TCS FBI6100-0400 User manual

www.tcsag.de PI_FBI610x_uk 3 A
Product information
SIP-Gateway
for 115 call destinations FBI6100-0400
for 10 call destinations FBI6101-0400

2 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Table of contents
Scope of delivery .................................................................................................................2
Please note!..................................................................................................................2
Safety instructions................................................................................................................3
Connections, indication and operating elements .................................................................3
Device overview...................................................................................................................5
Technical data .....................................................................................................................5
Intended use........................................................................................................................6
Short description..................................................................................................................6
Connect the lines.................................................................................................................6
Notes................................................................................................................................6
Connect the TCS system .................................................................................................6
Connect the network ........................................................................................................6
Wiring example operation mode ACTIVE.........................................................................7
Wiring example: operation mode PASSIVE .....................................................................7
Commissioning ....................................................................................................................8
Note..................................................................................................................................8
Error detection and indication...........................................................................................8
Start browser: connection establishment PC –SIP Gateway ..............................................8
Prepare the intranet connection .......................................................................................8
Example: network setup under Windows XP....................................................................9
Establish a network connection for configuration ...........................................................10
Enter / change IP address..............................................................................................11
Change the password ....................................................................................................11
Enter / change SIP settings............................................................................................12
Configure the phonebook...............................................................................................13
Adjust the switch time for door opener and light relay....................................................14
Programming the TCS front-door station........................................................................14
Operation...........................................................................................................................15
Door call from front-door station.....................................................................................15
Call from a telephone to a front-door station..................................................................15
Reload to factory settings...............................................................................................16
Service...............................................................................................................................16
Scope of delivery
1 x FBI610x-0400
1 x product information
Please note!
This product information describes the necessary steps to connect the FBI610x with a
TCS front-door station and with a SIP server.
For detailed information refer to the FBI610x user manual. You’ll find the manual for free
download under www.tcsag.de.

02/2014 3
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
Safety instructions
!
Attention! Mounting, installation, commissioning and repair of electronic devices have
to be carried out only by qualified electricians. Thus, the current standards for the in-
stallation of door communication systems must be observed!
For working with main connection of 230 V alternating voltage, the safety regulations ac-
cording to DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated conduit of heavy and low current lines,
minimum distance of 10 cm in case of a common cable conduit,
use of separators between heavy and low current lines within shared cable ducts,
use of standard communication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross-sections can be used in compliance
with the loop resistance.
!
With suitable measures to protect against lightning, it has to be ensured that a voltage
of each 32 V DC is not exceeded at the a- and b-wire.
Connections, indication and operating elements
Labelling
Function
19|20
connection for supply
voltage
Only operation mode ACTIVE! 8 - 12 V AC (from bell
transformer NWV1000-0400)
23|24|25
a*/b*/P*
connection TCS:BUS
ACTIVE
Only operation mode ACTIVE!
The SIP-Gateway realises the supply voltage for a
BUS strand.
In this operation mode, a front-door station can be
connected to the network at minimal effort.
One audio front-door station (incl. extensions) and 3
audio indoor stations can be operated in this mode.
The selection of connectable devices must be real-
ised in compliance with the max. quiescent current
output of the FBI610x.
Terminals are short-circuit protected.

4 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
28|29|30
a/b/P
connection TCS:BUS
PASSIVE
Only operation mode PASSIVE!
The supply voltage for the TCS:BUS is provided by an
additional power supply and control unit.
This operation mode is selected if the SIP-Gateway
is integrated into e.g. a video system, a system with
several front-door stations, resp. if the system
which is to be supplied exceeds the power output of
the SIP-Gateways.
Terminals are short-circuit protected.
21|22
Door release relay
(potential-free relay
contact –closing con-
tact)
door release voltage via bridge terminal 20 to 21
12 V, 50/60 Hz / 2 A (for door opener not less than
6 Ohm)
door release time can be adjusted: 0 to 99 sec
function can be adjusted via web interface
26|27
Internal light switch
relay (potential-free
relay contact –closing
contact)
To control automatic light switching units,
the following extensions can be connected:
automatic light switch unit (max. permitted contact
load capacity of 24 V DC / 1 A)
staircase light control unit FNA1000 (or TZ1-SG)
(with 8 - 24 V AC)
relay
adjustable light switch time: 0 to 99 sec
adjustable function via web interface
RJ45 socket
connection for network (PC/Laptop) 10/100 Mbit
RUN/PROG push
button
Only operation mode ACTIVE!
Switching of the system mode:
operation mode –programming mode
RUN
PROG
RUN/PROG indication
(LED orange)
indication of the system mode:
is ON: operation mode
blinks: programming mode
ERR
error indication at
TCS:BUS (LED red)
flashes: error in the connection to the TCS:BUS
(see page 8)
flashes OFF: error in the network connection (see
page 8)
2
indication operation
voltage (LED green)
is ON: operation voltage is present
3
indication status voice
connection (LED or-
ange)
indication voice connection or connection estab-
lishment FBI610x to an external device
4
error indication SIP
(LED red)
is ON: start process (around 40 sec) or no connec-
tion to the SIP server (see page 8)
status indication (LED
green)
blinks: if data is sent or received via LAN
is ON: connection FBI610x to the network is estab-
lished
status indication (LED
orange)
is ON simultaneously green with status indication:
no connection to the network

