
naprave, po izteku 3-5 minut naprava je pripravljena za delovanje.
Testiranje,diagnostika
Testiranje CO senzorja je treba izvršitipo vklopu in zaradi večje varnosti če se naprava konstantno uporablja enkrat tedensko. Za testiranje držite tipko „CO test” (6)
pritisnjeno1-2sekundi.LEDindikatorCOprisotnosti(3)boutripal3kratinzaslišalisebodo3kratkizvočnisignali.
Senzorplina sene moretestirati poelektronski poti,za testiranjeuporabljajte malokoličino plina(primer neprižganivžigalnik). Vžigalnikpribližajte senzorjuplina
(5)do5cm,pustiteplinparsekundv odprtinonanapravi. LEDindikatorprisotnostiplina(4)bozačel utripatiinzasliši sezvočnisignal.Alarmboaktiven doklerje
koncentracijaplinavečjaoddovoljene,poalarmiranjubonapravazopetvpripravljenosti.
Ne testirajte napravo na drugačen način (pihajoč dim na njo), to lahkoumaže senzor. Pri normalnih pogojihdelovanja doba obstojnosti senzorja je
okoli5let.
senzorogljikovegamonoksidainplina

COG01
senzorogljikovegamonoksidainplina
Delo,alarm
Uosnovnem položajuLED indikatordelovanja(2) morasvetiti. VprimeruCO alarmiranjaLEDdioda COsenzorja utripardeče.Vkolikor jeto zemeljski
aliPBplin,začneutripatiLEDdiodasenzorjaplina(4).Prikonstantniuporabi,občasnonapravavršiavtodiagnostikoinvtemprimeruseprižigaLEDdioda
(3)COsenzorjakateravtemprimerusvetizelenebarvenekajminut.
DeloLEDindikatora:
Pomembnojevedeti
Lahkosezgodidaplinizoddaljenihdelovzgradbenepridedosenzorjapravočasnoinnealarmirastanovalce.(primer:zaprtavrata).
Alarmsenebooglasiltakoj,samočesenahajavtemprostoruvkateremsepojaviplin..
Tudiv tem slučajualarmira samo ,če koncentracija plinadoseže kritični nivo. Ne alarmiraza požar,toploto, dim alisvetlobo. Lahko se zgodijo primerida koncentracija plina ne pride
dovoljhitrodosenzorjainneomogočazgodnjoevakuacijozgradbe.
Ni zagarantirano alarmiranje vseh ogroženih oseb. Močne zvočne signale lahko preglasijo drugi zvoki (poslušanje glasne glasbe itd.) ali pa je ne morejo razpoznati osebe s
poškodovanimsluhom,mogočejetudidaosebepodvplivomzdravilinalkoholanemorejobitialarmiranipravočasno.Zaspecijalnepogojemontirajtespecijalnealarmezaplin.
V primerunevarnosti seje trebaobnašati pomirjeno inzbrano, potrebnoje reagiratina ustrezennačin: potrebnoje lokazirativzrok, potrebno jeprezračiti prostore,po potrebizapustiti
objekt.Odpritevsaoknainvrata!Obvestitevseogrožene!Čeimatemožnostizključitenapravokaterajevzrokprisotnostiplina!
Primontažipojasnitevsemstanujočimpostopkevslučajualarma,popotrebiizberitenajkrajšopotevakuacije.
Prialarmiranjuboditemirniinčimprejzapustiteobjekt.Popotrebipokličiteprvopomočingasilce!
Tanapravanizaprofesionalnouporabonezagotavljapopolnovarnost,nezagotavljaalarmiranje.Nezagotavljaostalevarnostnepogoje,tojenalogastanovalcev.
Poalarmiranjuvpraznemstanovanju,morajovzrokepreverjatiusposobljeneosebe!
Zaželjenojemesečnočiščenjenapravekateroseizvajazmehkoščetko,prtičkom,sesalcem.Boditepozornidaničnepadevnapravo.Napravojeprepovedanorazstavljati!
Izključnojepredvidenazazaprteprostoregospodinjstva.Napravoščititepreddirektnimvplivomsoncaintoplote!
