Taylor Wawa C708 User manual

OPERATOR'S
MANUAL
Model C708 & C716
Heat Treatment
Soft Serve Freezers
Original Operating Instructions
059061-M January, 2005 (Original Publication)
(Updated 8/3/15)

Complete this page for quick reference when service is required:
Taylor Distributor:
Address:
Phone:
Service:
Parts:
Date of Installation:
Information found on the data label:
Model Number:
Serial Number:
Electrical Specs: Voltage Cycle
Phase
Maximum Fuse Size: A
Minimum Wire Ampacity: A
E2005 Carrier Commercial Refrigeration, Inc.
059061-M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this
work may be a violation of Copyright Law of the United States of America and other countries, could result
in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result
in further civil and criminal penalties. All rights reserved.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072

Models C708 & C716 Table of Contents
Table of Contents
Section 1 To the Installer 1............................................
Installer Safety 1........................................................
Site Preparation 1.......................................................
Air Cooled Units 2.......................................................
Water Connections (Water Cooled Units Only) 2............................
Electrical Connections 2.................................................
Beater Rotation 3.......................................................
Refrigerant 3...........................................................
Section 2 To the Operator 4...........................................
Section 3 Safety 5....................................................
Section 4 Operator Parts Identification 8...............................
Model C708 8..........................................................
Model C716 10..........................................................
Model C708 Single Spout Door and Beater Assembly 12......................
Model C716 Door and Beater Assembly 13..................................
X57029-XX Pump A. - Mix Simplified (Models C708 & C716) 14...............
Accessories 15..........................................................
Brush A.-Package-HT X44127 16..........................................
Section 5 Important: To the Operator 17.................................
Symbol Definitions 18....................................................
Operating Screen Descriptions 19..........................................
Freezer Locks 22........................................................
Manager's Menu 24......................................................
Section 6 Operating Procedures 33.....................................
Freezing Cylinder Assembly 33............................................
Freezer Door Assembly 35................................................
Mix Pump Assembly 39...................................................
Sanitizing 42............................................................
Priming 44..............................................................
Daily Closing Procedures 45..............................................
Daily Opening Procedures 46..............................................
Manual Brush Cleaning 47................................................
Draining Product From The Freezing Cylinder 47............................

Table of Contents Models C708 & C716
Table of Contents - Page 2
Rinsing 48..............................................................
Hopper Cleaning 48......................................................
Disassembly 49..........................................................
Brush Cleaning 50.......................................................
Section 7 Important: Operator Checklist 51..............................
During Cleaning and Sanitizing 51.........................................
Troubleshooting Bacterial Count 51........................................
Regular Maintenance Checks 51...........................................
Winter Storage 52........................................................
Section 8 Troubleshooting Guide 53....................................
Section 9 Parts Replacement Schedule 57...............................
Section 10 Limited Warranty on Equipment 58............................
Section 11 Limited Warranty on Parts 60.................................
Note: Continuing research results in steady improvements; therefore, information
in this manual is subject to change without notice.
Note: Only instructions originating from the factory or its authorized translation
representative(s) are considered to be the original set of instructions.
E2005 Carrier Commercial Refrigeration, Inc. (Original Publication)
(Updated August, 2015)
059061-M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this
work may be a violation of Copyright Law of the United States of America and other countries, could result
in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result
in further civil and criminal penalties.
All rights reserved.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072

