manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. System Sensor
  6. •
  7. Security Sensor
  8. •
  9. System Sensor B501BI-IV User manual

System Sensor B501BI-IV User manual

1 I56-6903-000
INSTALLATION AND MAINTENANCE INSTRUCTIONS
B501BI-IV
ISOLATOR BASE
Xi'an System Sensor Electronics Ltd.
28 Tuanjie South Road
Xi'an Hi-tech Development Zone, 710075, China
Tel: 029-85387800 Fax: 029-88332959
SPECIFICATIONS
Model Number:
Height:
Diameter:
W
eight:
Operating Temperature Range:
Relative Humidity:
Operating Voltage Range:
Standby Curr
ent:
Maximum Current Draw
:
Maximum Load Current
:
Maximum ON Resistance (24V)
Maximum ON Resistance (15V)
Standard:
Ty p e :
B501BI-IV
20.3 mm
102.0 mm
44 g
-10°C~ 55°C
10%~ 93% RH
,
Non-condensing
15 ~32VDC
<150µA
17mA
(
device in isolation
)
1A
60mΩ
70mΩ
AS ISO 7240.17:2015
A
BEFORE INSTALLING
Please read the System Smoke Detectors Application Guide, which
provides detailed information on detector spacing, placement, zoning,
wiring, and special applications. Copies of this application guide are
available from System Sensor. Before installing and using the product,
please read the system wiring and installation manual thoroughly.
If the products will be installed in an existing operational system,
inform the operator and local authority that the system will be
temporarily out of service, disconnect power to the control panel before
installing the products.
This isolator base must be installed in compliance with the control
panel installation manual and meet the requirements of the authority
having jurisdiction. The installer must be familiar with these
requirements, with local codes, and any special requirements of the
authority having jurisdiction.
NOTICE: This manual should be left with the owner/user of this
equipment.
GENERAL DESCRIPTION
There is an automatic switch in the product that opens when the line
voltage drops below 4 volts. It is used to isolate the detector which is
connected in the communication line. In the event of a short circuit
condition on the communication line in the detector, the isolator base
will open its switch and disconnect the detector from the
communication line. When the short condition is removed and the line
voltage rises above 7 volts, the isolator base will detect the removal of
the fault condition and automatically reconnect the isolated detector.
Refer to Figure 1.
Remove power from initiating-device circuits before installing the
isolator base.
MOUNTING
Mount the detector base directly to a 4-inch square with plaster ring,
or a 3.5-inch octagon box.
Mounting hole spacing is 50mm, 60mm and 70mm, symmetrical
center.
WIRING INSTALLATION GUIDELINES
The B501BI-IV isolator base is intended to use in an Intelligent System,
There are five terminal blocks on the base (
Refer to Figure 1).
'COM+' = Positive power supply input / output
'COM-' = Negative power supply input / output / Negative
remote annunciator output
'OUT+' = Positive power supply output
'RA' = Positive remote annunciator output
For signal wiring (the wiring between interconnected detectors and
modules), it is recommended that the wiring be no smaller than 18
AWG (0.823 square mm). Wire sizes up to 12 AWG (3.31 square mm)
may be used with the base.
Note: Refer circuit wiring diagram Figure
2.
Note: Please dispose electronic waste following national or local
regulations after being scrapped or replaced. Do not discard.
FIGURE 1. APPEARANCE
A5665‐097
COM-
COM+
COM+
OUT+
RA
TYPE LOOP
ADDRESS
I56-6903-000
WARNING
2 I56-6903-000
FIGURE
2. WIRING DIAGRAM
FIGURE 3
.
THREE-YEAR LIMITED
WAR RANTY
Xi'an System Sensor Electronics Ltd. warrants its enclosed isolator base to be
free from defects in materials and workmanship under normal use and service
for a period of three years from date of manufacture. Xi'an System Sensor
Electronics Ltd. makes no other express warranty for this isolator base. No agent,
representative, dealer, or employee of the Company has the authority to increase
or alter the obligations or limitations of this Warranty. The Company’s obligation
of this Warranty shall be limited to the repair or replacement of any part of the
isolator base which is found to be defective in materials or workmanship under
normal use and service during the three year period commencing with the date
of manufacture. After phoning Xi’an System Sensor for a Return Authorization
Number and faxing a copy of the filled form of CUSTOMER RETURNS with
authorized RA# to Xi'an System Sensor Electronics Ltd. send defective units with
a copy of the form postage prepaid to: Xi’an System Sensor Electronics, Ltd./ 28
Tuan Jie South Road/ Xi’an National Hi-tech Industrial Development Zone,
710075/ China. Please include a note describing the malfunction and suspected
cause of failure. The Company shall not be obligated to repair or replace units
which are found to be defective because of damage, unreasonable use,
modifications, or alterations occurring after the date of manufacture. In no case
shall the Company be liable for any consequential or incidental damages for
breach of this or any other Warranty, expressed or implied whatsoever, even if
the loss or damage is caused by the Company’s negligence or fault.
Ver. A
FOR SYSTEM MONITORING – FOR TERMINALS COM+ AND COM-, DO NOT USE LOOPED WIRE UNDER
TERMINALS. BREAK WIRE RUN TO PROVIDE MONITORING OF CONNECTIONS.
A5665‐098
ISOLATE THE DETECTORS ON THIS ISOLATOR BASE
AND ON OTHER ISOLATOR BASES BEHIND THIS ONE
CONTROL PANEL
CLASS A OPTIONAL WIRING
REMOTE ANNUNCIATOR
(SELECTABLE)
REMOTE ANNUNCIATOR
(SELECTABLE)
REMOTE ANNUNCIATOR
(SELECTABLE)
+V1
-V1
+V2
-V2
No.1 No.2 No.n (n≤32)
+
-+
-+
-
RA RA
RA COM+
COM+ COM+
COM- COM-
COM- COM+
OUT+
COM+ COM+
OUT+ OUT+

