The TIME setting controls how long the unit remains illuminated following activation and
after all motion ceases.
(See diagram G. the time adjustment knob is indicated by the ‘Clock’ symbol).
The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time
(fully clockwise) is approx. 18 minutes. Set the control to the desired setting
between these limits.
The DUSK control determines the level of darkness required for the unit to start operating.
The setting is best achieved by the procedure below:
(See diagram G. the Dusk adjustment knob is indicated by the ‘Moon’ and ‘Sun’ symbols).
Set the DUSK control knob fully anti clockwise. Wait until darkness falls.
When the ambient light level reaches the level of darkness at which you wish the lamp to
become operative (i.e. at dusk) SLOWLY rotate the control in a clockwise direction until
a point is reached where the lamp illuminates. Leave the control set at this point.
At this position the unit should become operative at approximately the same level of darkness
each evening. Observe the operation of the unit. If the unit is starting to operate too early
(i.e. when it is quite light) adjust the control slightly anti-clockwise. If the unit starts to
operate too late (i.e. when it is very dark). Adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.
The LED's will scroll from left to right, day and night; indicating the unit is in Automatic
Mode. The LED's will extinguish when the PIR activates the light for as long as the lamp
is illuminated.
MASKING THE SENSOR LENS
To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens
using the masks provided in the accessory pack (see diagram H). For your information, the top
section of the lens covers long range detection, the bottom covers short range. Similarly the
left and right lens sections cover the left and right detection areas respectively.
MANUAL OVERRIDE MODE – SINGLE LED ILLUMINATED
The light can be switched on for longer time periods by use of the Manual Override Mode.
This can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker twice (OFF/ON, OFF/ON) within 2 seconds.
The unit will now illuminate continuously for the user defined time, between 1 – 8 hours,
or until the unit is switched back into auto mode. The ON time can be set by rotating the
centre adjustment knob as required (see diagram G). This time adjustment is factory set to
1 hour (Fully anti-clockwise is 1 hour, fully clockwise is 8 hours).
Note: If the light is still ON at dawn, before the set time expires, it will automatically switch OFF.
The Manual Override Mode can be set in the day time or at night time.
In the day time, the Manual Override mode is indicated by the permanent illumination
of a single red LED in the top of the sensor head.
At night time, no red LED will be visible.
To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker OFF/ON
once within 1 second. The unit will return to Auto Mode. This is indicated by the return of
the left to right scrolling LED's as described in Automatic Operation above.