A 2.4 PURGE ADJUSTMENT SAR
A2.4 Purge Adjustment
Before attempting to check or reset the purge on
dryer, ensure that the dryer is operating in the purge
mode of the cycle ie. one column at working
pressure, one column at atmospheric pressure.
Before removing the exhaust silencers it is essential
that the cam timer be stopped. The cam timer is
stopped as follows:-
1. Pneumatic product, disconnected the 4mm pipe
to the air motor and seal the end of the pipe.
2. Electrically controlled SAR product, disconnect
the 4mm pipe to the electric interface located on the
top of the cam timer box.
Once the cam timer is stopped, unscrew the two
exhaust silencers located in the control shroud at
the front. Using a 1" BSP plug, blank off one of the
exhaust ports so that all the purge air escapes
through one port. Ensure that the flow meter to be
used has a full scale deflection larger than the
required purge flow.
Using 1" BSP flexible hose, connect from the
exhaust port to the inlet of the flow meter NB. never
allow the float of the flow meter to go off the top of the scale, and never pressurise the flow meter.
Using the brass purge plug, adjust the purge flow to the correct flow rate for the dryer, this must be carried
out with the dryer at its MINIMUM operating pressure. On certain dryers there will be two purge plugs, on
these dryers it is recommended that the plug nearest the inlet and outlet be fully open and the plug inside the
control shroud be used for fine adjustment.
Once the purge flow is set, remove the flow meter and the 1" BSP plug and replace the silencers. Re-start
the cam timer according to its type. Ensure that the dryer cycles correctly.
Purge Settings
Specific purge setting may vary from site to site according to operational/enviromental conditions. In general
for up to 35˚C inlet temperatures the table below gives recommended flow settings for both -40˚C and -70˚C
PDP. Purge flow rates are factory set to 6barg (88 CFM). This may need to be re-set by a Sullair trained
installation engineer at other operatiing pressures during commissioning.
SAR
Code
SAR 180
SAR 270
SAR 360
SAR 450
SAR 540
SAR 630
SAR 720
SAR 900
Purge flow rate
CFM (73-147 PSIG)
714
1070
1427
1784
2141
2498
2855
3568