Sun StorEdge™
Fast Write Cache 2.0 SBus
NVRAM Card Installation Guide
Part No. 806-6353-10
August 2000, Revision A

Please
Recycle
Copyright 2000 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 U.S.A. All rights reserved.
This product or document is distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or
document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party
software, including font technology, is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in
the U.S. and other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, and Solaris are trademarks, registered trademarks, or service marks of Sun
Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks
of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by
Sun Microsystems, Inc.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun’s written license agreements.
Federal Acquisitions: Commercial Software—Government Users Subject to Standard License Terms and Conditions.
DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-
INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2000 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303-4900 Etats-Unis. Tous droits réservés.
Ce produit ou document est distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la décompilation. Aucune
partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l’autorisation préalable et
écrite de Sun et de ses bailleurs de licence, s’il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de
caractères, est protégé par un copyright et licencié par des fournisseurs de Sun.
Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque
déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.
Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, et Solaris sont des marques de fabrique ou des marques déposées, ou
marques de service, de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays. Toutes les marques SPARC sont utilisées sous licence et
sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d’autres pays. Les produits portant
les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc.
L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun
reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique
pour l’industrie de l’informatique. Sun détient une licence non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence
couvrant également les licenciés de Sun qui mettent en place l’interface d’utilisation graphique OPEN LOOK et qui en outre se conforment aux
licences écrites de Sun.
LA DOCUMENTATION EST FOURNIE “EN L’ETAT” ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES
EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS
NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION
PARTICULIERE OU A L’ABSENCE DE CONTREFAÇON.

1
SunStorEdge™FastWriteCache2.0
SBus NVRAM Card Installation
Guide
This document replaces Chapter 2 of the Sun StorEdge Fast Write Cache 2.0 System
Administrator’s Guide. It is intended to communicate the SBus NVRAM board
installation procedure to Sun™ customers and support personnel. Here is a brief
summary of the installation procedure, with pointers to the detailed information in
this document:
▼Board Installation Procedure Summary
1. Perform a system shutdown:
/etc/shutdown.
2. Following the instructions in your system manual, remove your I/O boards from
the slots into which you will insert the SBus NVRAM cards.
3. Follow the “Electrostatic Discharge Precautions” on page 3.
4. Proceed to “Enabling the NVRAM Card Batteries” on page 4.
5. Install the card (“Installing the NVRAM Cards” on page 8).
SBus NVRAM Board Features
The SBus NVRAM card is a single-wide memory board with the following features:
■Solaris™ system software kernel driver
■Host-based fast write cache

2Sun StorEdge Fast Write Cache 2.0 SBus NVRAM Card Installation Guide • August 2000
■Battery backed-up data retention minimum of 75 hours, during power loss
■ECC for single-bit error detection and correction, and double-bit error detection
■SDRAM memory modules for fast access to persistent storage
■Maximum power dissipation of less than 13 watts
■Data mirroring between NVRAM cards
■Sustained write performance of 114 MBytes per second
A maximum of one pair of cards is supported per system or domain.
This document covers the following topics:
■“Qualified Platforms” on page 2
■“Electromagnetic Compatibility Compliance (EMC)” on page 3
■“Error Detection and Correction Capability” on page 3
■“Electrostatic Discharge Precautions” on page 3
■“Enabling the NVRAM Card Batteries” on page 4
■“Installing the NVRAM Cards” on page 8
■“Configuration Data” on page 10
Qualified Platforms
The following platforms are qualified for the SBus NVRAM card.
Sun Enterprise™ 3000 and 3500
Sun Enterprise 4000 and 4500
Sun Enterprise 5000 and 5500
Sun Enterprise 6000 and 6500
Sun Enterprise 10000

Sun StorEdge™ Fast Write Cache 2.0 SBus NVRAM Card Installation Guide 3
Electromagnetic Compatibility
Compliance (EMC)
The NVRAM card has been tested for EMC (USA FCC, Canada DOC, Japan VCCI,
and EU CE Mark). When installed and operated in accordance with this guide, the
EMC class marked on your Sun server label remains the same.
Error Detection and Correction
Capability
Data is stored in 64-bit double long words, with 8 check bits for each double long
word. This gives the NVRAM card the capability to detect all double-bit errors and
correct all single-bit errors in a single 64-bit double long word. The NVRAM card
cannot detect errors of 3 or more bits within the same nibble.
Because the check bits are generated and checked for the entire 64-bit word, all
writes to memory that are less than 8 bytes wide require a read-modify-write cycle
to memory. The following occurs in the read-modify-write cycle:
1. Existing 64 data bits and 8 check bits are read.
2. The bytes to be written are merged into the data.
3. New check bits are generated.
4. The resulting 64 data and 8 check bits are written back to memory.
Electrostatic Discharge Precautions
Circuit board components are vulnerable to damage by electrostatic discharge (ESD).
An electrostatic charge can build up on the human body and discharge when you
touch a board. Such discharge can be produced by walking across a carpet and
touching a board, or by other similar causes. Touch a conductive surface of the
chassis or other element connected to common earth ground to discharge the static
electricity present in your body.

