EN 8
Operating manual – dehumidifier TTK 96 E / TTK 127 E
Shutdown
Danger!
Do not touch the mains plug with wet or damp hands.
1. Press the POWER button(21).
2. Remove the mains plug from the mains socket.
3. If necessary, remove the condensation drain hose and any
residual fluid from it.
4. Empty the condensation tank, if need be.
5. Clean the device, and especially the air filter, according to
the chapter Maintenance.
6. Store the device according to the chapter Storage.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Note:
Wait for at least 3 minutes after maintenance and repair work.
Only then switch the device back on.
The device does not start:
• Check the power connection.
• Check the mains plug for damages.
• Check the condensation tank for correct seating. Check the
filling level of the condensation tank and empty it, if
necessary. The indicator lightmust not light up.
• Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but no condensate forms:
• Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
• Check the air filter for dirt. If necessary, clean or replace
the air filter.
• From the outside, check the condenser for dirt (see
chapter Maintenance). If your condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device is loud or vibrates; condensate is leaking:
• Check whether the device is standing upright and on an
even surface.
The device gets very warm, is loud or loses power:
• Check the air inlets and air filter for dirt. Remove external
dirt.
• From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.
Your device still does not operate correctly after these
checks?
Have the device repaired by authorised expert staff or by Trotec.
Error codes
The following error codes can be displayed:
Error code Cause Remedy
AS Error humidity sensor Disconnect the device briefly from
the mains.
Should the error still be displayed
after the restart, please contact
the customer service.
ES Error at the temperature
sensor of the evaporator
Disconnect the device briefly from
the mains.
Should the error still be displayed
after the restart, please contact
the customer service.
P2 Condensation tank full or
not inserted correctly
Empty the condensation tank or
check the condensation tank for
correct fit.
EC Leakage in the refrigerant
circuit
Switch the device off and contact
the customer service.
Also see the information regarding
the refrigerant circuit in chapter
Maintenance.
E3 General fault at the device Disconnect the device briefly from
the mains.
Should the error still be displayed
after the restart, please contact
the customer service.