Storch Kamine SIC 700 SMART User manual

Gültig seit/Valid from/Valide: 09.10.2019
- User Manual
AUTOMATIC BURNING REGULATOR
SIC 700 SMART
EN

2
Gültig seit/Valid from/Valide: 09.10.2019
TABLE OF CONTENTS
1 BASIC AND TECHNICAL DESCRIPTION..................................................................................... 5
1.1 Basic description of the equipment ................................................................................ 5
1.2 No more overheating with SIC 100 SMART ..................................................................... 5
1.3 General information ...................................................................................................... 5
1.4 Advantages of automatic regulation............................................................................... 6
1.5 Technical description of the equipment.......................................................................... 6
1.5.1 Control unit............................................................................................................ 6
1.5.2 Display unit............................................................................................................ 7
1.5.3 Block diagram ........................................................................................................ 7
1.6 Technical requirements for the mobile app .................................................................... 7
1.6.1 Android.................................................................................................................. 7
1.6.2 iOS......................................................................................................................... 7
1.7 Technical description of the components ....................................................................... 7
1.7.1 Cables.................................................................................................................... 7
1.7.2 Servomotors .......................................................................................................... 8
1.7.3 Door switch............................................................................................................ 8
2 INSTALLATION ...................................................................................................................... 8
2.1 Installation procedure ................................................................................................... 8
2.1.1 Step 1 –Basic installation ....................................................................................... 8
2.1.2 Step 2 –Set up the burning regulator...................................................................... 8
2.1.3 Step 3 –Electrical connections................................................................................ 8
2.1.4 Step 4 –Download and install the mobile app......................................................... 9
2.1.5 Step 5 –Pair the regulator with the mobile app ...................................................... 9
2.2 List of components and Diagram depicting the basic connection of a burning regulator. 10
2.3 Connection diagram Standard connection cable for the servo....................................... 11
2.3.1 STORCH servomotor............................................................................................. 11
2.4 Installation and assembly regulations .......................................................................... 12
2.4.1 Temperature sensor assembly .............................................................................. 12
2.4.2 Door switch assembly........................................................................................... 13
2.4.3 Assembly of the central unit................................................................................. 14
2.4.4 Servomotor assembly........................................................................................... 15
2.4.5 Assembly of LED display ....................................................................................... 16
3 DESCRIPTION OF THE MOBILE APP....................................................................................... 17
3.1 Main screen................................................................................................................. 17
3.2 User settings ............................................................................................................... 19
3.3 Service menu............................................................................................................... 22
4 INDICATIONS AND NOTIFICATIONS...................................................................................... 23
4.1 Mobile app indications and notifications...................................................................... 23
4.1.1 Mobile app indicators........................................................................................... 23
4.1.2 Mobile app notifications –text notifications ......................................................... 23

3
Gültig seit/Valid from/Valide: 09.10.2019
4.2 Display panel indications ............................................................................................. 24
4.3 Control unit acoustic signals......................................................................................... 24
5 OPERATING INSTRUCTIONS................................................................................................. 24
5.1 Starting the stove (burning without SIC 700 SMART)..................................................... 24
5.2 Before putting the stove into operation ....................................................................... 27
5.3 Heating with burn-off control ...................................................................................... 28
5.4 End the heating process............................................................................................... 29
6 SAFETY INSTRUCTIONS........................................................................................................ 30
6.1 How to proceed during a power outage ....................................................................... 30
6.1.1 Manually opening the Air flap............................................................................... 30
7 MAINTENANCE AND CLEANING ........................................................................................... 30
8 GENERAL PROVISIONS......................................................................................................... 30
9 TECHNICAL SPECIFICATIONS ................................................................................................ 31

4
Gültig seit/Valid from/Valide: 09.10.2019
Warning: the service actions listed in this document may only be carried out by persons who have
been trained to assemble STORCH automatic combustion regulators.
In order to operate with 230 V equipment, the servicing person must also have the corresponding
qualifications.
All electrical work for connection and installation must be executed in accordance with relevant valid
national and regional standards and regulations, and in compliance with the provisions of the local
electricity supplier.

