4PARTS NAME OF REMOTE CONTROLLER
Display section
In the display example, all indicators are displayed for the explanation.
In reality only, the selected contents are indicated.
•When turning on the leak breaker at the first time,
SETTING
flashes on
the display part of the remote controller.
•While this display is flashing, the model is being automatically confirmed.
Accordingly, wait for a while after
SETTING
display has disappeared, and
then use the remote controller.
Display
section
Operation
section
SET
TIME
TIMER SET
TEST
FILTER
RESET
TEMP.
CL
FAN
SAVE
SWING/FIX
VENT
MODE
ON / OFF
UNIT LOUVER
5
78 9216 15
3
4
614
11
13 12
10
1
1SETTING display
Displayed during setup of the timer etc..
2Operation mode select display
The selected operation mode is displayed.
3CHECK display
Displayed while the protective device works or a
trouble occurs.
4Timer time display
Time of the timer is displayed.
(When a trouble occurs, the check code is
displayed.)
5Timer SET IN setup display
When pushing the Timer SET button, the display
of the timer is selected in order of
[OFF] →[OFF] repeat OFF timer →
[ON] →No display.
6Filter display
If “FILTER ”is displayed, clean the air filter.
7TEST run display
Displayed during a test run.
8Louver position display
Displays louver position.
9SWING display
Displayed during up/down movement of the louver.
10 Set up temperature display
The selected set up temp. is displayed.
11 Remote controller sensor display
Displayed while the sensor of the remote controller is
used.
12 PRE-HEAT display
Displayed when the heating operation starts or
defrost operation is carried out.
While this indication is displayed, the indoor fan stops.
13 No function display
Displayed if there is no function even if the button
is pushed.
14 Air volume select display
The selected air volume mode is displayed.
(AUTO) (HIGH)
(MED.) (LOW)
15 Unit Number display
Unit number of the indoor unit selected with the unit
select button or abnormal indicate the indoor/outdoor
unit.
16 Central control display
Displayed when the air conditioner is used under the
central control in combination with a central control
remote controller.
In case the remote controller is disabled by the
central control system, flashes.
The button operation is not accepted.
Even when you push ON/OFF, MODE, orTEMP.
button, and the button operation is not accepted.
(Settings made by the remote controller vary with the
central control mode.For details, refer to the Owner’s
Manual of the central control remote controller.)