TE Connectivity AST20PT User manual

TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12/2018
Page 1
Contents
Important Safety Instructions
2
Wiring Schematic
2
Cable Wiring
Standard & Conduit w/ Cable
3
Submersible Cable Wire
4
Connector Wiring
DIN (Form A, Form C)
5
Bendix™ (6 Pin, 4 Pin)
6
Packard™ Metri-Pack 150
7
Minifast™ and M12x1
8
DT04 DEUTSCH (6 Pin, 4 Pin)
9
Molex™
10
Pressure + Temperature Transmitter Wiring
Cable or Wire (Pressure & Temp.)
11
DIN Connector (Pressure & Temperature)
12
Bendix™, M12 & DT04 DEUTSCH (Pressure & Temp.)
13
INSTALLATION | WIRING GUIDE
AST Pressure Sensors
Hirschmann, Bendix, Metri-Pack, Minifast and Molex are trademarks of their respective owners.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 2
Important Safety Instructions
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION used with the safety alert symbol, indicates a hazardous
situation which, if not avoided, could result in minor or moderate injury.
Wiring Schematics
Output
mV
Voltage
0.5-4.5V ratiometric
1-5V, 1-6V, 0-5V
0-10V, 1-10V
Supply Voltage
5VDC typ., 10VDC max.
5VDC ± 0.01V
10-28VDC
15-28VDC
Output Load
>1 MΩ
>10 KΩ
>10 KΩ
>10 KΩ
Operating Temperature
-40 to 105ºC
-40 to 85ºC
-40 to 85ºC
-40 to 85ºC
Output
4-20mA
Mechanical Installation
Supply Voltage
10-28VDC
Use the hex flats closest to the process connection for installation into the
process. For conduit connections, hold the product at the hex closest to
the conduit connection.
Output Load
0-800Ω
Operating Temperature
-40 to 85ºC

