TR Equipment TR 4000 Atlas User manual

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT AB
Operating manual
Always study this manual carefully before operating the
Shower Trolley.
Operating instructions and recommended maintenance
procedures are explained in the following pages.
If you have any questions regarding the operation or
maintenance of your Shower Trolley and cannot nd the
answer in this manual, please contact us.
Only qualified staff, who understand all operating and
safety procedures may operate this equipment.
The Trolley is designed for years of trouble free opera-
tion, with proper use and maintenance.
Last modied: January 15, 2016

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
2
Intended Use Specification 3
Features and Controls for the Atlas Shower Trolleys 4
Audible tone sounds 5
Calibrating actuators 5
Hand Controls for up/down and tilting 5
New battery charger magnetic plug 6
Battery power and charging 7
Side rails 8
Head end rail 8
Corner bumper wheels 8
Central locking castor brakes and straight steering 9
Drain Hose and Plug 9
Patient Handling - Procedures for the Atlas Shower Trolleys 10
Patient Showering 10
Cleaning and disinfection of the Shower Trolley 10
Safety and Control Instructions 11
Routine Maintenance 12
Instructions how to inspect and control the side rail attachment
- not visible screws. 13
Labels TR 4000 14
Labels TR 4200 15
Warranty, CE mark and Technical Specifications 16
Maintenance record 17
Training record 18
Operating manual for:
Product Description Art no
TR 4000 Atlas Bariatric Shower Trolley, Working Load
Limit = 450 kg/ 1000 lbs 0521040
TR 4200 Atlas
Junior
Bariatric Shower Trolley, Working Load
Limit = 270 kg/ 600 lbs 0521050
Table of Content

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
3
Intended Use Specication
Device Model
TR 4000
The device “TR 4000” is a battery operated shower trolley. The device is foremost used for bariatric/overweight
patients.
The device is intended to ease transferring and caring of the patient. Typical situations where the device is used
include transporting the patient to and from a shower area, showering and cleaning the patient and dressing the
patient and changing diapers.
The patient is typically a person who is unable to take care of their own personal hygiene. The device is not intended
to be used with patients that exceed a weight of 450 kg.
The device is not intended to come in contact with injured skin.
The user is any adult person who is capable of reading and understanding the operating manual and is qualied to
care for dependent persons/patients.
Before using the device, the user must read and understand the operating manual.
The device is intended to be used indoors in all types of care facilities and private homes, including hygiene areas.
Device Model
TR 4200
The device “TR 4200” is a battery operated shower trolley. The device is foremost used for bariatric/overweight
patients.
The device is intended to ease transferring and caring of the patient. Typical situations where the device is used
include transporting the patient to and from a shower area, showering and cleaning the patient and dressing the
patient and changing diapers.
The patient is typically a person who is unable to take care of their own personal hygiene. The device is not intended
to be used with patients that exceed a weight of 270 kg.
The device is not intended to come in contact with injured skin.
The user is any adult person who is capable of reading and understanding the operating manual and is qualied to
care for dependent persons/patients.
Before using the device, the user must read and understand the operating manual.
The device is intended to be used indoors in all types of care facilities and private homes, including hygiene areas.

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
4
Position Description
1 Flexible drainage hose
2 Drainage
3 Mattress
4 Foldable side rail
5Foldable head rail for extra length (only TR 4000
Atlas)
6 Foot control brakes and straight steering
7 Bumper wheel
8 Column for height adjustments
9 Straight steering castor
10 Wedge pillow 15° (option)
11 Wedge pillow 30° (option)
12 Hand control
13 Up
14 Down
15 Tilting
Features and Controls for the Atlas Shower Trolleys
6
5
4
3
2
1
9
7
4
8
13
15
14
15
10
11
12

