manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Toshiba
  6. •
  7. Air Conditioner
  8. •
  9. Toshiba RAS-24SK Series User manual

Toshiba RAS-24SK Series User manual

This manual suits for next models

3

Other Toshiba Air Conditioner manuals

Toshiba RBC-AXU31C-E User manual

Toshiba

Toshiba RBC-AXU31C-E User manual

Toshiba MMY-MAP0806HT8(J)P User manual

Toshiba

Toshiba MMY-MAP0806HT8(J)P User manual

Toshiba RAS-10N3KV Series User manual

Toshiba

Toshiba RAS-10N3KV Series User manual

Toshiba RAS-B07 User manual

Toshiba

Toshiba RAS-B07 User manual

Toshiba MMD-AP0726HP-UL User manual

Toshiba

Toshiba MMD-AP0726HP-UL User manual

Toshiba RAS-B10N4KVRG-E1 User manual

Toshiba

Toshiba RAS-B10N4KVRG-E1 User manual

Toshiba RAS-18SKPX User manual

Toshiba

Toshiba RAS-18SKPX User manual

Toshiba RAS-B10GKVP-E User manual

Toshiba

Toshiba RAS-B10GKVP-E User manual

Toshiba RAC-18LH Mounting instructions

Toshiba

Toshiba RAC-18LH Mounting instructions

Toshiba Carrier TCB-AX21UL User manual

Toshiba

Toshiba Carrier TCB-AX21UL User manual

Toshiba RAS-4M23SAV-E User manual

Toshiba

Toshiba RAS-4M23SAV-E User manual

Toshiba RAV-SM122BTP-UL User manual

Toshiba

Toshiba RAV-SM122BTP-UL User manual

Toshiba RAS-10G2KVP Series User manual

Toshiba

Toshiba RAS-10G2KVP Series User manual

Toshiba RAV-SM564UT-E User manual

Toshiba

Toshiba RAV-SM564UT-E User manual

Toshiba RAV-162BH-PE User manual

Toshiba

Toshiba RAV-162BH-PE User manual

Toshiba RAS-25G3KVSGB-ND User manual

Toshiba

Toshiba RAS-25G3KVSGB-ND User manual

Toshiba RAS-13SKV-E User manual

Toshiba

Toshiba RAS-13SKV-E User manual

Toshiba RAS-25N4KVRG-ND User manual

Toshiba

Toshiba RAS-25N4KVRG-ND User manual

Toshiba MiNi-SMMS MCY-MAP0401HT User manual

Toshiba

Toshiba MiNi-SMMS MCY-MAP0401HT User manual

Toshiba MMU-AP0071MH User manual

Toshiba

Toshiba MMU-AP0071MH User manual

Toshiba RBC-TWP50E2 User manual

Toshiba

Toshiba RBC-TWP50E2 User manual

Toshiba RAC-WK0611CRU User manual

Toshiba

Toshiba RAC-WK0611CRU User manual

Toshiba TCB-IFLN642TLE User manual

Toshiba

Toshiba TCB-IFLN642TLE User manual

Toshiba RAV-SP1104AT8-E1 User manual

Toshiba

Toshiba RAV-SP1104AT8-E1 User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OWNER’S MANUAL
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
RAS-18, 24SK Series
Outdoor unit
RAS-18, 24S Series
1110650149
WARNING
•Donotexposeyourbodydirectlytocoolairforalongtime.
•Donotinsertyourngeroranyarticleintotheairinlet/outlet.
•Whenanabnormality(burningsmell,etc.)occurs,stoptheairconditionerand
turnoffthecircuitbreaker.
•Installationmustberequestedfromthesupplyingretaildealershipor
professionalinstallationvendors.Installationrequiresspecialknowledgeand
skill.Ifcustomersinstallontheirown,itcanbeacauseofre,electricshock,
injuryorwaterleakage.
•Donotselectalocationforinstallationwhereammablegasmayleak.Ifthere
isanygasleakageoraccumulationaroundtheunit,itcanbeacauseofre.
•DonotturnON/OFFthecircuitbreakeroroperatebuttonswithawethand.
 Itmaybeacauseofelectricshock.
•Donotdisassemble,modifyorrelocatetheunitbyyourself.Itmaybecomethe
causeofre,electricshock,orwaterleakage.Forrepairorrelocation,please
requestservicefromthesupplyingretaildealershiporaToshibadealership.
•Donotselectalocationforinstallationwheretheremaybeexcessivewater