5
Gültig seit/Valid from/Valide: 09.10.2019
1BASIC AND TECHNICAL DESCRIPTION
1.1 Basic description of the equipment
Thank you for purchasing our product - the SIC 700 SMART automatic burning regulator for fireplaces
and stoves. When we developed this device, we put our many years of experience in burning
regulators to good use and linked the device to a mobile app using modern communication
technology. We are confident the product will meet your expectations.
This device has attributes that make it stand out in its area and incorporates the latest developments
in the field to significantly improve user experience and add value:
Informs about optimal fuel dosage
Indicates overheating
Displays a history of max. achieved temperatures for the 10 last runs
The combustion process is controlled by learning software that gradually adjusts the
regulation curve in order to optimize combustion
Can select between the following combustion modes: Eco –Smart –Turbo
Can select two types of fuel: wood –wood briquettes
The device is controlled through the mobile app
All of these properties improve the safety and economic aspects of combustion in fireplaces and
stoves.
1.2 No more overheating with SIC 100 SMART
The most noticeable poor effect associated with operating fireplaces or stoves is overheating. Very
often, people add more fuel than needed. This leads to a significant portion of excess energy
escaping through the chimney. Overheating is not economical and significantly reduces the service
life of the heating system, including the chimney. SIC 700 SMART can detect overheating and inform
the user to adjust (reduce) the next fuel dosage.
1.3 General information
The mobile app informs the user about the current status throughout the combustion stage. The app
displays 4 colours (grey, yellow, green, red) representing the current temperature in the furnace.
Aim to adjust the fuel dose so the mobile app or display panel indicates a red colour when the
furnace is at its maximum temperature.
The mobile app also displays the flue gas temperature, position of the EAI (external air intake)
shutter, combustion time and other settings as described in the following sections.
Automatic burning regulation in both stoves and fireplaces optimizes the burning process in the
furnace in order to increase combustion efficiency.
STORCH automatic burning regulation is controlled by a microprocessor control unit that compares
the current burning status with a “combustion process optimization” program. based on this
evaluation, the amount of air entering the furnace is regulated using an electronically controlled EAI
(external air intake).
Automatic burning regulation can be installed in all fireplace and stove furnaces with an external air.

6
Gültig seit/Valid from/Valide: 09.10.2019
1.4 Advantages of automatic regulation
Prolongs the combustion process and extends stoking intervals
Reduces fuel consumption by 30 % or more
Prevents overheating of the heating system
Increases combustion efficiency and the efficiency of the heating system as a whole
Improves heat comfort
Increases heating safety
Extends the service life of the heating system
Controls other external components (depending on the type of regulation)
Indicates the need to stoke
Informs about the efficiency of the heating system
1.5 Technical description of the equipment
1.5.1 Control unit
Input
1x thermal unit type “K” – t1 (up to 100 °C)
Power supply: 24 V/DC
1x switch to start combustion regulation
ostart button
oor mechanical door switch
Output
1x universal servomotor (standard or with return spring)
1x beeper (audio output)

7
Gültig seit/Valid from/Valide: 09.10.2019
1.5.2 Display unit
three-colour LED for indicating temperature in the furnace
1.5.3 Block diagram
- configuration required for automatic combustion regulation
- optional configuration
Note: the SIC 700 SMART has a fully autonomous regulator. This means the control unit does
not need to be connected to a display panel or mobile app. By not connecting, the user will,
however, not have the option to adjust combustion parameters or get access to combustion
data and overheating indication. We therefore recommend connecting the display panel and
making use of the mobile app.
1.6 Technical requirements for the mobile app
1.6.1 Android
A device running Android 5 Lollipop or higher
Bluetooth LE
GPS –Global Positioning System services
The application is available for download from Google Play under the name STORCH.
1.6.2 iOS
A device running iOS version 11 or higher
Bluetooth LE
GPS –Global Positioning System services
The app is available in the App Store under the name STORCH.
1.7 Technical description of the components
1.7.1 Cables
Type of cable insulation
Standard up to 55 °C

