www.taco-hvac.com | 800.962.3783
QSTART-TS1P
Installation & Operation Guide
Please read this manual thoroughly to ensure
safe installation and proper operation.
Precautions
To prevent injury and property damage, follow these instructions.
Failure to adhere to installation/operation procedures and all
applicable codes may result in hazards as indicated by warning
codes outlined below:
indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury. This signal word is to be limited to the
most extreme situations.
indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury. It may also be used to alert against
unsafe practices.
This is the safety alert symbol. Read and follow instructions carefully to
avoid a dangerous situation.
This symbol alerts the user to the presence of “dangerous voltage”
inside the product that might cause harm or electrical shock.
DANGER
WARNING
CAUTION
Safety Instructions
Equipment starts automatically. Lockout/tagout before servicing.
As with all electrical products, read manual thoroughly. Only qualied,
expert personnel should perform maintenance and installation. Contact the
nearest authorized service facility for examination, repair, or adjustment.
Do not disassemble or repair unit unless described in this manual; death
or injury to electrical shock or re hazard may result. Specications and
manual data subject to change. Consult factory for additional information.
DANGER
CAUTION
1Ø AC Input 50/60 Hz
L1 L2
T1 T2
M
Voltage Input
Auto Run
Fault
Output
Status
Output
Dry Input
Auto Run
Normally Open
Input
12-120V
AC/DC
Input
Main Power Wiring
Wire main power input and output to the appropriate 12AWG wire leads utilizing
properly sized wire nuts. Use only copper conductors rated at least 60°C.
Maintain proper clearances and verify that no possibility of an electrical short
exists between the power conductors or enclosure. Ensure that wires are not
under stress and all insulation is intact.
Low Voltage Wiring
Automation system control wiring should be run in a separate conduit. The
control terminals accept 26~14AWG wire torqued to 3.5 in-lb.
Installation
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN DEATH OR
SERIOUS INJURY
Mounting
Mount the starter on a minimum 14 cu-in single gang junction box. To access
mounting holes, slide upper and lower covers to the open position.
(See Figure 1)
Using provided mounting screws (6-32 x 7/8”), attach starter housing to junction
box (once appropriate wiring has been completed).
• Do not locate starter in an environment subject to ammable gases, dusts or
materials. Contact arcing can induce explosion or re.
• Install starter in UL Type 1 (NEMA 1) appropriate locations only. Safe mounting
requires a dry, protected environment.
• The TS-1P is rated for maximum ambient temperature of 40°C
• Do not allow any metal shavings or debris from installation to enter enclosure.
DANGER
WARNING
Figure 1
HAZARDOUS VOLTAGE
• Disconnect and lock out all power before installing or servicing equipment.
• This equipment may require locking out multiple power sources prior to service
• Install and wire in accordance with all applicable local & national electrical and
construction codes
T
www.taco-hvac.com | 800.962.3783
QSTART-TS1P
3.288
4.984
2.808
1.427
2.147
HAND
RESET
AUTO
All dimensions in inches
Dimensions
Operation
Overload Adjustment
Conrm nameplate Full Load Amperage (FLA) to ensure proper overload
protection. Using a athead screwdriver, turn the adjustment dial to the desired
amperage setting. The starter is not rated to protect loads exceeding 16 amps @
120VAC, and 8.8A @ 230VAC.
LED Status Indicators
POWER (PWR)
Illuminates when voltage is applied to the input terminals and
main power switch is in the ON ()position.
RUN
Under a RUN condition, the RUN LED will remain illuminated if
the TS-1P senses current providing status. The LED will ash
when the unit does not sense current.
FAULT (FLT) - Overload Trip
The TS-1P indicates a fault condition by ashing the red FAULT
LED which will remain constant in the event of a fault trip. The LED
will also ash if a RESET attempt is made during the 180 second
overload cool down period.
Operation Modes
RESET
To reset the starter to normal operation following a Fault
condition, slide the 3-position switch to RESET and hold for
a minimum of 5 seconds (after 180 second cool down period
has elapsed). Once starter has been reset, return switch to the
desired mode.
MANUAL (HAND MODE)
In Manual or HAND mode, the TS-1P will function as a manual
motor controller. Select the ON ()position on the main power
switch to engage motor.
AUTOMATIC (AUTO MODE)
When utilizing the starter in the AUTO mode, a signal sent via
the terminal inputs (located on rear of unit) determine motor
operation (ON or OFF).
Lockout Options
To lockout, slide the lower cover upward to reveal concealed locking grasp.
Insert a standard padlock to prevent unauthorized access or tampering. If
multiple padlocks are required, an optional padlocking attachment can be utilized
(not included). See Figure 2B.
Figure 2A Figure 2B
HAND
RESET
AUTO
PWR
RUN
FLT
Product Ratings
1
2
3
4
5
6
Overload Adjustment
Operation Mode Selector
Main Power Switch*
PWR Power Status LED
RUN Run Status LED
FLT Fault / Overload LED
UL 508 Horsepower
Short Circuit Protection Interrupt
Current Max Current Overload Reset
115VAC 230VAC
TS-1P 1HP
Suitable for use on a circuit capable of delivering not more
than 1kA RMS Symmetrical Amperes, 230 Volts maximum
when protected by Class RK5 fuses (30 Amp max) or
inverse time circuit breaker (40 Amp max)
Ik ≤ 1kA RMS
Symmetrical
16A @ 120VAC
8.8 @ 230VAC I2t Class 10 Manual
1
2
3
4
5
6
*This device meets NFPA-70 (NEC) motor disconnect requirements per
paragraph 430.109 (C)(2) Stationary Motors of 2HP or Less.

