Table of contents
Notes regarding the operating manual.................................1
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................5
Assembly and installation.....................................................5
Operation ...............................................................................7
Errors and faults..................................................................10
Maintenance ........................................................................12
Technical annex...................................................................15
Disposal ...............................................................................17
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning!
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution!
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
The current version of the operating manual can be found at:
TTK 95 E
http://hub.trotec.com/?id=39477
Legal notice
This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
TrotecGmbH&Co.KG. The same applies for electronically
processing, duplicating or spreading the publication. Subject to
technical changes. All rights reserved. Trademarks are used
without guarantee that they may be used freely and primarily
following the spelling of the manufacturer. Product names are
registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. TrotecGmbH&Co.KG
accepts no liability whatsoever for possible mistakes or
omissions.
© TrotecGmbH&Co.KG

EN 2
Operating manual – dehumidifier TTK 95 E
Warranty and liability
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the chapter Errors and faults,
please get in touch with your dealer or distributor.
When making a warranty claim, supply the device number (see
the rear of the device).
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement
of individual parts can drastically impact the electrical safety of
this product and will result in the loss of the warranty. Liability
does not extend to damages to people or property caused by the
device being used other than as described in the instructions in
this operating manual. Subject to changes to technical design
and model changes as part of constant development and
product improvement without prior notice.
No liability is accepted for damages resulting from improper
use. In such a case, any warranty claims will be voided also.
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Set the device up in an upright and stable position.
• Let the device dry out after a wet clean. Do not operate it
when wet.
• Do not use the device with wet or damp hands.
• Do not expose the device to directly squirting water.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
Defective power cables pose a serious health risk.
• Observe the storage and operating conditions (see chapter
Technical data).
• Ensure that the air inlet and outlet are not obstructed.
• Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
• Only transport the device in an upright position with an
emptied condensation tank or drain hose.
• Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

3 EN
Operating manual – dehumidifier TTK 95 E
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:
• dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats
• maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.
Improper use
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device outdoors.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
• Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning!
The device is not a toy and does not belong in the
hands of children.
Warning!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Switch the device off and disconnect the power
cable from the mains socket. Hold onto the mains plug
while doing so.
2. Do not reconnect a defective device to the mains.

EN 4
Operating manual – dehumidifier TTK 95 E
Information about the device
Device description
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to
approx. 30 %.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.
Device depiction
1
2
3
4
5
6
7
8
9
No. Designation
1 Control panel
2 Condensation tank with filling level indicator
3 Air inlet with air filter
4 Condensation drain hose connection
5 Power cable winder
6 Air filter
7 Wheels
8 Transport handle
9 Air outlet

5 EN
Operating manual – dehumidifier TTK 95 E
Transport and storage
Transport
Before transporting the device, proceed as follows:
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• To make the device easier to transport, it is fitted with
wheels.
• Do not use the power cable to drag the device.
• Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
• Set up the device in an upright position after transport.
• Leave the device to rest for 12-24hours, so the
refrigerant can accumulate within the compressor.
Wait 12-24hours before switching the device back on!
Acting contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
Storage
Before storing the device, proceed as follows:
• Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
• Empty and clean the condensation tank prior to storage.
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and installation
Scope of delivery
• Device
• Air filter
• Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in chapter Technical
Data.
A
B
C
C
D

EN 6
Operating manual – dehumidifier TTK 95 E
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Set the device up in an upright and stable position.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to
heat sources.
• Make sure that no curtains or other objects interfere with
the air flow.
• When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
• Ensure that the float inside the condensation tank is
inserted correctly.
• Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
• Insert the mains plug into a properly secured mains
socket.