orhumidity,suchasabathroom.Deteriorationofinsulationmaybeacauseof
electricshockorre.
•Whenrelocatingorrepairingtheunit,pleasecontactthesupplyingretail
 dealership.Whenthereisakinkinthewiring,itmaybethecauseofelectric
 shockorre.
•Duringanerror(suchasaburningodor,notcooling,ornotwarming),stop
 operatingtheunitandturnoffthecircuitbreaker.Continuousoperationmaybe
 acauseofre,orelectricshock.Pleaserequestrepairorservicefromthe
supplyingretaildealershiporaToshibadealership.
•Earthworkshouldberequestedfromthesupplyingretaildealershipor
professionalvendors.Insufcientgroundingworkmaybethecauseofelectric
shock.Donotconnecttheearthwiretoagaspipe,waterpipe,lightning
conductor,ortelephoneearthwire.
•Iftheindoorunitpipingoutletisexposedduetorelocation,closetheopening.
 Touchinginternalelectricalpartsmaycauseinjuryorelectricshock.
•Donotinsertanymaterial(metal,paper,orwater,etc.)intotheairoutletor
airintakeopening.Fanmayberotatingathighspeedinsideortherearehigh
voltagesections,whichmaycauseaninjuryorelectricshock.
• Youmustuseaindependentpoweroutletforthepowersupply.Ifapoweroutlet
otherthantheindependentoutletisused,itmaycauseare.
•Whentheair-conditioningunitdoesnotcoolorwarm,theremaybealeakage
 ofrefrigerant.Pleaseconsultthesupplyingretaildealership.Therefrigerant
 usedintheair-conditioningunitissafe.Itwillnotleakundernormaloperating
conditionsbutifitleaksintotheroomandcontactsaheatsourcesuchasa
heater,orstove,itmaycauseaharmfulreaction.
•Whenwaterorotherforeignsubstancesentertheinternalparts,stopoperating
theunitimmediatelyandturnoffthecircuitbreaker.Operatingtheunit
continuouslymaycausereorelectricshock.Pleasecontactthesupplying
retaildealershipforrepair.
•Donotcleantheinsideoftheair-conditioningunityourself.Pleaserequest
 internalcleaningoftheair-conditioningunitfromthesupplyingretaildealership.
 Incorrectcleaningmaycausebreakageofresinpartsorinsulationdefectsof
electricalparts,causingwaterleakage,electricshockorre.
•Donotdamageormodifythepowercable.Donotconnectthecablemidway,
 oruseamultipleoutletextensioncordthatissharedbyotherdevices.Failure
todosomaycausere.
•Donotplaceheavyobjectsonthepowercable,exposeittoheat,orpullit.
 Todosomaycauseelectricalshockorre.
•Thisapplianceisnotintendedforusebypersons(includingchildren)with
reducedphysical,sensoryormentalcapabilities,orlackofexperienceand
knowledge,unlesstheyhavebeengivensupervisionorinstructionconcerning
useoftheappliancebyapersonresponsiblefortheirsafety.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththe
appliance.
PRECAUTIONS FOR SAFETY
1 HiPOWER(Green)
2 FILTER(Orange)
3 PURE(Blue)
4 TIMER(Yellow)
5 OPERATION(Green)
6 RESETbutton
INDOOR UNIT DISPLAY
1
HiPOWER FILTER PURE TIMER OPERATION
RESET
1 2 3
4 5
6
3
5
6
4
2
DANGER
•Donotinstall,repair,openorremovethecover.Itmayexposeyoutodangerous
voltages.Askthedealershiporthespecialisttodothis.
•Turningoffthepowersupplywillnotpreventpotentialelectricshock.
•Theapplianceshallbeinstalledinaccordancewithnationalwiringregulation.
•Meansfordisconnectionfromthesupplyhavingacontactseparationofatleast
3mminallpolesmustbeincorporatedinthexedwiring.
CAUTION
•Checkthatthecircuitbreakerisinstalledcorrectly.Ifthecircuitbreakerisnot
 properlyinstalled,itmaycauseanelectricshock.Tochecktheinstallation
method,pleasecontactthesupplyingretaildealershiportheprofessionalvendor
