Speck pumps BaduJet super-sport II Installation and operating instructions

Rev. 03/17
Page 2
Page 19
EN Operation & Service Manual
ES Manual de Servicio y Funcionamiento
BADU®JET super-sport II
Counter Swimming Unit
Sistema de Nado Contra Corriente

Safety
Safety is emphasized throughout the user manual. These are safety alert symbols (CAUTION, WARNING, and
DANGER). They alert the user of potential personal injury hazards. Obey all safety messages to avoid possible injury or
death or damage to equipment.
2999999320A - Rev. 0317 SW OO.0.OO
Technical Support:
Address: Speck Pumps
8125 Bayberry Road
Jacksonville, FL. 32256
USA
Hours: (Monday - Friday) 8:00 am to 5:00 pm EST
Toll Free: 800-223-8538
Phone: 904-739-2626
Fax: 904-737-5261
Website: www.usa.speck-pumps.com
Manufactured by Speck Pumps, Jacksonville Florida USA, © 2017 All Rights Reserved.
This document is subject to change without notice.
Date of Installation:
Installed by:
Serial Number:
For Service Call:

Table of Contents
Complies with UL 1563
CSA C22.2 No. 218.1-M89
Swimming Pool Equipment
Listing #E212148
VGB 2008
ANSI/APSP-16 LISTED 31B4
Badu®Jet super-sport II Certifications
1 Important Safety Instructions 4
SwimJet Combination Fitting Manufacturers Warnings. . 4
General Safety Instructions. . . . . . . . . . . . . . 5
2 General Description 6
3 Operation 7
Controls Overview . . . . . . . . . . . . . . . . . . 7
Basic Operations . . . . . . . . . . . . . . . . . . 7
Getting Started . . . . . . . . . . . . . . . . . . . 7
4 Service and Maintenance 8
Priming the Pump . . . . . . . . . . . . . . . . . . 8
Testing GFCI . . . . . . . . . . . . . . . . . . . . 8
Nozzle Adjustment . . . . . . . . . . . . . . . . . 9
Winterizing . . . . . . . . . . . . . . . . . . . . . 10
5 Frequently Asked Questions 10
Frequently Asked Questions . . . . . . . . . . . . . 11
Trouble Shooting . . . . . . . . . . . . . . . . . . 11
6 Product Specification 14
Replacement Parts and Exploded View . . . . . . . . 14
7 Limited Warranty 16

4
WARNING: Before Installing this product, read and follow all warning notices and instructions which are included.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call
(800) 223-8538 or visit www.usa.speck-pumps.com for additional copies of these instructions.
1 Important Safety Instructions
Swim Jet Combination Fitting - Manufacturers Warnings
MUST BE INSTALLED by an experienced and qualified pool industry professional ONLY.
Attention Installer: This manual contains important information about installation, operation, and safe use of
this product. This information should be given to the owner and/or operator of this equipment. Most Federal, State
and Local codes regulate the construction, installation and operation of pools and spas. It is important to comply
with these codes, many of which regulate the installation and use of this product.
1. DO NOT locate this fitting in seating areas or on the back rests for such seating areas.
2. This fitting should be mounted in the vertical pool wall only per manufacturer’s instructions.
3. All fittings and fasteners should be examined for damage or tampering before each use.
4. Any missing, broken, or cracked fittings must be replaced before using this product. Only genuine Speck
replacement parts may be used.
5. Acceptable fittings/pipe sizes are listed on page 9 of the installation manual. No other sizes are permitted.
6. Never exceed the maximum flow rate stated on this product.
7. The anti-entrapment cover must be in place when using this product. DO NOT use this product if the cover is
missing, broke or loose.
8. The anti-entrapment cover (part# 93.1) should be replaced within 10 years from installation date.
9. Installation requires a Phillips screw driver. All screws should be hand tight only. DO NOT use electrical or air
drills.
10. Consult your physician before exercising with the BaduJet super-sport or using the massage hose.
11. DO NOT permit children to use this product unless they are closely supervised at all times.
12. DO NOT remove any safety alert labels such as DANGER, WARNING, or CAUTION. Keep safety alert labels in
good condition and replace missing or damaged labels.
13. Stay alert, watch what you are doing and use common sense. DO NOT use unit if you are tired and/or
exhausted. DO NOT use unit while under the influence of drugs, alcohol, or any medications.
14. CAUTION: DO NOT increase pump size; this will increase the flow rate through the system and exceed the
maximum flow rate stated on this product.
IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY PRESENT A RISK OF HAIR OR BODY ENTRAPMENT
AND DROWNING. Install this equipment in accordance with the instructions provided.

