Starway ParKolor 200HD User manual

User ManUal
www.star-way.com version 16022022 V1.02
200hd

Page 2 Page 3
Table of content
Technical Specications ............................................................................ 3
Dimensions ............................................................................................. 3
Regulation and Safety ................................................................................ 4
Photometry.............................................................................................. 5
Installation ............................................................................................... 8
DMX 512 use.......................................................................................... 8
Menu Structure........................................................................................ 9
Display .................................................................................................. 10
Menu.................................................................................................... 10
DMX map.............................................................................................. 13

Page 2 Page 3
TECHNICAL SPECIFICATIONS :
• Led COB RGBW 180W
• Zoom 8 ° - 44.5 ° beam
• Max ux 4365 Lm (Zoom max)
• Protocols: DMX / RDM
• DMX modes: 6HSI/6RGB/7/10/15ch
• Auto / Static / Master-Slave
• BColor System
• White Macros : 10 from 2700 to 10,000 ° K
• DMX Connectors In / Out : 2 x XLR5 IP65
• Power Connectors In / Out : Seetronic IP65
• Removable connector protection cap
• Cooling :
- 1 natural convection mode
- 3 forced ventilation modes
• Dimensions L x P x H: 329.5 x 215 x 370mm
• Weight: 10.3Kg
• Max power: 200W
DIMENSIONS :

Page 4 Page 5
WARNING!
Before carrying out any operations with the unit,
carefully read this instruction manual and keep it with cure
for future reference. It contains important about the installation,
usage and maintenance of the unit.
SAFETY
General InstrUctIon
• The products referred to in this manual conform to the European Community
Directives and are there-fore marked with CE:.
• The unit is supplied with hazardous network voltage (110/230V~). Leave ser-
vicing to skilled personnel only. Never make any modications on the unit not
described in this instruction manual, otherwise you will risk an electric shock.
• Connection must be made to a power supply system tted with efcient earth-
ing (Class I appliance ac-cording to standard EN 60598-1 ). It is, moreover,
recommended to protect the supply lines of the units from indirect contact
and/or shorting to earth by using appropriately sized residual current devices.
• The connection to the main network of electric distribution must be carried out
by a qualied electrical installer. Check that the main frequency and voltage
correspond to those for which the unit is designed as given on the electrical
data label.
• Never use the xture under the following conditions:
- in places subject to vibrations or bumps;
- in places with an ambient temperature of over 45° C.
• Make certain that no inammable liquids, water or metal objects enter the
xture.
• Do not dismantle or modify the xture.
• All work must always be carried out by qualied technical personnel. Contact
the nearest sales point for an inspection or contact the manufacturer directly.
• If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
WarnInGs and InstallatIon precaUtIons
• Never let the power cord come into contact with other cables! Handle the power
cord and all connections with the mains with particular caution!
• Never modify, bend, mechanically strain, put pressure on, pull or heat up the pow-
er cord.
• Never strain the cable. There must always be sufcient cable going to the device.
Otherwise, the cable will be damaged, which can cause serious damage.
• Never remove warning or informative labels from the unit.
• Never use anything to cover the ground contact.
• Never lift the device holding it by the projector-head, as the mechanics may be
damaged
• Do not shake the device. Avoid brute force when installing or operating the device.
• Only operate the device after having checked if the housing is rmly closed and all
screws are tightly fastened.
• Only operate the device after having familiarized with its functions.
• Avoid ames and do not put close to ammable liquids or gases.
• Always allow a free air space of at least 0.8 m around the unit for ventilation.
• Always disconnect power from the mains, when device is not used or before clean-
ing! Only handle the power cord holding it by the plug. Never pull out the plug by
tugging the power cord.