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
5
Audible tone sounds
Short tone
This tone informs that the stretcher is level when tilting
and stops. Proceed tilting by pressing once more on the
handcontrol when desired.
Long and short tone
When this tone sounds the Trolley needs to be charged,
see page 5.
Long and two short tones
If/When this tone sounds the stretcher actuators must
be calibrated to level.
Calibrating actuators:
Use the hand control to calibrate by pressing the DOWN
symbol until the stretcher stops in its lowest position.
Press the DOWN symbol once more to make sure that
both actuators are in their lowest positions.
Two short audible tones sound when both actuators are
in their lowest position. Press the DOWN symbol once
more and the stretcher is now calibrated and level.
Calibration must also be performed after each power
failure, for example after changing the batteries or the
fuse (15 A).
Hand Controls for up/down and tilting
The stretcher is easily and quietly raised by two powerful
actuators.
Load limit is up to 450 kg /1000 lb for TR 4000 Atlas
and 270 kg / 600 lbs for TR 4200 Atlas Junior.
The hand control operates the power when activated and
stops immediately when released.
The hand control also operates the tilting in both direc-
tions and raises / lowers the stretcher quietly.
Raise the Shower Trolley stretcher by activating the “UP”
arrow symbol.
Lower the Shower Trolley stretcher by activating the
”DOWN” arrow symbol.
When needed, the stretcher can be tilted max 4 degrees
in both directions by activating the tilt head- foot sym-
bols on the hand control for improved drainage and to a
Trendelenburg* position.
*NOTE: Only qualied staff who understands the proce-
dures may operate the Trolley with a patient in a “Trende-
lenburg” position.
Features and Controls for the Atlas Shower Trolleys

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
6
Features and Controls for the Shower Trolley
New battery charger magnetic plug for the TR 4000
Atlas/TR 4200 Atlas Junior shower trolley.
New battery charger magnetic plug is mounted on the TR
4000 Atlas from: Serial no: 1403-21856
New battery charger magnetic plug is mounted on the TR
4200 Atlas Jr. from: Serial no: 1401-21695
Charge the trolley daily or when a long and a short audible
tone sound.
Use only the 24V DC battery charger model delivered by
TR Equipment.
• NOTE: Connect the battery charger to the trolley
before it is connected to the mains.
Connect the battery charger magnetic plug into the
Shower Trolley battery box input, underneath the
stretcher. Make sure that the plug is completely in
place.
• Plug the battery charger into the mains.
• When the battery charger is properly connected, an
indicator on the battery charger will be lit. If not,
recheck the connections.
• The indicator informs of the charging cycles, yellow
while charging and green when the batteries are
fully charged.
• Maximum charging time is 8 hours. The batteries
can never be overcharged.
• When the charging is completed, disconnect the
battery charger from the mains, before you discon-
nect it from the trolley.
• A flat fuse (15 A) is connected between the batter-
ies in the battery box underneath the stretcher.
Batteries
If changing the lead batteries, deposit in accordance with
local regulations.

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
7
Battery power and charging
• Charge the Trolley, in dry rooms only, daily or when a
long and a short audible tone sounds. Normal charg-
ing time is approximately 8 hours when at. The Trol-
ley can never be overcharged.
• Use only the 24 volt DC battery charger model deliv-
ered by TR.
• Connect the battery charger into the Shower Trolley
battery box input, underneath the stretcher. Make
sure that the plug is fully in place.
• Plug the battery charger into the mains.
• When the battery charger is properly connected, an
indicator on the battery charger will be lit. If not, re-
check the connections.
• The indicator tells the charging cycles. Yellow during
charging and green indicates that the Trolley is ready
for use.
• When the charging is completed, disconnect the
charger from the mains before you disconnect the
charger from the battery box.
• A at fuse (15 A) is connected between the batteries
in the battery box underneath the stretcher.
Older vesions of Atlas/Atlas Junior
Older versions (Manufactured before September 2009)
had a battery charger input in the hand control.
Batteries
If changing the sealed lead-acid batteries, deposit in ac-
cordance with local regulations.
Features and Controls for the Atlas Shower Trolleys