4Sun StorEdge Fast Write Cache 2.0 SBus NVRAM Card Installation Guide • August 2000
To minimize the risk of ESD damage:
■Handle the card by the edges only
■Store the card in the antistatic bag provided
■Use a grounding strap whenever you work on a circuit board
Enabling the NVRAM Card Batteries
The NVRAM card is shipped with the batteries disabled to prevent battery drainage
during shipment.
Caution – Handle the NVRAM card with care to avoid damage. Wear an antistatic
wrist strap when handling the card. Hold the card by its edges only, and do not
touch any of the components on the card.
Do not place the NVRAM card on a metal surface, as it may discharge the batteries
regardless of the battery jumper settings. If you must put the card down, place it in
its antistatic bag.
Note – You must enable the batteries using the following procedure before you
install the hardware.

Sun StorEdge™ Fast Write Cache 2.0 SBus NVRAM Card Installation Guide 5
FIGURE 1 SBus NVRAM Card
▼To Enable the SBus NVRAM Card Batteries
1. Attach the antistatic wrist strap’s adhesive copper strip to the metal casing of the
power supply. Wrap the other end twice around your wrist, with the adhesive side
against your skin.
2. Remove the card from the antistatic bag. Hold the card by its edges and place it,
component side up, on the bag.
Use antistatic bags as a protective cushion for the SBus NVRAM card.
3. Look for the battery jumpers.
The SBus NVRAM card holds two batteries. Each has its own jumper, and both
batteries must be activated.

6Sun StorEdge Fast Write Cache 2.0 SBus NVRAM Card Installation Guide • August 2000
FIGURE 2 NVRAM Card Showing Location of Jumpers and Jumper Pins
4. Put the jumpers on the jumper pins.
When you unpack the card, the jumpers are inserted on only one pin of each pair,
leaving the battery disabled.
FIGURE 3 Detail of Jumpers and Jumper Pins With Batteries Disabled
a. Use tweezers or needle-nosed pliers to lift each jumper off the single pin and
align it with both pins.
b. Press the jumper in place on top of the pair of jumper pins.
FIGURE 4 Detail of Jumpers and Jumper Pins With Batteries Enabled
SBus NVRAM Card
The SBus NVRAM card has 256 MBytes of non-volatile memory. Due to SBus
addressing limitations, only 254.5 MBytes of memory is available to the computer
system. The Fast Write Cache 2.0 software is currently qualified with a maximum
cache size of 64 MBytes. Therefore, the cache size reported by the software is 64
Jumpers and jumper pins

Sun StorEdge™ Fast Write Cache 2.0 SBus NVRAM Card Installation Guide 7
MBytes. Fast Write Cache may eventually be released in a version that uses all of the
NVRAM card memory. The command that reports NVRAM hardware status shows
the NVRAM card size as 254 MBytes:
% fwcadm nvram -s
The resulting display will be similar to this:
Note – You must install two NVRAM cards of the same memory size in a system or
domain. For example, if you put a 32 MByte and a 254.5 MByte NVRAM card into
the same system or domain, the Fast Write Cache software would not enable the
cache.
The memory array on the 254.5 MByte, MM-1370 NVRAM is backed up by recharge-
able batteries. The calculated backup time at an operating temperature of 25 degrees
Centigrade and worst-case RAM power requirement is 75 hours minimum.
Caution – The batteries on the SBus NVRAM card are not customer-replaceable
parts. They may explode if mishandled. Do not dispose of a battery in fire. Do not
disassemble it. If a battery fails, call your authorized Sun service provider.
The batteries on the card will be fully charged or charging when you turn the system
power on. The batteries will discharge when the system power is turned off and the
battery jumpers are in the enabled position. If the system is off for extended periods
of time then the batteries will become low. When the system is turned on and the
batteries are low, the Fast Write Cache software will not enable the cache. Wait until
the batteries are fully charged, (5 hours or less) then manually enable the cache by
using this procedure:
▼To Manually Enable the Cache
1. Become superuser (root).
2. Enter the CLI shell by typing:
# /usr/opt/SUNWesm/bin/esm_cli
Device Size Inst Parent Status Dirty Battery UCE CE Mirror
________________________________________________________________________________
nvram0 254 MB #0 sbus #0 Active 1 Good 0 0 nvram1
nvram1 254 MB #1 sbus #1 Active 1 Good 0 0 nvram0