Page 4 Page 5
Photometry
Distance 5 meters , Zoom Minimum
Color Wave lenght Lux
Red 633 nm 965 lux
Green 516 nm 1175 lux
Blue 448 nm 355 lux
White 7650 K 1995 lux
All LEDs 4720 lux
Red LED
Green LED
MeasureMents Made with uspectruM MK305s

Page 6 Page 7
Blue LED
White LED
RGBW

Page 6 Page 7
Angle Mini Angle Maxi
° Beam:6 ,87
° Field: ####
Eclaire ###### 29369 13053 7342 4699 3263 2397 1836 1450 11759 71 8166 95 5995 22 4594 06 3633 25 294
Distance en 12345678 91 01 11 21 31 41 51 61 71 81 92 0
D Be 0,12 0,24 0,36 0,48 0,60 ,720 ,840 ,961 ,081 ,2 1,32 1,44 1,56 1,68 1,81 ,922 ,042 ,162 ,282 ,4
D Fie0 ,220 ,440 ,660 ,881 ,1 1,32 1,54 1,76 1,98 2,22 ,422 ,642 ,863 ,083 ,3 3,52 3,74 3,96 4,18 4,4
00 ,060 ,120 ,180 ,240 ,3 0,36 0,42 0,48 0,54 0,60 ,660 ,720 ,780 ,840 ,9 0,96 1,02 1,08 1,14 1,2
00 ,110 ,220 ,330 ,440 ,550 ,660 ,770 ,880 ,991 ,1 1,21 1,32 1,43 1,54 1,65 1,76 1,87 1,98 2,09 2,2
0- 0,1 -0,1- 0,2 -0,2- 0,3 -0,4- 0,4 -0,5- 0,5- 0,6- 0,7- 0,7 -0,8- 0,8 -0,9- 1- 1 -1,1- 1,1 -1,2
0- 0,1- 0,2- 0,3- 0,4- 0,6- 0,7- 0,8- 0,9- 1- 1,1- 1,2 -1,3- 1,4- 1,5- 1,7- 1,8- 1,9- 2- 2,1- 2,2
-1,5
-1
-0,5
0
0,5
1
1,5
metres 0,22 0,44 0,66 0,88 1,11 ,321 ,541 ,761 ,982 ,2
metres 0,12 0,24 0,36 0,48 0,60 ,720 ,840 ,961 ,081 ,2
Distance metres 12 34 56 78 91 0
Lux 117475 29369 13053 7342 4699 3263 2397 1836 1450 1175
° Field: 12,55
° Beam: 6,87
R
a
d
i
u
s
i
n
m
e
t
e
r
s
Field Angle 12.55°
Beam Angle 6.87°
Ø Beam in meters
in meters
Illuminance (Lux)
-4
-3
-2
-1
0
1
2
3
4
metres 0,58 1,16 1,74 2,32 2,93 ,484 ,064 ,645 ,225 ,8
metres 0,42 0,84 1,26 1,68 2,12 ,522 ,943 ,363 ,784 ,2
metres 0,51 1,52 2,53 3,544 ,5 5
Lux 325758 144 3619 2036 13039 05 6655 09 402 326
° Field : 60,23
° Beam : 45,56
Field Angle :60.23°
Beam Angle : 45.56°
R
a
d
i
u
s
i
n
m
e
t
e
r
sDistance
Illuminance (Lux)
Ø Beam in meters

Page 8 Page 9
Installation
Setup :
The projector can be mounted in any position and at any angle.
When placed, the surface supporting it must be able to withstand at least 10 times the weight of the projector and must
be stable enough not to cause damage to the projector, people or surrounding objects.
When the projector is hung, systematically and obligatorily remember to secure it with a safety chain.
Electrical connection :
Under 230 VAC, 10 ParKolor 200HD can be connected with the IN and Out connectors.
Under 110 VAC, 5 ParKolor 200HD can be connected with the IN and Out connectors.
DMX512 use
The use of a DMX amplier is necessary if you use more than 20 interconnected units or a line longer than 60 m.
The use of a real DMX cable (120 ohms) makes it possible to avoid untimely loss of information. The use of a terminal
plug is strongly recommended. In some cases, the absence of this termination is not a problem. On the other hand, its
presence is very strongly recommended in disturbed spaces (Stage, long line length, TV studio, etc.). Its value is usually
120 Ohms. The cap is a male XLR socket in which is soldered, a resistance of 120 Ohms ¼ of W, between the pins
2 and 3 of the XLRs.
The cap prevents the reection of transmitted information when using long cable lengths.
21
3
12
3
3
5
42
1
2
1
3
4
5
GND
DATA -
DATA +
GND
DATA +
DATA -
NON CONNECTE
NON CONNECTE
12
3
2
1
3
4
5
120 Ω
120 Ω