8
Gültig seit/Valid from/Valide: 09.10.2019
Silicon up to 180 °C
1.7.2 Servomotors
Parameters
Input voltage: 24 V/DC
Torque: 2 Nm standard servomotor; 2.5 Nm servomotor with return spring
1.7.3 Door switch
STORCH door switch connection:
Doors closed –switch contact disconnected
Doors closed –switch contact connected
Heat resistance of the STORCH door switch: 350 °C
2INSTALLATION
2.1 Installation procedure
2.1.1 Step 1 –Basic installation
a. Install the combustion thermal sensor into the smoke flue flow. Only the tip measures
temperature, the rest of the sensor is made of a heat-resistant material that can survive
temperatures of up to 1100 °C.
oInstall into the location prepared by the furnace’s manufacturer
b. Installation of the control unit in the plastic box
oInstall in an area specified by the manufacturer
c. Installation of the display panel –LED display
oinstall in the wood door
d. Installation of the door switch
oThe door switch automatically STARTS the burning regulator
oInstallation into the furnace’s frame (see the manual provided in the door switch
packaging)
2.1.2 Step 2 –Set up the burning regulator
Section 3.3 of the service menu describes how to setup the furnace.
2.1.3 Step 3 –Electrical connections
a. Connect the control unit to accessories according to the attached diagram (thermal
sensor, servomotor, door switch/start button)
b. Connect the control unit to the display panel with the 2-pin cable. On the display panel,
connect the blue conductor to the BU clamp and the brown conductor to the BN clamp.
c. Connect the 24 V/DC power adapter.
If installed in an environment with high industrial interference, use a voltage
filter and surge protection.

9
Gültig seit/Valid from/Valide: 09.10.2019
2.1.4 Step 4 –Download and install the mobile app
The app can be downloaded in Google Play (for Android systems) and the Apple Store (for iOS
systems). When installing STORCH, simply follow the instructions given by the mobile app. The
STORCH app is available in Google Play or the App Store.After opening the details of the app and
clicking on INSTALL, the app will be installed automatically.
2.1.5 Step 5 –Pair the regulator with the mobile app
a. Connect the regulator to a power source and wait for the optical signal to stabilize
b. Activate Bluetooth on the mobile device.
c. Start the STORCH mobile app.
d. The app will ask permission to read the device’s location –first time only. Grant this
permission (required by the operating system in order to detect devices).
e. The app will start searching for any nearby regulators. Once a regulator is found, enter
the password 123456. This will pair the mobile app with the regulator.
Note: If the application did not ask you to enter a pairing password, check the
notification bar of your phone. For some phone types, Android will allow you to enter a
pairing password by clicking the notification in the phone bar.
f. If an update is found in menu 3.2 User Settings, perform the update.
g. The mobile application is now paired with the SIC 700 SMART controller
If a different regulator is to be paired to the mobile device, the previous mobile app and
regulator pairing must be cancelled. If this is not done, connection to the new regulator will
not be possible! The connection can be cancelled in the user settings.

10
Gültig seit/Valid from/Valide: 09.10.2019
2.2 List of components and Diagram depicting the basic connection of a burning
regulator

11
Gültig seit/Valid from/Valide: 09.10.2019
1. Flue gas thermal sensor –“TS” (green
connector)
2. Control unit
3. Display panel (blue connector)
4. Door switch (black connector)
5. Servomotor with Air flap (orange
connector)
6. 24 V/DC power adapter
7. M10 swivel nut
8. Sensor securing loop (sensor case)
9. Magnetic key
10. Servomotor plastic clamp
11. M4x20 screw
12. Servomotor distance washer
13. Servomotor cable
14. M4x8 screw
15. Door switch cable
16. LED display cable
17. M3x8 screw
18. 3x2 washer
19. M4x6 screw
2.3 Connection diagram
Standard connection cable for the servo
Cable insulation up to 55 °C
2.3.1 STORCH servomotor
T1 –thermal unit, type K (flue gas thermal sensor)
SERVO –STORCH servomotor with three-point control, 24 V/DC
DS –input for connecting the door switch or mechanical button
COM –cable connecting to the display panel