Tehninipodatki
vrstaplinanakateregareagiranaprava:. . . . . . . . ogljikovmonoksid(CO),zemeljskiplin(metanCH4),propan(C3H8),butan(C4H10)
tipsenzorja:..................................................................................elektro-kemični
delovnadobanaprave:..................................................................................5let
0 0
temperaturaokolicezadelo:......................................................................-10C–50C
vlažnostzrakaokolicezadelo:........................................................................10–95%
zvočnisignal:................................................................................min.85dB/3m
nivoalarmiranja(koncentracija/časovniinterval): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200ppm(30sekund)
napajanje:....................................................................................230V~/50Hz
dimenzije: .................................................................................115x72x41mm
LED dioda CO senzorja LED dioda senzorja plina
Rdeče Zeleno Rumeno Rdeče Zeleno Rumeno
CO prisotnost Utripa
Prisotnost plina Utripa
Napaka CO senzorja Utripa
Napaka senzorja plina Utripa

COG01
snímač COaplynů
• snímá a signalizuje přítomnost bezbarvéhoa nepáchnoucího kysličníku uhelnatého (CO) arovněž dalších plynů pro domácnosti (PB,zemní
plyn)
•nepotřebuježádnouinstalacianiúdržbu-okamžitěprovozuschopný
•velkácitlivost,signalizujeužod200ppmkoncentraceCO
•hlasitýpoplach(min.85dB)
•LEDindikacestavů
•síťovýpřipojovacíkabel1,4m
•napájení:230V~/50Hz
Částizařízení:
1.Reproduktor
2.LEDindikaceprovozu
3.LEDindikaceCO
4.LEDindikaceplynu
5.Otvorčidla
6. Upevňovací prvek
7. Tlačítko CO testu
8. Síťový kabel
9. Drážky pro zavěšení
COG 01 snímá přítomnost kysličníku uhelnetého a dalšíchplynů, používaných v domácnosti (zemní plyn, metan [CH4] z rozvodů nebo propan[C3H8] a butan [C4H10] z tlakových
láhví) pomocídvou samostatných čidel. Prodosažení co nejvyššíspolehlivosti máCO čidlo a elektronickyřízený samotestovací program.LED indikaceinformuje o všech funkčních
stavechpřístroje.Poplachnastáváještědříve,nežkoncentracekteréhokolivzplynůdosáhneživotunebezpečnouhranici.
Umístěnípřístroje
Čidla jsouschopna rozpoznatpřítomnost CO,zemního plynu (metanu)a proban-butanu.Při umísťovánísnímače musíme vzítv úvahu,proti jakémuohrožení se potřebujemechránit
přednostně.
Kysličníkuhelnatýmápodobnou hustotujakoteplývzduch, protoideálnívýškouproumístěnísnímačeje cca1,5mnad úrovnípodlahy,přičemžbymělbýtve vzdálenostialespoň1,8m
odsledovanéhozařízeníanejméně30cmodrohumístnosti!Jenomtakbudeměřithodnoty,relevantníprodanoumístnost.
Tentopoplachovýpřístroj sevprvnířadě musíumístitpoblížtakových zařízení,kterápři svémprovozu produkujíspaliny.Přikaždém procesuhoření snedokonalým spalovánímmůže
nastatnebezpečítvořeníkysličníkuuhelnetéhood:
-plynovýchtopidel,-sporáků,-konvektorů,-kotlů,-bojlerů,-krbů,naftovýchkamen,kamennatuhápaliva,grilovacíchzařízení,kouřezcigaret,výfukůmotorovýchvozidel…
Takév důsledkuucpání komínunebo nepříznivéhovětruse mohouspaliny zpětnýmtahem vracetdo obytnýchmístností. Vražednýplynsemůže objevitu kotlenebo jinýchspotřebičů,
napojenýchnakomín ataké ujeho spodníhočisticího otvoru.Podobně seto můžestát ukuchyňského odsavačenad plynovouvarnou deskou.Dnešní dokonaletěsnící oknaa dveře
neumožňujíminimálnípřirozenévětráníjakovdřívějšíchdobách.