02/2014 5
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
Device overview
Technical data
housing: DIN-rail housing 6 SU for DIN-rail according to
DIN EN 60715 TH35
weight: 215 g
acceptable ambient temperature: 0 °C ... +40 °C
degree of protection: IP 20
operation mode ACTIVE
supply voltage: 8-12 V AC (from bell transformer NWV1000-0400)
output voltage idle state: U(a/b) = 24 V ± 1 V, U(b/P) = 26V ± 1V
output voltage speaking: U(a/b) = 22 V ± 1 V
output current: I(a) =40 mA,
max. output current: I(Pmax) = 180 mA
operation mode PASSIVE:
supply voltage: +26 V ±8 % (power supply and control unit)
input current: I(a) = 0.05 mA, I(P) = 27 mA
max. input current: I(Pmax) = 45 mA
connection RJ45
status indication
(LED orange)
status indication
(LED green)
error indication
at the TCS:BUS
(LED red)
RUN/PROG
indication
RUN/PROG-
push button
connection
supply voltage
indication for operation
voltage (LED green)
indication for status voice
connection (LED orange)
error indication
SIP (LED red)

6 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Intended use
The FBI610x is an interface for the connection of TCS front-door stations to a VoIP net-
work as end device (client) via Session Initiation Protocol (SIP).
The SIP-Gateway can be used generally in 2 operation modes at the TCS:BUS: opera-
tion mode ACTIVE or operation mode PASSIVE.
Short description
providing the voltage supply of 24 V DC (for TCS:BUS, only operation mode ACTIVE)
switching of the system mode between operation and programming mode,
LED indication (only in operation mode ACTIVE).
automatic detection of the operation mode PASSIVE or ACTIVE
potential-free relay contacts (closing contacts) to control automatic light switch units /
door opener
single speech channel:
Communication from front-door and indoor stations to more than one call destination is
not possible simultaneously.
optical indication for voice connection and operating voltage
error detection and indication for TCS:BUS and network errors
Connect the lines
Notes
Mounting, installation and commissioning must be carried out only by IT professionals!
!
Use a small screwdriver to connect the lines and to avoid damaging the device.
Connect the TCS system
Strip the ends of the lines.
Connect the TCS system to the FBI610x depending on the operation mode and the type
of system completely and according to the wiring example.
Connect the network
Establish a connection between the RJ45 interface at the FBI610x and your network by
using a patch cord.

02/2014 7
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
Wiring example operation mode ACTIVE
Wiring example: operation mode PASSIVE

8 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Commissioning
Install the devices of the system completely.
Check the a-, b- and P-wire against each other for short-circuits.
Switch on the mains voltage.
After switching on the voltage supply, the FBI610x starts automatically.
Note
!
The SIP Gateway restarts automatically after a voltage interruption, even if the
device was switched off.
!
Switching off the power supply during a storage process or software update can cause
a loss of data or a malfunction of the device.
Error detection and indication
Error at the TCS:BUS
Only operation mode PASSIVE: a-wire is not
connected / not supplied, a-b short-circuit or a-
and P-wire are interchanged / short-circuited
Only operation mode ACTIVE: a-b or a-P
short-circuited
ERR
error indication flashes
(1:7, 1 Hz)
Connect a-wire / check power
supply,
interchange a- and P-wire or re-
move short-circuit,
device is in standby mode again
Network error
defective network connection or no connection
to the SIP server
ERR
error indication
flashes out
(7:1, 1 Hz)
Check the network, check data
transmission, check login data for
SIP server,
device is in standby mode again
Network error
defective network connection or no connection
to the SIP server
4
error indication SIP
lights up *
Check the network, check the
data transmission, check the
SIP server,
device is in standby mode again
*No error during the start process, indication, lights up and expires after around. 40 sec if no error was detected.
Start browser: connection establishment PC –SIP Gateway
Prepare the intranet connection
The PC/Laptop must be equipped with a network connection and the device must be lo-
cated in the same subnet as the SIP-Gateway. If your network and server are working in
the 192.168.1 address area (C net), you can directly access the SIP-Gateway (provided
that another device does not use the IP address of the SIP-Gateway).
Otherwise the used PC/Laptop must be set temporary to an IP address within the address
area of the FBI610x to establish a connection with the SIP-Gateway. To install / modify
your network connection, please use the network installation assistant or the help menu of
your operating system (catchword: Install the network). If several FBI610x, which are in
delivery state, are to be installed within one network, the devices must be commissioned
one by one and assigned to a free IP address.