7 EN
Operating manual – dehumidifier TTK 95 E
Operation
• Avoid open doors and windows.
• After being switched on, the device operates fully
automatically.
• The fan permanently runs in dehumidification mode even
after the set nominal value has been reached until the
device is switched off.
Operating elements
11
10 12 13 14
1923
15 16 17 18
202122
No. Designation Meaning
10 Swing function button Switches the automatic movement of the
ventilation flap on or off
11 Increase value button Setting the desired relative room humidity
Setting the number of hours for the timer
function
12 Current room humidity
indication
Indicates that the current relative room
humidity is being displayed
Disappears when the desired relative room
humidity is being set
13 Room humidity segment
display
Indicates the current relative room humidity
Indicates the desired relative room
humidity during setting
14 Defrost indication Is displayed when automatic defrosting is
in progress
15 Fan speed indication Indication of the fan speed:
= low
= high (laundry drying function)
16 Swing function indication Is displayed when the swing function is
activated
17 Ventilation button Setting the fan speed:
= low
= high (laundry drying function)
18 Power button Power button:
Switches the device on or off
19 Timer button Starts programming for the timer function
20 Condensation tank full
indication
Is displayed when the condensation tank is
full or not installed correctly
21 Timer indication Is displayed when the timer is activated
Indicates the number or hours set
ON = automatic switch-on enabled
OFF = automatic switch-off enabled
22 Desired room humidity
indication
Is displayed while the desired relative room
humidity is being set
23 Decrease value button Setting the desired relative room humidity
Setting the number of hours for the timer
function

EN 8
Operating manual – dehumidifier TTK 95 E
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the power button(18).
ðThe unit starts to dehumidify.
Setting the operating mode
Setting the desired relative room humidity
You can change the desired relative room humidity at any time.
1. Press the increase value (11) or decrease value button(23)
to set the desired relative room humidity. Setting is possible
in the range between 30 % and 90 % in steps of 5 %.
ðThe desired relative room humidity is shown on the room
humidity indication(13) for approx.5seconds. Then the
current relative room humidity is displayed again.
Setting the fan speed
You can choose between low and high fan speed (laundry drying
function) at any time.
1. Press the fan button(17) to select either low or high fan
speed (laundry drying function).
ðThe selected fan speed is indicated on the fan speed
indication(15).
Dehumidification
The device keeps running until reaching the desired relative
room humidity. Then the compressor switches off and the fan
keeps running. Once the desired relative room humidity is
exceeded, the compressor switches back on.
The desired relative room humidity can be set within a setting
range from 30 % to 90 % in steps of 5 % at any time.
You can choose between low and high fan speed (laundry drying
function).
Setting the timer
The timer has two modes of operation:
• automatic switch-on upon expiry of a preset number of
hours.
• automatic switch-off upon expiry of a preset number of
hours.
The number of hours can be between 1 and 24 and can be
adjusted in increments of 1h.
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
1. Switch off the device.
2. Press the timer button(19).
ðThe number of hours flashes on the timer
indication(21).
3. Press the increase value (11) or decrease value button(23)
to set the desired number of hours.
4. Wait for approx. 5seconds in order to save the setting.
ðThe characters ON and the number of hours left until
switch-on appear on the timer indication(21).
ðThe timer setting equals the desired number of hours.
ðThe device starts after the set time has passed.
Note regarding automatic switch-on:
• Pressing the power button(18) deactivates the automatic
switch-on function.
Automatic switch-off
üThe device is switched on.
1. Press the timer button(19).
ðThe number of hours flashes on the timer
indication(21).
2. Press the increase value (11) or decrease value button(23)
to set the desired number of hours.
3. Wait for approx. 5seconds in order to save the setting.
ðThe characters OFF and the number of hours left until
switch-off appear on the timer indication(21).
ðThe timer setting equals the desired number of hours.
ðThe device switches off after the set period of time.
Auto stop function
If the water tank is full, not inserted correctly or the desired
relative room humidity has been reached, the device will stop
automatically.
Swing function
Using the swing function, you can activate continuous
movement of the ventilation flap. This enables an even
distribution of the air current in the room.
1. Press the swing function button(10).
ðThe ventilation flap moves up and down continuously.
2. Press the swing function button(10) again to deactivate the
swing function. The ventilation flap opens completely.

9 EN
Operating manual – dehumidifier TTK 95 E
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect a suitable condensation drain hose to the device.
üA suitable hose (diameter: 13mm) is ready for use.
üThe device is switched off.
1. Remove the sealing cap from the hose connection.
2. Remove the rubber plug.
3. Push one end of the hose onto the hose connection.
4. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please observe that the
hose must not be kinked.
Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
The hose can be connected in any operating mode for
continuous operation.