5
Swim Jet Combination Fitting - Manufacturers Warnings - continued
As the manufacturer, Speck Pumps - Pool Products, Inc., hereby certifies that their Swim Jet Combination Fitting
meets or exceed the requirements of the Virginia Graeme Baker Pool & Spa Safety Act, VGB 2008 and ANSI/APSP
16 standards and safety regulations as set forth by the Consumer Products Safety Commission.
“Read, and then keep these instructions for future reference”
F
General Safety Instructions
The following guidelines provide information to minimize the risk of injury to users of pools, spas, and hot tubs.
WARNING: TO REDUCE THE RISK OF ENTRAPMENT HAZARD
Pool and spa pumps produce high levels of suction, which can pose extreme danger if a person comes in close
proximity to an open pool or spa drain or if a drain cover is loose, cracked, broken or missing. Pool and spa pumps
move large volumes of water, which can pose extreme danger if a person’s hair comes in close proximity to a
drain that is not the proper size for the pump or pumps.
If not an approved single, unblockable outlet, a minimum of two functioning suction outlets per pump must be
installed. Suction outlets in the same plane (i.e. floor or wall) must be installed a minimum of three (3) feet (1
meter) apart, as measured from center point to center point. Dual suction fittings shall not be located on seating
areas or on the backrest for such seating areas. If any suction outlets are located closer they shall be located on
two dierent planes (i.e. one on the bottom and one on the vertical wall, or one each on two separate vertical
walls).
WARNING: Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other
material can result in an increased potential for suction entrapment.
If not a single, unblockable outlet, in the event of one suction outlet being completely blocked, the remaining
suction outlets serving the system shall have a flow rating capable of the full flow of the pump(s) or the specific
suction system. If in doubt about the rating and/or head loss curve of your system, consult a qualified pool or
spa professional and/or your respective equipment manufacturer(s). Also, double check with your local building/
health authorities regarding single vs. multiple drain installations, etc.
Regularly inspect all drain covers for cracks, damage and advanced weathering. If a drain cover becomes loose,
cracked, damaged, broken or is missing, close the pool or spa immediately, post a notice and keep the pool or spa
closed until an appropriate VGB 2008 certified drain cover is properly installed.
WATER VELOCITY AND FLOW RATES
The maximum water velocity through drain covers is limited by some local regulations, for example some state
health departments limit the velocity through public pool drain covers to 1.5 feet per second. This velocity limit
is lower than the flow rating provided by the ANSI/APSP 16 certification; therefore local limit applies and must
be followed. Never exceed the flow rating listed on the cover even if local code does not provide a velocity limit.
For additional information on proper installation refer to The Association of Pool & Spa Professionals ANSI/APSP-
7 Standard and the US Consumer Product Safety Commission Guidelines for Entrapment Hazard.

6
VGB Compliance - VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT
The Virginia Graeme Baker Pool and Spa Safety Act raises certain new requirements on owners and operators of
swimming pools and spas.
Pools or spas constructed on or after December 19, 2008, shall utilize:
Pools and spas constructed prior to December 19, 2008, with a single submerged suction outlet shall use a
suction outlet cover that meets ANSI/APSP 16-2011 and either:
For more information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product
Safety Commission at (301) 504-7908 or visit www.cpsc.gov.
General Safety Instructions - continued
Pool pump must be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable local codes
and ordinances. Improper installation will create an electric hazard which could result in
death or serious injury to pool users, installers, or others due to electrical shock, and may
also cause damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing
the pump. Failure to do so could result in death or serious injury to serviceman, pool
users, or others due to electric shock.
No submerged suction outlets, a gravity drainage system with ANSI/APSP compliant cover(s), one or more
unblockable outlets; or
A multiple main drain system without isolation capability with suction outlet covers that meet ANSI/APSP
16-2011 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:
(A)
(B)
A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured
Safety Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa,
Hot Tub, and Wading Pool Suction Systems and/or ASTM F2387 Standard Specification for
Manufactured Safety Vacuum Release Systems (SVRS) for Swimming Pools, Spas and Hot Tubs
or
A properly designed and tested suction-limiting vent system or
An automatic pump shut-o system.
(i)
(ii)
(iii)
A multiple main drain system without isolation capability, or a single (VGB 2008 compliant) unblockable
suction outlet, or
A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
A properly designed and tested suction-limiting vent system, or
An automatic pump shut-o system, or
Disabled submerged outlets, or
Suction outlets shall be reconfigured into return inlets.
(A)
(B)
(C)
(D)
(E)
(F)
WARNING: Risk of Electrical Shock or Electrocution
2 General Description
The BaduJet super-sport II from Speck Pumps has been designed to be installed during the construction of your pool to create
a water treadmill for anyone wanting a therapeutic and eective exercise. The BaduJet super-sport II can be installed in any
type of pool, large or small, from gunite to vinyl liner. The self-contained, flush-mounted unit is a jet-propulsion system that
pumps water into the pool creating a current in excess of 5,700 gallons per minute from a recessed jet housing. Topping o
the experience is the pulsating massage hose which can be attached to the jet nozzles for easy and convenient massage
treatments for joints and muscles.

