QUICK CARD - USER GUIDE FOR THE
DIGITAL 2000 SERIES SPA CONTROLLERS
DUAL SPEED VERSION
Dealer Stamp:
Digi2000Prelim-V2,DS NRC
Please read these instructions carefully
Miscellaneous:
The switch normally beeps every time a button is pushed. These
can be switched off by holding down the Up button and
simultneously pushing the Light button. To switch on again repeat
the above.
The Display normally always returns to the pool temperature. If
you want the display to stay on Time, then pushing the display
button until time is shown and pressing the Down button will lock
the display in this mode. The temp display can be restored at any
time by pushing the Display button.
Heating Indicator: & Load Shedding
This indicator shows when the pool is being heated. It
will turn on and off automatically inAuto and Manual
modes when heating is required.
Load Shedding
( keeping power within design limits ) is an arrangement
predefined at manufacture which, dependent on system and
components used, will switch either the heating element or
accessories on and off to keep within the Controllers power
limits.
Manufactured By:
Spa-Quip Ltd
Cnr Rothwell Ave & Albany Hwy
North Harbour Industrial Park
Auckland, New Zealand
Ph (649) 415 8622, Fax (649) 415 8621
Email: ampac@ihug.co.nz
Australian Distribution and Service:
Spa-Quip (Australia) Pty Ltd
Unit 2A, 4 Hudson Ave
Castle Hill NSW 2154
Ph (612) 9634 5600, Fax (612) 9634 5900
Email: [email protected]
Warning:
If the supply cord is damaged, it shall be
replaced by the manufacturer or its
service agent or similarly qualified person
in order to avoid hazard.
Important:
Before using check that the Spa Pool has been connected to a
suitable weather protected outlet socket and Double Pole
Isolating Switch with suitable ratings as specified on the name
plate of the control box. Do not run this appliance on an
extension lead.
12: LCD Display
2 & 4: Up Down Buttons
3: Set Button
5: Icons
6: Display Button
7: Light Button
8: Pump 2 Button
9: Air Button
10: Mimic Panel
11: Pump 1 Button
The Backlit Liquid Crystal Display can display 5 different
quantities:
A/ The currently sensed pool temperature.
B/ The target Pool temperature
C/ The Time of day
D/ The Sleep start time
E/ The Sleep finish time
In addition the LCD can also show diagnostic fault codes.
These 2 Buttons are used to adjust the Controller Settings as
shown on the LCD Display, after pushing the Set button.
To make any changes to the stored settings select the setting
required using the Display button. The Icon and display will
change to indicate your choice. Press the Set button and the
display will flash the current value. Adjust to the required value
by pressing the Up/Down buttons. If you change your mind,
pressing the Display button will cancel any changes. To keep
changes press the Set button again. The display will always
revert to the water temperature reading after a short time. By
following the above procedure the desired pool temperature can be
set, the Time of Day and the Sleep start and finish times. The time
of day and sleep times will need to be set the first time the
controller is powered up or if it has been turned off for a long period.
If the Sleep start = finish time the Sleep mode is deactivated.
This Icon is lit by default. When lit the LCD display is
measuring the in pool temperature. For accurate readings it is
advisable to run the pump for several minutes in Manual
mode to mix up the pool water.
When lit the desired pool temperature can be adjusted
typically to 37°C (default) or to that which is comfortable.
This Icon indicates that the Time of Day is being displayed.
Time can be adjusted remembering to set forAM or PM as
indicated on the display. 1
When lit the display shows the time at which the controller
will start its Sleep Mode. This is a very handy feature and is
used to silence the Spa Pool during your hours of sleep.
Typically settings are between 12pm & 7am. The Spa can be
used within the Sleep hours without having to change any
times by pressing the Pump 1 Button so that the controller is
in manual mode.
This Icon indicates the Wake up time from Sleep Mode. It is
normal for the Spa to run for a long period after sleep to
recover temperature lost over night. The time should be set
approx. 1 hour before a Spa is desired.
This Indicator is lit when the controller is asleep. Manual
operation will over ride any Sleep settings if the Spa is
required during the preset hours.
This button cycles through the above Icons and LCD displays
allowing viewing or adjustment of the controller’s main settings.
This button controls the Pool Light.Agreen LED indicates when the
light is on.
This button controls the Booster pump. Agreen LED indicates
when the pump is on.
TheAir switch has three modes. Successive pushes select High
speed (red LED), Medium speed (orange LED) and blower
Ramping up and down in speed (green LED).
Options = 1 speed, 2 speed, 3 speed or 2 speed and ramping
Note:
There is an automatic timeout of the blower, booster pump and
light. All three will automatically switch off together 30 minutes after
the last push of their respective buttons.
The colours corresponding to the LED
colours displayed on theAir switch
and Pump 1 can be identified and
interpreted as to their operating mode.
Pushes of this switch selects the main operating modes of the Spa
System.
1/ Auto Mode (red LED) is the default start up mode where the
pump, heating and filtration are automatically controlled.
2/ Manual Mode (orange LED) where the user can control the
main circulation pump even when the system is asleep. The
heating will turn on/off automatically as required. This mode has 2
speeds. The first position is slow speed with the LED flashing and
the second is high speed with the LED constant.
3/ Stand-by Mode (green LED) where the user can turn all Pump 1
functions off for absolute quiet. This mode reverts to auto mode
after a preset time.
Note:
The Manual and Stand-by Modes will automatically revert to Auto
after a factory set time. If additional filtration time for example is
required then pushing the button for Manual mode will give an
additional filtration period and allows it to time out by itself back to
Auto. There is a time delay of a few seconds between the pump
switching on and the heater turning on, and between the heater
switching off and the pump switching off.