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 3
Cable / Hookup
Wire Connections
Standard Cable
Conduit with Cable
AST Electrical Connection Option
”A, B, C, D”
“L, M, N, P”
Gauge Wire
24 AWG
24 AWG
Output Type
Green
Black
Red
White
mV & 4-Wire Voltage
+S
GND
+V
-S
3 Wire Voltage
N/C
GND
+V
S
4-20mA (2 wire loop powered)
N/C
-V
+V
N/C
CSA Certified Sensors
Output Type
Green
Black
Red
White
3 Wire Voltage
Case
GND
+V
S
4-20mA (2 wire loop powered)
Case
-V
+V
N/C
NOTICE FOR NON-INCENDIVE SENSORS INSTALLED IN [CLASS I, DIV 2, GROUPS A,B,C,D]
- Suitable for use in [Class I, Division 2, Groups A, B, C And D] Hazardous Locations, or Non Hazardous Locations only.
Explosion Hazard
- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations.
Explosion Hazard
- Substitution of any component may impair suitability for [Class I, Division 2]
NOTICE FOR INTRINSICALLY SAFE SENSORS
- Refer to the Intrinsically Safe Installation Manual for barrier installation information
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 4
Submersible
Cable / Hookup
Wire Connections
UL/CSA
Conduit with Cable
AST Electrical Connection Option
“N, P, X*”
Gauge Wire
22 AWG
*see data sheet for special options
Output Type
Green
Black
Red
White
Voltage
Case
GND
+V Supply
S
4-20mA (2 wire loop powered)
Case
-V Supply
+V Supply
N/C
NOTICE FOR INTRINSICALLY SAFE SENSORS - Refer to the Intrinsically Safe Installation Manual for barrier installation information.
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 5
DIN
DIN 43650A 18.0mm
Mini-DIN 43650C 8.0mm
AST Electrical Connection Option
“I”
“E”
Mates w/
931 970-100 [conduit] or equivalent
933 023-100
AST Mating Connector Part #
A09171
A01980
NOTICE FOR INTRINSICALLY SAFE and NON-INCENDIVE SENSORS - Refer to the Intrinsically Safe and Non-Incendive Installation
Manuals for barrier installation information.
Output Type
Pin 1
Pin 2
Pin 3
Wide
Pin
Pin 1
Pin 2
Pin 3
Wide
Pin
mV & 4-Wire Voltage
+S
GND
+V
-S
-S
GND
+V
+S
3 Wire Voltage
+V
GND
S
N/C
S
GND
+V
N/C
4-20mA (2 wire loop powered)
+V
-V
N/C
N/C
N/C
-V
+V
N/C
CSA Certified Sensors
Output Type
Pin 1
Pin 2
Pin 3
Wide
Pin
Pin 1
Pin 2
Pin 3
Wide
Pin
3 Wire Voltage
+V
GND
S
Case
S
GND
+V
Case
4-20mA (2 wire loop powered)
+V
GND
Case
N/C
N/C
GND
+V
Case
NOTICE FOR NON-INCENDIVE SENSORS INSTALLED IN [CLASS I, DIV 2, GROUPS A,B,C,D]
- Suitable for use in [Class I, Division 2, Groups A, B, C And D] Hazardous Locations, or Non Hazardous Locations only.
Explosion Hazard
- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations.
Explosion Hazard
- Substitution of any component may impair suitability for [Class I, Division 2]
NOTICE FOR INTRINSICALLY SAFE SENSORS Refer to the Intrinsically Safe Installation Manual for barrier installation information.
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 6
Bendix™
6 Pin MIL-C-26482 (REF. MS3113)
4 Pin MIL-C-26482 Series 1
(REF. MS3113)
AST Electrical Connection Option
”R”
”S”
Mates w/
PT06A-10-6S
PT06A-8-4S
AST Mating Connector Part #
A04235
N/A
NOTICE FOR INTRINSICALLY SAFE SENSORS - Refer to the Intrinsically Safe Installation Manual for barrier installation information
Output Type
Pin A
Pin B
Pin C
Pin D
Pin E
Pin F
(SS
only)
Pin A
Pin B
Pin C
Pin D
mV & 4-Wire Voltage
+V
+S
-S
GND
N/C
Case
+V
+S
-S
GND
3 Wire Voltage
+V
S
N/C
GND
N/C
Case
+V
S
N/C
GND
4-20mA (2 wire loop powered)
+V
GND
N/C
N/C
N/C
Case
+V
GND
N/C
N/C
+V
Voltage Supply
Option Code - For Special Wiring Requests
-V
4-20mA Electrical Ground / Signal [see
schematic]
Pin A
Pin B
Pin C
Pin D
Pin E
Pin F
(-SS only)
S
Voltage Output Signal
000
+V
+S
-S
GND
N/C
Case
GND
Voltage Electrical Ground
115
+S
-S
GND
+V
N/C
Case
Case
Case / Earth Ground
(Do not connect or tie the case ground to
the electrical ground)
164
+S
-S
+V
GND
N/C
Case
N/C
Not Connected
292
+V
GND
+S
-S
N/C
Case
Hirschmann, Bendix, Metri-Pack, Minifast and Molex are trademarks of their respective owners.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 7
Packard™ Metri-Pack
Delphi: Packard™ Metri-Pack 150
AST Electrical Connection Option
“F”
Mates w/
Packard™ Delphi 1206 5287
AST Mating Connector Part #
A04391
NOTICE FOR INTRINSICALLY SAFE SENSORS - Refer to the Intrinsically Safe Installation Manual for barrier installation information.
Output Type
Pin A
Pin B
Pin C
mV & 4-Wire Voltage
N/A
N/A
N/A
3 Wire Voltage
GND
+V
S
4-20mA (2 wire loop powered)
-V
+V
N/C
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected
Hirschmann, Bendix, Metri-Pack, Minifast and Molex are trademarks of their respective owners.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 8
Minifast™
M12x1
Minifast™
M12x1
AST Electrical Connection Option
”4”
”Y”
NOTICE FOR INTRINSICALLY SAFE and NON-INCENDIVE SENSORS - Refer to the Intrinsically Safe and Non-Incendive Installation
Manuals for barrier installation information.
Output Type
Code
Pin 1
Pin 2
Pin 3
Pin 4
Pin 1
Pin 2
Pin 3
Pin 4
mV & 4-Wire Voltage
000
-V
+S
+V
-S
+V
+S
-S
GND
3 Wire Voltage
000
-V
S
+V
Case
+V
N/C
GRD
S
4-20mA (2 wire loop powered)
000
-V
N/C
+V
Case
+V
N/C
-V
N/C
Output Type w/ Option Codes
Code
Pin 1
Pin 2
Pin 3
Pin 4
4-20mA (2 wire loop powered)
615
-V
+V
N/C
Case
3 Wire Voltage
607/617
S
+V
Case
-V
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected
Hirschmann, Bendix, Metri-Pack, Minifast and Molex are trademarks of their respective owners.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 9
DT04 DEUTSCH
CONNECTIONS
DEUTSCH: DT04 - 3 Pin
DEUTSCH: DT04 - 4 Pin
AST Electrical Connection Option
“K”
“Z”
Output Type
Pin A
Pin B
Pin C
Pin 1
Pin 2
Pin 3
Pin 4
mV & 4-Wire Voltage
-
-
-
+V
GND
+S
-S
3 Wire Voltage
+V
GND
S
+V
GND
S
N/C
4-20mA (2 wire loop powered)
+V
-V
N/C
+V
-V
N/C
N/C
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 10
Molex™
Molex™
AST Electrical Connection Option
“G”
Mates w/
Molex 22-01-3047 with pin 08-50-0114
Output Type
Pin 1
Pin 2
Pin 3
Pin 4
mV & 4-Wire Voltage
+V
+S
-S
GND
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected
Hirschmann, Bendix, Metri-Pack, Minifast and Molex are trademarks of their respective owners.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 11
Pressure & Temperature
Cable / Hookup
Wire Connections
(AST20PT & AST45PT)
Cable
AST Electrical Connection Option
‘”A, B, C, D, L, M, N, P, X*”
Gauge Wire
AST20PT- 24 AWG | AST45PT - 22 AWG
*see data sheet for special options
Output Type
Green
Black
Red
White
3 Wire Voltage
Temp (out)
-V (in)
+V (in)
Press (out)
4-20mA (2 wire loop powered)*
+Temp
-Press
+Press
-Temp
NOTICE FOR HAZARDOUS AREA SENSORS (AST46PT) - Refer to operating instructions for installation information.
* For units with loop-powered 4-20mA output, the pressure loop must be powered or the temperature output will not operate.
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 12
Pressure & Temp.
DIN
(AST20PT)
DIN 43650A 18.0mm
Mini-DIN 43650C 8.0mm
AST Electrical Connection
Option
“I”
“E”
Mates w/
931 970-100 [conduit] or equivalent
933 023-100
AST Mating Connector Part #
A09171
A01980
Output Type
Pin 1
Pin 2
Pin 3
Wide Pin
Pin 1
Pin 2
Pin 3
Wide Pin
3 Wire Voltage
+V(in)
-V (in)
Press
(out)
Temp
(out)
Press
(out)
-V (in)
+V (in)
Temp
(out)
4-20mA (2 wire loop powered)*
+Press
-Press
+Temp
-Temp
+Press
-Press
+Temp
-Temp
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected
* For units with loop-powered 4-20mA output, the pressure loop must be powered or the temperature output will not operate.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 13
Pressure & Temp.
Connections
(AST20PT)
Bendix™: 6 Pin MIL-C-26482 (REF. MS3113)
AST Electrical Connection Option
”R”
Mates w/
PT06A-10-6S
AST Mating Connector Part #
A04235
Output Type
Pin A
Pin B
Pin C
Pin D
Pin E
Pin F
3 Wire Voltage
+V(in)
Press
(out)
Temp
(out)
-V (in)
N/C
N/C
4-20mA (2 wire loop powered)*
+Press
-Press
+Temp
-Temp
N/C
N/C
M12x1: 4 Pin
DEUTSCH: DT04 - 4 Pin
AST Electrical
Connection Option
“Y”
“Z”
Pin 1
Pin 2
Pin 3
Pin 4
Pin 1
Pin 2
Pin 3
Pin 4
3 Wire Voltage
+V(in)
Temp(out)
-V(in)
Press(out)
+V(in)
-V(in)
Press(out)
Temp(out)
4-20mA (2 wire loop
powered)*
+Press
+Temp
-Press
-Temp
+Press
-Press
+Temp
-Temp
+V
Voltage Supply
-V
4-20mA Electrical Ground / Signal [see schematic]
S
Voltage Output Signal
GND
Voltage Electrical Ground
Case
Case / Earth Ground
(Do not connect or tie the case ground to the electrical ground)
N/C
Not Connected
* For units with loop-powered 4-20mA output, the pressure loop must be powered or the temperature output will not operate.

INSTALLATION | WIRING GUIDE
AST Pressure Sensors
TE CONNECTIVITY SENSORS /// INSTALLATION | WIRING GUIDE 12//2018
Page 14
NORTH AMERICA
Measurement Specialties, Inc.,
a TE Connectivity company
6801 Kaiser Drive
Fremont, CA 94555 USA
Tel +1 650 361 2222
Fax +1 650 361 2083
customercare.m[email protected]
te.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
TE Connectivity, and TE Connectivity (logo) are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse
of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
© 2018 TE Connectivity Ltd. family of companies All Rights Reserved.
Rev 01
12.17.2018
This manual suits for next models
1
Table of contents
Other TE Connectivity Accessories manuals
Popular Accessories manuals by other brands

Delta Electronics
Delta Electronics SR0224-12-DT-A0 Specifications

Kathrein
Kathrein ESD 44 quick start guide

ROSE DISPLAYS
ROSE DISPLAYS ANOGOTCHA SQUARE WITH WALL HANGERS manual

Gared Holdings
Gared Holdings SGRDSPT Series Installation and assembly instructions

LOBSTER
LOBSTER Phenom owner's manual

Cole Parmer
Cole Parmer Stuart SI60 instruction manual