Speco Technologies weatherproof mullion backlit keypad (SG-WM200) is designed to meet
most residential, commercial and industrial single door access control requirements. It is a two
piece unit that is fully sealed for all environments. The electronics reside in the protected area.
Key Features:
•Mounts on the narrow mullion of glass
and aluminum doors
•Indoor/Outdoor surface mount
applications
•12 backlit keys
•Sounder
•Weather resistant
•130 users
•Input trigger for request to exit
•3 independent relay outputs (5A/250V AC)
•Adjustable time relay of up to 99 seconds
for each relay output or latched
•Rank/Code program administration
•Each output is assignable by code
•Codes can range from 3 to 6 digits
•Unit shuts down for 20 seconds after
entering 3 incorrect codes
•Master code can shut down all others as a
temporary lock-out
•Audible function confirmation
•12/24 Volt – AC/DC operation
Codes
The Speco Technologies architectural backlit keypad
allows up to 130 user codes, of 3 to 6 digits in length,
to be programmed.
•The master code and user codes must be the
same length.
•Available ranks are from 001-129 and ranks
are all 3 digit values.
•0-9 are valid digits for user codes, but ‘ * ’ or
‘ # ’ is not allowed to be used in a user or
master code.
•By default, a valid user code activates output
1 if not defined.
•Hardware (jumper) reset is provided by the
master code.
•Can assign up to two outputs per code.
•Each user code must be different. Trying to
enter the same code twice will generate an
error.
•The Master code is strictly reserved for
configuration and cannot be used to operate
an output.
•All parameters are saved on EEPROM.
•A valid user code needs to be followed by
the *key.
Programming
All programming is done from the front of the
keypad. Sounder guidance helps to make
programming easy and authorized users can
change codes in seconds.
Key Press Audible Feedback
The sounder can be deactivated by
programming for user code entries (function 60).
Memory
EEPROM non-volatile memory means your
programming is safe. The codes and
instructions will still be there anytime power is
removed.
Keypad Lockout
•If needed, every programmed user’s
code can be disabled without deleting
them. This is achieved by using
function 90 ‘Keypad Lockout ON’
•When ‘Keypad Lockout’ is active, any
‘Request To Exit’ devices connected
on the EXIT SW input will still activate
relay one to allow exiting.
•When ‘Keypad Lockout’ is active, the
master code (MC) will only activate
output one. Activation time of output
one is the time configured in rank 000
which is also the time used for
‘Request To Exit’ function.
Instruction Manual
Weatherproof Mullion Backlit Keypad
SG-WM200

Speco Technologies® 0106 SG-WM200
2
Speco Technologies Weatherproof Mullion Backlit Keypad Instruction Manual SG-WM200
Request To Exit Function
The request to exit input (M-P1 on unit terminal) timer
is linked to user in rank 000.
Timer
•Every field must be a two digit entry.
•The timer value range for illuminating the
keypad is from 01 to 99 seconds.
•Valid output timer values are from
01 – 99 seconds.
•00 selects the latch (toggle) mode
Default Values
The Speco Technologies architectural backlit keypad
is designed for easy installation. The following defaults
have been factory programmed.
•No pre-configured user code
•Code length – 4 digits
•Illumination duration – 10 seconds
•Time delay allowed between key press
10 seconds
•Return to stand-by from configuration mode:
120 seconds (2 minutes)
•Factory Set Master Code - 1234
•Hardware (jumper) reset is provided by the
master code.
•Output timer values – 5 seconds
•Sounder - ON
•Key press for output #2 - Inactive
•Key press for output #3 – Inactive
•Doorbell on output #2 – Inactive (if avail.)
If additional functions are needed or default changes
are desired, refer to Programming Options chart.
Key Press Active On Output #2 and #3
If ‘key press is active’ on output #2 & #3 is enabled,
then output #2 or #3 cannot be included in the choices
offered by function 52.
Doorbell Active On Output #2
If ‘Doorbell active on output # 2’ is enabled, output # 2
cannot be included in the choices offered by function
52. The value in ‘Output 2 timer value’ (from 01 to 99
seconds) is the duration of relay # 2 activation when
the door bell button is momentarily pressed. If the
door bell activation must follow the key press action,
then ‘Output 2 timer value’ should be 00.
Audible Sound Definitions
1 Short Beep Unit is just powered up, key press or
data is valid in configuration mode.
1 Long Beep Relay activation following a valid
user code or data recorded in
configuration mode.
2 Short Beeps Getting In or Out of configuration
mode
4 Short Beeps Data error.
Default Master Code
When the keypad is in operation, put the jumper
(2 PIN header on Main PC board) in place and one
beep will sound. The master code will return to the
.
factory setting - 1234 – and the code length will
return to 4 digits. Remove the jumper to return
to normal operation.
Selection of Outputs by User Code
It is possible to select one or two outputs for
each user code. This is done by entering a two
digit value in the first field of function 52.
Some examples are listed below:
•Type ‘12’ if you want the user code to
activate outputs 1 and 2
•Type ‘23’ if you want the user code to
activate outputs 2 and 3
•Type ‘13’ if you want the user code to
activate outputs 1 and 3
•Type ‘02’ if you want the user code to
activate only output 2
•Type ‘01’ if you want the user code to
activate only output 1
Keypad Self Test Operation
The self test confirms that the unit is operating
orrectly.
•Connect the wires from a 12V or 24V
AC or DC power source (leave power
off) to the power input terminals.
•Install the jumper
•Turn the power ON from the power
source, one long beep will sound.
•Type: 7890#123456*. Self test begins
•All keys illuminate with a short beep
•Memory is reset
•Default values are written
•Key illumination stops
•‘Output 1 default timer value’ is read
•One short beep sounds
•Codes are written in rank 000 and rank
129
•All keys illuminate with a short beep
•‘Output 2 and Output 3 timer value’ is
written, then read back
•1.5 second activation of the 3 outputs
•Illumination stops/one short beep
sounds
•The two programmer codes are read
back
•All keys illuminate
•Memory is reset and two beeps sound
•Press ‘request to exit’ (make a short
between EXIT SW inputs on terminal)
•Key illumination stops
•Bell key pressing is allowed for next 5
seconds
•One short beep sounds
•Default values are written
•Key lights flash
•Remove the jumper
•Keypad resets
•One beep should sound
This should be a good guide for those who would like
to test the unit before installing it. If a problem is
encountered, the unit will beep continuously until the
jumper is removed and the unit is reset.