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
8
Side Rails
The long side rails swing down for patient transfer and
lock in up position for person security.
Lower the side rail (horizontal) (A)
Lift the side rail with both hands and lower it to a horizon-
tal position where it stops.
Lower the side rail (all the way) (B)
Lift the side rail with both hands from the horizontal posi-
tion and lower it all the way.
Raise the side rail
Raise the side rail with both hands by simply lifting it
back into its upright position and it automatically locks in
place.
The stretcher width can be narrowed as the side rails can
be held in a vertical position when transporting the Trolley
through narrow doorways.
Head end rail (only TR 4000 Atlas)
The head end rail lowers down to a horizontal position for
extra person length and more access when transferring.
Lower the end rail (C)
Lift it with both hands and lower it.
Raise the head end rail
Raise the head end rail with both hands by simply lifting
it to its upright position where it automatically locks in
place.
Corner bumper wheels
The stretcher has rubber bumper wheels in all four cor-
ners to protect walls and doorways.
Features and Controls for the Atlas Shower Trolleys
A
C
B

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
9
Central locking castor brakes and straight steering
Castor Brakes
Park the Shower Trolley and brake all the four castors by
pushing the single foot central locking control bar, under
the Trolley head end, all the way down until it clicks in
position (D).
Release the brakes on all four castors by lifting the single
foot central locking control bar to its neutral position (E)
or push down the short ends on the foot control bar.
Straight Steering Castor
One of the foot end castors can be locked in a straight
steering position.
Lock the castor by lifting the foot central locking control
bar until it clicks to position or push down short ends on
the foot control bar (F). For stability make sure that the
straight steering castor i oriented according to picture F.
To release the straight steering castor, push the foot cen-
tral locking control bar down to its neutral position (E) or
lift the short ends on the foot control bar.
Drain Hose and Plug
Drain Hose
The exible drain hose connects to the drain outlet in the
mattress which prevents splashing.
To reduce water dripping on the oor, after use, fold the
drain hose nozzle upwards.
Drainage Plug
The drainage plug is fastened with a nylon string on the
stretcher foot end rail.
Features and Controls for the Atlas Shower Trolleys
D
E
F
Neutral
Neutral
Brake
Brake
2
1

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
10
Patient Showering
1. When showering, the patient must remain on the Shower
Trolley stretcher with the side rails securely locked.
2. Always physically ensure that the water temperature is as
required before and during showering.
3. Park the Shower Trolley foot end over a oor drain, sink
or WC. Brake all four castors by pushing the single foot
central locking control bar all the way down, until it clicks in
position (D).
4. When desired, attach the drainage hose and drain plug.
5. Tilt the stretcher max 4 degrees, with the hand control for
a comfortable position and good drainage. Remove the
drain plug, if desired.
6. Shower the patient. Body uids and faeces must be re-
moved immediately to prevent mattress stains.
7. After the patient is showered keep him/her warm wrapped
in a bath towel.
8. Thoroughly drain the stretcher and attach the drain plug to
prevent water dripping on oor. Fold the drain hose nozzle
upwards to prevent water dripping on the oor.
9. When desired, level the stretcher with the hand control. An
audible short tone sounds when the stretcher is back in
level.
NOTE: When the patient needs “Trendelenburg” position, only
qualied staff who understands the procedures may operate
the Trolley.
NOTE: Never leave patient unattended
Cleaning and disinfection of the shower trolley:
The unit must be cleaned and disinfected immediately after
use. Dry the unit well, before the mattress is put back on the
trolley and prepare the unit for its next use.
The shower trolley is manufactured and designed for easy
cleaning.
The stretcher has a removable mattress and pillow made of
PVC coated fabric.
WARNING:
Never clean the mattress and/or pillow in a gas sterilization
unit. Mattress and pillow will explode.
For a thorough cleaning of the shower trolley the mattress and
pillow should be removed.
Remove the mattress and then lift up the plastic plate
(TR 4200), plastic plates (TR 4000) and clean the underside of
the plastic plates and the entire stretcher.
After cleaning the complete stretcher, mattress and pillow,
thoroughly rinse the parts with the patient shower and wipe dry
before the trolley is returned to service.
Note, the use of detergents and disinfectants, respective
manufacturer’s instructions and recommendations, as well as
the instructions/notes described below.
Remarks:
• Use natural, slightly alkaline detergent containing no
solvents.
(Remove the detergent immediately after cleaning in
accordance with the specied exposure time)
• Do not use liquid solvent cleaners such as for example
trichlorethylene. This can damage the PVC coated fabric of
the mattress and pillow.
• Do not use iodine based disinfectants. These can discolor
the PVC coating on the mattress and pillow.
• Alcohol based disinfectants can be used but alcoholic
strength must not exceed 40 percent as there is a risk of
damage on the surfaces of the shower trolley.
• Do not use water hotter than maximum 45°C.
• Avoid excessive friction and abrasive detergents when
cleaning, as this may damage the surfaces of the shower
trolley.
• Do NOT put the shower trolley out to dry in the sun or near
a heater, as this may cause discoloration.
• Avoid damage from overheating.
• Regular cleaning prolongs the life-span of the product.
Talk to your suppliers and manufacturers of the disinfectants
that you use to clarify the utility of the disinfectant or to nd a
suitable disinfectant.
NOTE!
Wipe the stretcher dry also on the underside to prevent water
dripping on the oor.
NOTE!
Place only completely dry mattress and pillow on the shower
trolley.
Patient Handling - Procedures for the Atlas Shower Trolleys

