Web: www.tinker-rasor.com E-mail: Info@tinker-rasor.com
Page 2of 6
P. O. BOX 1667 SAN BERNARDINO,CA 92402 TEL:(909) 890-0700 FAX:(909) 890-0736
PRODUCT INSTRUCTIONS
DESCRIPTION
The Model M/1 Holiday Detector is a highly sensitive device designed to locate holidays (pin holes,
voids, etc.) in thin film protective coatings of relatively high electrical resistance when such films
are applied to the surface of material of low electrical resistance. In these applications, such as
painted metal surfaces, the Model M/1 Holiday Detector will locate these points very accurately
with an audible and visual signal. This method of inspection of thin film is a non-destructive test
and will not injure the protective coating.
EQUIPMENT
The Model M/1 Holiday Detector consists of a portable battery powered electronic instrument, a
wand handle, sponge assembly (open cell sponge ships compressed, will expand with water), and
ground wire. The instrument is housed in a sturdy plastic case with provision for attachment of
optional (not included) headphones.
The detector is a “non-destructive wet sponge” type holiday detector. The basic electronic design
of the Model M/1 Holiday Detector is that of a very sensitive circuit which is energized by one 9v
battery. When current of 500 or 700 (+/- 10/%) micro-amperes flows in the circuit, an audible and
visual signal is actuated.
The test lead wire used in the ground wire can handle a minimum of 100 milliamps at 100 volts. If
replacement or additional wire is needed, make sure it meets these requirements. Up to 100’ length
of ground wire does not adversely affect the detectors operation, in most cases. If adding additional
ground wire, 14 AWG stranded or equivalent is recommended.
The exploring electrode is open-cell sponge material and is conductive when saturated with a
wetting solution. The sponge electrode is attached to the non-conductive wand handle by means
of the bolt with knob, plastic sponge holder and backing plate.
The wetting solution should consist of potable tap water and a wetting agent. The ratio of one (1)
ounce agent to one (1) gallon tap water is recommended. Tinker & Rasor WATER-WETTER©is a
non-sudsing wetting agent, available in 8 oz. bottles, factory direct or through stocking distributors.
The M/1 is powered by a replaceable 9v battery. The instrument is powered On by sliding the
On/Off switch at the top of the case. A Blue LED indicates power.
NOTE: on older M/1 units, a low running tone was used to indicate the instrument was
powered On.
The M/1 has belt loops on the back of the instrument so that it can be worn around the waist.
PRE-ELECTRICAL TEST PROCEDURES