W5 Smart
4
All rights to changes reserved. 2020 -11-19
1. General Description
The most important function of the ventilation system
is to ensure clean and fresh indoor air and to remove
moisture. The air in the home should be changed at
a continuous and sufficient rate to ensure a pleasant
indoor climate and avoid damage to building elements
caused by dampness. The ventilation unit should be
stopped only while service work is in progress.
1.1 Enclosure
The ventilation unit conforms to enclosure class IP34
when the cover is closed.
1.2 Fans
The Swegon CASA W5 is equipped with energy-efficient
fans with EC motors, advantageous in that their speed
is variably controllable and their efficiency is high even
when they operate in the lower speed range.
The fans can be controlled in four operating modes
from a Smart control panel or in three operating modes
from a compatible Swegon CASA cooker hood:
• Boost = large airflow is used when the ventilation re-
quirement increases, e.g. for cooking, taking a sauna,
showering or drying laundry.
• Home = normal airflow. Guarantees that there is suf-
ficient fresh indoor air for the home and the building
construction.
• Away = low airflow. Reduces power consumption
when the ventilation requirement in the home is small.
• Travelling = very low air flow and lower supply air
temperature. Used when no one is present in the home.
(Can only be selected from a Smart control panel.)
The unit’s weekly timer has four programs that can
switch in the various fan modes at the preset times.
On the unit with electric reheating, you can also select
the required temperature of the supply air. Even when
the ventilation unit is being controlled with the weekly
timer, it is always possible to change the fan mode from
a control panel or a cooker hood.
You can select an airflow boost time of 30, 60 or 120
minutes or continuous boost from a Smart control pan-
el. When the unit is controlled from a cooker hood, the
fan’s airflow boost time is 60 minutes. You can select a
damper open time of 30, 60 or 120 minutes.
1.3 Filter
The ventilation unit is equipped with supply air filter
according to filter class ISO ePM1 50% (F7) and with
extract air filter according to filter class ISO coarse (G3).
The need of filter replacement is indicated on the con-
trol panel and on a CASA Smart cooker hood.
1.4 Heat exchanger
The counter-flow plate heat exchanger in W5 is manu-
factured with aluminium fins and provides a high degree
of efficiency, up to 85 %. The incoming and outgoing
air flows in a counter-flow plate heat exchanger use
separate channels. Thanks to this the heat exchanger
does not return any odours or any moisture back into
the room air. The heat exchanger can be easily removed
from the unit for inspection and servicing.
1.5 Temperature
The user sets the required value for minimum supply
air temperature, and the ventilation unit then strives to
reach this temperature if possible. Swegon recommends
that the supply air temperature is set between 15–20 °C
and the factory setting is 17 °C, which is sufficient for
draught-free ventilation. The supply air temperature
should be 3–4 °C lower than the room temperature, so
that the supply air mixes fully with the room air.
Remember the following when setting the supply air
temperature:
• A high temperature setting will also increase the
ventilation unit’s power consumption.
• A low temperature setting, for example, 14 °C, can
cause condensation to collect in the system.
• The ventilation unit cannot cool the supply air without an
air cooler (duct coil), which is available as an accessory.
W5’s intelligent summer function helps to maintain the
home’s indoor air comfort even during hot summer days.
Very economical comfort coolness can be produced
Included in the delivery:
• Air handling unit
• Wall mounting bracket
• Adjustment foot (2 kpl)
• Condensate discharge tube
• Instructions for Use (FI, SE, EN + NO, DE)
• Installation, commissioning and maintenance
instruction (FI + SE)
Standard connections:
• Power supply cable with mains plug
• Modular cable with RJ9 connector (1.5 m)
• Free configurable I/O contacts for connection of
accessories (2 pcs.)
Accessories:
• Smart user panel
• Modular cable, 20 m, with adapter
• SEC: IO-extension cable with Modbus RTU (single
point connector)
• SEM: IO-extension module with relay and Modbus
RTU (in and out connectors)
• Duct mounted water heating/cooling coils
• Duct mounted electrical heater
• Smart sensors (RH, CO2, VOC)
• Constant duct pressure kit
• Smart Access Mobile Interface