Other System Sensor Security Sensor manuals

System Sensor B501 User manual

System Sensor

System Sensor B501 User manual

System Sensor CO1224T User manual

System Sensor

System Sensor CO1224T User manual

System Sensor B501B-FTX User manual

System Sensor

System Sensor B501B-FTX User manual

System Sensor 1112/24D User manual

System Sensor

System Sensor 1112/24D User manual

System Sensor 1451 User manual

System Sensor

System Sensor 1451 User manual

System Sensor B200SR User manual

System Sensor

System Sensor B200SR User manual

System Sensor B110RLP User manual

System Sensor

System Sensor B110RLP User manual

System Sensor B404B User manual

System Sensor

System Sensor B404B User manual

System Sensor SpectrAlert CH24MC Series User manual

System Sensor

System Sensor SpectrAlert CH24MC Series User manual

System Sensor 4451HTA User manual

System Sensor

System Sensor 4451HTA User manual

System Sensor RTS151KEYA User manual

System Sensor

System Sensor RTS151KEYA User manual

System Sensor 6424 User manual

System Sensor

System Sensor 6424 User manual

System Sensor B112LP User manual

System Sensor

System Sensor B112LP User manual

System Sensor 4451HT User manual

System Sensor

System Sensor 4451HT User manual

System Sensor 2351TEM User manual

System Sensor

System Sensor 2351TEM User manual

System Sensor ECO1005ABLINK User manual

System Sensor

System Sensor ECO1005ABLINK User manual

System Sensor DH400 User manual

System Sensor

System Sensor DH400 User manual

System Sensor L-Series User manual

System Sensor

System Sensor L-Series User manual

System Sensor WFDE Series User manual

System Sensor

System Sensor WFDE Series User manual

System Sensor CO1224T Instruction Manual

System Sensor

System Sensor CO1224T Instruction Manual

System Sensor 885-WP User manual

System Sensor

System Sensor 885-WP User manual

System Sensor 1424 User manual

System Sensor

System Sensor 1424 User manual

System Sensor B224RB User manual

System Sensor

System Sensor B224RB User manual

System Sensor B224RB User manual

System Sensor

System Sensor B224RB User manual

Popular Security Sensor manuals by other brands

Buckingham 60007 instructions

Buckingham

Buckingham 60007 instructions

PCB Piezotronics 1203-15A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 1203-15A Installation and operating manual

Vega VEGAPULS C 21 operating instructions

Vega

Vega VEGAPULS C 21 operating instructions

Zircon StudSensor L70 OneStep user manual

Zircon

Zircon StudSensor L70 OneStep user manual

BRITBE G3 PRO instruction manual

BRITBE

BRITBE G3 PRO instruction manual

Transmitter Solutions iGAZER50LR instruction manual

Transmitter Solutions

Transmitter Solutions iGAZER50LR instruction manual

Dynalog C-SCAN 2000 Series Operator's manual

Dynalog

Dynalog C-SCAN 2000 Series Operator's manual

Dräger X-plore 5500 Instructions for use

Dräger

Dräger X-plore 5500 Instructions for use

Bosch DS1103i installation instructions

Bosch

Bosch DS1103i installation instructions

GE Motion Sensor user manual

GE

GE Motion Sensor user manual

X4-Life 701445 user manual

X4-Life

X4-Life 701445 user manual

Aqara TH-S02D user manual

Aqara

Aqara TH-S02D user manual

Weco CDZ Series user manual

Weco

Weco CDZ Series user manual

Olympus EPOCH 6LT user manual

Olympus

Olympus EPOCH 6LT user manual

Heiman HM-807DWP manual

Heiman

Heiman HM-807DWP manual

suprema BioEntry Series installation guide

suprema

suprema BioEntry Series installation guide

iProTech Protect 1207i user manual

iProTech

iProTech Protect 1207i user manual

EVE 20EBG8701 Get started

EVE

EVE 20EBG8701 Get started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.