Page 8 Page 9
MENU STRUCTURE
The values shown in RED are the default values (reloaded after a DFSE)
001 - 512
ADDRESS
6CH - HSI
CH_MODE
DIM4 (1s)
Hold
LOST DMX
Blackout
Display
LCD.Set
Key Lock
Flash
ON / OFF
ON / OFF
°C
/ °F
DIM0 (instant)
Dim Mode
DIM1 (0,25s)
DIM2 (0,50s)
DIM3 (0,75s)
6CH - RGB
7CH - RGBW
10CH - Enh8B
15CH - Enh16b
Status
ON / OFF
Invert ON / OFF
Temp
ON / OFF
Fast Dimmer
Disp. CH
DISP.Set
SLAVE
Auto
FAN.Set
High
Quiet
Silent
Linear
Dim Curve
Square
INV-Square
S-Curve
ON/OFF
D.F.S.E.
ON/OFF
Strobe CH
INFO
Time Inf Current
Total
Last
Password Clear
Temp Inf LED Temp
Err. Inf None/Zoom/Temp
Model Inf PARKOLOR 200HD
Software Vx.xxx
MANUAL
Reset M.
Manual
Green: 000-255
Blue: 000-255
White: 000-255
Dim: 000-255
Str: 000-255
Zoom: 000-255
Red: 000-255
Calibration
Password
Green: 000-255
Blue: 000-255
White: 000-255
Red: 000-255
ADDR
Zoom: 000-255

Page 10 Page 11
DISPLAY
Menu: Scroll main menu or exit active submenu.
Enter: To enter the menu or conrm the active function or value.
Up: To scroll up in the menu or increase the value of the active function.
Down: To scroll down in the menu or decrease the value of the active function.
ParKolor 200 HD unlock password:
UP - DOWN - UP - DOWN - ENTER
ADDRESS :
• Enter the DMX address using the [UP] and [DOWN] keys then validate using the [ENTER] key.
CH MODE :
• Choose the DMX mode (6ch HSI, 6ch RGB, 7ch RGBW, 10ch Enh 8 Bits, 15ch Enh 16 Bits)
using the [UP] and [DOWN] keys then validate using the [ENTER] key.
MENU STATUS
LOST DMX :
• Choose one of these two options when losing DMX signal :
• [Hold] : keeps the last value in case of loss of the DMX signal.
• [BLACKOUT] : Blackout when there is no DMX signal.
LCD.SET :
Enter this sub-menu to determine the behavior of the display
• Entrer the [Display] sub-menu, select [ON] or [OFF] to leave the display on or off.
• Entrer the [KEY LOCK] sub-menu, select [ON] or [OFF] to lock the keys
(password : UP, DOWN, UP, DOWN, ENTER).
• Entrer the [FLASH] sub-menu, select [ON] or [OFF] to enable or disable the display ash function when there is
no DMX signal.
• Entrer the [Invert] sub-menu, select [ON] or [OFF] to reverse the display direction.

Page 10 Page 11
TEMP :
• Choose temperature unit [CELSIUS] or [FAHRENHEIT].
FAST DIMMER
Enter this sub-menu to bypass [DIM Mode] in case of rapid channel change from Dimmer to 0.
• Choose [ON] or [OFF] to change dimmer behavior.
DIM MODE
Enter this sub-menu to set the speed of the Dimmer.
• Choisir [DIM0] for instant dimmer, [DIM1] for a 0,25 second dimmer speed,
[DIM2] for a 0,5 second dimmer speed, [DIM3] for a 0,75 second dimmer speed,
or [DIM4] for a 1 second dimmer speed.
DISP.Set :
Enter this sub-menu to dene the display mode
• [ADDR] to display the DMX adress.
• [Disp.CH] to display the DMX values.
• [Slave] to switch the PARKOLOR 200 HD to slave mode.
FAN.Set :
Enter this sub-menu to dene the cooling mode
• [Auto] fans in automatic mode
• [High] fans in foced operation mode at 100%
• [Quiet] fans in silent mode
• [Silent] fans OFF
DIM CURVE
Enter this sub-menu to dene the Dimmer curve.
• [Linear] - The increase in light intensity is linear as the DMX value increases.
• [Square] - Light intensity control is ner at low levels and coarser at high levels.
• [Inv-Square] - Light intensity control is coarser at low levels and ner at high levels.
• [S-Curve] - Light intensity control is ner at low and high levels and coarser at medium levels.
DFSE :
• Enter this sub-menu to reset the device to factory default.
(Reload the values shown in red in the menu structure)
Linear Curve Square Curve Inv-Square Curve S Curve

