SVT innovations SVT-MF4 User manual

SVT-MF4 Outdoor Station D
User Manual
Please read this user manual prior to installing the system, and keep it well for future use.

CONTENTS
1. Parts and Functions.............................................................................................. 1
2. Terminal Descriptions .......................................................................................... 2
3. Specifications....................................................................................................... 3
4. Mounting ............................................................................................................... 3
5. System Wiring and Connections ......................................................................... 5
5.1 SVT-4 System with one entrance .................................................................... 5
5.2 SVT-4 System with two entrances .................................................................. 6
6. Cable Requirements ........................................................................................... 10
7. User Instructions . ............................................................................................... 11
5.3 SVT-4 Wiring Connection .............................................................................. 7
7.1 Visitor calls .................................................................................................... 11
7.2 Monitor .......................................................................................................... 12
7.3 Intercom ........................................................................................................ 13
4.1 Mounting without the Rain Guard..................................................................... 3
4.2 Mounting with the Rain Guard..........................................................................4
4.3 Mounting the Indoor Monitor............................................................................ 4
5.3.1 Indoor Station........................................................................................... 7
5.3.2 Outdoor Station........................................................................................ 7-8
8.How to set up User Codes ................................................................................. 14-15
5.3.3 Electric door lock connection ................................................................... 9

-1-
1.Parts and Functions
3
# Description
1
2
LED lights
3
High resolution camera
4
Built-in speaker
5
Call button
Built-in microphone
# Description
1 Built-in microphone
2 Monitor button
3 Intercom button
4 Door unlock button
5 Talk button
6 TFT 7” color display
7 Built-in speaker
8 Talking/Ring volume
9 Brightness
10 Contrast
Status light.
Calling in: red light
Monitoring/Talking: blue light
6Name plate
7Card Reader

-2-
2.Terminal Descriptions

-3-
160-165 cm
1 2
4.Mounting
Hatch
Install into the wall
Screw hole
Screws
(fix with button
case)
3.Specifications
OUTDOOR STATION
Voltage: DC 14.5V
NO/NC/COM: Max. 14.5V 200mA
Lock Power Supply: Must be used according to lock.
Unlocking time: 01 - 99 seconds
Communication duration: 120s.
Communication transmission: 2-way communication
Working temperature: -4°F to 131°F / -20°C to +55°C
INDOOR MONITOR
Voltage: DC 14.5V
Communication duration: 120s.
Communication transmission: 2-way communication
Working temperature: 14°F to 131°F / -10°C to 55°C
4.1. MOUNTING WITHOUT THE RAIN GUARD

-4-
Screw anchors
Screws
Screws
(fix with rain cover)
Rain cover
Wall hole
4.2. MOUNTING WITH THE RAIN GUARD
4.3. MOUNTING THE INDOOR MONITOR

-5-
5.1. SVT-MF4 SYSTEM WITH ONE ENTRANCE
System Wiring and Connections5.

-6-
5.2. SVT-MF4 SYSTEM WITH TWO ENTRANCES

-7-
5.3. SVT-4 WIRING CONNECTION
1. Red 2. Blue 3. Yellow 4. White
4-Video
1-Audio 2-GND 3-V+
5.3.1 Indoor Monitor
1. Red
2. Blue
3. Yellow
4. White
1. Red
2. Blue
3. Yellow
4. White
NOTE: Do not remove any of the jumpers from the back of the indoor
monitors.
By removing a jumper or changing its position, some of the features may
not work properly.
5.3.2 Outdoor Station
Upper module:
CN1: Must remain connected to CN10 port on the lower module.
Lower module:
PWR: Connect a SVT-MF4 PS17 Power supply.
J3: Use this port to connect a door lock. The door lock is limited to 14.5V, 200mA.
Must use an additional power supply for the door lock. Ensure the power supply is
compatible with the door lock specifications. The J3 output is also DRY contact (NO/COM/NC).
CN10: Must remain connected to J1 port on the upper module.
CN22: Reserved port.
JP1: Remove the black jumper if a access control unit is connected to the outdoor station
(SVT-3100 / SVT-4100 / SVT-5100 Access Control System only).
J1: Connect the access control unit (SVT-3100 / SVT-4100 / SVT-5100 Access Control
System only).
CN3: Reserved port.
CN2: Connect to the indoor monitor (Upper call button)
CN1: Connect to the indoor monitor (Lower call button)
CN1: Connect to the first Outdoor Station
CN2: Connect to the second Outdoor Station
Middle module:
PWR: Reserved port.
J4: Use this port to connect an exit button (Use red/black wire with 2 connections).
J1: Must remain connected to J1 port on lower module.
J3: Reserved port.

