manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TIME LED
  6. •
  7. Lighting Equipment
  8. •
  9. TIME LED 793503 User manual

TIME LED 793503 User manual

Full Technical specification available upon request. Contact [email protected]o.uk for PDF.
Guardian Surface Mounted
5W Emergency Downlight
Cleaning:
• Do not use any chemical or abrasive cleaners.
• Clean product with only a soft dry cloth.
• Clean product at regular intervals.
Warning:
• This product is not a toy and contains small parts.
• This product is unsuitable for installation in or near coastal and marine environments.
Warranty:
This product is warranted to be free of defects in materials, design and workmanship for 3 years from the date
of purchase (conditions apply, please see TIME LED website for further details). If a suspected fault should
develop in this time, please contact us via the address on the front.
Recycling Advice:
Waste Electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.
Installation and Operating Instructions
INS-793503-V1
Package includes:
1 x Guardian Surface Mounted 5W Emergency Downlight
1 x Manual
IP20
3 YEARS
WARRANTY
Guardian Surface Mounted 5W Emergency Downlight
Read and follow instructions before operating your light.
Save this manual for future reference.
TIME LED is part of Pitacs Limited. For customer support contact:
Bradbourne Point, Bradbourne Drive, Tilbrook, Milton Keynes, Buckinghamshire MK7 8AT
T: +44 (0)1908 271155 F: +44 (0)1908 640017 E: info@timeled.co.uk W: www.timeled.co.uk
Safety:
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and
 currentBuildingRegulations.Ifinanydoubt,consultaqualiedelectrician.
• Isolate mains prior to installation or maintenance.
•Checkthetotalloadonthecircuit(includingwhenthisluminaireistted)doesnotexceedtheratingofthecircuit
cable, fuse or circuit breaker.
• This product is IP20 rated and suitable for interior installations only.
•TheLEDsttedinthisproductarenon-replaceable.
• This product is non-dimmable.
5W
015 015
25,000
HOURS
LIFESPAN
Replacement:
The battery is non-replaceable, when it no longer meets the rated duration of operation after the
corresponding recharge period, the whole luminaire needs to be replaced.
The light source contained in this luminaire must only be replaced by the manufacturer.
Iftheexiblecableofthisluminaireisdamaged,thewholeluminaireneedstobereplacedinorderto
avoid a hazard.
Product Code 793503
Size (mm) 130 x 39
Watts 5W
Lumens 250lm
IP Rating IP20
Beam Angle 140°
Dimmable No
Lifespan 25,000 Hours
Material PC + Aluminium
Net Weight 0.33kg
Voltage 220-240v
Input Frequency 50/60Hz
Current (A) 30mA
Colour Temp 6500k Daylight
Energy Rating A
Warranty 3 Years
Instructions for new installations:
1) Open the shell (See Fig.1)
2) Selecttheappropriatexingpointsasrequired,removetheknockoutandpullthepowercordthrough.
3) Fix the base to the mounting surface with screws and wall plugs. (See Fig.2)
4) Connectthepowercordtothedesignatedpositionasshowninthegure.Ifthecordisconnectedfrom
the side, insert the cord into the lamp body through the side hole.
5) Select whether to connect continuous short wiring according to needs. (See Fig.3)
6) Check the inside of the lamp for any abnormalities before replacing the shell. Pay attention to the
direction of the shell to ensure it is replaced at correct orientation. (See Fig.4)
7) Power-ontest,pleaserefertoTesting(seeFig.5)forspecicoperation.
Testing:
The emergency lighting must be inspected and tested regularly in accordance with local codes of practice.
This product has both a manual and a self-test function.
Note:
Forsafetyreasonstestsshouldbecarriedoutduringdaylighthoursbyaqualiedperson.
The test results should be recorded in accordance with current regulations.
• Flashing Green indicator – Product is in charging status
• Solid Green indicator - Product is fully charged status
• Solid Orange indicator - Product is in Monthly test
• Flashing Orange indicator - Product is in Annual test
• Sold / Flashing Red indicator- Product fault/Battery charge low
Monthly Auto-test:
When the product has been on charge for 30 days (±2 days), it will automatically enter monthly test mode, the
indicator will change to solid orange and the lamp will illuminate. The product is now in monthly test mode.
After 30 seconds the product will return to normal AC power, the lamp will turn off and the indicator will
changetoeithersolidgreen(FullyCharged),orashinggreen(Charging),bothgreenindicatorsconrmthe
product has passed its test. If a Fault is detected the indicator will turn to RED.
Annual Auto-test:
When the product has been on charge for 360 days (±2 days), it will automatically enter annual test mode, the
indicatorwillchangetoashingorangeandthelampwillilluminate.Theproductisnowinannualtestmode.
After 3 hours the product will return to normal AC power, the lamp will turn off and the indicator will change
toeithersolidgreen(FullyCharged),orashinggreen(Charging),bothgreenindicatorsconrmtheproduct
has passed its test. If a Fault is detected the indicator will turn to RED.
Manual Monthly test:
Press the test button twice, the lamp will turn on and the indicator will change to solid orange and the lamp
will illuminate. The product is now in monthly test mode. After 30 seconds the product will return to normal
ACpower,thelampwillturnoffandtheindicatorwillchangetoeithersolidgreen(FullyCharged),orashing
green(Charging),bothgreenindicatorsconrmtheproducthaspasseditstest.IfaFaultisdetectedthe
indicator will turn to RED.
Manual Annual test:
Pressthetestbuttonthreetimes,theindicatorwillchangetoashingorangeandthelampwillilluminate.The
product is now in annual test mode. After 3 hours the product will return to normal AC power, the lamp will
turnoffandtheindicatorwillchangetoeithersolidgreen(FullyCharged),orashinggreen(Charging),both
greenindicatorsconrmtheproducthaspasseditstest.IfaFaultisdetectedtheindicatorwillturntoRED.
Emergency Lamp Shutdown:
Under emergency conditions, the luminaire can be turned off by pressing the test switch for 3-5 seconds.
Fig.1
Fig.5
Fig.3
Fig.2
Fig.4