1
Models C708 & C716 To the Installer
131121
Section 1 To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For
complete installation instructions, please see the
Installation Checklist.
Installer Safety
In all areas of the world, equipment should
be installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
SOnly authorized Taylor service personnel
should perform installation and repairs on
the equipment.
SAuthorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
SAuthorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and
service.
SAuthorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the freezer
must be disconnected prior to performing any
repairs. Failure to follow this instruction may result in
personal injury or death from electrical shock or
hazardous moving parts as well as poor
performance or damage to the equipment.
Note:Allrepairsmustbeperformedbyan
authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Site Preparation
Review the area where the unit will be installed
before uncrating the unit. Make sure that all possible
hazards to the user and the equipment have been
addressed.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70_-75_F(21_-24_C). The freezer
has successfully performed in high ambient
temperatures of 104_(40_C) at reduced capacities.
This unit must NOT beinstalledinanarea
where a water jet or hose can be used. NEVER use
a water jet or hose to rinse or clean the unit. Failure
to follow this instruction may result in electrocution.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should
be taken in moving this equipment for any reason.
Two or more persons are required to safely move
this unit. Failure to comply may result in personal
injury or equipment damage.
Uncrate the unit and inspect it for damage. Report
any damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.

2Models C708 & C716To the Installer
101027
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Model C708: Requires a minimum of 6” (152 mm) of
clearance on both sides and 0” in the rear of the
unit.
Model C716: Requires a minimum of 3” (76 mm) of
clearance on all sides. Install the deflector provided
to prevent recirculation of warm air.
This will allow for adequate air flow across the
condensers. Failure to allow adequate clearance can
reduce the refrigeration capacity of the freezers and
possibly cause permanent damage to the
compressors.
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided
with a hand shut-off valve. On the underside of the
base pan or on the right side, two 3/8” I.P.S. water
connections for inlet and outlet are provided for easy
hook-up. 1/2” inside diameter water lines should be
connected to the machine. (Flexible lines are
recommended, if local codes permit.) Depending on
local water conditions, it may be advisable to install
a water strainer to prevent foreign substances from
clogging the automatic water valve. There will be
only one water “in” and one water “out” connection.
DO NOT install a hand shut-off valve on the water
“out” line! Water should always flow in this order:
first, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an opentrapdrain.
A back flow prevention device is
required on the incoming water connection side.
Please refer to the applicable National, State, and
local codes for determining the proper configuration.
Electrical Connections
In the United States, this equipment is intended to
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety. In all
other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the
freezer for branch circuit overcurrent protection or
fuse, circuit ampacity, and other electrical
specifications. Refer to the wiring diagram provided
inside of the electrical box for proper power
connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. The
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipment's frame.

3
Models C708 & C716 To the Installer
130809
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3 mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent, or similarly qualified person, in order
to avoid a hazard.
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedures must be performed
by an authorized Taylor service technician.
To correct rotation on a three-phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single-phase unit, change
the leads inside the beater motor. (Follow diagram
printed on motor.)
Electrical connections are made directly to the
terminal block provided in the main control box,
located: C708 - behind the rear panel.
C716 - behind the lower front panel.
Refrigerant
In consideration of our environment, Taylor
uses only earth friendly HFC refrigerants. The HFC
refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and
non-flammable, with an Ozone Depleting Potential
(ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms
to the AHRI standard 700 specification. The use of
any other refrigerant may expose users and
operators to unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe,
apply ice packs and contact a physician
immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely
moisture absorbent. When opening a refrigeration
system, the maximum time the system is open must
not exceed 15 minutes. Cap all open tubing to
prevent humid air or water from being absorbed by
the oil.