-8-

-9-
5.3.3 Electric Door Lock Connection
1. Use the port J3 of the lower module to connect a door lock.
2. The door lock is limited to 14.5V, 120mA.
3. Must use an additional power supply for the door lock. Ensure the power supply is
compatible with the door lock specifications.

6.Cable Requirements
B
A
Cable Usage A B
CAT5 cable (must solder the wires together to ensure a good connection).
Using different cables may affect the maximum distance the system can reach.
230 feet
70 meters
30 feet
10 meters
NOTE:
1. The system expands to a maximum of 2 outdoor stations and 4 indoor monitors.
2. Each indoor monitor requires its own power supply(14.5V, 1.3A)
3. We recommend soldering the wires together to ensure a good connection (Do not use
wire nuts).
-10-
4. For long runs typically longer then 90ft, we recommend using coax cable for the video function.

-11-
Press the call button at anytime, the
indoor monitor will show the view
from the front door camera
automatically. Press talking
button to have communication
with the visitor by the front door.
The visitor image shown on
the monitor
7.1 Visitor calls
Check
After pressing the unlocked button,
the indoor monitor still displays
the image from the front door
camera.
End the call
Talk begins
Open the lock
The talk time is
up to 2 minutes
Press the TALK
button or hang-up the
handset
The visitor presses
the call button
on outdoor
station-1
Ring Ring
The visitor presses
the call button
on outdoor
station-2
7.User instructions

-12-
All indoor monitors
ring
During the conversation
between the outdoor
station and the indoor
monitor, press button on
the main indoor monitor.
The indoor monitor press
button again to end the
conversation.
Call transferring from main indoor monitor to extension indoor
monitor
Any indoor monitor
press button or pick
up the handset to talk
with the outdoor station.
Press twicePress once
The indicator light of
Door 1 is on.
The indicator light of
Door 2 is on.
End the monitor
Press the
monitor
button
Monitor outdoor
station 1
Monitor outdoor
station 2
Press the
talk button
Press the
talk button
Monitor the
outdoor station
Press the
monitor
button
7.2 Monitor

-13-
End the call
All indoor monitors
ring
Press the TALKPress the
TALKING button or
hang-upbutton or hang-
up the handsetthe handset
Talk begins
Any indoor monitor
presses button or pick up
the handset to talk.
7.3 Intercom
In the standby mode,
press intercom
button in any
indoor monitor
During the talking, any indoor
monitor presses the intercom
button

-14-
8.How to set up the user codes
SVT-MF4 Outdoor Station D
requires the SVT Remote
Control for programming.
SVT REMOTE CONTROL works as a remote access control.
It is required to program the SVT-4 Outdoor Station D
settings, as registering and deleting fingerprints, unlocking
time and fingerprint security level.
SVT REMOTE CONTROL
Use two AAA alkaline batteries
Sensor working distance: +/- 20cm
Modify access control password
Press * and #, enter XXXX(the administration password) and #. A Di
sound indicates in the setting mode. Press * to return to standby
mode. (No operation in 20 seconds will return automatically). The
factory default password is 4567.
In the setting mode
In the setting mode:
Press 8 with a Di sound, then enter new 4-digits password (XXXX)
and #. After a Di sound, re-enter the new 4-digit password and #. If
two Di sounds is heard, it means the modification is successful.
If enter different passwords twice, continued Di... sound will be
heard, the modification of password fails. Please modify again.
Press * to return to standby mode.
If forget password, turn on the power again and press # for 3
seconds. If Bi is heard, default password is restored.