Výstraha! Přístrojsignalizujenebezpečnoukoncentracikysličníkunuhelnatéhopouzevtémístnosti,kdejeumístěn!Nezávislenatommůžebýtplynijinde!
Měrnáhmotnost plynůpro domácnostije podstatněodlišná. Jenutnéserozhodnout, kterýz plynůbudeme chtítsledovat apodletohoumístit snímač- zdau stropunebo upodlahy-v
oboupřípadechmusíbýtnejbližšístranapřístrojevzdálena30cm(odstropunebopodlahy).Zemníplynjelehčíjakovzduch,stoupávzhůruaprotovtomtopřípaděumísťujemesnímač
podstrop.Proban-butanjenaopaktěžšíjakovzduch,klesádolůaprotovtomtopřípaděsnímačumísťujemeupodlahy.Pokudjetomožné,jeúčelnéinstalovatsnímačnabočnízeď.
Přiumístěnídbejtenásledujícíchpokynů:
Prospolehlivýprovozjepotřebnévyhnoutsenásledujícímokolnímpodmínkám:
0 0
-teplotapod-10 Cnebonad+50 C;
-přílišzatuchlé,vlhké,prašnéaznečištěnéovzduší;
-místozazávěsem,nábytkem;
-umístěníbezprostředněuchladicíchatopnýchzařízeníavedleventilátorů
-umístěnídocestyproudícíhovzduchu,např.udveříaoken,kterémohouzůstatotevřeny
-místo,kdejepřirozenýzpůsobempřítomenkouřnebopára(např.vedletopeniště,varnédeskysporáku,ohřívačevodyvkuchyni,v„kuřárně”prokuřákyapod.);
-umístěnídoprostorsvysokýmobsahemvodníchpar(např.přímonadmycídřez,vedlevany,sprchovacíhokoutu,pračky...atd.);
-umístěnívgarážipoblížzdrojevýfukovýchplynů.
Uvedenídoprovozu
1.Stanovtedlevýšeuvedenýchpodmínekmístoproumístnění!
2. Připevněte zádní kryt na předpokládané místo!
3. Zasuňte přístroj do držáku!
4. Připojte přístroj k elektrické síti! V tomto případě zvuková indikace a LED (2) kontrolka začne blikat – na 3 vtř. se rozsvítí, 1 vtř. zhasne. Tahle indikace signalizuje
správnou funkci přístroje. Po 3-5 min. je přístroj provozuschopen!
Testování,samodiagnostika
Doporučujese otestovatčidlo COhned pouvedení doprovozu apak 1xtýdně: Stlačtena 1-2sec. tlačítkoCO testu(6). IndikačníLED přístrojepro CO(3) napřístroji 3x
červeněbliknevdoprovodu3xkrátkéhozvukovéhosignálu.
Funkčnost čidla plynu se nedá testovat pomocí tlačítka, lze ji ale ověřit malým zdrojem úniku plynu (např. plynovým zapalovačem). Podržte zapalovač ve
vzdálenosticca5cmodsnímacíhootvoručidla abezškrtnutíněkolikrátvpusťtedoněhoplynpodobuněkolikavteřin.Přístrojzačnevydávatzvukovéznamení
a indikačníLED (4)plynového čidlazačne blikata topo celoudobu, pokterou snímá přítomnostplynu. Jakmilezdroj plynuodstraníte, signalizace ustanea
přístrojsepřestavídovýchozíhostavu.
Přístroj netestuje jiným způsobem (např. fouknutím cigaretového dýmu), mohlo by se tím zanést jeho čidlo. Při obvyklém užívání je životnost
senzorusnímačeodhadovánana5let.

COG01
snímač COaplynů
Provoz,poplach
Ve výchozím(základním) stavu svítíLED signalizace provozu.Po zjištění přítomnostiCO začne vdoprovodu zvukového signálučerveně blikatLED
signalizace CO(3), přizjištění plynubliká červeně LEDsignalizace plynu(4). Vdalším provozu vurčitých časovýchintervalech čidloCO znovu aznovu
měřípřítomnostCOvovzduší,vtomokamžikuponěkolikvteřinsvítízeleně.