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
11
If you have a question regarding the operation or
maintenance of your Shower Trolley and cannot nd the answer
in this manual, please contact us.
• Only qualied staff, who understand all operating and
safety procedures may operate the Trolley.
• The patient must be positioned comfortably on the
stretcher mattress, with side rails SECURELY locked.
• The patients body weight and/or body parts should never
lean or be supported against the stretcher side rails.
• Never leave the patient unattended.
• Check that the side rails are locked in place and free from
damage.
• Do not let the patient sit on the foldable short head end
rail on the stretcher.
• Castor brakes must be securely locked on the Trolley
before transferring a patient and once in position over a
drain.
• Check that braking attachments and casters are clean and
free from damage.
• Operate the Trolley carefully when transporting patients
through narrow corridors or over irregular uneven surfaces.
• Ensure that the Trolley can be moved, raised or lowered
without risking any pinch injuries to patient.
• Trolley must be cleaned after each use.
• Wipe underneath the stretcher to prevent water
dripping on the oor.
• Never clean mattress and pillow in gas sterilization unit.
Mattress and pillow will explode.
• Stretcher and mattress must be kept in place, well main-
tained and all screws must be tightened.
• Trolley must be inspected visually for signs of wear. Trolley
should not be used if defects are noted. Prompt service is
required.
• Use only a TR approved battery charger for the Trolley
• Do not use battery charger in wet or damp areas -
potential shock hazard.
• It is recommended that the Trolley batteries are charged
daily or whenever Trolley is not in use. Batteries can not
be overcharged.
WARNING: Do not use the Shower Trolley in any way that
varies from the safety precautions and operating procedures
detailed in this manual. The equipment must not be operated
by anyone until the user has read and understood the instruc-
tions in this manual.
Safety and Control Instructions