4Models C708 & C716To the Operator
131121
Section 2 To the Operator
Your freezers have been carefully engineered and
manufactured to give you dependable operation.
These units, when properly operated and cared for,
will produce a consistent quality product. Like all
mechanical products, they will require cleaning and
maintenance. A minimum amount of care and
attention is necessary if the operating procedures
outlined in this manual are followed closely.
This Operator's Manual should be read before
operating or performing any maintenance on your
equipment.
Your Taylor freezer will NOT eventually compensate
for and correct any errors during the set-up or filling
operations. Thus, the initial assembly and priming
procedures are of extreme importance. It is strongly
recommended that personnel responsible for the
equipment's operation, both assembly and
disassembly, go through these procedures together
in order to be properly trained and to make sure that
no confusion exists.
In the event you should require technical assistance,
please contact your local authorized Taylor
Distributor.
Note: Your Taylor warranty is valid only if the parts
are authorized Taylor parts, purchased from the
local authorized Taylor Distributor, and only if all
required service work is provided by an authorized
Taylor service technician. Taylor reserves the right
to deny warranty claims on units or parts if
non-Taylor approved parts or incorrect refrigerant
were installed in the unit, system modifications were
performed beyond factory recommendations, or it is
determined that the failure was caused by abuse,
misuse, neglect, or failure to follow all operating
instructions. For full details of your Taylor Warranty,
please see the Limited Warranty section in this
manual.
Note: Constant research results in steady
improvements; therefore, information in this
manual is subject to change without notice.
If the crossed out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive as well as other
similar legislation in effect after August 13, 2005.
Therefore, it must be collected separately after its
use is completed, and cannot be disposed as
unsorted municipal waste.
The user is responsible for returning the product to
the appropriate collection facility, as specified by
your local code.
For additional information regarding applicable local
laws, please contact the municipal facility and/or
local distributor.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this unit are
warranted for the term stated in the Limited
Warranty section in this manual. However, due to
the Montreal Protocol and the U.S. Clean Air Act
Amendments of 1990, many new refrigerants are
being tested and developed, thus seeking their way
into the service industry. Some of these new
refrigerants are being advertised as drop-in
replacements for numerous applications. It should
be noted that in the event of ordinary service to this
unit's refrigeration system, only the refrigerant
specified on the affixed data label should be
used. The unauthorized use of alternate refrigerants
will void your Taylor compressor warranty. It is the
unit owner's responsibility to make this fact known to
any technician he employs.
It should also be noted that Taylor does not warrant
the refrigerant used in its equipment. For example, if
the refrigerant is lost during the course of ordinary
service to this machine, Taylor has no obligation to
either supply or provide its replacement either at
billable or unbillable terms. Taylor does have the
obligation to recommend a suitable replacement if
the original refrigerant is banned, obsoleted, or no
longer available during the five year warranty of the
compressor.
Taylor will continue to monitor the industry and test
new alternates as they are being developed. Should
a new alternate prove, through our testing, that it
would be accepted as a drop-in replacement, then
the above disclaimer would become null and void.
To find out the current status of an alternate
refrigerant as it relates to your compressor warranty,
call the local Taylor Distributor or the Taylor Factory.
Be prepared to provide the Model/Serial Number of
the unit in question.

5
Models C708 & C716 Safety
130225
Section 3 Safety
We, at Taylor Company, are concerned about the
safety of the operator when he or she comes in
contact with the freezer and its parts. Taylor has
gone to extreme efforts to design and manufacture
built-in safety features to protect both you and the
service technician. As an example, warning labels
have been attached to the freezer to further point
out safety precautions to the operator.
IMPORTANT - Failure to adhere to the
following safety precautions may result in
severe personal injury or death. Failure to
comply with these warnings may damage the
machine and its components. Component
damage will result in part replacement expense
and service repair expense.
DO NOT operate the freezer without
reading this Operator Manual. Failure to follow this
instruction may result in equipment damage, poor
freezer performance, health hazards, or personal
injury.
This appliance is to be used only by trained
personnel. It is not intended for use by children or
people with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge,
unless given supervision or instruction concerning
the use of the appliance by a person responsible for
their safety. Children should be supervised to ensure
that they do not play with the appliance.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. The
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipment's frame.
DO NOT use a water jet to clean or rinse
the freezer. Failure to follow these instructions may
result in serious electrical shock.
SDO NOT operate the freezer unless it is
properly grounded.
SDO NOT operate the freezer with larger
fuses than specified on the freezer data
label.
SAll repairs must be performed by an
authorized Taylor service technician.
SThe main power supplies to the machine
must be disconnected prior to performing
any repairs.
SFor Cord Connected Units: Only Taylor
authorized service technicians or licensed
electricians may install a plug or
replacement cord on these units.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3 mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic elastomer-
sheathed cord (Code designation 60245 IEC
57) installed with the proper cord anchorage
to relieve conductors from strain, including
twisting, at the terminals and protect the
insulation of the conductors from abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent, or similarly qualified person, in order
to avoid a hazard.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.