02/2014 9
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
To install the network connection, you eventually need administrator rights.
In delivery state, the following values are pre-set at the FBI610x:
IP address: 192.168.1.200, net mask: 255.255.255.0, password: 1234
To setup / adjust your network connection, please use the network installation assistant or
the help of your operation system (catchword: Network setup).
Example: network setup under Windows XP
Open the Network and data telecommunication connections in one of the following
methods:
1. Click with the right mouse button on the icon Network surrounding on the desktop and
select Settings.
or
2. Click the button Start (toolbar on your desktop) > Settings > System control > Network
connection.
Select LAN connection in the menu.
Select Settings.
Click Internet protocol (TCP/IP)
(see illustration).
Click Settings.
Activate Use the following IP-address.
Enter an IP-address, which differs from the one
of the TCS:Server only in its last digit, e.g.
192.168.1.5.
Enter the number of the subnet mask:
255.255.255.0.
Confirm with OK.

10 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Establish a network connection for configuration
Establish a connection from the PC/Laptop to the SIP-Gateway via switch or router.
Alternatively connect the SIP-Gateway directly to a PC/Laptop via a crossover cable
(twisted pair cable).
Open an internet browser.
Enter the IP address of the
SIP Gateway into the address line:
http://192.168.1.200
The start page is called.
Select Settings VoIP.
Enter the password (preset: 1234)
and select Register.

02/2014 11
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
Enter / change IP address
Manually configured IP ad-
dress is already selected.
Enter a free IP address
which belongs to the ad-
dress area of the required
network.
Enter the number of the re-
lated subnet mask.
Eventually also enter the IP
address of your DNS server.
Confirm with Save.
!
If the IP address was changed manually, the web browser can possibly no longer dis-
play the page with the feedback. If this is the case, enter the new IP manually into the
browser to get back to the start page. Eventually, change the address area of your
PC/Laptop again.
Change the password
Register under Settings VoIP. Select System in the navigation bar.
Enter your new password under Administrator password. You can also remove the
password if there is no need for security.
!
Please observe that without any password protection, the system can be manipu-
lated by anyone!
Click Save.

12 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Enter / change SIP settings
Register under Settings
VoIP.
Select SIP settings in the
navigation bar.
Enter here the necessary
data for your SIP server /
telephone system, which
you have determined during
the registration of the
FBI610x.
Click Save.
Note for user name:
This field is used only for information and
does not have a special function. You
can enter e.g. the position of the fron-
door station.
!
The Reset button resets the content to the latest stored data state. It does not reload
the factory settings.
SIP
registration
Displays, if the SIP-Gateway should register at the SIP-Server.
If this option is not activated, only direct connections (peer to peer) can be realised. Thus,
the IP-address of the SIP-device, that is to be called, must be entered in the phonebook. A
connection via call numbers cannot be realised.
SIP server
and SIP
server port
Enter the IP-address or URL of the SIP providers / SIP server. The port number shows to
which port the server belongs.
SIP domain
The SIP domain is used to identify devices and to establish a connection. Thus, the num-
ber is used within the SIP protocol (e.g. 1234@sipgate.de). Without the domain no connec-
tion via call number can be realised. Instead of a name also the IP-address of the SIP
server can be entered.
SIP server as
outbound
Proxy
Use the SIP server as proxy for outgoing calls. The SIP server has to support this function.
Thus, calling can be realised through a NAT firewall.
DNS SRV
Use the DNS server entry to call a device within the SIP domain.
SIP
User ID
The user ID is the ID within a SIP domain. The ID is used to identify the SIP-Gateway. In
case of an incoming call the allocation is realised via the user ID. A caller transmits the call
request as “<Call number>@sipdomain.de“ or as “<User-ID>@sipdomain.de“.
SIP authenti-
fication ID
User name to register at the SIP server.
SIP authenti-
fication PIN
Password to register at the SIP server.
user name
The user name field is only for your information. It has no special function. Here you can
enter e.g. the position of the front-door station.

