are approximate and are
experience. Windload of a
t upon the style of type
of tent. The structural integrity of the tent may exceed the soil's holding capacity even at wind loads of
30 to 50 mph.
Frame tents require approximately 1000 to 2000 lbs of holding power per anchor locaon (dependent on
the size and style of the tent). For safety of all occupants, evacuaon is recommended if weather
becomes severe.
Severe storms have micro bursts of wind that may be recorded far in excess of the storm's highest
winds. The installer is responsible for properly securing the temporary structure (tent). Soil condions
will vary and the wind ind
load capabilies.
he holding power will
decrease and alternate anchoring methods are required.
Tent Size Footage
Anchor
Power Safety
Factor
Anchor
Locaons
Holding Power
Anchor Locaon
10' x 20' 200 1,920 1.5 6 320*
9
X-SERIES | 10x20
Note: The tent must be anchored properly for safe installaon. Additonal guys and stakes
may be required depending on soil and/or wind condions. Refer to the IFAI Procedural
Handbook for Safe Installaon and Maintenance of Tentage for calculang the proper
anchoring capacity for soil and or ground condions. Always follow manufacturer's recom-
mended anchoring techniques.
Guy Data:
1" Polyester Web - 3600 # rang*
*ASSUMES:
1. Surface: Compacted soil
2. Standard pull-out rate 800 lb/sq .
36" Stake driven within 6" from the
top of the ground straight down or
a maximum 10 degree angle
10'
7'
5'
10'
10'
7'
5'
10'
20'