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
12
The recommended frequency of these maintenance
routine procedures will depend on how often the
equipment is used. It is good practice to establish these
procedures and then adjust the frequency as your
conditions indicate. TR Equipment recommends a
schedule is kept on le with signatures of the
individual(s) conducting the inspections should
questions arise at a later date. The shower trolley
should immediately be taken out of operation if defects
or irregularities are noted. Prompt service is required.
Daily Maintenance
• Clean the Trolley, mattress and pillow after each use
with mixed, nonabrasive type of detergent, according
to your detergent supplier instructions.
Note: Do not use solvent based cleaning liquids,
which can damage or stain the PVC coating on the
mattress and pillow.
• Use a sponge or brush and remove any soap or lime
deposits and feces promptly to avoid spots/stains.
Rinse thoroughly with fresh water.
Warning: Never clean mattress and pillow in gas
sterilization unit. Mattress and pillow will explode.
• For complete cleaning and disinfection instructions,
please see page 10.
• It is recommended that the Trolley batteries are
charged daily or whenever the shower trolley is not in
use. Batteries cannot be overcharged.
• Check that actuators are calibrated (calibration is
needed if actuators are moving with uneven speeds,
stretcher can’t be tilted to horizontal position or if
there is an audible signal when raising/lowering,
see page 5.)
Weekly Maintenance
• Visually inspect the Shower Trolley interior to make
sure there are no nicks or cracks which may scratch
the patient.
• Check that all tubes have plastic caps on to prevent
water getting inside the tube, if not add new ones.
Monthly Maintenance
• Check that all screws and fastenings are tight.
It’s important that all screws and fastenings are
checked and tightened if needed – including those
not easily visible. Check the fastenings and screws
inside the cover plugs.
• Check components for signs of damage/high level of
wear. Visually inspect the Shower Trolley interior
to make sure there are no nicks or cracks which may
scratch the patient.
• Both actuators on the Shower Trolley must be
inspected visually for signs of wear. Raise and lower
the stretcher to easier identify any damages/signs of
wear.
• Side rails should be inspected to ensure they are in
good condition and that all fasteners are in place and
functioning properly.
• Castors should be inspected to ensure they are clean
and that the locking and straight steering are fully
functioning.
• Tilting mechanism should be examined by activating
the hand control to ensure that it is functioning
properly.
• Hand control should be inspected for any signs of
damage to ensure functionality.
• Check the electrically height adjustable system on
the TR 4000 / TR 4200 to ensure that the system
works smoothly throughout the entire lift range.
Annual Maintenance
• Thorough inspection of all the above maintenance
instruction and assessment of general condition and
functionality of the Shower Trolley should be
performed. We recommend that this is done by us
approved and designated staff.
• Trolleys should be immediately taken out of operation
if defects or irregularities are noted. Prompt service
is required.
Batteries
• If changing the lead batteries,
deposit in accordance with local
regulations.
We recommend that the batteries
in the product are replaced
every three (3) years.
Routine Maintenance

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
13
Instructions how to inspect and control the side rail
attachment - not visible screws.
1. Remove the pillow-mattress-drainage hose and break the castors.
2. Remove the corner bumper wheel screw and pry
open the corner 1-2mm to pull out the wheel.
Protect the paint from scratching.
3. When a bumper wheel is removed you can locate
two Allen Key side rail screws assembled to the
stretcher frame square tubing.
Check that these are tight and fastened.
Allen key screw with Driloc.
4. Reassemble the corner bumber wheel and put the mattress-pillow and drainage hose back to their intended
places.

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
14
Tilting instruction: Press the lower left button on the hand control to
raise the head end and press the lower right button on the hand control
to raise the foot end of the stretcher.
Foot control instruction: You can set the foot control in 3 different posi-
tions:
Black: Straight Steering, Green: Neutral, Red: Brake
Driving Direction Figure: The attendant driving the shower trolley must
always be placed at head end side.
Maximum working Load
Mandatory to read the operating manual before use.
TR Equipment AB Logotype.
The identication label states the product’s model- and part number,
serial number, date of manufacture, the manufacturing country and the
name and address of the manufacturer.
REF = Model– and part number
CE = CE marking in accordance with the Medical Devices
Directive 93/42/EEC as a Medical Device Class 1.
SN = Serial number
Labels on the TR 4000
TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Labels on the TR 4000

