EU Directive2014/53/ECcompliantRoHSEU Directive2011/65/ECEU Directive2012/19/EUGo to:www.tm-readers.comto view or download datasheetsto our series of readersOSDP readerDEFAULT SETTINGS:BAUD RATE9600for additional BAUD RATE & ADDRESS settingssee:OSDP CONFIGURATION GUIDEforRX SERIES of READERS100-02836
i
ADDRESS0for additional information see:OC1 INSTALLATION GUIDE100-02776
12109
OC1 OSDPCONVERTEROC1 OSDP converter to be located adjacent to your access control panel in a SECURE area.
existingWIEGANDaccesscontrol panel
LED OPERATION1.No communication withreader - LED flash RED 1/sec.2.Communication with readerNOT using AES secure -LED shows steady YELLOW.3.Communication with readerand IS using AES secure -LED shows steady BLUE.IMPORTANTFit 120 ohms resistor(supplied) to TERMINAL connections#9 and #10 as shown.- 1- 2- 3- 4- 5- 6- 7- 80V+Vdc INDATA1/CLKDATA0/DATAGREENREDBuzzerTMPR 4 -RS-485+ 3 -RS-485- 2 -+Vdc OUT 1 -0V
OC1 OSDPCONVERTERSecureRecommended cable for OSDPBELDEN 9502 (or equiv min 24 AWG).Recommended cableWiegandBELDEN 9538 (or equiv min 24 AWG).
12109IMPORTANTFit 120 ohms resistor(supplied) to TERMINAL connections#9 and #10 as shown.
OSDPaccesscontrol panel
PIN OUT (OSDP reader connection) 1- 0VSupply voltage ground 2-+VdcSupply voltage (+10Vdc to + 16Vdc) 3-not used 4-not used 5-not used 6-not used 7-not used 8-not used 9-RS-485 -RS-485 Bus10 -RS-485 +RS-485 BusSecureRecommended cable for OSDPBELDEN 9502 (or equiv min 24 AWG).Aconnection OSDP reader to OSDP CONTROL PANELBconnection OSDP reader via OC1 to WIEGAND CONTROL PANEL