12
Gültig seit/Valid from/Valide: 09.10.2019
2.4 Installation and assembly regulations
2.4.1 Temperature sensor assembly

13
Gültig seit/Valid from/Valide: 09.10.2019
2.4.2 Door switch assembly

14
Gültig seit/Valid from/Valide: 09.10.2019
2.4.3 Assembly of the central unit

15
Gültig seit/Valid from/Valide: 09.10.2019
2.4.4 Servomotor assembly

16
Gültig seit/Valid from/Valide: 09.10.2019
2.4.5 Assembly of LED display

17
Gültig seit/Valid from/Valide: 09.10.2019
3DESCRIPTION OF THE MOBILE APP
3.1 Main screen
Settings
Go to the regulator settings, see the user settings and service menu sections.
Acoustic notification
Activation / deactivation of acoustic signaling of the control unit, see chapter 3.2 User settings.
If you turn acoustic notifications off, the regulator will not acoustically notify important
situations!
App colours
The app uses three colours to indicate temperature in the furnace.
grey –Standby mode
green –starting the fire (first phase)
–new loading
yellow –starting the fire (second phase)
–cooling down
red –burning time
App colours
by temperature
- grey
- green
- yellow
- red
Manual
restart
Course of combus on
- stand-by mode
- star ng the Fire
- burning me
- cooling down
- new loading
Ac va on / deac va on
of acous c signaling
Se ngs
Combus on mode
ECO - SMART - TURBO
Flue gas temperature
Air Flap posi on
Burning me
Combus on history
and max. temperature
graph
Stoking sta s cs
D - W - M - S

18
Gültig seit/Valid from/Valide: 09.10.2019
Combustion mode
ECO –the Air flap is partially shut (reduced combustion)
oUse this setting if you want the fire to burn at a lower intensity, for instance when
the heating area is already at the right temperature.
SMART –the Air flap is controlled automatically by the configured program
oUse this setting if you don’t want reduced or high-intensity combustion.
TURBO –the Air flap is nearly completely open (more intense combustion)
oUse this setting if you want to increase the furnace’s heat output.
oTURBO mode is automatically used by the regulator whenever a new fire is started in
a cold furnace (the fuel needs more air to start the fire). The mode then switches to
the previously used setting after the next stoking.
Course of combustion (Burning cycle)
A graphical circular display shows the current combustion
stage.
1 - stand-by mode (grey) –(flap = 0%)
1-2 - starting the fire (green - yellow) –(fl. = 40-100%)
2-3 - burning time (red) –(flap = 30-100%)
3-4 - cooling down (yellow) –(flap = 30-100%)
4-1 - new loading (green) –(flap = 15%)
Flue gas temperature
The current temperature of the flue gas in the furnace.
Air flap position
The current position of the Air flap.
100 % = the shutter is completely open
0 % = the shutter is completely closed
Burning time
The current burning time (time elapsed since the start of regulation until transfer to standby
mode).
Combustion history and max. temperature graph
The graph displays the history of the previous 10 combustion cycles.
For each of these, the graph shows:
The maximum achieved flue gas temperature during combustion
Whether less (yellow column), optimal (green column) or more (red column) fuel was
stoked
Stoking statistics
Stoking figures for the last day (D), week (W), month (M) and total since the last reset of
statistics (S).
The statistics can be reset in the user settings.

19
Gültig seit/Valid from/Valide: 09.10.2019
3.2 User settings
Click on the symbol to enter user settings.
Update ( see 2.1.5 Step 5 –Pair the regulator with the mobile app )

20
Gültig seit/Valid from/Valide: 09.10.2019
Notifications
Configure notifications for different events.
The notifications will be displayed in the notification panel of your phone or tablet.
Notifications can be set for
Requests for the next stoking
Reminders to close furnace doors
Combustion mode
Set the combustion mode. You can select between three modes (ECO, SMART, TURBO), see
section 3.1.
Statistics reset
Reset the stoking statistics. This will reset the stoking counter to zero.
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

vacuubrand
vacuubrand VACUU-SELECT Instructions for use

Nevco
Nevco 486 Operator instructions

Neousys
Neousys Nuvo-1000 Series user manual

Panasonic
Panasonic CZ-256ESMC2U installation instructions

Advantage Controls
Advantage Controls MegaTronMT manual

National Instruments
National Instruments PXI-8109 installation guide