Sony HK-PSU02 User manual

INSTALLATION MANUAL
1st Edition
DME PROCESSOR PACK
MVE-8000A-C
MVE-8000A
MULTI FORMAT DME PROCESSOR
HK-PSU02
MKE-8020A
MKE-8040A

MVE-8000A
!WARNING
This manual is intended for qualified service personnel only.
To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so. Refer all servicing to
qualified service personnel.
!WARNUNG
Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt.
Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um die
Gefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind bei
Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegeben
Wartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigung
dazu besitzen.
!AVERTISSEMENT
Ce manual est destiné uniquement aux personnes compétentes en charge de l'entretien. Afin de
réduire les risques de décharge électrique, d'incendie ou de blessure n'effectuer que les
réparations indiquées dans le mode d'emploi à moins d'être qualifié pour en effectuer d'autres.
Pour toute réparation faire appel à une personne compétente uniquement.
MVE-8000A Serial No. 10001 and Higher
HK-PSU02 Serial No. 10001 and Higher
MKE-8020A Serial No. 10001 and Higher
MKE-8040A Serial No. 10001 and Higher

MVE-8000A 1 (P)
Attention-when the product is installed in Rack:
1. Prevention against overloading of branch circuit
When this product is installed in a rack and is
supplied power from an outlet on the rack, please
make sure that the rack does not overload the supply
circuit.
2. Providing protective earth
When this product is installed in a rack and is
supplied power from an outlet on the rack, please
confirm that the outlet is provided with a suitable
protective earth connection.
3. Internal air ambient temperature of the rack
When this product is installed in a rack, please make
sure that the internal air ambient temperature of the
rack is within the specified limit of this product.
4. Prevention against achieving hazardous
condition due to uneven mechanical loading
When this product is installed in a rack, please make
sure that the rack does not achieve hazardous
condition due to uneven mechanical loading.
5. Install the equipment while taking the operating
temperature of the equipment into consideration
For the operating temperature of the equipment, refer
to the specifications of the Operation Manual.
6. When performing the installation, keep the
following space away from walls in order to
obtain proper exhaust and radiation of heat.
Rear: 10 cm (4 inches) or more
Right, Left: 4 cm (1.6 inches) or more
For safety, do not connect the connector for peripheral
device wiring that might have excessive voltage to the
following port(s).
: DATA connector
: CTRL connector
Follow the instructions for the above port(s).


1
MVE-8000A
Table of Contents
Manual Structure
Purpose of this manual .............................................................................................. 2
Related manuals......................................................................................................... 2
Contents ..................................................................................................................... 2
Trademark.................................................................................................................. 2
1. Installation
1-1. Operating Environment ...............................................................................1-1
1-2. Power Supply ..............................................................................................1-1
1-2-1. Power Specifications ..................................................................1-1
1-2-2. Recommended Power Cord........................................................1-2
1-3. Installation Space (External dimensions)....................................................1-3
1-4. Installing the Options ..................................................................................1-4
1-4-1. Installing the Plug-in Boards......................................................1-4
1-4-2. Installing the Connector Board ..................................................1-6
1-4-3. Installing the HK-PSU02 ...........................................................1-7
1-5. Rack Mounting............................................................................................1-9
1-6. Matching Connectors and Cables..............................................................1-11
1-7. Input/Output Signals of Connectors..........................................................1-12
1-8. Checks on Completion of Installation.......................................................1-13
1-8-1. On-board Switches Setting and LED Functions ......................1-13
1-9. System Connection....................................................................................1-22
2. Service Overview
2-1. Troubleshooting ..........................................................................................2-1
2-2. Periodic Inspection and Maintenance .........................................................2-2
2-2-1. Cleaning .....................................................................................2-2
2-3. About the Data Backup Capacitor...............................................................2-2

2MVE-8000A
Purpose of this manual This manual is the installation manual of DME Processor Pack MVE-8000A-C and
their optional boards and units.
This manual is intended for use by trained system and service engineers, and
describes the information on installing the MVE-8000A-C system.
Related manuals The following manuals are prepared for MVE-8000A-C and their optional boards
and units.
..
..
.Operation Manual (Supplied with MVE-8000A-C)
This manual describes the application and operation of MVE-8000A-C system.
..
..
.Maintenance Manual (Available on request)
This manual describes the detailed service information.
If this manual is required, please contact your local Sony Sales Office/Service
Center.
Contents This manual is organized by following sections.
Section 1 Installation
This section describes the operating environment, power supply, installation space,
installation of optional boards and units, rack mounting, connectors, input and
output signals of connectors, checking upon completion of installation, and system
configuration.
Section 2 Service Overview
This section describes the troubleshooting and periodic inspection and maintenance.
Trademark Registered trademark used in this manual is follows.
.Ethernet is a registered trademark of Xerox Corporation.
Manual Structure