7
3 Operation
A
Controls Overview
Plastic Rectangular Cover
Water Volume Control Knob: This knob
adjusts the amount of water flow through
the jet nozzles.
Air Regulator Knob: This adjusts the
amount of air bubbles in the water flow.
System (ON/OFF) Button: Turns the
system ON/OFF.
Light (ON/OFF) Button: Turns the low
voltage LED light ON/OFF.
Adjustable Jet Nozzles: Allows the user to
angle the nozzles in any direction.
A.
B.
C.
D.
E.
F.
B
D EC
F
Figure 1 - BaduJet super-sport (Front View)
Basic Operation
WARNING: DO NOT use or operate the BaduJet super-sport if the anti-entrapment cover is missing, broken, or loose.
WARNING: To reduce the risk of injury, DO NOT permit children to use this product unless they are closely supervised at all
times.
CAUTION: Consult your physician before attempting any strenuous exercise. This product may not be challenging or satisfying
for all levels of exercise.
Turning the System ON & OFF:
Position yourself to the side of the swimjet system. Use your free hand to press the System ON/OFF button.
Turning the Light ON & OFF:
Position yourself to the side of the swimjet system. Use your free hand to press the Light ON/OFF button.
Adjusting the Water Flow:
Holding onto the side of the pool, you can easily adjust the water flow coming from the jets. To do this simple turn the
water volume control knob clockwise to reduce the flow. To increase the flow turn the knob counter clock wise.
Adjusting the air flow (or bubbles):
The air regulator knob permits a controlled mixture of air into the water flow and creates a unique, invigorating, bubble
eect. It will also add additional resistance to swim against. To do this simply turn the knob clockwise to reduce the air.
n
n
n
n
Getting Started
To start swimming, jogging or running it is suggested that the two nozzles are pointed slightly inward and slightly upward so
that the water “breaks” approximately 4 ft. in front of the BaduJet super-sport (See for Nozzle Adjustment).
Start swimming with only minimal force in arms and legs until you feel yourself drifting backwards, then add force and swim
upstream until a proper balance is found between force and endurance. Keep in mind that this unit is designed for a balanced
workout. Find a pace that you can keep up for at least 20 minutes. Out pacing is always possible. The idea is to continue
exercising for an extended period of time.

8
NOTE: Under certain conditions it is possible that
the current “drifts o” to the left or the right from
the middle due to water bouncing o the back wall.
In the event that it interferes with your swimming
action, turn the unit OFF for a few minutes and
restart.
Getting Started - continued
Before starting the pump for the first time (or after losing prime),
remove the red filler plug. Fill the pump body with water (approx.
2 gallons) until the water is level with the suction inlet. Replace
the red filler plug, hand tighten, making sure the o-ring is not
damaged. Due to the large amount of air that can be trapped in
the vertical portion of the suction line above the water level,
initial priming time may be longer than with regular pool filtration
pumps. It may take up to ten (10) minutes. This will not damage
the mechanical seal. If prime is not achieved in ten (10) minutes,
stop the pump, re-fill the pump body and restart.
Figure 2 - The Speck Model 21-80/33 GS (US Motor)
The BaduStream system comes with a 4 HP self-priming pump (Speck Model 21-80/33 GS) to specifically work with the
swimjet system. The Model 21-80/33 GS self-priming pump has the ability to remove air from the plumbing lines when
installed above the water level (up to 4 feet). During the initial startup, the pump must be filled with water. You should never
run the pump dry for extended periods of time.
Fill Plug
Priming Pump
4 Service and Maintenance
WARNING: Before each use, the GFCI located on the side of the control box must be tested.
Control Box - Testing the GFCI
1. Press the RESET button on the GFCI. The GREEN “power” LED
should be ON.
2. Press the TEST button: GREEN LED should turn OFF. RED LED
should start blinking. Circuit breaker should trip to OFF position.
3. If sensing module LEDs DO NOT change or circuit breaker
DOES NOT trip, DO NOT USE THIS DEVICE. Consult a qualified
electrician for assistance.
4. Press RESET button: RED LED should turn OFF and GREEN LED
should turn ON.
5. MANUALLY RESET circuit breaker to ON position to restore
circuit power. Figure 3 - Control Box