EN 10
Operating manual – dehumidifier TTK 95 E
Automatic defrost
At low ambient temperatures (below 12°C), ice may form at the
evaporator during dehumidification. The device will then carry
out an automatic defrost. Dehumidification is briefly interrupted
during defrosting.
Info
We do not recommend operating the device at
temperatures below 5°C.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
The defrost indication(14) is illuminated during automatic
defrosting.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
• cupboard dry = 46 % relative humidity
• iron dry = 58 % relative humidity
• slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity
level.
1. Select the highest fan speed by use of fan button(17).
ðThe function for drying laundry is activated.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• If necessary, remove the condensation drain hose and any
residual fluid from it.
• Empty the condensation tank, if need be.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damages.
• Check the on-site fusing.
• Check the filling level of the condensation tank and empty
it if necessary. The condensation tank full indication(20)
must not light up.
• Check the condensation tank for correct seating.
• Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but no condensate forms:
• Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
• Ensure that the relative room humidity complies with the
technical data.
• Check the preselected desired room humidity level. The
relative humidity in the room must be above the selected
range. If necessary, reduce the preselected desired room
humidity.
• Check the air filter for dirt. If necessary, clean or replace
the air filter.
• From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
• The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.

11 EN
Operating manual – dehumidifier TTK 95 E
The device is loud or vibrates:
• Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
• Check the device for leaks.
The compressor does not start:
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
• Ensure that the relative room humidity complies with the
technical data.
• Check the preselected desired room humidity level. The
relative humidity in the room must be above the selected
range. If necessary, reduce the preselected desired room
humidity.
• Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
• The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
• Check the air inlets and air filter for dirt. Remove external
dirt.
• From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.

EN 12
Operating manual – dehumidifier TTK 95 E
Maintenance Maintenance intervals
Maintenance and care interval before every
start-up
as needed at least every
2 weeks
at least every
4 weeks
at least every
6 months
at least annually
Empty condensation tank and drain hose X
Check the air inlets and outlets for dirt and
foreign objects and clean if necessary
X X
Clean the exterior X X
Visually check the inside of the device for
dirt
X X
Check the air filter for dirt and foreign
objects and clean or replace if necessary
X X
Replace air filter X
Check for damage X
Check the attachment screws X X
Test run X
Maintenance and care log
Device type: ............................................. Device number: ....................................
Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Empty condensation tank and drain hose
Check the air inlets and outlets for dirt and
foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for
dirt
Check the air filter for dirt and foreign
objects and clean or replace if necessary
Replace air filter
Check for damage
Check the attachment screws
Test run
Remarks:
1. Date: ................................
Signature: ............................
2. Date: ................................
Signature: ............................
3. Date: ................................
Signature: ............................
4. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
11. Date: ..............................
Signature: ............................
12. Date: ..............................
Signature: ............................
13. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................

13 EN
Operating manual – dehumidifier TTK 95 E
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch off the device.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.
Cleaning the housing
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
5. Put the air filter back in.
Refrigerant circuit
• The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and
air-conditioning or by Trotec.
Cleaning the air filter
Note
Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.

EN 14
Operating manual – dehumidifier TTK 95 E
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device.
Emptying the condensation tank
If the condensation tank is full or not installed correctly, the
condensation tank full indication(20) will light up on the control
panel. The compressor and fan will switch off. An acoustic
signal will sound for 5seconds.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned correctly.
Also make sure that the condensation tank is inserted
correctly, otherwise the device cannot be switched back on.
Activities required after maintenance
If you want to continue using the device:
• Leave the device to rest for 12-24hours, so the
refrigerant can accumulate within the compressor.
Wait 12-24hours before switching the device back on!
Acting contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Storage chapter.