1-1
MVE-8000A
Section 1
Installation
1-1. Operating Environment
Operating guaranteed temperature : +5 dC to +40 dC
Performance guaranteed temperature : +10 dC to +35 dC
Operating humidity : 10 % to 90 %
(relative humidity)
Storage temperature : _20 dC to +60 dC
Mass (when all options are installed) : Approx. 16.5 kg
Prohibited locations for installation
.Areas where the unit will be exposed do direct sunlight
or any other strong lights.
.Dusty areas
.Areas subject to vibration.
.Areas with strong electric or magnetic fields.
.Areas near heat sources.
.Areas subject to electrical noise.
.Areas subject where is subjected to static electricity.
Ventilation
The inside of the MVE-8000A-C is cooled by a fan (both
sides).
The power supply can be damaged if the exhaust vent
(both sides) and air intake (front panel) are blocked or the
fan is stopped.
Therefore, leave a blank space of more than 10 cm in the
front and both sides of the MVE-8000A-C.
1-2. Power Supply
1-2-1. Power Specifications
A switching regulator is used for the power supply of this
unit. The voltage within the range of 100 V to 240 V can
be used without changing the supply voltage.
Power requirements : AC 100 to 240 V
Power frequency : 50/60 Hz
Current consumption (when all options are installed) :
2.8 to 1.2 A
m
.As the inrush current at turn-on is a maximum 14 A (at
100 V)/66 A (at 240 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source braker will operate or the unit will
abnormally operate.
.The MVE-8000A contains the single power supply unit
as the standard configuration. A maximum of two power
supply units may be installed. When starting up the
MVE-8000A, be sure to turn on the power of one or
more power supply units.

1-2 MVE-8000A
For customers in the all European countries
1Power cord, 250 V 10 A (2.4 m) : !1-782-929-12
1
AC inlet
1-2-2. Recommended Power Cord
This unit does not come with a power cord.
To get a power cord, please contact your local Sony Sales
Office/Service Center.
w
.Use the approved Power Cord (3-core mains lead)/
Appliance Connector/Plug with earthing-contacts that
conforms to the safety regulations of each country if
applicable.
.Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
w
.Never use an injured power cord.
.Plugging the power cord in the AC inlet, push as far as it
will go.
For customers in the U.S.A. and Canada
1Power cord, 125 V 10 A (2.4 m) : !1-557-377-11
AC inlet
1

1-3
MVE-8000A
482
375
440
520
35
380
26Ø
61
87.517.5
105
7
MVE-8000A
MULTI FORMAT DME PROCESSOR
1-3. Installation Space (External dimensions)
Unit : mm

1-4 MVE-8000A
Screws
(with drop-safe)
Front door assembly
Screws
(with drop-safe)
1-4. Installing the Options
The MVE-8000A-C is shipped from the factory with the
necessary option (refer to the following table) already
installed in the MVE-8000A, in accordance with the
specified system configuration.
MVE-8000A-C options
Model name Board configuration
Plug-in board Connector board
MKE-8020A _CN-2153 board
MVS Interface Board
MKE-8040A DVP-30A board
Advanced Effects Board
HK-PSU02 __
Power Supply Unit
1-4-1. Installing the Plug-in Boards
c
Be sure to turn off the POWER switch and unplug the
power cord from the wall outlet before starting the installa-
tion work.
If the installation work is started with the POWER switch
left on, it may cause electrical shock or damage of printed
circuit boards.
Installation procedure
1. Turn off the main power of the MVE-8000A and
disconnect the AC power cord from the wall outlet.
2. Loosen the four screws (with drop-safe) and remove
the front door assembly in the direction of the arrow.
3. Remove the four screws (B3 x5), and remove the
“plug-in board loose-proof assembly”.
B3 x5
B3 x5
Plug-in board
loose-proof assembly
This manual suits for next models
4
Table of contents