Nozzle Adjustments
When setting the nozzles for basic swimming, it is recommended that you set the nozzles in such a way that each nozzle
intersects 4 feet away while breaking the surface at the same time. To help set the nozzles in position for best performance,
please follow these instructions:
1. Parts required:
Quantity 2 - 4’ x 1.5” PVC Pipe
Quantity 2 - 1.5” MPT x 1.5”/1.25” Hose Adapter
Quantity 2 - Female Adapter 1.5” Slip x 1.5” FPT
2. Turn OFF the jet pump(s).
3. Insert each jet adjustment tool into jet nozzle.
4. Bring the ends of the adjustment tools together so they are touching in between the jet housings. Then raise the tools
together so the ends touch the water surface. (See Figure 4)
5. Remove jet adjustment tool.
PVC Pipe 1.5" x 4'
PVC Coupling 1.5"
Hose Adapter 1.5"
Perspective View
Water Level
~12”
Side View
9
Figure 4
BaduJet Nozzle Adjustment

Gasket
Winter Cover
M8 Washer (4x)
M8 x 30mm Screw (4x)
10
Winterizing
Figure 5
Winter Cover Kit
In areas subject to freezing water temperatures, you should protect your equipment. We recommend you purchase a winter
cover kit part #2326000010K. This kit includes one (1) winter plate, one (1) gasket, four (4) M8 washers, and four (4) M8 x
30mm screws. (See Figure 5) Please contact your local pool professional for installation.
I can over swim the system, is there something I can do to help me from swimming through the system? Slow your
pace down until you found the stroke that will prevent you from out swimming the system. Depending on the size of the pool
you could drift back and swim into the stream and try to find the “sweet spot” which is about 4’ from the jets.
How can I use the system for my kids? Our BADU swim jets systems will add fun and enjoyment for all ages. The kids can
boogie broad against the current. Kids can play in front of the current. To do this turn the air up and just the adjust nozzles
upwards to create a choppy white water eect.
What is a self-priming pump?
A self-priming pump has the ability to remove air from the plumbing lines when installed above water level (up to 4 feet).
During the initial startup, the pump must be filled with water. You should never run the pump dry.
Why must a self-priming pump first be filled with water?
A self-priming pump must have a sucient amount of water in the pump housing. Only then can air be removed from the
suction line. It is necessary to fill your pump up to the suction connection with water. If you do not fill the pump with water
you may damage the mechanical seal in the pump.
What are the maintenance requirements for the pump?
The Speck Model 21-80/33 GS pumps are generally maintenance free. From time to time you should carry out a visual
inspection. Check to see if pump is leaking, a few drops is normal. Remove any debris around the pump.
Does the LED light come in dierent colors?
Yes. The LED light comes in blue or a multi-color option.
How many amps does the pump operate at?
4.0 HP: Maximum 21.0 - 19.4 Amps @ 208-230 V
5 Frequently Asked Questions
Frequently Asked Questions

11
What size breaker do I need?
You must use a 40 amp breaker for the 4 HP pump to avoid nuisance tripping.
Should the swimjet system be tied into the filter system?
No. The swim jet system and the filter system should not be plumbed together as they each provide very specific functions.
Can I use it with automated controls?
Yes. It comes with the ability to tie into automated control systems or other switching devices. A licensed electrician would
need to wire in this feature.
How should I store my pump for the winter season?
It’s simple: drain pump and store it in a warm and dry place.
Why is the swimjet pushing to the side?
Refer to nozzle adjustment section. Also, Speck Pumps oers a BADU Swim Mirror that will help you stay in the swim lane.
You will be able to see yourself as you swim.
My pool is the recommended size but my feet keep hitting the wall, what can I do to fix that?
Adjust the flow so the system is not pushing you back. Another option is the BADU Swim mirror. This will help keep you in
the swim lane.
Frequently Asked Questions
Trouble Shooting
PROBLEM POSSIBLE CAUSES SOLUTION
1. Pump will not prime. a. Suction air leak.
b. No water in pump.
c. Closed valves or blocked lines.
d. Low voltage to motor.
Make sure the red filler plug and o-ring are clean and
properly positioned. Tighten red filler plug. Tighten all
pipes and fittings on suction side of the pump. Be sure
water in the pool is high enough to flow through the
jet housing.
Make sure pump housing is full of water.
Open all valves in system. Open pump and check for
clogging of impeller.
Check voltage at motor. If low, pump will not come up
to speed.
2. Motor does not turn. a. No power to motor.
b. Pump jammed.
Check that all power switches are on. Be sure fuse or
circuit breaker is properly set. Check motor wiring at
terminals.
With power o, turn shaft. It should spin freely. If not,
disassemble and repair.
3. Low flow. a. No water in pump.
b. Closed valves or blocked lines.
c. Low voltage to motor
See problem 1.
4. Noisy operation of
motor.
a. Bad bearings. Check for noise when shaft is turned by hand. Motor
will be very hot in bearing area when running. Replace
bearing.