Page 12 Page 13
STROBE CH :
Enter this sub-menu to select the behavior of the strobe channel:
• [ON] - LEDs are ON when the strobe channel is at 0.
• [OFF] - LEDs are OFF when the strobe channel is at 0.
INFO
[Time.Info] - Usage Time
• [Current] : Display of usage time (in hours) since last power-on.
• [TotalTime] : Display of usage time (in hours).
• [Last] : Display of the time of use (in hours) since the last time reset.
• [PASSWORD] : To access the usage time reset, you must enter a
PIN code: 050 to reset [Last] value.
[Clear] : [ON] to reset [OFF] to cancel
[Temp.Info] - Temperature display
• [LED temp] : xxx F or C - LED temperature display
[Err.Info] - sensor errors
• [None] : No error
• [Zoom] : Zoom Sensor error
• [Temp] : LED temperature sensor error
[ModelInf] - Displaying the projector model [ParKolor 200 HD]
[Software] - Firmware version display [Vx.xxx]
MANUAL :
[Reset.M] - Enter this sub-menu to reset the Zoom.
[ManCtrl] - Manual control
Allows you to create a luminous state. Adjust the following parameters to create a state.
Validate with [Enter] each parameter.
• [Dimmer] : from 000 to 255 adjust overall Intensity.
• [Strobe] : from 000 to 255 adjust the Strobe.
• [Zoom] : from 000 to 255 adjust the Zoom.
• [Red] : from 000 to 255 adjust the red Intensity.
• [Green] : from 000 to 255 adjust the green Intensity.
• [Blue] : from 000 to 255 adjust the blue Intensity.
• [White] : from 000 to 255 adjust the white Intensity.
[Calibrate]
Sub-menu allowing to recalibrate the various parameters of the ParKolor 200 HD.
To access this menu, you must enter the PIN code to unlock this function.
Pin Code : 050
This gives access to the various parameters.

Page 12 Page 13
RGB (6 Ch)
Channel Value Function
Instant
/
Fade
Default
Value
1000-255 Red F 255
2000-255 Green F 255
3000-255 Blue F 255
4000-255 Zoom from 8° to 44.5° F 128
5000-255 Macro I 0
6
Control
I 80
000-010 Dim Mode (Follow Menu)
Hold value for 3 seconds
011-020 Dim0
021-030 Dim1
031-040 Dim2
041-050 Dim3
051-060 Dim4
61-100 Idle
101-110 Fan Silent
111-120 Fan Quiet
121-130 Fan Auto
131-140 Fan High
141-150 Fast Dimmer OFF
151-160 Fast Dimmer ON
161-200 Idle
201-255 Zoom Reset
DMX MAP

Page 14 Page 15
HSI (6 Ch)
Channel Value Function
Instant
/
Fade
Default
Value
1 000-255 Hue F 255
2 000-255 Saturation F 255
3 000-255 Intensity F 0
4 000-255 Zoom from 8° to 44.5° F 128
5 000-255 Macro I 0
6
Control
I 80
000-010 Dim Mode (Follow Menu)
Hold value for 3 seconds
011-020 Dim0
021-030 Dim1
031-040 Dim2
041-050 Dim3
051-060 Dim4
61-100 Idle
101-110 Fan Silent
111-120 Fan Quiet
121-130 Fan Auto
131-140 Fan High
141-150 Fast Dimmer OFF
151-160 Fast Dimmer ON
161-200 Idle
201-255 Zoom Reset