-15-
In the setting mode:
Press 0, a Di sound heard, and press 7 to hear another Di sound.
Then enter 6-digits master card number or swipe the master card.
After a Di sound, the setting is completed.
Press * to return to setting mode, and press * again to return to
standby mode.
Set master card
Delete user card
Add user card
In the setting mode:
Press 2 with a Di sound. It is in the delete card mode. Enter the last
6-digits of the deleted card. If a Di sound is heard, it indicates the
deletion is successful. Or swipe the deleted card, if a Di sound is
heard, and another Di sound indicates deletion is successful.
Continuous batch deleting user cards is available. If deleted card
is deleted again, the access control will sound four Di rejection
sounds. It indicates this card has been deleted.
Press * to return to setting mode, and press * again to return to the
standby mode. No operation in 30 seconds will return automatically.
In the setting mode:
Press 1. Di sound indicates it is in the adding user card mode.
Enter the last 6-digits of a new card number. If Di sound is heard,
it indicates the adding is successful. Or swipe the new card instead
of adding the card numbers. If a Di sound and another Di sound
are heard, it indicates the adding is successful.
Continuous batch adding new user cards is available. If a
registeredcard is added, four Di Di Di Di rejection sounds will be
heard. It indicates this card has been registered.
Press * to return to setting mode. Then press * to return to standby
mode. No operation in 30 seconds will return automatically.
Use master card to add user card:
In the standby status, swipe master card once. A Di sound indicates
it is in the adding card mode..
During the adding card mode, swipe each new card will accomplish
with a Di sound. Another Di sound to confirm that the setting is
successful. Registered card will be rejected. After four Di sounds,
swipe master card again to return to standby mode.

In the setting mode:
Press 4, a Di sound is heard, then enter 2 digits number from 01 to
99 as unlocking time. If a Di sound and another DI sound are heard,
it indicates the unlocking time setting is successful.
Press * to return to standby mode. No operation in 30 seconds will
return automatically.
Set building number and machine number
Set the unlocking time
Delete all user cards
In the setting mode:
Press 3, a Di sound is heard. Enter 6 digits (4-digits building No
and 2-digits machine number), press # with a Di sound. It indicates
the setting is successful.
Press * to return to standby mode. No operation in 30 seconds will
return automatically.
In the setting mode:
Press 9 with a Di sound heard. And then press 9, two short Di
sounds can be heard. After it stops, it indicates the deletion of all
user cards is successful.
Press * to return to standby mode. No operation in 30 seconds will
return automatically.


The design and specifications of this user manual can be changed without any notification to the user.
All copyright and interpretation rights are reserved to SVT Innovations Inc.
Table of contents
Other SVT innovations Intercom System manuals

SVT innovations
SVT innovations SVT-MF2 User manual

SVT innovations
SVT innovations SVT-2 Series User manual

SVT innovations
SVT innovations SVT-SMART 500 User manual

SVT innovations
SVT innovations SVT-IP A User manual

SVT innovations
SVT innovations SVT-2 User manual

SVT innovations
SVT innovations SVT-4 Outdoor Station C User manual

SVT innovations
SVT innovations SVT-2 User manual
Popular Intercom System manuals by other brands

urmet domus
urmet domus miro 1183 quick start guide

urmet domus
urmet domus SIGNO 1139 manual

M&S Systems
M&S Systems Linear DMC-10RS installation instructions

Telephone Technical Services
Telephone Technical Services DP3-AV user guide

Toa
Toa EX-630 Specifications

Clear-Com
Clear-Com HME DX210 operating instructions