14
HCD-RV7/RV8 SECTION 4
TEST MODE
[GC TEST MODE]
•This mode is used to check the fluorescent indicator tube, LED,
model, destination software version, volume, key and VACS
level.
Procedure:
1. Pressthreebuttons x, [ENTER], and[DISC 2] simultaneously.
2. LEDs and fluorescent indicator tube are all turned on.
3. When you want to enter the software version display mode,
press [DISC 1]. The model and destination are displayed.
4. Each time [DISC 1] is pressed, the display changes starting
from MC version, GC version, CD version, CDDM version,
CDMA version, CDMB version, BDA version, BDB version,
STversion,TA version,TM versionandTCversionin this order,
and returns to the MC version display.
5. When [DISC 3] is pressed while the version numbers are being
displayed except model and destination, year, month and day of
the software creation appear. When [DISC 3] is pressed again, the
display returns to the software version display. When [DISC 1] is
pressed while year, month and day of the software creation are
beingdisplayed,theyear,monthanddayofcreation ofthesoftware
versions are displayed in the same order of version display.
6. Press [DISC 2] button, and the key check mode is activated.
7. In the key check mode, the fluorescent indicator tube displays
“K0V0”. Each time a button is pressed, “K” value increases.
However, once a button is pressed, it is no longer taken into
account.
“V” value increases like 1, 2, 3 ... if rotating [VOLUME] knob
in “+” direction, or it decreases like 0, 9, 8 ... if rotating in
“–” direction.
8. Also when [DISC 3] is pressed after lighting of all LEDs and
fluorescent indicator tubes, value ofVACS level appears.
9. To release this mode, press three buttons in the same manner as
step 1, or disconnect the power cord.
[MC TEST MODE]
•This mode is used to check operations of the respective sections
of Amplifier, Tuner, and Tape.
Procedure:
* To enter MC Test Mode
1. Press three buttons of x, [ENTER] and [DISC 3] simultaneously.
2. The messages MUSIC, MOVIE, GAME and P FILE flash on
the fluorescent indicator tube.
The input FUNCTION is changed to VIDEO.
* Check of Amplifier
1. When vbutton is pressed, GEQ increases to its maximum and
a message “GEQ MAX” appears.
2. When Vbutton is pressed, GEQ decreases to its minimum and
a message “GEQ MIN” appears.
3. When bor Bbutton is pressed, GEQ is set to flat and a
message “GEQ FLAT” appears.
4. When the [VOLUME] knob is turned clockwise even slightly,
the sound volume increases to its maximum and a message
“VOLUME MAX” appears for two seconds, then the display
returns to the original display.
5. When the [VOLUME] knob is turned counter-clockwise even
slightly, the sound volume decreases to its minimum and a
message “VOLUME MIN” appears for two seconds, then the
display returns to the original display.
* Check of clock frequency
1. To check the frequency of clock used to run the time in the unit,
the clock output is available at IC501 pin el (CLOCK-OUT)
on the MAIN board only during MC test mode.
2. The frequency is 32.768 kHz or so.
* Tape function
1. When a tape is inserted in tape deck B and recording is started,
the input source function selects VIDEO automatically.
When [CD SYNC HI-DUB] button is pressed during recording
in function, ALC is turned on.
2. When xbutton is pressed to stop recording, the tape deck B is
selectedandtape isrewound,tapeisrewoundusing –mbutton,
tape is stops at around the record-starting position and playback
of the recordedportion of the tape isstarted. If the [REC PAUSE/
START] buttonis pressed forapauseandpressed again toresume
recording, when tape deck B is rewound, tape deck B will be
rewound until the position where the pause is applied.
3. When [CD SYNC HI-DUB] button is pressed during playback
oftapedeckB,eithernormalspeedorhighspeedcan be selected
by this button.
* AMS Test Mode
1. Select the function “TAPE A” or “TAPE B”.
2. Select the loop and relay by pressing the [DIRECTION] button.
Insert a test tapeAMS-110A orAMS-120 to selected tape deck.
3. Press the [SPECTRUM] button to enter theAMS test mode.
4. After a tape is rewound first, the FF AMS is checked, and the
mechanism is shut off after detecting the AMS signal twice.
5. Then the REW AMS is checked and the mechanism is shut off
after detecting the AMS signal twice.
6. When the check is complete, a message of either OK or NG
appears.
* To release MC Test mode.
1. To release this mode, press the ?/1button.
2. The cold reset is enforced at the same time.
[COLD RESET]
•The cold reset clears all data including preset data stored in the
RAM to initial conditions. Execute this mode when returning
the set to the customer.
Procedure:
1. Press three buttons x, [ENTER], and ?/1simultaneously.
2. The fluorescent indicator tube becomes blank instantaneously,
and the set is reset.
[VACS ON/OFF MODE]
•This mode is used to switch ON and OFF the VACS (Variable
Attenuation Control System).
Procedure:
1. Press ?/1button to turn the set ON.
2. Pressthe[ENTER] and [GAME MIXING] buttons simultaneously.
The message “VACS OFF” or “VACS ON” appears.
[TUNER STEP CHANGE]
(EXCEPT Saudi Arabia model)
•Astep ofAM channels can be changed over between 9 kHz and
10 kHz.
Procedure:
1. Press ?/1button to turn the set ON.
2. Select the function “TUNER”, and press [TUNER/BAND]
button to select the BAND “AM”.
3. Press ?/1button to turn the set OFF.
4. Press [ENTER] and ?/1buttons simultaneously, and the
display of fluorescent indicator tube changes to “AM 9k STEP”
or “AM 10k STEP”, and thus the channel step is changed over.
w
w
w
.
x
i
a
o
y
u
1
6
3
.
c
o
m
Q
Q
3
7
6
3
1
5
1
5
0
9
9
2
8
9
4
2
9
8
T
E
L
1
3
9
4
2
2
9
6
5
1
3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299
http://www.xiaoyu163.com
http://www.xiaoyu163.com