6Models C708 & C716Safety
130304
SDO NOT allow untrained personnel to
operate this machine.
SDO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
SDO NOT remove any internal operating
parts (example: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
SDO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
SUSE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
SCAUTION-SHARP EDGES: Two people are
required to handle the cup/cone dispenser.
Protective gloves must be worn and the
mounting holes must NOT be used to lift or
hold the dispenser. Failure to follow this
instruction can result in personal injury to
fingers or equipment damage.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
This freezer must be placed on a level
surface. Failure to comply may result in personal
injury or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to
the cleaning section of this manual for the proper
procedure to clean this unit.
This machine is designed to maintain
product temperature under 41°F (5°C). Any product
being added to this machine must be below 41°F
(5°C). Failure to follow this instruction may result in
health hazards and poor freezer performance.
DO NOT obstruct air intake and discharge openings:
C708: A minimum of 6” (152 mm) air space is
required on both sides and 0” on the rear.
C716: A minimum of 3” (76 mm) air space is
required on all sides. Install the deflector provided to
prevent recirculation of warm air.
Failure to follow these instructions may cause poor
freezer performance and damage to the machines.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70_-75_F(21_-24_C). The freezer
has successfully performed in high ambient
temperatures of 104_(40_C) at reduced capacities.
DO NOT run the machine without product. Failure to
follow this instruction can result in damage to the
machine.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.

7
Models C708 & C716 Safety
Notes:

8Models C708 & C716Operator Parts Identification
Section 4 Operator Parts Identification
Model C708
Figure 1

9
Models C708 & C716 Operator Parts Identification
110506
Model C708 Exploded View Parts Identification
ITEM DESCRIPTION PART NO.
1PANEL-SIDE-LEFT 056963
2PAN-DRIP 11-5/8 LONG 027503
3PIN-RETAINING-HOPPER CVR 043934
4KIT A.-COVER-HOPPER X65368
5BLADE A.-AGITATOR X56591
6PUMP A.-MIX SIMPLIFIED S.S. X57029-14
7PANEL-REAR 056077
8PAN A.-DRIP 5 1/2” LONG X56074
9SCREW-1/4-20X3/8 RHM-STNLS 011694
10 PANEL A-SIDE-RIGHT X57871
ITEM DESCRIPTION PART NO.
11 PANEL A.-FRONT-UPPER X59423
12 COVER-ACCESS-FRONT R. 056933
13 STUD-NOSE CONE 055987
14 SCREW10X3/8SLOTTED 015582
15 COVER-ACCESS-LEFT 056946
16 FILTER-AIR 052779-9
17 PANEL A.-FRONT-LOWER X58955
18 SHELF-TRAY-DRIP 056076
19 TRAY-DRIP 056858
20 SHIELD-SPLASH 049203