12
Trouble Shooting - continued
PROBLEM POSSIBLE CAUSES SOLUTION
5. Motor runs hot. These motors will run hot to the touch, however, this is normal. They are designed that
way. Thermal overload protector will function to turn them o if there is an overload or high
temperature problem. Excessive heat can be caused by:
a. Low voltage.
b. Installed in direct sun.
c. Poor ventilation.
Increase size of electrical wire. Be sure motor is
operating on correct voltage.
Shield motor from sun’s rays.
DO NOT block motor ventilation openings.
6. Noisy operation of
pump.
a. Air leak in suction line.
b. Restricted suction line due
to blockage or under size pipe.
Indicated by high vacuum reading
at pump suction.
c. Foreign matter (gravel, metal,
etc.) in pump impeller.
d. Cavitation.
Repair leak. Check suction pipe, red filler plug, and
o-ring (See Problem 1).
Remove blockage or increase suction pipe size. Are all
suction valves fully open?
Disassemble pump and remove foreign matter from
impeller.
Improve suction conditions. (Reduce suction line
length, reduce number of fittings, increase pipe size.)
7. Motor overload
protection “kicks out”.
a. Motor is not connected properly.
b. Low voltage due to under size
wire or low incoming voltage.
c. Wrong size heaters in protective
device.
d. Overload due to binding in pump
or wrong size impeller.
Check wiring diagram on motor.
Check with volt meter. Increase size of supply wire.
Report low supply voltage to power company. Voltage
at motor must be within 10% of motor nameplate
voltage.
Heaters should be one size larger than full load amps
shown on motor nameplate.
Indicated by high amperage readings on motor, binding
shaft. Disassemble unit and correct.
8. The LED light is not
working?
a. Moisture in air tubing or bad air
button.
b. Control Box.
Remove air tubing from air switch at control box. Con-
nect a short piece of air tubing to the LED air switch.
Blow into tube and check if LED turns ON/OFF.
Contact certified electrician to diagnose control box
components.
9. The volume control
knob keeps spinning?
a. Broken Spindle. Contact your pool service company or call 800-223-
8538.
10. My ON/OFF air
button is not working
properly?
a. Control Box.
b. Air tubing.
Check GFCI. If green LED does not stay ON, contact a
certified electrician to diagnose control box compo-
nents.
Check air tubing connection on the control box. Check
that the tubing is not bent or pinched. Tubing may
need to be replaced.
11. The system will not
turn OFF?
a. Control Box Components. Press TEST button on the control box GFCI to turn o
system. Contact a certified electrician to diagnose con-
trol box components.

13
Trouble Shooting - continued
PROBLEM POSSIBLE CAUSES SOLUTION
12. I have the volume
control knob turned com-
pletely up but the flow is
weak?
a. Debris in pump casing/impeller.
b. Improper swim jet assembly.
Contact your local pool service company to check in-
side pump casing for any debris.
The internals may need to be removed for inspection
of the spindle.
13. My plastic cover is
cracked.
Contact your pool service company or call 800-223-
8538.
14. The massage hose is
stuck against the jet
Apply both hands on the outer side of the lip of the
locking ring, slightly pulling back until this snaps back.
Should be able to remove

52
30
1
26 27
28
102.1
61
93
94
95
47
62
9
4
110
112
37
38.1
38.2
111
21.1
48
23
102
64
66 66
67
63
109
108
58
56
54
59
60
102.1
22
21 107
6
4
101
25
20
113
114
115
116
117
118
96
31
32
33
98
14
6 Product Specification