Other TIME LED Lighting Equipment manuals

TIME LED 781050 User manual

TIME LED

TIME LED 781050 User manual

TIME LED Guardian 5W Emergency Bulkhead User manual

TIME LED

TIME LED Guardian 5W Emergency Bulkhead User manual

TIME LED Elements Storm SITE110 Batten User manual

TIME LED

TIME LED Elements Storm SITE110 Batten User manual

TIME LED Elements User manual

TIME LED

TIME LED Elements User manual

TIME LED 769157 User manual

TIME LED

TIME LED 769157 User manual

TIME LED 781272 User manual

TIME LED

TIME LED 781272 User manual

TIME LED 780930 User manual

TIME LED

TIME LED 780930 User manual

TIME LED Prestige Pro User manual

TIME LED

TIME LED Prestige Pro User manual

TIME LED GU10 User manual

TIME LED

TIME LED GU10 User manual

TIME LED 781463 User manual

TIME LED

TIME LED 781463 User manual

TIME LED 781081 User manual

TIME LED

TIME LED 781081 User manual

TIME LED Stellar 769591 User manual

TIME LED

TIME LED Stellar 769591 User manual

TIME LED 300967 User manual

TIME LED

TIME LED 300967 User manual

TIME LED 781043 User manual

TIME LED

TIME LED 781043 User manual

TIME LED 780688 User manual

TIME LED

TIME LED 780688 User manual

Popular Lighting Equipment manuals by other brands

Halo seleCCTable LT4 instruction sheet

Halo

Halo seleCCTable LT4 instruction sheet

Oase Fountain Ring LED Set operating instructions

Oase

Oase Fountain Ring LED Set operating instructions

American DJ Jelly Fish User instructions

American DJ

American DJ Jelly Fish User instructions

Blueview NDF1005 quick start guide

Blueview

Blueview NDF1005 quick start guide

Factorylux BULKHEAD quick guide

Factorylux

Factorylux BULKHEAD quick guide

Fiilex Q1000 quick start guide

Fiilex

Fiilex Q1000 quick start guide

Ranger design 6092-42 installation guide

Ranger design

Ranger design 6092-42 installation guide

Sylvania ValueLED UFO High Bay installation guide

Sylvania

Sylvania ValueLED UFO High Bay installation guide

Uplus Lighting 200 LED RETRO user manual

Uplus Lighting

Uplus Lighting 200 LED RETRO user manual

Vision & Control LDLF60x600-G525/24V Instructions for use

Vision & Control

Vision & Control LDLF60x600-G525/24V Instructions for use

Martin MAC 250 Wash user manual

Martin

Martin MAC 250 Wash user manual

Laserworld Pro-6000 RGB user manual

Laserworld

Laserworld Pro-6000 RGB user manual

Martin Professional MiniMAC Wash user manual

Martin Professional

Martin Professional MiniMAC Wash user manual

Beninca STAR manual

Beninca

Beninca STAR manual

WULF MONOLUX manual

WULF

WULF MONOLUX manual

Elation SIXPAR 200 user manual

Elation

Elation SIXPAR 200 user manual

Elinchrom 250 Operation manual

Elinchrom

Elinchrom 250 Operation manual

U-Line H-7260 quick guide

U-Line

U-Line H-7260 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.