ČinnostLEDsignalizací:
Důležitáupozornění
Můženastatsituace,kdysevevzdálenějšímístnostiunikajícíplynnemůževčasdostatksnímači(např.kvůlizavřenýmdveřím)aosobyvdomácnostitaknemohoubýtvčasvarovány.
Snímač nemůževčas upozornitna nebezpečí, pokudnení zdrojnebezpečí přímo vmístnosti, kdeje umístěn. Iv tomtopřípadě může jenomsignalizovat překročeníprahové hodnoty
koncentraceplynu propoplach, nakterou jenastaven. Neindikujeteplotu,dým, oheňnebo světlo.Mohou nastatsituace,kdy seplyn nedosátanevčas kesnímače aprotoby nemusela
býtzabezpečenadostatečnádobakúniku.
Nenízaručeno ževkaždémpřípadě budekaždý dostatečněvčas varován.I silnázvuková signalizacemůže býtpřehlušena jinýmhlukem, např.poslechemhudby,nebo jinerozpozná
osobasporuchousluchu.Rovněžnemusívarovatosobypodvlivemmedikamentůneboalkoholu.Protytopřípadynechejteinstalovatspeciálníplynovésnímače.
Pro minimalizaci vznikajícího nebezpečí se musí informace o poplachu získat včas, popř. je potřebné na ně správně reagovat. Okamžitě se musí větrat, musí být odhalen zdroj
nebezpečí,popřípadějenutnérychleopustitbudovu.Otevřetevšechnydveřeaokna!Ihnedinformujtevšechnyosobyvdosahu!Pokudmátemožnost,vypnětezařízení,kterébymohlo
býtvadné!
Přiuváděnídoprovozuinformujtevšechnyčlenydomácnosti,comajídělatpřipřípadnémpoplachu,určetesimožnéúnikovétrasy.
Zůstaňteklidníaleconejrychlejiopusťebudovu,ažpotépřípadněvolejtezáchrannouslužbuahasiče!
Provedení tohoto přístroje nemá profesionální provozní spolehlivost, v případě průsaku plynu nezaručuje záchranu života. Nenahražuje jiná obvyklá ochranná opatření a uzavření
obvyklýchpojistek.Tojeúkolemobyvatel.
Pokudnastanepoplachvevašínepřítomnosti,nechejtetoto(tato)zařízenízkontrolovatodborníkem!
Doporučujesekrytpřístrojealespoňjednouměsíčněutřítodprachu,ulpělýchnečistotapřípadnýchzbytkůhmyzuabrouků.Přístrojsenesmípřimalovánímístnostipřemalovatadbejte
abyse donějnedostaly úlomkyzdia omítky.Propravidelnou očistupoužijtejemný štětec,utěrkua vysavač.Ujistětese oprůchodnostivětracích mřížekpřístroje!Vnitřekzařízení není
potřebačistit,jehorozebíráníjezakázané!
Přístrojjeurčenpouzepropoužitívevnitřnímprostředídomácnosti.Nevystavujtejejpřímémusluncinebopůsobenísálavéhotepla!
Technicképarametry
druhindikovanéhoplynu: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kysličníkuhelnatý(CO),zemníplyn(metanCH4),propan(C3H8),butan(C4H10)
typčidla:..............................................................................................elektrochemický
přčedpokládanáživotnost:..........................................................................................5let
0 0
teplotaokolí:...........................................................................................-10Caž+50C
vlhkostvzduchuokolí: ........................................................................................10–95%
akustickáúroveňpoplachu:................................................................................min.85dB/3m
úroveň(koncentrace/dobatrvání)prospuštěnípoplachu: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200ppm(30sec.)