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
15
Tilting instruction: Press the lower left button on the hand control to
raise the head end and press the lower right button on the hand control
to raise the foot end of the stretcher.
Foot control instruction: You can set the foot control in 3 different posi-
tions:
Black: Straight Steering, Green: Neutral, Red: Brake
Driving Direction Figure: The attendant driving the shower trolley must
always be placed at head end side.
Maximum working Load
Mandatory to read the operating manual before use.
TR Equipment AB Logotype.
The identication label states the product’s model- and part number,
serial number, date of manufacture, the manufacturing country and the
name and address of the manufacturer.
REF = Model– and part number
CE = CE marking in accordance with the Medical Devices
Directive 93/42/EEC as a Medical Device Class 1.
SN = Serial number
Labels on the TR 4200

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
16
Warranty
TR warrants that its products are free from defects in
materials and workmanship for a period of one year from
the date of delivery.
TR mattresses of fabric covered PVC over polyester foam
shall be warranted for a period of six months from the
date of delivery.
The above warranty obligations shall be limited to deliv-
ery of defective parts.
TR warrants that service or repairs of products no longer
in warranty will be performed in a workman like manner
and warrants them for a period of 30 days, when per-
formed by service personnel authorized by TR.
This warranty is in lieu of any other warranty or represen-
tation, expressed or implied.
Warranties of MERCHANTABILITY or FITNESS FOR ANY
PARTICULAR USE OR PURPOSE are expressly excluded.
TR will not be responsible for any expenses, inconven-
ience or incidental or consequential damages occa-
sioned by the use, loss of use, or misuse of the prod-
ucts, or by the failure of the products to conform to the
warranty set forth above.
This warranty becomes void if the product shows evi-
dence of mishandling, tampering, installation or use
contrary to the applicable instruction materials, ship-
ping damage, or repair performed by other than service
personnel authorized by TR. Routine cleaning, adjust-
ment, and normal cosmetic and mechanical wear are not
covered by this warranty.
TR reserves the right to make design changes and/or
improvements without notice.
Warranty, CE Mark and Technical Specications
Technical Specifications
TR 4000 Atlas TR 4200 Atlas Junior
Length 2210 mm / 87” 2150 mm / 85”
Width 915 mm / 36” 740 mm / 29”
Height 535-835 mm
21” - 33”
535-835 mm
21” - 33”
Working Load
Limit 450 kg / 1000 lbs 270 kg / 600 lbs
Chassis Powder coated and
zinc plated steel
Powder coated and
zinc plated steel
Castors
Brakes on all four
castors and straight
steering
Brakes on all four
castors and straight
steering
Control
Hand control for
height adjustment
and tilting
Hand control for
height adjustment
and tilting
Mattress, pillow Flame retardant
material
Flame retardant
material
Battery Rechargeable, 24 V Rechargeable, 24 V
Registered at Medical Products Agency,
Sweden, as MD Class 1, MDD 93/42EEC.
Made in Sweden
Manufactured by: TR Equipment AB
Rundelgatan 2
573 35 Tranås
Sweden

TR 4000 Atlas/TR 4200 Atlas Junior
Bariatric Shower Trolleys
Hygiene Equipment Designed for People
www.trequipment.com
TR EQUIPMENT
TR EQUIPMENT AB P.O Box 116, S-573 22, TRANÅS, SWEDEN Phone: +46 140-38 50 60 Fax: +46 140-38 50 61
TR GROUP INC. 2990 NORTH PERRYVILLE RD, STE 2300, ROCKFORD, IL 61107, USA Phone: +1 800-752-6900 Fax: +1 815 633-0549
TR EQUIPMENT UK LTD. INNOVATION CENTRE,GALLOWS HILL, WARWICK CV34 6UW ENGLAND Phone: +44 844 335 8386 Fax: +44 844 335 8383
TRANSPOREHAMED GMBH GRÜNBAUMSTR. 89 42659 SOLINGEN. GERMANY Phone: +49 (0) 212-645850-0 Fax: +49 (0)212-645850-50
17
Maintenance record
Date Description Signed by
Training record
Date Description Signed by
This manual suits for next models