manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Southwire
  6. •
  7. Multimeter
  8. •
  9. Southwire 11050N User manual

Southwire 11050N User manual

Operating Instructions
11050N AUTORANGING MULTIMETER
Instrucciones de uso
Multímetro de Rango Automático 11050N
S
A
F
E
T
Y
R
A
T
E
D
CAT III
600V
UL61010-1
2/15 Rev. 1
11050N manual
Contents Made in China
Product distributed by Southwire Company, LLC
One Southwire Drive, Carrollton, GA 30119
©2014 Southwire Company, LLC. All rights reserved.
southwiretools.com
1-855-SW-T00LS
Toll Free Technical Help
Línea de Ayuda Técnica Gratuita
Scan for warranty informaon
and to access our mobile site.
Escanea para información de garana
y acceso a nuestro sio móvil.
Introduction
WARNINGS
1
The Southwire 11050N autoranging multimeter measures AC/DC
voltage and current, resistance, capacitance, frequency, duty
cycle, and temperature. It also tests diodes, continuity, and
non-contact AC voltage. This meter is fully tested and calibrated
and, with proper use, will provide many years of reliable service.
• Read, understand and follow the Safety Rules and Operating
Instructions in this manual before using this meter.
• The meter’s safety features may not protect the user if not
used in accordance to the manufacturer’s instructions.
• Ensure that the test leads are fully seated in the input jacks and
keep fingers away from the metal probe tips when taking
measurements.
• Before changing functions using the rotary function switch,
always disconnect the test leads from the circuit under test.
• Use only UL listed test leads with the proper safety category
rating.
• Comply with all safety codes. Use approved personal
protective equipment when working near live electrical circuits -
particularly with regard to arc-flash potential.
• Use caution on live circuits. Voltages above 30 VAC RMS,
42 V AC peak, or 60 VDC pose a shock hazard.
• Do not use meter or test leads if they appear damaged.
• Do not use the meter if it operates incorrectly. Protection may
be compromised.
• Verify meter’s operation by measuring a known voltage.
• Do not use the meter in wet or damp environments or during
electrical storms.
• Do not use the meter near explosive vapors, dust or gasses.
2
Input Limits
Function Maximum Input
Voltage AC, Voltage DC
Amperage DC, Amperage AC
Frequency, Resistance, Diode
Test, Continuity, Capacitance
Temperature (°F/°C)
600VDC, 600VAC rms
10ADC, 10AAC rms
600VDC, 600VAC
250VDC, 250VAC
250VDC, 250VAC
General Specifications
Insulation:
Overvoltage category
Display
Polarity
Overrange
Low battery indication
Measurement rate
Auto power off
Operating environment
Storage temperature
For inside use, max height
Pollution degree
Battery
Dimensions/Weight
Safety
• Do not operate meter while Low Battery warning is on.
Replace batteries immediately.
• Do not apply voltage or current that exceeds the meter’s
maximum rated input limit.
Class 2, Double insulation.
CAT III 600V
6000 counts LCD display with function indication.
Automatic, (-) negative polarity indication.
“OL” mark indication
The “ ” is displayed when the battery voltage drops
below the operating level..
2 times per second, nominal
Meter automatically shuts down after approx. 30 minutes
of inactivity.
32°F to 104°F (0°C to 40°C) at < 80% relative humidity.
14°F to 140°F (-10°C to 60°C) at < 80% relative humidity.
7000ft (2000m)
2
One 9V battery, NEDA 1604, IEC 6F22.
5.9” x 2.8” x 1.9”/0.56lb (150 x 70 x 48mm/255g)
For indoor use and in accordance with Overvoltage
Category III, Pollution Degree 2.
Conforms to UL 61010-1 v.2
5
Operation
HOLD
The hold function freezes the reading in the display. Press the HOLD button
momentarily to activate or to exit the HOLD function.
DISPLAY BACKLIGHT
Press and hold the HOLD button for >1 second to turn on the display backlight.
The backlight will automatically turn off after 10 seconds. The display can also be
turned off manually by pressing and holding the HOLD button for >1 second.
MAX/MIN
Note: When using the MAX/MIN function in the Autoranging mode, the
meter will “lock” onto the range that is shown on the LCD display when
MAX/MIN is activated. If a MAX/MIN reading exceeds that range, an “OL”
indicator will be displayed. Select the desired range BEFORE entering the
MAX/MIN mode.
1. Press the MAX/MIN button to activate the MAX/MIN recording mode. The
"MAX" indicator will appear on the LCD display. The meter will display and
hold the maximum reading and will update only when a new “max” occurs.
2. Press the MAX/MIN button again and the "MIN" indicator will appear on
the LCD display. The meter will display and hold the minimum reading and
will update only when a new “min” occurs.
3. To exit MAX/MIN mode press and hold the MAX/MIN button for 2 seconds.
AUTORANGING/MANUAL RANGE SELECTION
When the meter is first turned on, it automatically goes into Autoranging. This
automatically selects the best range for the measurements being made and is
generally the best mode for most measurements. For measurement situations
requiring that a range be manually selected, perform the following:
1. Press the RANGE button. The “AUTO” display indicator will turn off.
2. Press the RANGE button to step through the available ranges until you select
the range you want.
3. To exit the Manual Ranging mode and return to Autoranging, press and hold
the RANGE button for 2 seconds.
Note: The Range button does not operate in Capacitance,
Frequency or Duty Cycle functions.
Note: MAX/MIN does not work on Capacitance,
Frequency or Duty Cycle functions.
6
Operation
Symbols Used
on LCD Display
VVolts
AAmps
AC Alternating current
DC Direct current
- Minus sign
ΩOhms
Continuity
Diode test
FFarads (capacitance)
Hz Hertz (frequency)
% Percent (duty cycle)
ºF Degrees Fahrenheit
ºC Degrees Centigrade
AUTO Autoranging
MAX Maximum
MIN Minimum
HOLD Display hold
Battery status
n nano (10-9)
µ micro (10-6)
mmilli (10-3)
kkilo (103)
Mmega (106)
OL Overload
11050N