Page 14 Page 15
RGBW (7 Ch)
Channel Value Function
Instant
/
Fade
Default
Value
1000-255 Dimmer F 0
2
Strobe
I 3/8
000-005 LED OFF (check page 12)
006-010 LED ON (check page 12)
011-090 Strobe from slow to fast
091-170 Random strobe from slow to fast
171-255 Synchronized random strobe on all PARKOLOR 200 HD
From slow to fast
3000-255 Red F 255
4000-255 Green F 255
5000-255 Blue F 255
6000-255 White F 255
7000-255 Zoom from 8° to 44.5° F 128

Page 16 Page 17
MODE ENHANCED 8bits (10 Ch)
Channel Value Function
Instant
/
Fade
Default
Value
1000-255 Dimmer F 0
2
Strobe
I 3/8
000-005 LED OFF (check page 12)
006-010 LED ON (check page 12)
011-090 Strobe from slow to fast
091-170 Random strobe from slow to fast
171-255 Synchronized random strobe on all PARKOLOR 200 HD
From slow to fast
3000-255 Zoom from 8° to 44.5° F 128
4000-255 Red F 255
5000-255 Green F 255
6000-255 Blue F 255
7000-255 White F 255
8000-255 Virtual Color Wheel (see details on page 17) I 0
9
Color Time / Color Speed
F 0000-255
If value of channel 8 between 12 and 250
Fade from 0 to 10 seconds
000-255
If value of channel 8 between 251 and 255
Rotation speed from slow to fast
10
Control
I 80
000-010 Dim Mode (Follow Menu)
Hold value for 3 seconds
011-020 Dim0
021-030 Dim1
031-040 Dim2
041-050 Dim3
051-060 Dim4
61-100 Idle
101-110 Fan Silent
111-120 Fan Quiet
121-130 Fan Auto
131-140 Fan High
141-150 Fast Dimmer OFF
151-160 Fast Dimmer ON
161-200 Idle
201-255 Zoom Reset

Page 16 Page 17
MODE ENHANCED 16bits (15 Ch)
Channel Value Function
Instant
/
Fade
Default
Value
1000-65535 Dimmer F 0
2Dimmer Fine
3
Strobe
I 3/8
000-005 LED OFF (check page 12)
006-010 LED ON (check page 12)
011-090 Strobe from slow to fast
091-170 Random strobe from slow to fast
171-255 Synchronized random strobe on all PARKOLOR 200 HD
From slow to fast
4000-255 Zoom from 8° to 44.5° F 128
5000-65535 Red F 255
6Red Fine
7000-65535 Green F 255
8Green Fine
9000-65535 Blue F 255
10 Blue Fine
11 000-65535 White F 255
12 White Fine
13 000-255 Virtual Color Wheel (see details on page 17) I 0
14
Color Time / Color Speed
F 0000-255
If value of channel 13 between 12 and 250
Fade from 0 to 10 seconds
000-255
If value of channel 13 between 251 and 255
Rotation speed from slow to fast
15
Contrôle
I 80
000-010 Dim Mode (Follow Menu)
Hold value for 3 seconds
011-020 Dim0
021-030 Dim1
031-040 Dim2
041-050 Dim3
051-060 Dim4
61-100 Idle
101-110 Fan Silent
111-120 Fan Quiet
121-130 Fan Auto
131-140 Fan High
141-150 Fast Dimmer OFF
151-160 Fast Dimmer ON
161-200 Idle
201-255 Zoom Reset

Page 18
channel 8 or 13 table
DMX Color
0 RGBW MAX
1 White 10000° K
2 White 8000° K
3 White 6500° K
4 White 5600° K
5 White 5000° K
6 White 4500° K
7 White 4000° K
8 White 3200° K
9 White 3000° K
10 White 2700° K
11 Red
ô
51 Yellow
ô
91 Green
ô
171 Blue
ô
211 Magenta
ô
250 Red
251 Idle
252 Virtual color wheel rotation >>
253
254 Virtual color wheel rotation <<
255

In order to improve the products, technical modications can be made without prior information.
This is the reason why the technical characteristics and the physical appearance of the products can change.
To benet from the latest updates to our products, please log on to: www.star-way.com.
NOTES

STARWAY
22 Rue Edouard Buffard
77144 Montevrain
France
Tél. : +33 (0)820 230 007
Fax : +33 (0)1 46 15 47 16
Other manuals for ParKolor 200HD