 whoinstalledtheunit.
•Whenusingtheunitinaclosedroom,oroperatingwithothercombustion
appliances,makesuretoopenawindowoccasionallyforventilation.Insufcient
 ventilationmaycausesuffocationduetoalackofoxygen.
•Avoidoperatingforlongperiodsinahighhumidityenvironment(over80%)such
 aswiththewindowsordoorsopen.Theremaybecondensationontheindoor
unitanddropletsmayfallontothefurniture.
•Whentheunitwon’tbeusedforalongtime,turnoffthemainswitchorthecircuit
 breaker.
•Itisrecommendedthatmaintenancebeperformedbyaspecialistwhentheunit
hasbeenoperatedforalongtime.
•Atleastonceayearcheckifthemountingtableoftheoutdoorunitisdamaged
ornot.Ifadamagedstateisignored,theunitmayfallorover-turn,causingan
injury.
•Standonasturdyladderwhenattaching/detachingthefrontpanel/airlter/air
cleaninglter.Failuretodosomaycauseafallorinjury.
•Donotstandontheoutdoorunitorplaceanythingontheunit.Itmaybethe
causeofinjuryduetofallingorover-turning.Anydamagetotheunitmaycause
anelectricshockorre.
•Donotusecombustionappliancesinthedirectowoftheairfromtheair-
conditioningunit.Poorcombustionofacombustionappliancemaycause
suffocation.
•Donotplaceanythingaroundtheoutdoorunitorallowfallenleavestoaccumulate
 aroundit.Iftherearefallenleaves,smallanimalscouldenterandcontact
internalelectricalparts,causingafailureorre.
•Donotplaceanimalsandplantsinplaceswherewindfromtheair-conditioning
unitowsdirectly.Itmayhaveanegativeinuenceontheanimalorplant.
•Ensurethatdrainedwaterisdischarged.Whenthedischargingwaterprocess
isnotsufcient,watermayleak,causingwaterdamagetofurniture.Tocheck
thattheinstallationmethodusediscorrect,pleasecontactthesupplyingretail
dealershiportheprofessionalvendorwhoinstalledtheunit.
•Donotplaceanycontainerssuchasavasecontaininguidontheunit.Itmight
causewatertoentertheunitanddeterioratetheelectricalinsulation,causing
anelectricshock.
•Donotuseforspecialapplicationssuchasstorageoffoodoranimals,orto
displayplants,precisiondevices,orartobjects.Donotuseonshipsorinother
vehicles.Itmaycauseafailureintheair-conditioningunit.Inaddition,itmay
damagetheseitems.
•Donotplaceotherelectricalappliancesorfurnitureundertheunit.Water
dropletsmightfall,causingdamageorfailure.
•Whencleaning,youmuststopoperatingtheunitandturnoffthecircuitbreaker.
Sincethefaninsidemayberotatingathighspeed,itmaycauseaninjury.
•Donotwashthemainair-conditioningunitwithwater.Itmaycauseanelectric
shock.
•Afterthefrontpanel/airlteriscleaned,wipeawayanywaterandallowtodry.
Ifwaterremains,itmaycauseanelectricshock.
•Oncethefrontpanelisremoved,donottouchthemetalpartsoftheunit.Itmay
causeaninjury.
•Donottouchtheairintakesectionorthealuminumnsoftheunit.Itmaycause
 injury.
•Whenyouhearthunderandtheremightbealightningstrike,stopoperatingthe
 unitanddisconnectthecircuitbreaker.Iflightningstrikes,itmaycauseafailure.
•Batteriesforremotecontrolunit:
- Shouldbeinsertedwithcorrectpolarity(+)and(-).
- Shouldnotberecharged.
-
Donotusebatteriesforwhichthe“Recommendedusageperiod”hasexpired.
- Donotkeepusedbatteriesinsidetheremotecontrolunit.
- Donotmixdifferenttypesofbatteries,ormixnewbatterieswitholdones.
- Donotdirectlysolderthebatteries.
-
Donotshort-circuit,disassemble,heat,orthrowbatteriesintoare.Ifbatteries
 arenotdisposedofcorrectly,theymayburstorbethecauseofuidleakage,
resultinginburnsorinjuries.Iftouchingtheuid,washthoroughlywithwater.If