Other Southwire Multimeter manuals

Southwire 12070T User manual

Southwire

Southwire 12070T User manual

Southwire 16030A User manual

Southwire

Southwire 16030A User manual

Southwire 10020N User manual

Southwire

Southwire 10020N User manual

Southwire 14070T User manual

Southwire

Southwire 14070T User manual

Southwire 13050S User manual

Southwire

Southwire 13050S User manual

Southwire 11060S User manual

Southwire

Southwire 11060S User manual

Southwire 10040n User manual

Southwire

Southwire 10040n User manual

Southwire 32886963360 User manual

Southwire

Southwire 32886963360 User manual

Southwire 13090T User manual

Southwire

Southwire 13090T User manual

Southwire 10040n User manual

Southwire

Southwire 10040n User manual

Southwire 15190TMaintenancePRO User manual

Southwire

Southwire 15190TMaintenancePRO User manual

Southwire 13070T User manual

Southwire

Southwire 13070T User manual

Southwire 16020N User manual

Southwire

Southwire 16020N User manual

Southwire 10030S User manual

Southwire

Southwire 10030S User manual

Popular Multimeter manuals by other brands

Amprobe AM-500 user manual

Amprobe

Amprobe AM-500 user manual

Sealey MM20.V2 instructions

Sealey

Sealey MM20.V2 instructions

Fluke 8062A instruction manual

Fluke

Fluke 8062A instruction manual

Elenco Electronics M-1006K Assembly and instruction manual

Elenco Electronics

Elenco Electronics M-1006K Assembly and instruction manual

Brymen BM161 user manual

Brymen

Brymen BM161 user manual

Draper DMM6B instructions

Draper

Draper DMM6B instructions

Amprobe AM-510 user manual

Amprobe

Amprobe AM-510 user manual

Matco Tools MD79 user manual

Matco Tools

Matco Tools MD79 user manual

GB GDT-311 owner's manual

GB

GB GDT-311 owner's manual

PowerSmiths International Cyberhawk-200M Installation Bulletin

PowerSmiths International

PowerSmiths International Cyberhawk-200M Installation Bulletin

Brymen TBM161 user manual

Brymen

Brymen TBM161 user manual

Pro's Kit MT-1708 user manual

Pro's Kit

Pro's Kit MT-1708 user manual

Proportion-Air PA470-D Use guide

Proportion-Air

Proportion-Air PA470-D Use guide

Unit UT232 operating manual

Unit

Unit UT232 operating manual

Pro's Kit MT-1217 user manual

Pro's Kit

Pro's Kit MT-1217 user manual

Axio MET AX-105 Operation manual

Axio MET

Axio MET AX-105 Operation manual

B+K precision 114B instruction manual

B+K precision

B+K precision 114B instruction manual

PLUS+QUIP EQP-102 Instructions for use

PLUS+QUIP

PLUS+QUIP EQP-102 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.