02/2014 13
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
Configure the phonebook
In this menu a TCS:BUS serial number is connected to a SIP telephone number which is
to be called.
Register under
Phonebook.
Enter the required call
destinations for your
connected front-door
station.
Click Save.
Phonebook FBI610x-0400
with up to 10 resp. 115 call
numbers.
!
The Reset button resets the content to the latest stored data state. It does not reload
the factory settings.
Column
Function
name
This text is used only to inform the installer resp. for a better assignment of call number and
serial number to a resident or a flat. This text is only displayed here. This field is mandatory
and must be filled out. Otherwise the entry is inactive.
number
Entry of the selected SIP telephone numbers without special characters.
serial number
TCS:BUS serial number, which is to be programmed at the front-door station. The serial num-
ber has max. 6 digits. Shorter serial numbers are entered and displayed without leading ze-
roes. A pseudo serial number or a parallel serial number can be used.
incomming
Decision, how to react in case of an incoming call of the corresponding number. The following
can be selected: rejecting, automatic acceptance, automatic acceptance with playing a stored
announcement (the caller can hear it) and manual acceptance. The additional option “beep“
ensures that conversation partners hear a signal tone after the audio connection is established.
outgoing
Decision, if in case of an outgoing call, a stored announcement (e.g. position of the communi-
cation system) should be played for the caller.
group ID
Via the group ID, 10 different call chains can be determined. Phonebook entries with the identic
ID are handled as call chain. If an entry of this group is called by a front-door station and the
call is not accepted, all entries with the same ID are called one by one.

14 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Adjust the switch time for door opener and light relay
Register under Settings
hardware.
Select System in the navi-
gation bar.
Select the values.
The switch time is to be adjusted by
selecting numbers from 0…99 sec. The
left selection field adjusts the 10th sec-
onds, the right one the 1th seconds.
Programming the TCS front-door station
Program the serial numbers which are used in the phonebook of the FBI610x with con-
figo™ or TCSK-01 at the required buttons of your front-door station.
The buttons of the front-door station can be programmed also manually:
Switch on the programming mode of the system.
In the operation mode ACTIVE: Shortly press the RUN/PROG button at the FBI610x
or in the operation mode PASSIVE: Shortly press the RUN/PROG button at your
power supply and control unit. The RUN/PROG LED starts blinking.
First delete already programmed buttons by pressing the button for a long period (see
product information front-door station).
Call the FBI610x from the number which is allocated to the serial number in the phone-
book. Select a front-door station.
After the voice connection is established, shortly press the bell button which is to be
programmed. Although a negative acknowledgement tone sounds at the front-door sta-
tion, the button was successfully programmed.
!
This function is only available, if the corresponding phonebook entry under incoming
is not set on Reject.
The incoming call number at the FBI610x must be identic with the phonebook entry.

02/2014 15
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
www.tcsag.de PI_FBI610x_uk 3 A
Operation
Door call from front-door station
An incoming call is directly con-
nected to the front-door station by
accepting the call at the called
telephone (delivery state).
If the option confirmed ac-
ceptance (’7’) was activated (acti-
vation see user manual), the but-
ton 7 must be pressed to accept
the call. The controlling of the
FBI610x is realised via the MFV
dial of the connected telephone.
Call from a telephone to a front-door station
A telephone can establish a
connection to the FBI610x
only if the incoming SIP tele-
phone number is stored in
the phonebook and the cor-
responding entry under In-
coming is not set on Reject.
After the FBI610x has ac-
cepted the call, you have to
select the front-door station
via the telephone keypad.
See illustration Select front-
door station.
Using the binary output causes a configuration, see user manual of the FBI610x.

16 02/2014
www.tcsag.de PI_FBI610x_uk 3 A
Reload to factory settings
!
When loading the factory settings all VoIP and hardware settings are reset. The entries
in the phonebook remain unchanged.
IP address: 192.168.1.200, netmask: 255.255.255.0, password: 1234
Reload to factory setting
yellow LED lights up
yellow LED blinks
yellow LED blinks fast
yellow LED lights up
Press RUN/PROG
button and hold it…
keep RUN/PROG
button pressed …
…, until LED blinks, then
release
factory settings loaded
Service
!
First use the detailed formation and the FAQ in the user manual of the FBI610x. Find
the manual for free download under www.tcsag.de/Downloads.
Please send your questions and inquiries to
Headquarters
TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin
Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de
This manual suits for next models
1