napájení:...............................................................................................230V~/50Hz
rozměry:.............................................................................................115x72x41mm
LED indikace přítomnosti CO LED indikace přítomnosti plynu
Červená Zelená Žlutá Červená Zelená Žlutá
Zjištěn CO Bliká
Zjištěn plyn Bliká
Vada čidla CO Bliká
Vada čidla plynu Bliká

COG01
detektorugljič nog-monoksidaiplina
• detektira i signalizira prisutnost ugljičnog-monoksida (CO) koji je bez boje i mirisa, odnosno plinove koji se koriste u domaćinstvima (propan
butan,zemniplin)
•nijegapotrebnomontirati,nitiodržavati,odmahsepuštaurad
•vrlosenzibilan,alarmiravećiznadkoncentracijeCOod200ppm
•glasnoalarmiranje(min.85dB)
•LEDsignalizatoristanja
•1,4mkablzanapajanje
•napajanje:230V~/50Hz
Dijeloviuređaja:
1.Zvučnik
2.LEDzaprikazivanjefunkcioniranja
3.LEDzadetektiranjeCO
4.LEDzadetektiranjeplina
5.Otvorzadetektiranjeplina
6. Element za montiranje
7. CO test tipka
8. Kabl za napajanje
9. Dio za fiksiranje
COG01sdvaposebnaugrađenasenzoradetektiraugljični-monoksidiplinovekojisekoristeudomaćinstvima(zemniplin,metan(CH4)),nadaljepropan(C3H8)ibutan(C4H10)kojise
puneuboce.Uciljupouzdanostisenzorielektronikaraspolažufunkcijomsamotestiranja.LEDdisplejdajeodgovarajućeinformacijeostanjuu svakomtrenutku.Alarmseuključujeprije
negolikoncentracijadostignesmrtonosnuvisinu.
Montiranjeuređaja
DetektordetektiraprisutnostCOizemnogplina(metan),nadaljepropan-butanplinove.Kodmontiranjatrebauzetiuobzirodkojeseopasnostiprvenstvenotrebazaštititi.
Ugljični-monoksidje sličnegustoće kaoi toplizrak, zatoje idealnavisina njegovogpostavljanja 1,5m mjerenood poda,i najmanje1,8 mod uređajakoji želimokontrolirati. Nesmije se
postavitibližeod30cmodkutovaprostorije!Naovajnačinćemodobitistvarnerezultatekodmjerenja
Uređaj seprvenstveno trebapostaviti ublizini onihuređaja prilikomčijegfunkcioniranja dolazido sagorljivihmaterijala. Kodsvakog procesasagorijevanja kojinije odgovarajućimože
doćidovanrednesituacijejernastajeugljični-monoksid:
- pećnica, ploča za kuhanje na plin, bojler na plin, kotao na plin, grijalica na plin, kamin, uljana peć, peć na sagorijevanje drva i ugljena, grill pećnica, dim cigarete, auspuh
automobilaimotora…
Uslijed zapušenja dimnjaka ili nepogodnih okolnosti vjetra materijali sagorijevanja se mogu vraćati u stambeni prostor. Pored kotla i ostalih uređaja koji su priključeni na dimnjak,
odnosno kodotvora za čišćenje nadnu dimnjaka možese pojavitismrtonosni plin.Sličan slučaj se možedesiti i kodaspiratora ukuhinji iznadradne ploče gdje jeugrađena pećnica.
Današnjiprozoriivratakojiizvrsnoizolirajuneomogućujuprirodnoprovjetravanjekojejeranijepostojalo.
Pozornost!Detektorsignaliziraprisutnostopasnekoncentracijeugljičnog-monoksidasamouonojprostorijigdjejepostavljen!Neovisnootomeplinmožebitiiudrugimprostorijama!
Specifičnatežina plinovaudomaćinstvuje uvelikoj mjerirazličita. Trebaodrediti kojematerijesemjere prvenstvenoiprematome trebauređajpostavitiiznad podaili ispodplafona –u
obaslučajana30centimetaratrebastajatirubuređaja.Zemniplinjelakšiodzraka,zatosepodiže,utomslučaju detektorsetrebapostavitiispodplafona.Propan-butanjetežiodzraka,
stogauređajtrebapostavitiiznadpoda.Pomogućnostitrebagapostavitinabočnizid.