ittouchesdevices,wipeofftoavoiddirectcontact.
- Donotplacewithinreachofsmallchildren.Ifabatteryisswallowed,consulta
doctorimmediately.
DRY OPERATION
1
Press
FIX
:Movethelouverinthe
desiredverticaldirection.
2
Press
SWING
:Swingtheair
automaticallyandpressagaintostop.
3
Forhorizontaldirection,adjustmanually.
PRECAUTIONS FOR SAFETY
AIR FLOW DIRECTION
3
Note:
• Donotmovethelouvermanuallybyothers.
• Thelouvermayautomationpositioningbysomeoperationmode.
ONE-TOUCH
5
Pressthe“ONE-TOUCH”buttonforfullyautomatedoperationthatiscustomized
tothetypicalconsumerpreferencesinyourregionoftheworld.Thecustomized
settingscontroltemperatureairowstrength,airowdirectionandothersettings
toprovideyoualternatecontactwith“ONE-TOUCH”ofthebutton.Ifyouprefer
other settings you can select from the many other operating functions of your
Toshibaunit.
 Press
ONE-TOUCH
:Starttheoperation.
AUTOMATIC OPERATION
6
Toautomaticallyselectcooling,heating,orfanonlyoperation
1.Press
MODE
:SelectA.
2.Press
TEMP
:Setthedesiredtemperature.
1.Press
MODE
:SelectCool ,Heat ,orFanonly .
2.Press
TEMP
:Setthedesiredtemperature.
 Cooling:Min.17oC,Heating:Max.30oC,FanOnly:Notemperatureindication
3.Press
FAN
:SelectAUTO,LOW ,LOW+ ,MED ,MED+ ,or
 HIGH .
8
Fordehumidication,amoderatecoolingperformanceiscontrolledautomatically.
 1.Press
MODE
:SelectDry .
 2.Press
TEMP
:Setthedesiredtemperature.
Hi-POWER OPERATION
AIR PURIFYING OPERATION
10
9
To automatically control room temperature and airow for faster cooling or
heatingoperation(exceptinDRYandFANONLYmode)
 Press
Hi-POWER
:Startandstoptheoperation.
Press
PURE
tostartandstopplasmaairpurierandairionizeroperation.
Theplasmaairpurierandairionizercanbeactivatedordeactivatedbypressing
thePUREbutton.Theairionizerstartsinconjunctionwithplasmaairpurier
operation.
Note: TheFILTERindicator(orange)turnsonafterPUREoperationisperformed
  forabout1000hours.
ECO OPERATION
11
Toautomaticallycontrolroomtosaveenergy(exceptinDRYandFANONLYmode)
Press
ECO
:Startandstoptheoperation.
Note:Coolingoperation;thesettemperaturewillincreaseautomatically1degree/
  hourfor2hours(maximum2degreesincrease).Forheatingoperationthe
  settemperaturewilldecrease.
REMOTE CONTROL
4
PREPARATION BEFORE USE
2COOLING / HEATING / FAN ONLY OPERATION
7
Preparing Filters
 1.Opentheairinletgrilleandremovetheairlters.
 2.Attachthelters.(seedetailintheaccessorysheet).
Loading Batteries
 1.Removethebatterycover.
 2.Insert2newbatteries(AAAtype)
  followingthe(+)and(–)positions.
Clock Setup
 1.PushCLOCK●bytipofthepencil.
  Iftimerindicationisashing,gotothenextstep2.
2.Press ON or OFF :adjustthetime.
 3.Press SET :Setthetime.
Remote Control Reset
 1.Removethebatteries.
 2.Press .
 3.Insertthebatteries.
AC L
TEMPORARY OPERATION
12
Incaseofthemisplacedordischargedremotecontrol
• PressingtheRESETbutton,theunitcanstartor
stopwithoutusingtheremotecontrol.
• OperationmodeissetonAUTOMATICoperation,
presettemperatureis24°Candfanoperationis
automaticspeed.
TIMER OPERATION
13
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Everyday Timer
Setting the ON Timer Setting the OFF Timer
1
2
Press SET :Setthetimer. Press SET :Setthetimer.
3
Press
CLR
:Cancelthetimer. Press
CLR
:Cancelthetimer.
• Duringtheeverydaytimerisactivating,botharrows( , )areindicated.
Note:
• Keeptheremotecontrolinaccessibletransmissiontotheindoorunit;
