SurgiTel Surgical Mini LED User manual

Brightness About 100,000 lux (average)
Spot Size 4.0” Diameter (10cm) at 20” (50cm)
LED Beam Color Cool Light
Color Temperature 5,700K
LED Life
(Esmated on intensity used) Up to 10,000 hours or over 5 years
Lens Diameter 19mm
Weight (LED light unit) 14.6g
Baery Rechargeable Lithium Ion Baery,
7.4V 4,888 mAh
Baery Life Up to 12 hours
AC Charger Input: 100-240V, 50-60Hz, 0.35A
Output: +8.4V, 1.5A
PACKAGE CONTENTS
Doc No. 26939-
TECHNICAL DATA
®
•The user of this product should be thoroughly familiar with the use and
care of this product.
• The user should carefully study the manual before making any attempt to
use this product clinically.
• Before each procedure carefully inspect the LED system to ensure proper
maintenance.
• Use care not to point the light directly at the eyes during operation;
patient use of safety glasses is recommended.
FIRE HAZARD: DO NOT PLACE THE LED LIGHT UNIT ON ANY FLAMMABLE
OBJECT WHILE IT IS OPERATING.
WARNING:
• The LED light unit will get hot when left on. Handle with care. It is
recommended to turn off the LED before handling LED light or making any
adjustments to it.
• Avoid direct light contact with the eyes.
• Avoid direct light irradiation in patient’s eyes; patient use of safety glasses
is recommended.
Battery Charger & AC Power Adapter
• Use only the Battery Charger & AC Power Adapter supplied with this
system
• Do not disassemble, modify or short circuit
• Do not leave in hot places, such as inside a car or outside in hot weather
• Do not allow to get wet
Surgical Mini LEDSurgical Mini LED
USER INSTRUCTIONS
GENERAL WARNINGS
SurgiTel®
WARRANTY
SurgiTel’s mission is to provide the best products for your Vision & Ergonomics
at Work. To support this commitment SurgiTel® warranties all of its products.
SurgiTel® strives to make the best loupes and light systems available. Please
inspect and try on product immediately upon receipt. If you notice any issues,
contact our customer service department at 800-959-0153.
For both warranty and out-of-warranty issues, contact SurgiTel®Customer Service
regarding repairs.
Warranties vary by product. Check www.surgitel.com/warranty for more details.
Check www.surgitel.com/help for up to date care information/instructions.
Please keep up to date on care information/instructions, as warranties can be
affected if product is misused.
PATENT
True color beam family optics, U.S. Patent Numbers: US 9,383,077 B2;
US 9,494,299 B2
SurgiTel®
a division of General Scientific Corporation
77 Enterprise Drive • Ann Arbor, MI 48103-9503
E-mail info@surgitel.com • www.surgitel.com
•Surgical Mini LED Light and Cable
• SHL850 Battery Control Pack
• Universal AC Charger
• Accessory Kit
ADJUSTMENTS
• Protecon against electric shock: Class II including AC/DC Adapter.
• Applied parts : No applied parts.
• Protecon against harmful ingress of water: ordinary IPXO.
Direct current Class II
equipment
CE mark Serial No.
Alternang
current
Aenon, consult
accompanying
documents
CLASSIFICATION
Storing the LED system in a safe place will prolong the life of the unit. The
following guidelines will help in sustaining the LED systems useful life:
• Keep the opcal face on the light unit from touching hard surfaces which may
cause scratches on the surface. Scratches on the surface will diminish the light
quality.
• When cuts or punctures are visible on the system’s light cord, the LED
system is no longer safe to use; it should be taken out of service immediately.
MAINTENANCE
• Do not immerse in water or any liquid; wipe down with damp cloth. Do not use
HOT or COLD water; using “room-temperature” water is acceptable
• Avoid using running water and disinfectant sprays on or near open slots located
on light unit. Carefully wiping with damp cloth is ok.
• Do not use disinfectants containing glutaraldehydes, iodophors, ammonia,
alcohol, or ethanol.
• Do not autoclave
Disinfecon: Use of quaternary ammonium compounds is ok. Dry throughly. For a
full list of recommended disinfectants, visit www.surgitel.com/help
FACTORY REFURBISHMENT CLEANING: is available if you come across a dicult
cleaning situaon. Call customer support for details: 800-959-0153
*IMPORTANT*
CLEANING
OPERATION
• Aach the LED light to loupes or glasses using appropriate adapter
Note about light-cured composites
• Although it is not recommended to use this LED Light while working with
light-cured composites, seng the light to a lower light intensity may allow
you to work briey with materials before hardening
• Using the appropriate COLOR FILTER (orange lter) is STRONGLY
RECOMMENDED when using light-cured materials with the LED Light
• Ambient temperature range 10 to 40oC
• Relave humidity range 30 to 75%
• Atmospheric pressure range 70 to 106 kPa
• Ambient temperature range -40 to 70oC
• Relave humidity range 10 to 100%
• Atmospheric pressure range 50 to 106 kPa
OPERATING CONDITION
TRANSPORT & STORAGE CONDITION
Fixing Hinge Tension (too loose or too tight):
Step 1: Use provided hex key to remove hinge
set screw (see photo to the right)
Step 2: Use two at-head screwdrivers (placed
on each side) to loosen/ghten special
screw and nut
Step 3: Once desired tension is met,
reassemble and ghten set screw
• Charge Time (SHL850 Baery Control Pack) = approximately 2-3 hours
• Maximum connuous operaon at full load is up to 12 hours
• Aach the LED light to loupes or glasses using an appropriate adapter
• Use the included garment clips to route the cable appropriately
• LED cable inlet (1):
Provides power to LED light unit
• Power switch (2):
Rotate to turn light o/on
• Light intensity (2):
Adjust the posion of the knob to adjust
the light level
• Rechargeable inlet (3):
Recharges the baery with the aid of an
AC charger
• Baery charge level indicator light (4):
GREEN = fully charged, RED = charging,
FLASHING RED = Error
Warning:
SHL850 Baery Control Pack Belt Clip
• Improper use of the belt clip
can lead to product damage.
Refer to photos shown to the
right for correct use.
SHL850 Baery Control Pack
Placement
• Posioning the baery pack
incorrectly can lead to belt
clip damage. Refer to the photos
shown to the right for correct
• Aach light cord to frame by
sliding both o-rings onto
temple arm, as shown
Note: O-rings are aached to
LED cord
CABLE ROUTING
3
4
1
2
O-rings
Dove Tail Adapter Clip Adapter
ATTACHING LIGHT ADAPTER TO LOUPE

