manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. THOMSON
  6. •
  7. Controllers
  8. •
  9. THOMSON Generator Set Annunciator EAP 110 User manual

THOMSON Generator Set Annunciator EAP 110 User manual

This manual suits for next models

1

Other THOMSON Controllers manuals

THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS... User manual

THOMSON

THOMSON MEC 310#GENSET CONTROLLER OPTION J-CANBUS... User manual

THOMSON WhisperTrak User manual

THOMSON

THOMSON WhisperTrak User manual

THOMSON WhisperTrak Series User manual

THOMSON

THOMSON WhisperTrak Series User manual

THOMSON Electrak MD Series User manual

THOMSON

THOMSON Electrak MD Series User manual

THOMSON TSC 800 - V2.1 User manual

THOMSON

THOMSON TSC 800 - V2.1 User manual

THOMSON Electrak 1 Series User manual

THOMSON

THOMSON Electrak 1 Series User manual

THOMSON TSC 7320 Service manual

THOMSON

THOMSON TSC 7320 Service manual

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... Supplement

THOMSON

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... Supplement

THOMSON TSC 80E - V2.2 User manual

THOMSON

THOMSON TSC 80E - V2.2 User manual

THOMSON MEC 310 - WITH OPTION A AUTOMATIC MAINS... User manual

THOMSON

THOMSON MEC 310 - WITH OPTION A AUTOMATIC MAINS... User manual

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... User manual

THOMSON

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... User manual

THOMSON MK68590 User manual

THOMSON

THOMSON MK68590 User manual

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... Supplement

THOMSON

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... Supplement

THOMSON ECT Series Manual

THOMSON

THOMSON ECT Series Manual

THOMSON TSC 80 - V2.1 User manual

THOMSON

THOMSON TSC 80 - V2.1 User manual

THOMSON HD 100 User manual

THOMSON

THOMSON HD 100 User manual

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... Supplement

THOMSON

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... Supplement

THOMSON MEC 20 - V1.82 User manual

THOMSON

THOMSON MEC 20 - V1.82 User manual

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... User manual

THOMSON

THOMSON MEC 310 - APLLICATION NOTES EXTERNAL I-O... User manual

THOMSON EAP 110 Manual

THOMSON

THOMSON EAP 110 Manual

THOMSON TSC 80E - V2.1 User manual

THOMSON

THOMSON TSC 80E - V2.1 User manual

THOMSON MEC 320 User manual

THOMSON

THOMSON MEC 320 User manual

THOMSON TSC 900 Service manual

THOMSON

THOMSON TSC 900 Service manual

THOMSON TSC 80 - V2.2 User manual

THOMSON

THOMSON TSC 80 - V2.2 User manual

Popular Controllers manuals by other brands

Digiplex DGP-848 Programming guide

Digiplex

Digiplex DGP-848 Programming guide

YASKAWA SGM series user manual

YASKAWA

YASKAWA SGM series user manual

Sinope Calypso RM3500ZB installation guide

Sinope

Sinope Calypso RM3500ZB installation guide

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS sv-ip5a user manual

LSIS

LSIS sv-ip5a user manual

Airflow Uno hab Installation and operating instructions

Airflow

Airflow Uno hab Installation and operating instructions

ABB ACS580-01 drives Hardware manual

ABB

ABB ACS580-01 drives Hardware manual

Panasonic GM1 Series Reference manual

Panasonic

Panasonic GM1 Series Reference manual

Emerson SW93 owner's manual

Emerson

Emerson SW93 owner's manual

AutoAqua Smart ATO micro SATO-120P manual

AutoAqua

AutoAqua Smart ATO micro SATO-120P manual

Panasonic FP? Positioning Unit RTEX Technical manual

Panasonic

Panasonic FP? Positioning Unit RTEX Technical manual

Alpha IP MIOB 21001 manual

Alpha IP

Alpha IP MIOB 21001 manual

Siemens OpenAir GMA 1 Series Mounting instructions

Siemens

Siemens OpenAir GMA 1 Series Mounting instructions

Surecom SR-629 user manual

Surecom

Surecom SR-629 user manual

Regulus SRS1 T Installation and operation manual

Regulus

Regulus SRS1 T Installation and operation manual

3M MicroTouch EX113 reference guide

3M

3M MicroTouch EX113 reference guide

KUHN TKS user manual

KUHN

KUHN TKS user manual

S&C PMH Instructions for operation

S&C

S&C PMH Instructions for operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