Other Spa-Quip Controllers manuals

Spa-Quip Intuitive Series User manual

Spa-Quip

Spa-Quip Intuitive Series User manual

Spa-Quip SPA Power 2000 User manual

Spa-Quip

Spa-Quip SPA Power 2000 User manual

Spa-Quip SP601 Supplement

Spa-Quip

Spa-Quip SP601 Supplement

Spa-Quip SPA Power 1000 Series User manual

Spa-Quip

Spa-Quip SPA Power 1000 Series User manual

Spa-Quip SP400P User manual

Spa-Quip

Spa-Quip SP400P User manual

Spa-Quip SP601-15 User manual

Spa-Quip

Spa-Quip SP601-15 User manual

Popular Controllers manuals by other brands

Vaillant sensoCOMFORT VRC 720f Operating and installation instructions

Vaillant

Vaillant sensoCOMFORT VRC 720f Operating and installation instructions

AUMA SAEx 07.2 Operation manual

AUMA

AUMA SAEx 07.2 Operation manual

maxon motor EPOS2 24/2 Hardware reference

maxon motor

maxon motor EPOS2 24/2 Hardware reference

Syntec S08-SVD22B1-010 instructions

Syntec

Syntec S08-SVD22B1-010 instructions

Chziri ZJR1 Series user manual

Chziri

Chziri ZJR1 Series user manual

Eurotech Helios Platform Hardware reference manual

Eurotech

Eurotech Helios Platform Hardware reference manual

Siemens AEROGYR RWI65.02 manual

Siemens

Siemens AEROGYR RWI65.02 manual

ABB ISL-A 24 instruction manual

ABB

ABB ISL-A 24 instruction manual

Nemtek SOL-REG140 user manual

Nemtek

Nemtek SOL-REG140 user manual

WEG SSW7000 user manual

WEG

WEG SSW7000 user manual

Templari HCC manual

Templari

Templari HCC manual

Siemens Simatic S7-1500R manual

Siemens

Siemens Simatic S7-1500R manual

Siemens SINUMERIK 828D Turning Commissioning manual

Siemens

Siemens SINUMERIK 828D Turning Commissioning manual

Chargery BMS16T Series manual

Chargery

Chargery BMS16T Series manual

4O3A Station Genius v2 user manual

4O3A

4O3A Station Genius v2 user manual

Alcor AU6981 Series Technical reference manual

Alcor

Alcor AU6981 Series Technical reference manual

Mitsubishi AL2 Series Programming manual

Mitsubishi

Mitsubishi AL2 Series Programming manual

Mitsubishi Electric melsec q01ucpu user manual

Mitsubishi Electric

Mitsubishi Electric melsec q01ucpu user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.