otherwise,thetimelagofupto15minuteswilloccur.
• Thesettingwillbesavedforthenextsameoperation.
1 3
Press SET .
2 4
Setthetimerwhentheairconditionerisoperating.
1Infraredsignalemitter
2Start/Stopbutton
3Modeselectbutton(MODE)
4Temperaturebutton(TEMP)
5Fanspeedbutton(FAN)
6Swinglouverbutton(SWING)
7Setlouverbutton(FIX)
8Ontimerbutton(ON)
9Offtimerbutton(OFF)
!Sleeptimerbutton(SLEEP)
"Setupbutton(SET)
#Clearbutton(CLR)
$ MemoryandPresetbutton(PRESET)
%One-Touchbutton(ONE-TOUCH)
&Highpowerbutton(Hi-POWER)
(Economybutton(ECO)
)Quietbutton(QUIET)
~Comfortsleepbutton(COMFORTSLEEP)
+PlasmaAirPurierbutton(PURE)
,Filterresetbutton(FILTER)
-ClockResetbutton(CLOCK)
.Checkbutton(CHK)
Press
ON
:SettheONtimer.
Press
OFF
:SettheOFFtimer.
Press
ON
:Setthedesired
   ONtimer.
Press
OFF
:Setthedesired
   OFFtimer.
Press SET buttonduringthe
( or )markashing.
PRESET OPERATION
14
Setyourpreferredoperationforfutureuse.Thesettingwillbememorizedbythe
unitforfutureoperation(exceptairowdirection).
 1.Selectyourpreferredoperation.
 2.Pressandhold
PRESET
for3secondstomemorizethesetting.ThePmark
displays.
 3.Press
PRESET
:Operatethepresetoperation.
AUTO RESTART OPERATION
15
Toautomaticallyrestarttheairconditionerafterthepowerfailure(Powerofthe
unitmustbeon.)
Setting
 1.PressandholdtheRESETbuttonontheindoorunitfor3secondstosetthe
operation.(3beepsoundandOPERATIONlampblink5time/secfor
5seconds)
 2.PressandholdtheRESETbuttonontheindoorunitfor3secondstocancel
theoperation.(3beepsoundbutOPERATIONlampdoesnotblink)
  • IncaseofONtimerorOFFtimeareset,AUTORESTARTOPERATION
   doesnotactivate.
Tooperateatsuperlowfanspeedforquietoperation(exceptinDRYmode)
 Press
QUIET
:Startandstoptheoperation.
 Note:Undercertainconditions,QUIEToperationmaynotprovideadequate 
  coolingorheatingduetolowsoundfeatures.
QUIET OPERATION
16
Forcomfortablesleep,automaticallycontrolairowandautomaticallyturnOFF.
 Press
COMFORT
SLEEP
:Select1,3,5or9hrsforOFFtimeroperation.
Note: Thecoolingoperation,thesettemperaturewillincreaseautomatically 
  1degree/hourfor2hours(maximum2degreesincrease).Forheating 
  operation,thesettemperaturewilldecrease.
COMFORT SLEEP OPERATION
17
OPERATION AND PERFORMANCE
21
 1.Three-minuteprotectionfeature:Topreventtheunitfrombeingactivatedfor
  3minuteswhensuddenlyrestartedorswitchedtoON.
 2.Preheatingoperation:Warmuptheunitfor5minutesbeforeblowingwarmair.
 3.Warmaircontrol:Whentheroomtemperaturereachesthesettemperature,
thefanspeedisautomaticallyreducedandtheoutdoorunitwillstop.
 4.Automaticdefrosting:Fanswillstopduringdefrostoperation.
 5.Heatingcapacity:Heatisabsorbedfromoutdoorandreleasedintotheroom.
Whentheoutdoortemperatureistoolow,useanotherrecommendedheating
apparatusincombinationwiththeairconditioner.
 6.Considerationforaccumulatedsnow:Selectthepositionforoutdoorunitwhere
itwillnotbesubjectedtosnowdrifts,accumulationofleavesorotherseasonal
debris.
 7.Someminor crackingsoundmayoccur whenunitoperating.Thisis normal
becausethecrackingsoundmaybecausedbyexpansion/contractionofplastic.
Note:Item2to6forHeatingmodel
Air conditioner operating conditions
Temp.
Operation Outdoor Temperature Room
Temperature
Heating –10°C~24°C Lessthan28°C
Cooling 15°C~46°C 21°C~32°C
Dry 15°C~46°C 17°C~32°C
The unit does not operate.
Cooling or Heating is abnormally low.
•
Thepowermainswitchisturnedoff.