10 Models C708 & C716Operator Parts Identification
130129
Model C716
Figure 2

11
Models C708 & C716 Operator Parts Identification
120409
Model C716 Exploded View Parts Identification
ITEM DESCRIPTION PART NO.
1KIT A.-COVER-HOPPER X67061-AS
2BLADE A.-AGITATOR X56591
3PANEL-REAR 064258-SER
4PAN-DRIP 7.875 059737
5PUMP A.-MIX SIMPLIFIED X57029-14
6PANEL-SIDE-RIGHT 059907
7PANEL A.-FRONT SYRUP RAIL X63884-40
8PANEL A.-FRONT X59836
9PAN-DRIP 12.5 059736
10 PANEL A.-FILTER-LOUVERED X59928
11 FASTENER-DOOR STRIKE 030788
12 FILTER-AIR-POLY-FLO 052779-11
13 CASTER-4” SWV 3/4-10 STEM 044106
14 FASTENER-DOOR LATCH 030787
15 SCREW-1/4-20 X 3/8 RHM-SS 011694
ITEM DESCRIPTION PART NO.
16 PANEL-CORNER-FRONT
RIGHT 063087
17 CASTER-4” SWV 3/4-10 STEM
W/BRAKE 046437
18 DEFLECTOR 059929
19 PANEL A.-FRONT LOWER X59854-SER
20 TRAY-DRIP-19-5/8 L X 4-7/8 033812
21 SHIELD-SPLASH-WIRE-19-3/4 L 033813
22 PAN-DRIP 19-1/2 LONG 035034
23 PANEL-CORNER-FRONT-LEFT 063088
24 STUD-NOSE CONE 055987
25 PIN-RETAINING-HOPPER CVR 043934
26 PANEL-SIDE-LEFT 059906
*FASTENER-CLIP 1/4-20 045865
*NOT SHOWN

12 Models C708 & C716Operator Parts Identification
Model C708 Single Spout Door and Beater Assembly
Figure 3
ITEM DESCRIPTION PART NO.
1HANDLE A.-DRAW-WELDED X56246
2NUT-STUD-BLACK 2.563“ 058764
3DOOR A.-W/BAFFLE X57332-SER
4VALVE A.-DRAW X55820
5O-RING-DRAW VALVE-S.S. 014402
6PIN-HANDLE-SS 055819
7GASKET-DOOR HT 4”-DBL 048926
8BEARING-FRONT-SHOE 050348
9SHOE-FRONT HELIX *REAR* 050346
ITEM DESCRIPTION PART NO.
10 SHOE-FRONT HELIX *FRONT* 050347
11 BEATER A.-3.4QT-1 PIN X46231
12 BLADE-SCRAPER-PLASTIC 046235
13 CLIP-SCRAPER BLADE 7.00 046236
14 SHAFT-BEATER 056078
15 SEAL-DRIVE SHAFT 032560
16 NUT-STUD-BLACK 3.250” 058765
17 O-RING-1/4 OD X .070W 50 015872
18 SCREW-ADJUSTMT-5/16-24 056332

13
Models C708 & C716 Operator Parts Identification
140121
Model C716 Door and Beater Assembly
Figure 4
ITEM DESCRIPTION PART NO.
1DOOR A.-3SPT*HT*LG BAF X59923-SER
1a BAFFLE A.-LONG 4 IN X50882
2HANDLE A.-DRAW-WELDED X56421-1
3O-RING-1/4 OD X .070W 50 015872
4SCREW-ADJUSTMENT-5/16-24 056332
5GASKET-DOOR HT 4"-DOUBLE 048926
6PIN-HANDLE-TWIN 059894
7VALVE A.-DRAW X59888
8VALVE A.-DRAW*CENTER X59890
9O-RING--7/8 OD X .103W 014402
ITEM DESCRIPTION PART NO.
10 SEAL-DRAW VALVE H-RING 034698
11 NUT-STUD-BLACK 3.250 LONG 058765
12 NUT-STUD*BLACK 2.563 LONG 058764
13 KIT A.-BEATER-FRONT
SHOES-BEARING X50350
14 BEATER A.-3.4QT-1 PIN X46231
15 BLADE-SCRAPER-PLASTIC 046235
16 CLIP-SCRAPER BLADE 7.00” 046236
17 SHAFT-BEATER 032564
18 SEAL-DRIVE SHAFT 032560