This manual suits for next models

1

Other Taco Controllers manuals

Taco ZVC404-EXP-4 User manual

Taco

Taco ZVC404-EXP-4 User manual

Taco 0034ePlus User manual

Taco

Taco 0034ePlus User manual

Taco iWorX HPU3 User manual

Taco

Taco iWorX HPU3 User manual

Taco PC702–1 User manual

Taco

Taco PC702–1 User manual

Taco 0034e User manual

Taco

Taco 0034e User manual

Taco iWorx UCP-1 User guide

Taco

Taco iWorx UCP-1 User guide

Taco PC705-2 User manual

Taco

Taco PC705-2 User manual

Taco iWorx MPU2 User guide

Taco

Taco iWorx MPU2 User guide

Taco iWorx UCP-1 User guide

Taco

Taco iWorx UCP-1 User guide

Taco iWorX HPU2 User manual

Taco

Taco iWorX HPU2 User manual

Taco iWorx SMZ1 User guide

Taco

Taco iWorx SMZ1 User guide

Popular Controllers manuals by other brands

Genesys GL3520 Design guide

Genesys

Genesys GL3520 Design guide

RS PRO RS-270GT instruction manual

RS PRO

RS PRO RS-270GT instruction manual

Mi-Light FUT092 user manual

Mi-Light

Mi-Light FUT092 user manual

elero Combio-915 JA operating instructions

elero

elero Combio-915 JA operating instructions

GameSir G3w user manual

GameSir

GameSir G3w user manual

Addonics Technologies ADMS6GPX2-E user guide

Addonics Technologies

Addonics Technologies ADMS6GPX2-E user guide

Honeywell McDonald's HEMS II Operation manual

Honeywell

Honeywell McDonald's HEMS II Operation manual

Mitsubishi Electric MELSEC iQ-R Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series user manual

Mercury Security MS-ICS Installations and specifications

Mercury Security

Mercury Security MS-ICS Installations and specifications

Edgewater Networks EdgeMarc 4570 quick start guide

Edgewater Networks

Edgewater Networks EdgeMarc 4570 quick start guide

Brocade Communications Systems Mobility RFS6000 System reference guide

Brocade Communications Systems

Brocade Communications Systems Mobility RFS6000 System reference guide

MIT TRG-S-6 user manual

MIT

MIT TRG-S-6 user manual

Delta Electronics Programmable Logic Controller DVP04AD-H2 instruction sheet

Delta Electronics

Delta Electronics Programmable Logic Controller DVP04AD-H2 instruction sheet

Sevcon Dragon8 Applications Reference Manual

Sevcon

Sevcon Dragon8 Applications Reference Manual

Carrot LA3-TBL5D quick start guide

Carrot

Carrot LA3-TBL5D quick start guide

YASKAWA L1000A Series Technical manual

YASKAWA

YASKAWA L1000A Series Technical manual

Origin Effects RevivalDRIVE Footswitch user guide

Origin Effects

Origin Effects RevivalDRIVE Footswitch user guide

Unitronics UniStream US5-B5-B1 user guide

Unitronics

Unitronics UniStream US5-B5-B1 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.