TIS ADS-1D-1Z User manual

The ADS Dimmer is a Wi-Fi-enabled universal
dimmer module that is used to dim lights and can
connect to the Internet for remote control through
the TIS app. It includes 1 dry input that can be
linked to any push button wall switch to dim the
lights from the wall.
PRODUCT INFORMATION
TIS AIR ADS DIMMER
INSTALLATION MANUAL
Model: ADS-1D-1Z
DIMMER MODULE WITH WI-FI COMPATIBILITY
PRODUCT SPECIFICATIONS
Power supply
Input Voltage 110-230 VAC 50/60 Hz
Output Power 3W / 12V
Protection Built in Protection fuse
Current consumption 10-20 mA / 12 V DC
Output
Number of channels 1
Nominal voltage 110 / 230 V AC 50/60 Hz
Nominal current per channel
Lighting Incandescent Lamp 500 Watts
LED (dimmable) 300 Watts
CFL (dimmable) 300 Watts
TIS AIR WIFI Signal 2.4 GHz
Protocol Standard 802.11 b/g/n
Operating and display
elements
Digital inputs 1 dry inputs for control …
TIS AIR TIS Protocol messages and commands
PRG Button with LED Programming button and status LED.
Upgrading By WIFI Connection
Dimensions (Width × Length × Height) 50mm × 35mm × 50mm
Housing
Materials PC fire proof
Internal Parts color White
IP rating IP 50
BARCODE (UPC-A)
6 58921 79618 4

2
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
Mounting Location
Install in a dry, indoor area with a suitable
temperature and humidity range.
Electrical Wires
The recommended wire size for light
channels is 2.5mm, for the Line, Neutral,
and Load cables. The installer should
consider the total current consumption
when selecting the wires.
Warranty
There is a two-year warranty provided
by law. The hologram warranty seal and
product serial number are available on
each device.
Read Instructions
We recommend that you read this
Instruction Manual before installation.
Safety instructions
Electrical equipment should only be
installed and tted by electrically skilled
persons.
Failure to observe the instructions may
cause damage to the device and other
hazards.
These instructions are an integral part of
the product and must remain with the end
customer.
Programming
This device can be tested and
programmed manually. Advanced
programming requires knowledge of
the TIS Device Search software and
instruction in the TIS advanced training
courses.
Simple Installation
it ts on most junction box sizes or can be
located anywhere.

3
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
INSTALLATION STEPS
2Remove the switch cover. Unscrew and
pull the wall switch out. Take the wires
out of the load and line.
3Find a total of 3 wires.
1Turn off the power at the main circuit
breaker to turn off voltage supply to the
switch.
WARNING! HIGH VOLTAGE
Circuit Breaker
OFF

4
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
INSTALLATION STEPS
4Turn on the power at the main power
breaker, and carefully identify the live
wire using a voltage tester, and nd the
neutral wire.
Circuit Breaker
ON
5Turn off the main power breaker.
Circuit Breaker
OFF
6 Attach the neutral and live wires to the N &
L terminals, respectively.
7 Attach the load wire to the ⦻terminal.

5
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
INSTALLATION STEPS
9
8
Turn on the breaker. The module should
turn on accordingly.
Connect the 3 Dry inputs wires to the wall
switch or any 3rd party sensor.
Circuit Breaker
ON

6
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
SERVER LINKING
In order for a project to be fully linked to the TIS server, server conguration must be
enabled in just 1 product within that project.
If you have already done that with any other panel, just ignore these steps and proceed to
conguration steps.
To do the server linking, complete the following steps:
2On the module, press and hold the PRG
button for 6 seconds. The PRG LED will
start blinking.
1In the TIS App, go to Settings Connect
Server, and follow the steps by entering
your SSID password.
21
6”

7
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
SERVER LINKING
4Select your server option and 4-digit
password. Then, press Save.
3On the TIS app, press Search and wait
for a few seconds. The panel will link to
your Wi-Fi, and the PRG button will turn
blue.
21

8
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
21
1In the TIS App, go to the Settings AIR
Device Conguration, and follow the
steps by entering your SSID password.
2On the module, press and hold the PRG
button for 6 seconds. The PRG LED will
start blinking.
CONFIGURATION STEPS
3On the TIS app, press Search and wait
for a few seconds. The module will link
to your Wi-Fi, and the PRG LED will turn
blue.
6”

9
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
2
2
1
1
4 Select the room; then, select channel
names and icons.
5 Go to the congured room’s page and
start controlling.
ADS-1D-1Z ADS-1D-1Z
CONFIGURATION STEPS

10
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
PAIRING (MANUAL PROGRAMMING)
2 Go to any other wall panel and short
press on any lighting button.
3 Test by pressing on the wall panel’s
ON/OFF button. The module relay
should respond by turning ON and OFF
accordingly.
To pair the TIS ADS module with any TIS wall panel buttons, do the following:
CHANDELIER
00-00-00 IN 22
SPOTLIGHT
CEILING
WALL LIGHT
ROPE LIGHT
FLUORESCENT
CHANDELIER
00-00-00 IN 22
SPOTLIGHT
CEILING
WALL LIGHT
ROPE LIGHT
FLUORESCENT
1Short press on the PRG button ve times
in a row until the PRG LED starts to blink
every 2 seconds.
×5

11
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
USER OPERATION
Use your mobile app or smart wall
switches to control lights ON/OFF.
On wall switch, Long press for dimming,
short press for ON/OFF

12
INSTALLATION MANUAL
Model: ADS-1D-1Z
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
www.tiscontrol.com
TIS AIR ADS DIMMER
TROUBLESHOOTING
PRG button blinks purple
color rapidly
Reason: The panel address conicts with another
device in the TIS network. You need to press and
hold the PRG button for 6 seconds so that the
module can get a new address.
Device’s PRG LED is RED Reason: The device is not connected to Wi-Fi.
Device can’t link to Wi-Fi
router
Reason 1: The device is too far from the WiFi
router.
Reason 2: The SSID or password is not correct.
Reason 3: Some setting in the WIFI router is
preventing new devices from being added.
Other wall panels can’t pair
with the device
Reason 1: Other panel connections are not linked
to the same Wi-Fi network.
Reason 2: The manual programming function is
disabled in the device (default is enabled).
Other wall panels can’t
control the device channels
Reason 1: Other panel connections are not linked
to the same Wi-Fi network.
Reason 2: The programming address is wrong.
Table of contents
Other TIS Dimmer manuals
Popular Dimmer manuals by other brands

Berker
Berker 2819 Series Operation and assembly instructions

Maestro IR
Maestro IR CM-L300FQ1 user manual

Mi-Heat Heizsysteme
Mi-Heat Heizsysteme DRA1800 quick start guide

WiSilica
WiSilica lumos CONTROLS Omni TED quick start guide

ARC
ARC MWMR-250 manual

Acclaim Lighting
Acclaim Lighting AL-DIMMER-3F User instructions