THOMSON TECHNOLOGY INC. • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1
TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: [email protected] • www.thomsontechnology.com
ISO 9001-2000
®
02 • 07 • 01
GENERATOR SET ANNUNCIATOR
Model EAP 110
DESCRIPTION
•20 Light annunciator meets or
exceeds requirements of NFPA 110,
NFPA 99 & CSA 282-00 building code
standards for Emergency Standby
Generator systems
•RS 422 Data Communication capability
saves installation time & reduces costs
•Programmable annunciation & labeling
allows excellent flexibility for different
applications
•Automatic “ringback” & flashing
annunciator lights provides excellent
status indication of existing & incoming
fault conditions
•4fault annunciation circuits can be
activated from external hardwired
contacts for added system capability
•Multiple EAP 110 Annunciators can be
easily interconnected to provide up to 40
remote annunciation lights from a single
MEC 20 engine controller
The EAP 110 annunciator is designed for remote fault
annunciation of emergency standby generator sets
utilizing Thomson Technology MEC 2 & MEC 20 Engine
Controllers. The advanced design uses a RS 422
communication data link to provide the control &
monitoring signals between the engine controller and
remote annunciator. The communication link allows a
simple, cost effective system installation at any building
site. Up to 20 individual fault conditions are remotely
monitored utilizing both visual LED lights & audible
alarm annunciation. Lamp test and alarm horn silence
pushbuttons are provided. Each fault is individually
programmable for audible horn operation and alarm
labels are field configurable. Operation logic includes a
“auto-ringback” feature to annunciate subsequent alarm
conditions. For applications requiring additional alarm
annunciation from remote sensing contacts, the EAP 110
can accept up to 4 hardwired contact inputs dependant
upon the alarm configuration. The EAP 110 is DC powered
typically from a 12 or 24V engine starting battery. Two
EAP 110 annunciators can be interconnected together via
the communication link to allow up to 40 remote
annunciator points from a single MEC 20 engine controller
(consult Thomson Technology for further details). The
standard features of the EAP 110 meet and exceed all
requirements of NFPA 110, NFPA 99 & CSA 282-00
building code standards for Emergency Standby
Generator systems.
THOMSON TECHNOLOGY INC. • 9087A - 198th STREET, LANGLEY, BC CANADA V1M 3B1
TELEPHONE: (604) 888-0110 • FAX: (604) 888-3381 • E-MAIL: [email protected] • www.thomsontechnology.com
SUPPLY VOLTAGE 12V or 24V nominal (±20%), negative ground
SUPPLY CURRENT 100 ma (maximum), (±20%)
COMMUNICATION PORT RS 422, 4.8 KBaud, Thomson Technology T-Net Protocol
to MEC 2/MEC 20 8 conductor #22 AWG (min) Shielded/
Twisted cable (1000 ft Max), Plug-in RJ45 Connector
DIGITAL CONTACT INPUT Close to DC Negative
TEMPERATURE RANGE -40°C to +50°C
ENVIRONMENTAL Faceplate NEMA 12, Rear Enclosure NEMA 1
DIMENSIONS 6.0” W x 6.0” H x 3.0” D
Flush mount adapter option (7.0” w x 7.0” H)
MOUNTING Surface Mount (Standard), Flush-mount (Optional) Rear
Enclosure conduit box c/w Qty 8 1/2” knockouts
NOTE: Specifications subject to change without notice.
CL057 REV 0 02/07/01
SPECIFICATIONS
ORDERING INFORMATION
The EAP 110 may be ordered separately or in conjunction with unit mount control panels or engine controllers.
When ordering for use with existing MEC 2/MEC 20 engine controller applications in the field, contact Thomson
Technology for additional information regarding software/hardware compatibility.
The EAP 110 is supplied from the factory with standard alarm labeling for MEC 2* or MEC 20* engine controllers which
are applied to meet NFPA 110 Level 1/NFPA 99 or CSA 282 alarm requirements. The standard EAP 110 can be labeled and
programmed for alternate alarm configurations (consult Thomson Technology for further information). When specified, the
optional flush mount adapter plate is supplied loose with the standard Annunciator for field installation.
BASIC MODEL
MOUNTING
S=SURFACE(Standard)
F=FLUSH(Optional)
EXAMPLE:
EXTERNAL CONNECTIONS
+
OO
-
OOOOOO
Ext1 Ext2 Ext3 Ext4 B+ B- B+ B-
Communication
Port
1000' maximum cable length
No
Connection
J7
Expansion
Port
GRD
J6
MEC 2/20
Engine
Controller
Communication
Cable**
12-24V Engine
Cranking Battery
External Alarm
Sensing Contacts
(optional use
as required)
** 8 conductor Shielded Twisted Cable c/w RJ45 connectors.
EAP 110
Annunciator
J1
EAP 110 – S
*Note: For MEC 2 / MEC 20 details refer to separate brochures.