• Thecircuitbreakerisactivatedto
 cutoffthepowersupply.
• Stoppageofelectriccurrent.
• ONtimerisset.
• Theltersareblockedwithdust.
•Thetemperaturehasbeenset
 improperly.
•Thewindowsordoorsareopened.
•Theairinletoroutletoftheoutdoor
 unitisblocked.
•Thefanspeedistoolow.
•
TheoperationmodeisFANorDRY.
TROUBLESHOOTING (CHECK POINT)
22
Tostartthesleeptimer(OFFtimer)operation
 Press
SLEEP
:Select1,3,5or9hrsforOFFtimeroperation.
SLEEP TIMER OPERATION
18
REMOTE CONTROL A-B SELECTION
23
Toseparateusingofremotecontrolforeachindoorunitincaseof2air
conditionersareinstallednearly.
Remote Control B Setup.
 1.PressRESETbuttonontheindoorunittoturntheairconditionerON.
 2.Pointtheremotecontrolattheindoorunit.
 3.PushandholdCHK●buttonontheRemoteControlbythetipofthepencil.
“00”willbeshownonthedisplay.
 4.Press
MODE
duringpushingCHK●.“B”willshowonthedisplayand“00”
willdisappearandtheairconditionerwillturnOFF.TheRemoteControlBis
memorized.
Note: 1.Repeatabovesteptoreset
   RemoteControltobeA.
  2.RemoteControlAhasnot“A”
   display.
  3.DefaultsettingofRemote 
   ControlfromfactoryisA.
PRESET
ONE TOUCH
QUIET
SWING
TIMER
ON
FILTER
CHECK
CLOCK
OFF
CLR
SLEEP
SET
FIX HI POWER ECO
PAP
COMFORT
SELECT
MODE
TEMP
FAN
SELF CLEANING OPERATION (COOL AND DRY
OPERATION ONLY)
20
Toprotectbadsmellcausedbythehumidityintheindoorunit.
 1.Ifthe buttonispressedonceduring“Cool”or“Dry”mode,thefanwillcontinue
torunforother20minutes,thenitwillturnoffautomatically.Thiswillreduce
themoistureintheindoorunit.
 2.Tostoptheunitimmediately,pressthemore2timeswithin30seconds.
Note:
• SELFCLEANINGoperationisdefaultsettingfromfactory.
• Tocancelthisfunction,pressandholdtheresetbuttonontheindoorunitfor
  20seconds.
  TheSELFCLEANINGoperationwillbecancelled.(5beepsoundbut
  OPERATIONlampdoesnotblink)
• Dothesametosetthisfunctionagain.(5beepsoundandOPERATIONlamp
  blink5times/secfor5seconds)
• AUTORESTARToperationwillbecancelledbysettingorcancellationof
  SELFCLEANINGoperation.Setitagainifneccessary.
Firstly,turnoffthecircuitbreaker.
Filter Reset
FILTERlamplightson;theltermustbecleaned.
Toturnoffthelamp,pushtheRESETbuttonontheindoorunitortheFILTERbutton
ontheremotecontrol.
Indoor Unit and Remote Control
• Cleantheindoorunitandtheremotecontrolwithawetclothwhenneeded.
• Nobenzine,thinner,polishingpowderorchemically-treatedduster.
Cleaning the air ionizer (Once every six months)
 1.Turnoffairconditionerusingremotecontrolandpowersupply.
 2.Fullyopentheverticalairowlouversbyhand.
 3.Useatoothbrushtorubtheendsofmetalpin
  threeorfourtimes.
Note: Donotusecottonswabsorotherobjects
   withuff.
   Evenbefore6monthssincelastcleaning,
   cleantheairionizerifitisdirty.
Cleaning the plasma air purier unit (About 1000 hours performed)
 1.Turnoffairconditionerusingremotecontrolandpowersupply.
 2.Takeouttheairinletgrille(Seedetailininstallationmanual).
 3.Takeouttheplasmaairpurierbygraspthehandle,andthepullitout
 4.Soakinhotwaterat40°Cto50°Cforabout10to15minutesandrubup,
  down,left,rightandrubsurfacegentlywithasponge.
 5.Allowtodrythoroughlyintheshade.
 6.Attachtheplasmaairpurierbygraspthehandleand
  insertintotherightandleftguiderails.
 7.Pressbothendsoftheplasmaairpurieruntilthe
  protrusionsonbothsidesoftheplasmaairpurier
  arecompletelyinsertd.
 8.Attachtheairlter,andthenclosetheairinletgrille.
MAINTENANCE
19