Exploded View
15
PART
NUMBER
DRAWING
NUMBER
QTY
REQUIRED
DESCRIPTION
2326000002A
2301001007
2326000408
2301001008
2326000031
2321000409
2326000006
5879812996
5882501619
2326000020
2301000026
2326000021
2301000028
2301000030
5805510880
5809021080
5879340800
2326000014
2321000401
2321000404
2300202060
2302001046
5879860830
2302002954
2302002056
2302002057
2319800817
5879006023
5879006023
2326000013
2326000004
2303002964
2302002065
2302002067
2302005236
5871250800
5879860820
5879860880
2302005237
2991000140
5030000105
2326000003
2326000402
3932541201
2607101019
2326000037
2326000005
2321000022
5879006023
2920141230
2326000032
2326000034
2301001030
5862432021
5862432531
2920280729
2326000036
2326000038
2326000010K
2300003000
2300003006
2300022000
1
4
6
9
20
21
21.1
22
23
25
26
27
28
30
31
32
33
37
38.1
38.2
47
48
52
54
56
58
59
60
61
62
63
64
66
67
93
94
95
95.1
96
98
101
102
102.1
107
108
109
110
111
112
113
114
115
116
117
118
NOT SHOWN
109.1
109.2
NOT SHOWN
NOT SHOWN
NOT SHOWN
NOT SHOWN
1
3 FT
1
2
1
1
1
3
1
1
1
1
1
1
4
4
4
2
1
1
2
2
12
2
2
2
2
6
10
1
1
1
2
1
1
4
4
4
4
2
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
JET HOUSING
HOSE - AIR REGULATOR 8 x 3mm (PRICE PER FOOT)
HOSE (3X) WITH Y- HOSE BARB
CLAMP - HOSE, AIR REGULATOR 14/9 SS A4
STRAIN RELIEF - LIGHT CABLE, 3/4” NPT
AIR REGULATOR COMPLETE
VOLUME CONTROL KNOB
SCREW - AIR REGULATOR, 2.9 x 9.5
STRAIN RELIEF - LIGHT CABLE, M16 x 1.5
ROUND SEALING CORD
GASKET WITH KNOBS - JET HOUSING
GASKET - CLAMPING RING
RING - CLAMPING
GUNITE COVER
STUD - GUNITE COVER M8 x 80mm
WASHER - GUNITE COVER M8
NUT - STUD - GUNITE COVER M8 A2
O-RING PNEUMATIC BUTTONS 24 x 3mm
PNEUMATIC BUTTON COMPLETE - PUMP
PNEUMATIC BUTTON COMPLETE - LIGHTS
AIR TUBING - LIGHT/PUMP 4 x 1.5mm (PRICE PER 10M)
CLAMP - HOSE, PNEUMATIC BUTTON 6.8 - 8mm
SCREW - CLAMPING RING, POZIDRIV/PAN M8 x 30mm A4
NOZZLE - 40mm
SEAT - NOZZLE
SPACER - NOZZLE 6.2mm
NOZZLE FLANGE
TAPPING SCREW - BALL NOZZLE FLANGE, 6 x 22mm A4
TAPPING SCREW - NOZZLE HOUSING, 6 x 22mm A4
O-RING - NOZZLE HOUSING 257 x 3mm
VOLUME CONTROL CYLINDER
VOLUME CONTROL SPINDLE (COMPLETE)
WASHER - VOLUME CONTROL SPINDLE, 23 x 16.2 x1.5mm
RETAINER - SHAFT, VOLUME CONTROL SPINDLE
COVER - RECTANGULAR
WASHER - RECTANGULAR COVER 8.4mm A4
BOLT - RECTANGULAR COVER, PHILLIPS M8 x 20mm
BOLT - RECTANGULAR COVER, PHILLIPS M8 x 80mm
PLUG - RECTANGULAR COVER
SCREW - COUNTERSUNK PHILLIPS M8 x 30mm
VALVE - CHECK 1/2”
HOUSING - NOZZLE
HOUSING - NOZZLE COMPLETE
O-RING - LIGHT 48 x 2mm
O-RING - LIGHT 49 x 3.5mm
LIGHT LED 12V AC - WHITE, 10M
LIGHT COVER
AIR REGULATOR KNOB
TAPPING SCREW - LIGHT COVER, 6 x 22mm A4
O-RING - CHECK VALVE, 19 X 3mm
O-RING - STRAIN RELIEF
ADAPTOR - STRAIN RELIEF, FEMALE, PVC 3/4”
ADAPTOR - CHECK VALVE, MALE, PVC 1/2“
CONNECTOR - AIR REGULATION LINE M20 x 1/2”
CONNECTOR - CONDUIT M25 x 3/4”
CONTROL BOX BJC-7-GFCI+CP SSII
LIGHT LED 12V AC - MULTICOLOR, 10M
LIGHT LED 12V AC - BLUE, 10M
WINTER COVER KIT
MASSAGE HOSE 5 FT. WITH PULSATOR
MASSAGE HOSE 15 FT. WITH PULSATOR
CAP - NOZZLE, CLOSE OFF
OPTIONAL PARTS