Kodmontiranjatrebamovoditiračunaosljedećem:
Uinteresupouzdanogfunkcioniranjatrebaizbjegavatisljedećeokolnosti:
0 0
-temperaturanižaod-10 C,ilivišaod50 C;
-vlažan,prašnjav,prljav,zagađenzrak;
-mjestoizazastorainamještaja;
-neposrednablizinahladnjakuiliuređajuzagrijanje,poredventilatora;
-nesmijesepostavitinaputprotokazraka,npr.poredotvorenogprozoraivrata;
-nesmijesepostavitinamjestogdjedodimailiparemožedoćiprirodnimputem(npr.ukuhinjiublizinipećnice,poredgrijalicezavodu...);ublizinumjestazapušenje;
-namjestimagdjejevisokavlažnostzraka(npr.neposrednoiznadsudopera,poredkade,tuš-kabine,strojazapranjerublja)
-ubliziniauspuhaugaraži.
Puštanjeurad
1.Odreditemjestouređajapremagorenavedenom!
2. Fiksirajte stražnji dio na željeno mjesto!
3. Postavite uređaj u fiksirani dio!
4. Priključite senzor na mrežu! Tada počinje treperiti LED lampica (2) uz zvučni signal – 3 sekundi svijetli, 1 sekundu je isključena, tako pokazuje ispravno funkcioniranje.
Nakon 3-5 minuti uređaj je spreman za rad.
Testiranje,dijagnostika
Preporučuje sekontrolu vršiti kodpuštanja u rad inakon toga svakog tjedna.1-2 sekunde držitepritisnutu tipku za testiranje(6). LED za detektiranjeCO (3) će3 puta
trepnutiucrvenojbojiinakontogadati3kratkazvučnasignala.
Detektiranjeplinasene možetestirati uzpomoć neketipke većs jednimsredstvom kojeemitira plin(npr.upaljačkoji nijeupaljen). Držiteupaljač na5 cmod otvora
na detektoru(5) ipustite unjega plin nanekoliko sekundi.Tada uređajdaje zvučnisignal i LEDza signaliziranje plina(4) počinjetreperiti.Točini sve dotledok
detektiraplin.Kadatoprekine,vraćaseuosnovnostanje.
Uređaj ne treba na drugi način testirati (npr. upuhavanjem dima neposredno u uređaj), jer se može zaprljati senzor. Normalnim korištenjem vijek
trajanjasenzoraje5godina.

Funkcioniranje,alarmiranje
U osnovnom stanju LED za prikazivanjefunkcioniranja (2) svijetli. U slučaju detektiranja CO-a uz davanjezvučnog signala LED za signaliziranje
CO-a (3) počinje treperiti u crvenoj boji. U slučajudetektiranja plina LED za signaliziranje plina (4) počinje treperiti u crvenoj boji.Tokom normalnog
funkcioniranja senzor za detektiranje CO-a u određenim periodima vrši kontrolu i tada LED za signaliziranje CO-a (3) svijetli u zelenoj boji nekoliko
sekundi.
FunkcioniranjeLEDsignalizatora:
Bitneinformacije
Možesedesitidaplinkojisepojaviuudaljenimdijelovimaobjektanestignenavrijemedosenzoradaonupozoriljudekojisenalazeuobjektu(npr.zbogzatvorenihvrata).
CO detektorne signaliziramomentalno opasnost,izuzev uslučaju dado izvanrednesituacije dođebaš uprostoriji ukojoj jepostavljen. Iu tomslučaju uređajsignalizira teknakon što
koncentracija otrovnog plinaprijeđe graničnu vrijednost alarmiranja. Nedetektira toplinu, dim, plamen ilisvijetlost. Može doći do takvihslučajeva kada plinne dođe dovoljno brzo do
detektorainatajnačinneosiguradovoljnovremenazaeventualnuevakuaciju.
Negarantirase daće uređajusvakomslučajusve dotičneupozoriti naopasnost.Jačinu zvučnogsignala moženadjačatidrugabuka,npr.slušanjeglazbe, odnosnoosobesoštećenim
sluhomtežemoguprimijetitialarm.Uređajnemožeupozoritiosobekojesupodutjecajemlijekovaialkohola.Uovimslučajevimatrebainstaliratispecijalnesenzoreplina.