15 EN
Operating manual – dehumidifier TTK 95 E
Technical annex
Technical data
Parameter Value
Model TTK95E
Max. dehumidification performance 30 l / 24 h
Dehumidification performance
@ 30°C and 80% RH
28 l / 24 h
Air volume flow 200 m3/h
Ambient temperature 5°C to 32°C
Operating range relative humidity 30 % to 80 % RH
Mains connection 1/N/PE ~ 230 V/ 50 Hz
Power input 0.6 kW
Nominal current 2.6 A
Refrigerant R134a
Amount of refrigerant 215 g
Condensation tank capacity 5.3 l
Sound pressure level (1m distance) 47 dB(A)
Dimensions (length x width x height) 240 x 368 x 560 (mm)
Minimum distance to walls and other
objects
A: top:
B: rear:
C: side:
D: front:
20 cm
20 cm
20 cm
20 cm
Weight 16 kg
Wiring diagram
SCHEMATICWIRINGDIAGRAM
N
(/1
<(//2:*5((1
%52:1&2035(66252/3%/$&.5('5('<(//2:7$/9%/8(
%/8(%/8(
&$3$&,725)86(&$3$&,725%/8(
%/$&.
:+,7(
:+,7(
+,/2&1&1&1&1&1&21752/%2$5'
&20
7VHQVRU$&&25'+VHQVRU
12
N N N
67(33,1*02725)$1027250,&526:,7&+

EN 16
Operating manual – dehumidifier TTK 95 E
Spare parts drawing and list Info
The position numbers of the spare parts differ from
those describing the positions of other parts mentioned
in this operating manual.
47

17 EN
Operating manual – dehumidifier TTK 95 E
No. Spare part No. Spare part No. Spare part
1 BASE PAN 18 CAPACITOR(30uf/450V FOR COMPRESSOR (3)) 35 POWR WIRING BUCKLE
2 TURING WHEEL 19 FIX METAL 36 REAR PANEL
3 COMPRESSOR ASS'Y(35D042-B1) 20 GEAR 37 DRAIN BUCKET
4 RUBBER 21 STRIKE 38 DRAIN BUCKET
5 SUCTION PIPE 22 CAPILLARY TUBE 39 TANK LID
6 DISCHARGE PIPE 23 SENSOR 40 HANDLE
7 PLATE 24 FIX TUBE 41 VAN AIR DEFLEETOR
8 DRAINAGE PAN 25 CAPACITOR(1uF450V for motor(12)) 42 LNTAKE GRILLE
9 EVAPORATOR ASS'Y 26 ELECTRIC BOX 43 SOFT CAP
10 CONDENSER ASS'Y 27 PROTECT COVER 44 PLUG
11 FAN CASING BOX 28 CONTROL BOARD 45 SOFT CAP
12 FAN MOTOR(WF4-012D2-82D-NHAF) 29 PC BOARD 46 TOP COVER
13 BLOWER WHEEL 30 FIX METAL 47 HANDLE
14 FAN TANK 31 SENSOR (FOR EVAPORATOR ASS'Y(9)) 48 FIX TUBE
15 DISCHARGE GRILLE 32 POWER SUPPLY CORD COMPLETET ASS'Y 49 Y TUBE
16 MICRO SWITCH 33 DECORATIVE PLARES 50 OVER LOAD PROTECTOR(B90-135D-241A)
17 FIX TUBE 34 DECORATIVE PLARES
Disposal
In the European Union, electronic equipment must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2012/19/EU of the
European Parliament and of the Council of 4 July 2012 on waste
electrical and electronic equipment (WEEE). At the end of its life,
please dispose of this device according to the valid legal
requirements.
The device uses an environmentally and ozone-neutral cooling
agent (see Technical Data).
Dispose of the refrigerant appropriately and according to the
national regulations.


Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
www.trotec.com
Table of contents
Other Trotec Dehumidifier manuals

Trotec
Trotec TTK 120 S User manual

Trotec
Trotec TTR 5200 User manual

Trotec
Trotec TTP 1 E User manual

Trotec
Trotec DH 30 VPR+ User manual

Trotec
Trotec TTK 125 S User manual

Trotec
Trotec TTK 75 S User manual

Trotec
Trotec TTK 28 E User manual

Trotec
Trotec TTK 30 S User manual

Trotec
Trotec TTR 10000 User manual

Trotec
Trotec TTR 56 E User manual

Trotec
Trotec TTP 5 E User manual

Trotec
Trotec TTK 120 E User manual

Trotec
Trotec TTK 100 S User manual

Trotec
Trotec TTR 250 EX User manual

Trotec
Trotec TTK 500 User manual

Trotec
Trotec ttk 71 e User manual

Trotec
Trotec TTR 400 User manual

Trotec
Trotec TTK 100 E User manual

Trotec
Trotec TTK 54 E User manual

Trotec
Trotec TTK 67 E User manual