Other SurgiTel Medical Equipment manuals

SurgiTel Fixed Headband Light w/ Iris Operation manual

SurgiTel

SurgiTel Fixed Headband Light w/ Iris Operation manual

SurgiTel ErgoVision FLM User manual

SurgiTel

SurgiTel ErgoVision FLM User manual

SurgiTel Eclipse User manual

SurgiTel

SurgiTel Eclipse User manual

SurgiTel SkyLight User manual

SurgiTel

SurgiTel SkyLight User manual

Popular Medical Equipment manuals by other brands

Itamar Medical WatchPAT Operation manual

Itamar Medical

Itamar Medical WatchPAT Operation manual

PROTEOR 1P650 KNEE Assembling and adjustment instructions

PROTEOR

PROTEOR 1P650 KNEE Assembling and adjustment instructions

Liberate Medical VentFree user manual

Liberate Medical

Liberate Medical VentFree user manual

Dicarre DA20 user guide

Dicarre

Dicarre DA20 user guide

Stryker Medical M Series Operation manual

Stryker Medical

Stryker Medical M Series Operation manual

Invacare ScanBed 750 user manual

Invacare

Invacare ScanBed 750 user manual

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Getinge

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics Sonicator 730 Maintenance manual

Mettler Electronics

Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care R1100 Mounting instruction

Pressalit Care

Pressalit Care R1100 Mounting instruction

Denas MS DENAS-T operating manual

Denas MS

Denas MS DENAS-T operating manual

bort medical ActiveColor quick guide

bort medical

bort medical ActiveColor quick guide

AccuVein AV400 user manual

AccuVein

AccuVein AV400 user manual

agiliti NP Trio user manual

agiliti

agiliti NP Trio user manual

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Rocket Medical

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Monteris Medical Neuroblate Instructions for use

Monteris Medical

Monteris Medical Neuroblate Instructions for use

Otto Block 8E33 7 manual

Otto Block

Otto Block 8E33 7 manual

ADVANCED HOME CARE Helios Guide

ADVANCED HOME CARE

ADVANCED HOME CARE Helios Guide

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.