Programming Chart Speco Technologies SG-WM200 Keypad
Key p
r
ess active on output # 3 70 # 1 # *
Type 55 #
Master Code *
Output 2 timer value
From 01 to 99 (seconds) note 1 22 # (time) # *
Output 3 timer value
From 01 to 99
(
seconds
)
note 1
Master Code (MC) modification
Len
g
th must match code len
g
th
Adding or editing a user code
23 # (time) # *
31 # (new MC) # (new MC) # *
32 # (rank) # (code) # (code) # *
Adding or editing a user code with
timer value for output 1 33 # (time) # (ran
k
) # (code) # (code) # *
Disabling a user code
34 # (ran
k
) # *
Unit entire reset
40 # 12345 # 12345 # *
Output activation (2 digits)
selection
p
er user code 52 # (01 or 23 or…) # (rank) # (code) #(code) #*
Buzzer always ON 60 # 1 # *
Buzzer OFF when typing user codes
60 # 0 # *
Symbol ‘*’ cannot be used as a value
Symbol ‘#’ is the enter key in configuration mode
B2
* Exit
2 beeps
Error Return to Main menu
B4
B2
Code length from 3 to 6 digits 30 # (length 3 to 6) # *
Output 1 default timer value
From 01 to 99
(
seconds
)
note 1 21 # (time) # *
Key illumination ON
24 # 0 # *
Key illumination OFF or timed
24 # 1 # *
Key illumination timer value
From 10 to 99
(
seconds
)
25 # (time) # *
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
M A I N M E N U
R E T U R N T O M A I N M E N U
B1
B1
80 # 0 # *
B1
B1
Doorbell inactive
80 # 1 # *
B1
B1
Doorbell active on output # 2
B2
* Exit
2 beeps
Note 1: 00 will select the latch operation mode (output ON until another valid code turns it OFF)
Press (*) to exit configuration mode
Keypad Lockout OFF
90 # 1 # * enable
B1
B1
Keypad Lockout ON (Keypad reading
Master Code only)
90 # 0 # * disable
B1
B1
70 # 0 # *
B1
B1
Key press inactive
B4
B1
2 beeps
B2
B1
4 beeps
1 beep
1 long beep

Speco Technologies® 0106 SG-WM200
3
Speco Technologies Weatherproof Mullion Backlit Keypad Instruction Manual SG-WM200
SG-WM200 Specifications:
Speco Technologies weatherproof mullion backlit keypad (SG-WM200) is designed to meet
most residential, commercial and industrial single door access control requirements. It is a two
piece unit that is fully sealed for all environments. The electronics reside in the protected area.
•Power : AC or DC, from nominal 12V to 24V
•Acceptable voltage variation :
12V DC to 28V DC max.
10V AC to 26V AC max.
•Power Consumption:
-At 12V DC
Less than 100mW in standby
Less than 1.4W max. in operation
- At 24V DC
Less than 360mW in standby
Less than 3.3W max. in operation
- At 12V AC
Less than 255mW in standby
Less than 2.3W max. in operation
- At 24V AC
Less than 1W in standby
Less than 5.7W max. in operation
Operating Temperature: -13° F to +130° F (-25°C to +55°C)
Dimensions: 5-7/8”H x 1-3/8”W x ¾”D
Warranty : 1 Year
Rank & Code
Each user has a rank and code which allows the System Administrator to keep track of the
system without knowing personal codes. Access can be allowed or denied by rank, even if a code
is not known.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/ TV technician for help.
Other Speco Technologies Single Door Access Control Products
SG-100 Stainless Steel Indoor Keypad
SG-WR150 Weatherproof Ruggedized Keypad
SG-W300 Weatherproof Architectural Backlit Keypad
Speco Technologies
200 New Highway
Amityville, NY 11701
800-645-5516
631-957-8700
Fax: 631-957-9142 or 631-957-3880
www.specotech.com
®
070106
SG-WM200 Relay Diagram
Table of contents
Other Speco Keypad manuals