16
7 Limited Warranty
Speck Pumps-Pool Products, Inc. grants solely to the original consumer purchaser (“Buyer”) of the Badu®SwimJet System(s)
the following personal, non-transferable and limited warranty on the following terms and conditions (the “Limited Warranty”):
the Badu SwimJet System(s) is warranted to be free of material defects in materials or workmanship under normal use for a
period of one (1) year beginning on the date of the Buyer’s purchase of the Badu SwimJet System(s) (the “Limited Warranty
Period”). Not withstanding any provisions herein to the contrary, the warranties and obligations hereunder shall not in any
event extend for more than two (2) years beyond the date of shipment of the Badu SwimJet System(s) from the factory (the
“Limited Warranty Period”). The Limited Warranty is subject to each of the following additional terms and conditions:
1. IN THE EVENT OF ANY BREACH OF THE LIMITED WARRANTY, SPECK PUMPS-POOL PRODUCTS, INC.’S ENTIRE
OBLIGATION AND LIABILITY TO BUYER, AND BUYER’S SOLE AND EXCLUSIVE REMEDY SHALL BE AS FOLLOWS: Speck
Pumps-Pool Products, Inc. will, at its option, either repair or replace the Badu SwimJet System(s) or refund to Buyer the
purchase price actually paid by Buyer for the Badu SwimJet System(s) subject to the Limited Warranty. Speck Pumps-Pool
Products, Inc. shall have no obligations under the Limited Warranty unless Buyer delivers timely written notice to Speck
Pumps-Pool Products, Inc. of the Limited Warranty claim within the Limited Warranty Period and returns the Badu SwimJet
System(s) to Speck Pumps-Pool Products, Inc. if requested. To the fullest extent permitted by law, Speck Pumps-Pool Products,
Inc. expressly disclaims any liability for, and the Limited Warranty does not include or cover, any labor, costs or other expenses
in connection with the removal, transportation, shipment, insurance, replacement, repair, or installation of repaired or replaced
parts or for any other costs or expenses or damages to property or things including, but not limited to, those arising in
connection with the use of, or inability to use, the Badu SwimJet System(s).
2. To the fullest extent permitted by law, the Limited Warranty will be void and of no force or eect and Speck Pumps-Pool
Products, Inc. will have no liability, responsibilities or obligations to Buyer or with respect to the Badu SwimJet System(s) in
the event of the occurrence of any one or more of the following:
(a)
(b)
(c)
(d)
(e)
Any damage to the Badu SwimJet System(s) caused by Buyer, any third party, ground movement, other natural
forces, acts of God or any other sources or causes not arising from a breach of the Limited Warranty, excluding
ordinary wear and tear;
Any replacement, modification, alteration or repair of any parts or components of the Badu SwimJet System(s) by
anyone other than Speck Pumps-Pool Products, Inc.;
Any abuse, misuse, accident, tampering with, improper installation or modification of the Badu SwimJet System(s) or
any other actions, inactions or failures to act that violate the terms and conditions of this Limited Warranty;
Buyer’s failure or inability to present an invoice, bill, receipt or other documentation clearly evidencing that the Badu
SwimJet System(s) was installed and maintained in strict compliance with this Limited Warranty and that the claim
was timely submitted within the Limited Warranty Period; and/or
Buyer’s failure to comply with the conditions and contingencies set forth in paragraph 3 below.
3. The Limited Warranty is expressly conditioned and contingent upon Buyer’s strict compliance with each of the following:
(a)
(b)
Installation of the Badu SwimJet System(s) by an experienced and qualified pool industry professional and a licensed
electrician who is licensed within the jurisdiction in which the Badu SwimJet System(s) is installed and will be used;
and
Buyer’s operation and maintenance of the Badu SwimJet System(s) in strict accordance with Speck Pumps-Pool
Products, Inc.’s printed operator/maintenance manuals delivered with the Badu SwimJet System(s).
4. DISCLAIMER: THE LIMITED WARRANTY IS THE ONLY WARRANTY MADE AND IS IN LIEU OF ALL OTHER WARRANTIES,
AND ANY AND ALL IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY, THE IMPLIED WARRANTY AGAINST
INFRINGEMENT, AND THE IMPLIED WARRANTY OR CONDITION OF FITNESS FOR A PARTICULAR PURPOSE ARE
EXPRESSLY LIMITED IN THEIR SCOPE AND DURATION TO THE ONE YEAR TERM OF THE LIMITED WARRANTY SET
FORTH HEREIN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE
ABOVE LIMITATION MAY NOT APPLY TO THE BUYER.

17
Limited Warranty - continued
5. TO THE FULLEST EXTENT PERMITTED BY LAW, IN NO EVENT SHALL SPECK PUMPS-POOL PRODUCTS, INC. OR ITS
OFFICERS, DIRECTORS, EMPLOYEES, SHAREHOLDERS, AGENTS, OR REPRESENTATIVES BE LIABLE FOR ANY SPECIAL,
INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR LOSS, INCLUDING TIME, MONEY, GOODWILL,
AND LOST PROFITS IN ANY WAY WHICH MAY ARISE HEREUNDER OR FROM THE USE OF OR INABILITY TO USE THE
BADU SWIMJET SYSTEM(S) OR THE PERFORMANCE OR NONPERFORMANCE OF ANY OBLIGATION UNDER THIS
LIMITED WARRANTY. THIS PARAGRAPH, THE WARRANTY DISCLAIMERS IN PARAGRAPH 4 ABOVE, AND THE SOLE AND
EXCLUSIVE REMEDY SET FORTH IN PARAGRAPH 1 ABOVE SHALL APPLY EVEN IF SPECK PUMPS-POOL PRODUCTS,
INC. HAS BEEN NOTIFIED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH DAMAGES OCCURRING, WHETHER SUCH
LIABILITY IS BASED ON CONTRACT, TORT, NEGLIGENCE, STRICT LIABILITY, PRODUCTS LIABILITY OR OTHERWISE,
AND EVEN IF ANY REMEDY STATED HEREIN FAILS OF ITS ESSENTIAL PURPOSE. SOME STATES DO NOT ALLOW THE
EXCLUSION OR LIMITATION OF SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR
LOSS, SO THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY.
6. This Limited Warranty gives the Buyer specific legal rights, and the Buyer may also have other rights, which vary from
state to state.
7. A return merchandise authorization (“RMA”) must be obtained from Speck Pumps-Pool Products, Inc. before returning any
product. Products returned without an RMA will be refused and returned, unopened, to the Buyer. All returned products are
to be sent freight prepaid and insured for Buyer’s protection to the manufacturer at 8125 Bayberry Road, Jacksonville, Florida
32256 USA. Under no condition will products be accepted after the expiration of the Limited Warranty Period. Speck Pumps-
Pool Products, Inc. shall not bear any costs or risks incurred by Buyer in shipping a defective Badu SwimJet System(s) to Speck
Pumps-Pool Products, Inc. or in shipping a repaired or replaced Badu SwimJet System(s) to Buyer.


Rev. 03/17
ES Manual de Servicio y Funcionamiento
BADU®JET super-sport II
Sistema de Nado Contra Corriente

Soporte Técnico:
Fabricado por Speck Pumps, Jacksonville Florida USA, ©2017 Todos los derechos reservados.
Este documento está sujeto a cambios sin aviso.
Fecha de Instalación:
Instalado por:
Número de Serie:
Para Llamada de Servicio:
Dirección: Speck Pumps
8125 Bayberry Road
Jacksonville, FL. 32256
USA
Horario: (Lunes - Viernes) 8:00 am a 5:00 pm EST
Teléfono Gratuito:
(en los Estados Unidos) 800-223-8538
Teléfono: 904-739-2626
Fax: 904-737-5261
Sitio Web: www.usa.speck-pumps.com
Email: [email protected]om
2999999320A - Rev. 0317 SW OO.0.OO
Table of contents
Languages:
Other Speck pumps Lighting Equipment manuals

Speck pumps
Speck pumps Badu Stream II Service manual

Speck pumps
Speck pumps Badu Stream II User manual

Speck pumps
Speck pumps Badu Stream II User manual

Speck pumps
Speck pumps Badu Stream II Service manual

Speck pumps
Speck pumps BADU JET User manual

Speck pumps
Speck pumps BADU JET Service manual

Speck pumps
Speck pumps Badu Stream II Service manual
Popular Lighting Equipment manuals by other brands

Flash professional
Flash professional P7200004 user manual

Chauvet
Chauvet LED Techno Strobe ST-3000LED Appendix

SICK
SICK C 4000 Series operating instructions

Pani
Pani BP 6 GT user manual

Philips
Philips CoreLine WT120C LED18S/840 PSU L600 installation instructions

ELMEKO
ELMEKO AL 900 Assembly and operating instructions