8Sun StorEdge Fast Write Cache 2.0 SBus NVRAM Card Installation Guide • August 2000
3. Enable the cache:
Use the following command to check the status of the batteries:
% fwcadm nvram -s
Fully-discharged batteries take 5 hours to charge. If your system has been powered
on for longer than 5 hours and the batteries are still low, then they have failed. You
must then replace the NVRAM card.
Note – The 3-battery SBus NVRAM cards do not have rechargeable batteries. Refer
to the installation and battery information in the Sun StorEdge Fast Write Cache 2.0
System Administrator’s Guide for details.
Installing the NVRAM Cards
You must enable the NVRAM card batteries before installing the cards. Make sure
you have performed the procedure in the previous section before continuing.
Note – To use Fast Write Cache, a pair of SBus NVRAM cards must be installed on
your system.
Each SBus supports only 256 MBytes of address space. This address space is shared
between all SBus slots on the same SBus. As a result of this limitation, it is very
important that you install the NVRAM cards on different SBusses. The best way to
ensure this is to install the NVRAM cards on different I/O cards.
This also improves the availability of the Fast Write Cache product in the event that
one I/O card fails.
If your server contains more than one I/O card, install each NVRAM card on a
different I/O card or bus to prevent the failure of a single I/O card from rendering
the cache unavailable during a system recovery.
[1] sx> cd cache
[2] sx> control -e

Sun StorEdge™ Fast Write Cache 2.0 SBus NVRAM Card Installation Guide 9
▼To Install the SBus NVRAM Cards
Note – Refer to your system installation or service manual for detailed instructions
for the following tasks.
1. Power off your system.
2. Open the system unit.
3. Attach the antistatic wrist strap’s adhesive copper strip to the metal casing of the
power supply. Wrap the other end twice around your wrist, with the adhesive side
against your skin.
4. Identify the slot in which you want to insert the NVRAM card.
5. Disconnect the SBus filler panel from the slot that you selected.
6. Position the NVRAM card on the system board over the SBus socket.
7. Carefully insert the NVRAM card into the SBus socket.
The carrier is keyed so the NVRAM can be installed only one way.
8. Push the NVRAM into the socket until it is properly seated.
9. Detach the wrist strap, replace the unit cover, and power on the system.
10. Install the Fast Write Cache software. Refer to the Sun StorEdge Fast Write Cache
2.0 Installation Guide for installation instructions.
▼To Verify the Installation
Note – The Fast Write Cache software must be installed before verifying the
installation of the NVRAM cards. See the Sun StorEdge Fast Write Cache 2.0
Installation Guide for the Fast Write Cache installation instructions.

10 Sun StorEdge Fast Write Cache 2.0 SBus NVRAM Card Installation Guide • August 2000
●As superuser, type the following command to verify that the NVRAM cards are
properly installed.
The system returns the status of all cards installed including the total amount of
memory in Mbytes, the dirty bit status, the battery status, the ECC errors, and the
mirror configuration.
Once the cards are installed it is transparent to you unless problems arise or the
batteries become low.
See the Sun StorEdge Fast Write Cache 2.0 System Administrator’s Guide. for a detailed
description of the fwcadm nvram -s display.
Configuration Data
The operating system keeps configuration data on the NVRAM card to keep track of
information such as the host ID, mirror pairs (primary and secondary), and the
number of NVRAM cards in the machine. During boot time, the operating system
uses this information to verify the NVRAM configuration.
#/usr/opt/SUNWesm/sbin/fwcadm nvram -s
Device Size Inst Parent Status Dirty Battery UCE CE Mirror
------------------------------------------------------------------------------
nvram0 254MB #0 SBus #0 Active 0 Good 0 0 nvram1
nvram1 254MB #1 SBus #0 Active 0 Good 0 0 nvram0
Other manuals for Sun StorEdge
3
Table of contents
Other Sun Microsystems Controllers manuals

Sun Microsystems
Sun Microsystems Serial Parallel Controller User manual

Sun Microsystems
Sun Microsystems Fire 6800 User manual

Sun Microsystems
Sun Microsystems Sun StorEdge A3500 User manual

Sun Microsystems
Sun Microsystems Fire 4810 Installation manual

Sun Microsystems
Sun Microsystems Sun Fire E6900 User manual

Sun Microsystems
Sun Microsystems SUN NETRA CP3000 User manual

Sun Microsystems
Sun Microsystems Sun StorEdge D1000 User manual

Sun Microsystems
Sun Microsystems Fire 6800 User manual

Sun Microsystems
Sun Microsystems StorEdge 5310 Manual

Sun Microsystems
Sun Microsystems RSM Array 2000 User manual