Request To Exit Function
The request to exit input (M-P1 on unit terminal) timer
is linked to user in rank 000.
Timer
•Every field must be a two digit entry.
•The timer value range for illuminating the
keypad is from 01 to 99 seconds.
•Valid output timer values are from
01 – 99 seconds.
•00 selects the latch (toggle) mode
Default Values
The Speco Technologies architectural backlit keypad
is designed for easy installation. The following defaults
have been factory programmed.
•No pre-configured user code
•Code length – 4 digits
•Illumination duration – 10 seconds
•Time delay allowed between key press
10 seconds
•Return to stand-by from configuration mode:
120 seconds (2 minutes)
•Factory Set Master Code - 1234
•Hardware (jumper) reset is provided by the
master code.
•Output timer values – 5 seconds
•Sounder - ON
•Key press for output #2 - Inactive
•Key press for output #3 – Inactive
•Doorbell on output #2 – Inactive (if avail.)
If additional functions are needed or default changes
are desired, refer to Programming Options chart.
Key Press Active On Output #2 and #3
If ‘key press is active’ on output #2 & #3 is enabled,
then output #2 or #3 cannot be included in the choices
offered by function 52.
Doorbell Active On Output #2
If ‘Doorbell active on output # 2’ is enabled, output # 2
cannot be included in the choices offered by function
52. The value in ‘Output 2 timer value’ (from 01 to 99
seconds) is the duration of relay # 2 activation when
the door bell button is momentarily pressed. If the
door bell activation must follow the key press action,
then ‘Output 2 timer value’ should be 00.
Audible Sound Definitions
1 Short Beep Unit is just powered up, key press or
data is valid in configuration mode.
1 Long Beep Relay activation following a valid
user code or data recorded in
configuration mode.
2 Short Beeps Getting In or Out of configuration
mode
4 Short Beeps Data error.
Default Master Code
When the keypad is in operation, put the jumper
(2 PIN header on Main PC board) in place and one
beep will sound. The master code will return to the
.
factory setting - 1234 – and the code length will
return to 4 digits. Remove the jumper to return
to normal operation.
Selection of Outputs by User Code
It is possible to select one or two outputs for
each user code. This is done by entering a two
digit value in the first field of function 52.
Some examples are listed below:
•Type ‘12’ if you want the user code to
activate outputs 1 and 2
•Type ‘23’ if you want the user code to
activate outputs 2 and 3
•Type ‘13’ if you want the user code to
activate outputs 1 and 3
•Type ‘02’ if you want the user code to
activate only output 2
•Type ‘01’ if you want the user code to
activate only output 1
Keypad Self Test Operation
The self test confirms that the unit is operating
orrectly.
•Connect the wires from a 12V or 24V
AC or DC power source (leave power
off) to the power input terminals.
•Install the jumper
•Turn the power ON from the power
source, one long beep will sound.
•Type: 7890#123456*. Self test begins
•All keys illuminate with a short beep
•Memory is reset
•Default values are written
•Key illumination stops
•‘Output 1 default timer value’ is read
•One short beep sounds
•Codes are written in rank 000 and rank
129
•All keys illuminate with a short beep
•‘Output 2 and Output 3 timer value’ is
written, then read back
•1.5 second activation of the 3 outputs
•Illumination stops/one short beep
sounds
•The two programmer codes are read
back
•All keys illuminate
•Memory is reset and two beeps sound
•Press ‘request to exit’ (make a short
between EXIT SW inputs on terminal)
•Key illumination stops
•Bell key pressing is allowed for next 5
seconds
•One short beep sounds
•Default values are written
•Key lights flash
•Remove the jumper
•Keypad resets
•One beep should sound
This should be a good guide for those who would like
to test the unit before installing it. If a problem is
encountered, the unit will beep continuously until the
jumper is removed and the unit is reset.