U interesu minimaliziranja nastale opasnosti, alarmiranje treba vrlo brzo primijetiti i brzo i na odgovarajući način reagirati. Treba identificirati izvor opasnosti, prostoriju provjetriti i u
slučajuopasnostipoživotpovućiseizobjekta.Otvoritesvavrataiprozore!Obavijestitesvedotične!Akoimatemogućnostiisključiteuređajkojijeeventualnoukvaru!
Kodmontiranjauređajaobjasnitečlanovimaobiteljištotrebajuučinitiuslučajualarmiranjauređaja,odrediteunaprijedmogućeputevespašavanja.
Ostanitesmireniiuštokraćemvremenunapustiteobjektizatimpozovitehitnupomoćivatrogasce!
Ovajuređaj nijeprofesionalno siguranuređaj,ne garantiraspašavanje životauslučaju curenjaplina.Ne zamjenjujeostale mjerepredostrožnostii sklapanjeuobičajenih osiguranja.To
jezadatakstanara.
Uslučajualarmiranjauvašemodsustvu,provjeritesvojeuređajesastručnomosobom!
S kućišta uređaja jepotrebno najmanje mjesečno očistiti prašinu, prljavštinu, ostatke insekata.Uređaj se ne smije prefarbati ipazite da u njegane upadnu otpaci sa zida, žbuke. Za
redovno čišćenje treba koristiti meku četku, krpu za brisanje i usisivač. Provjerite jesu li očišćene rešetke na ventilaciji! Unutarnjost uređaja se ne treba čistiti, uređaj je zabranjeno
rasklopiti!
Uređajjepogodanisključivozaunutarnjuuporabuudomaćinstvima.Uređajtrebačuvatiodneposrednihsunčevihzrakailitoplote!
Tehničkipodaci
Vrstaplinakojasedetektira:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . gljični-monoksid(CO),zemniplin(metanCH4),propan(C3H8),butan(C4H10)
Tipdetektora:..........................................................................................elektro-kemijski
Vijektrajanjadetektora:........................................................................................5godina
0 0
Temperaturaokoline: ......................................................................................-10C–50C
Vlažnostzrakaokoline:........................................................................................10–95%
Jačinazvučnogsignala:...................................................................................min.85dB/3m
Nivoalarmiranja(koncentracija/vremenskiperiod):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200ppm(30sekundi)
napajanje:..............................................................................................230V~/50Hz
dimenzije:............................................................................................115x72x41mm
COG01
detektorugljič nog-monoksidaiplina
LED za signaliziranje CO-a LED za signaliziranje plina
Crvena Zelena Žuta Crvena Zelena Žuta
Detektiranje CO-a Treperi
Detektiranje plina Treperi
Greška u CO senzoru Treperi
Greška u senzoru plina Treperi
Treperi


Eng.szám:S5998K833
®
Importálja: SOMOGYI ELEKTRONIC
9027 Győr, Gesztenyefa út 3. • www.sal.hu
Származási hely: Kína
í
UvoznikzaSRB:Elementad.o.o.
JovanaMikića56,24000SUBOTICA,SRBIJA
Tel:++381(0)24686270
www.elementa.rs
Zemlja uvoza: Mađarska • Zemlja porekla: Kina
Distributer zaSLO:ElementaElektronika d.o.o.
Osek7a,2235SvetaTrojica•tel–fax;+38627292024•Web:www.elementa-e.si
Državaporekla:Kitajska
Distribútor:SomogyiElektronicSlovenskos.r.o.
Záhradnícka10,94501Komárno,SK
Tel.:+421/0/357902400
www.salshop.sk
Krajina pôvodu: Čna
Importator:S.C.SOMOGYIELEKTRONICS.R.L.
J12/2014/13.06.2006C.U.I.:RO 18761195
Comuna Gilău, judeţul Cluj, România
Str. Principală nr. 52 Cod poştal: 407310
Telefon: +40 264 406 488 • Fax: +40 264 406 489
www.somogyi.ro
Ţara de origine: China
COG01
Table of contents
Languages: