Technibel K 60 D 070 Z User manual

kit RéGULatioN système
poUR pompe à chaLeUR iNveRteR
avec chaUFFaGe d’appoiNt éLectRiqUe
system coNtRoL kit
FoR iNveRteR heat pUmp
with eLectRic sUppoRt heateR
Mai 2013 10 11 566 - F.GB - 02
k 60 d 070 z
F
GB
Notice
d’iNstaLLatioN
iNstaLLatioN
iNstRUctioNs
(Etiquette signalétique)
(Data label)

2
""!
1-Purpose - Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2-Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3-Composition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4-Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5- nstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6-Connections on the heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
7-Starting - Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
# !#!
• Control kit designed to control heating installations with heat pump and electric support heater for residential purposes within
the scope of applications meant for TECHN BEL. See technical control file enclosed with kit.
This product, marked with the symbol, complies with the essential requirements of the following Directives:
- Low voltage No. 2006/95/EC.
- Electromagnetic Compatibility No. 2004/108/EC.
": This symbol mark and recycle system are applied only to EU countries and not applied to the countries in the other
area of the world.
Your product is designed and manufactured with high quality materials and components which can be recycled and reused.
At end of livetime, it should be eliminated separately from your household waste.
Please dispose of this equipment at your local community waste collection / recycling centre.
n the European Union there are separate collection systems for used electrical and electronic products.
Please help us to conserve the environment we live in!
#"!
389'11'9/43)422/88/43/3-'3*2'/39+3'3)+4,9./80/92:89(+5+7,472+*(=6:'1/,/+*'3*':9.47/8+*5+78433+1/3
'))47*'3)+</9.):77+3989'3*'7*8'3*7+)4-3/>+*97'*+57')9/)+8
+,47+*4/3-'3=<470439.+/389'11'9/432'0+8:7+/9/88</9).+*4,,'3*'1154<+78:551/+814)0+*4:9
""
• Consult the manuals of the system's various components:
- heat pump,
- control kit,
- 2 zones module, if any,
- DHW preparation tank, if any,
as well as the technical control file supplied with the kit.
+,47++').89'79:545+7'9/432'0+8:7+9.'99.+/9/85745+71=)43,/-:7+*,479.+'551/)'9/43
#"

3
!"
• The kit includes:
- A control box to be installed in the comfort zone (see
paragraph 5.1).
- An outside temperature sensor unit placed on the facade
of the building (see paragraph 5.2).
"
• The kit is designed allow complete installation control from the parameterable control unit.
• The orders given by the control unit are transmitted (via a two-wire communication line (BUS)) to installation elements.
• The heat pump and its electric support heater are controlled according to a setpoint resulting from the water temperature
calculated according to a water law (according to the outside temperature). Priority is given to thermodynamic heating.
• See operating details in the technical control file supplied with this kit.
•".+8=89+2)4397410/9& is appropriate for standard applications using heat pump with +1+)97/)8:55479.+'9+7:
•439741:3/9:
- Plastic wall-mounted control unit.
- Dimensions: height = 128 mm
width = 86 mm
depth = 34 mm
- Colour: White
- Class lll
- P 30
•:98/*+9+25+7'9:7+8+3847
- nstalled in a box with cable gland.
49+:
This sensor must be installed in a
location that is sheltered from
inclement weather. See details in
paragraph 5.2.
K60D070Z
"!
& &
- 1 Floor Zone.
- 2 Floor Zones.
- 1 Terminal Units Zone.
- 1 Radiators Zone.
- 2 Mixed Zones, Floor + Terminal Units.
- 2 Mixed Zones, Floor + Radiators.
- 1 Floor Zone with Domestic Hot Water preparation.
- 1 Radiators Zone with Domestic Hot Water preparation.

4
• The electrical conduits must be fixed.
• Pass the cables through the glands at the rear of the heat pump.
• The connection cables are not supplied.
':9/43
To avoid problems related to electromagnetic disturbances, do not route these cables near power cables. '79/):1'7
'99+39/438.4:1*(+5'/*949.+$5/149</7+
"!""#
" #"!""
• As the control unit is equipped with a temperature sensor, it must
be installed in a location that is representative of the temperature
of the comfort zone.
• Wall mounting: the unit must not be installed in corners, on
shelves or behind curtains, near sources or heat or directly
exposed to sunlight. The unit should be installed approximately
1.5 m above the floor.
• Open the unit by removing the lower screw and secure the base
to the wall (mounting holes, item ).
• Open the protective cover (screw ) and connect the BUS link to
the control board (see paragraph 6).
• Fit the control unit back on its base.
!"""#"!" "# !!
• This sensor must be located outside in a location that is
representative of the temperature to be measured (on a wall
facing North / North-west) and located away from parasitic
heat sources (chimney, thermal bridge, etc..) and sheltered
from inclement weather (under a roof overhand, for
example).
• Connection as per paragraph 6.
1
2
Base
+'7;/+<
!""
Mini 20 cm
1.50 m
Control unit
/3/)2

5
C
D
B
B
F
E
439741:3/9
With built-in ambient temperature sensor.
To be installed in zone 1.
Load
shedding
(if any)
Outside air
temperature
nstallation
water outlet
temperature
nstallation
water return
temperature
Control by pilot wire for 2nd zone (if any) with electric convectors.
Application: 1 FLOOR ZONE or
1 TERM NAL UN T ZONE or 1 RAD ATORS ZONE.
ECO signal to remote controls.
For the terminal unit zone.
Application: 1 TERM NAL UN T ZONE or 2 M XED ZONES.
BUS connection:
• towards M2Z 2 zones module for application: 2 FLOOR ZONES or 2 M XED ZONES.
• towards DHW preparation tank for application: 1 RAD ATORS ZONE W TH DHW.
1 FLOOR ZONE W TH DHW.
Possible
connections to be
made depending on
the applications
System board
Control board
Power board
422:3/)'9/431/3+#!
- 2-conductor shielded cable, minimum size 1 mm2with grounded shielding on heat pump side (*).
-"49'1 length of the BUS connection: 40 meters (control unit connections + 2-zone module, if any or DHW preparation
kit, if any ).
- To be connected to the () and () terminals if terminal strip.
(*) Refer to the ground shielding principle in paragraph 6.4.
:98/*+9+25+7'9:7+8+3847
- 2-conductor cable, min. size 0.5 mm2.
- Maximum length 25 meters.
- To be connected to the (!) and (!) terminals if terminal strip.
-49+:
This sensor must be located outside in a location that is representative of the temperature to be measured (on a wall facing
North / North-west) and located away from parasitic heat sources (chimney, thermal bridge, etc..) and sheltered from
inclement weather (under a roof overhand, for example)
. See paragraph 5.2.
1+)97/)8:55479.+'9+714'*8.+**/3-8/-3'1/,'3=
- Two possibilities:
1) By a "remote info" signal coming from the electrical utility meter: 1 twisted pair (6/10) cable with shielding (shielding
grounded on heat pump side).
2) By a good quality, potential-free external contact.
- Contact closed = load shedding of the electric support heater.
- 2-conductor cable, min. size 0.5mm2.
- Maximum length 25 meters.
-To be connected to the system board
8/-3'1,477+249+)4397418/,'3=
- n order to send reduced mode orders ()4 or 89'3*(=) to the terminal unit remote control units in the case of
applications such as 1 terminal unit zone or 2 mixed zones.
- n the form of a potential-free contact which can used in VLV (Very Low Voltage), 2A max.
-To be connected to the system board .
49+
The contact can control up to 10 () or () type controls.
Consult the terminal unit and remote control documentation to connect this contact.

6
/149</7+,47+1+)97/))43;+)9478/,'3=
- The pilot wire sends shut-down, "'39/,7++>+" (long term absence) or ")4342=" mode instructions to the electric
convectors in zone 2, and possibly in the case of 1 floor zone or 1 terminal unit zone applications.
Convector control (not supplied) must be adapted to receive this type of signal (standard G FAM 4).
Consult the manual of the electric convectors.
- 230 VAC signal from the system board .
- 1.5 mm2single-pole cable adapted for the operating voltage.
- Max. number of convectors controlled by the pilot wire: 20.
-To be connected to the system board .
49+
The electrical power supplied to the convectors must be the same as that of the heat pump.
"#"
- Route the pilot wire (230 V) separately from the other control connections.
12
CN1
230V
CN2 CN3 CN4
CN8 CN7 CN6 CN5
3
54321 4321 45321 321
NUFP R1 R2 R3 C E1 E2 T+
H1A1 C A2 C4 321S1 C S2 C S3 A3 H2 H3
T- D1 D2 +-
1234 1234 1234
E D
B
B
A1
(*)
F
C
21
XA
Pilot wire
Electric
convectors
(if any)
ECO signal
(if any)
Electrical
utility meter
Load shedding
(if any)
Control unit
BUS connection to 2-zone
module (if any) or DHW
tank (if any)
Or
Outside
temperature
sensor
!=89+2
(4'7*
Maintenance
keypad / display unit
(See paragraph 6.3)
Power supply
(*) Jumper (included on the terminal strip) for
switching from 4 kW electric support
heater (factory wired) to 6 kW.

7
"%!%#""
• A specific keypad / display unit can be connected for maintenance and
troubleshooting operations. See maintenance manual.
':9/43:
This keypad / display unit must not be used for the installation's normal
operation.
#"!
• To prevent problems resulting from electromagnetic interference, control cables must not be routed near 230 VAC cables.
'79/):1'7'99+39/438.4:1*(+5'/*949.+$5/149</7+
• Electrical connection conduits must be fixed.
#""#!
• Route the cables through the cable glands located at the back of the unit.
• Use the cable clamps mounted on the lower edge of the electrical panel
to secure the cables.
• Ground the shielding of the communication line (BUS) cable with the
metal clamp secured to the box panel.
R1 R2
"+72/3'1
Black
White
Cable clamp
Shielding
Metal clamp
Box panel
!" ""
• Refer to the heat pump installation instructions.

F
GB
./,1"(# *7)(,. 0(,+",+/0 +0$+,/-.,#1(0/-$12$+080.$*,#(%(7// +/-.7 2(/
1$0,,1.-,)("5,%",+0(+1,1/#$2$),-*$+0,1.-.,#1"0/ .$)( !)$0,*,#(%(" 0(,+3(0',10+,0("$
,10$#7- .0$*$+0 )$
$5.($14
6 $#$4
7) 4
$) 4
,1.&$+.$//$
Table of contents
Other Technibel Control Unit manuals
Popular Control Unit manuals by other brands

GEM
GEM 762 Installation, operating and maintenance instructions

Baker Hughes
Baker Hughes Masoneilan DSH Series instruction manual

Keba
Keba D3-DA 3 Series Project engineering manual

Unex
Unex SOM-352 Series quick start guide

HIMA
HIMA HIMatrix F60 Engineering manual

Lenze
Lenze ECS series operating instructions