14 Models C708 & C716Operator Parts Identification
140312
X57029-XX Pump A. - Mix Simplified (Models C708 & C716)
Figure 5
ITEM DESCRIPTION PART NO.
1-7 PUMP ASSEMBLY - MIX
SIMPLIFIED SOFT SERVE X57029-XX*
1CYLINDER-PUMP-HOPPER-SS 057943
2PIN-RETAINING X55450
3PISTON-PUMP-SIMPLIFIED 053526
4O-RING 2-1/8” OD - RED 020051
5CAP-VALVE BODY SS 056874-XX
6GASKET-SIMPLIFIED PUMP
VALVE 053527
7ADAPTOR - MIX INLET SS RED 054825
8O-RING - 11/16 OD - RED 016132
9PIN - COTTER 044731
10 SHAFT A.-DRIVE-MIX PUMP-
HOPPER X41947
ITEM DESCRIPTION PART NO.
10a CRANK-DRIVE 039235
10b SHAFT-DRIVE 041948
10c O-RING 1-3/4 OD X .139W 008904
10d O-RING 1/2 ID X .139W 048632
11 TUBE A.-FEED HOPPER (C708) X56521
12 TUBE A.-FEED RIGHT (C716) X59809
13 TUBE A.-FEED LEFT (C716) X59808
14 RING-CHECK .120 OD 056524
15 CLIP-MIX PUMP RETAINER 044641
16 SLEEVE A.- MIX PUMP *HT X44761
*NOTE: THE STANDARD PUMP X57029-XX IS -14.
OVERRUN CAN BE CHANGED HIGHER OR LOWER
BY SUBSTITUTING THE CAP (056874-XX) WITH
CAPS AVAILABLE -1 THROUGH -20. THE HIGHER
THE DASH (-) NUMBER, THE HIGHER THE
OVERRUN.

15
Models C708 & C716 Operator Parts Identification
140718
Accessories
Figure 6
ITEM DESCRIPTION PART NO.
1SANITIZER-STERA SHEEN *SEE NOTE
2TOOL-O-RING REMOVAL 048260-WHT
3TOOL-SHAFT-DRIVE-PUMP-
HOPPER 057167
4LUBRICANT-TAYLOR HI-PERF 048232
ITEM DESCRIPTION PART NO.
5PAIL-10 QT. 013163
** KIT A.-TUNE-UP (C708) X63146
** KIT A.-TUNE-UP (C716) X49463-82
** KIT A.-PARTS TRAY (C708) X57797
** KIT A.-PARTS TRAY (C716) X67432
*Note: A sample container of sanitizer is sent with the
unit. For reorders, order Stera Sheen part no. 055492
(100 2 oz. packs) or Kay-5 part no. 041082 (200 packs).
**Not Shown

16 Models C708 & C716Operator Parts Identification
100507
Brush A.-Package-HT X44127
Figure 7
ITEM DESCRIPTION PART NO.
1BLACK BRISTLE BRUSH 013071
2DOUBLE END BRUSH 013072
3WHITE BRISTLE BRUSH 1” x 2” 013073
4WHITE BRISTLE BRUSH
1-1/2” x 3” 014753
5WHITE BRISTLE BRUSH 1/2 x 3 033059
ITEM DESCRIPTION PART NO.
6BRUSH-SYRUP PORT 045079
7BRUSH SET (3) 050103
8YELLOW BRISTLE BRUSH 039719
9WHITE BRISTLE BRUSH 3” x 7” 023316
10 PUMP SPOUT BRUSH 054068
Other manuals for Wawa C708
4
This manual suits for next models
1
Table of contents
Other Taylor Freezer manuals

Taylor
Taylor C791 User manual

Taylor
Taylor 369 User manual

Taylor
Taylor C602 User manual

Taylor
Taylor 0738 User manual

Taylor
Taylor Horizon 8752 User manual

Taylor
Taylor C303 User manual

Taylor
Taylor 632 User manual

Taylor
Taylor 430 Torque User manual

Taylor
Taylor C707 User manual

Taylor
Taylor 428 User manual