Operating manual – IDS 100
B-2 EN
4. General safety instructions
Please observe the following safety instructions! Any non-compliance with these instructions may have serious consequences for the health of per-sons and could result in property damage and damage to the environment. Risk of explosion!
• Do not operate the device in potentially flammable or explosiveenvironments. Do not install it in such environments, either.• Do not place the device on a flammable surface.• Remove any inflammable materials and chemicals from the im-mediate operating environment.Functional impairment of and damage to the device!
• Do not use the device outdoors.• Install the device in a stable position.• Keep the intake and exhaust openings free. • Do not cover the device during operation.• Only disconnect the device from the mains once it has cooleddown completely.• Do not use any chemicals for cleaning the device.Risk of injury and damage to property due to defective devices!
• Before each use of the device, check its accessories and connec-tion parts for possible damages. Do not use any defective devicesor device parts. • Do not use the device if you detect any damage to its plug andcables. Defective power cables represent a serious health threat.Danger to life through electrical shock!
• Only connect the device to power sources that are in good tech-nical order. Do not use damaged wall outlets!• Pull the connection cable out of the wall outlet by pulling it atits plug. • Do not touch electrical connection cables when your hands arewet!• Protect the electrical connection cables against damage causedby, for example, animals.• Do not carry out any changes or repairs on the device!• Do not expose the device to any liquids. • Do not apply any liquids to the interior of the device. If this doeshappen nevertheless, pull out the power cord and have the de-vice checked by a specialist workshop.Risk of injury!
• Do not insert any objects into the intake and exhaust opening ofthe device.• Do not reach into the existing openings.• Do not leave children or animals unattended near the operatingdevice!• Do not operate the device in rooms with insufficient supply ofcombustion air.• Avoid the improper use of fuels.Risk of environmental pollution!
• Do not let any leaked fuel seep away into the soil and prevent itfrom entering the sewer system.5. Function and product characteristics
The oil heating unit IDS 100 is used to heat up room air in order to achieve a fast heating of large rooms. The oil heating unit is operated with heating oil. The device features an indirect combustion and is provided with an exhaust connection in order to discharge the exhaust gas via the chimney.A selection of two operating modes ensures that the oil heating unit can be controlled both manually by the user as well as automatically with the support of the thermostat.6. Technical data Type IDS 100ParameterValueArticle number1.430.000.140Electrical connection230 VFrequency50 Hz Nominal current max.8.35 A Power consumption1820 W Air volume5500 m³/h FanAxial fanNominal heat load max.118 kWNominal heat output105.5 kWTemperature increase ΔT 1)75 °COil consumption max.10.79 l/hTank capacity135 lAir transportation hose connection 2)1 x ø 500 mm, L-max = 6 m
Air transportation hose connection 2)1 x ø 400 mm, L-max = 6 m
Chimney connectionø 150 mmThermostat connectionseriesCombustionindirectNozzle2.00-80° W (gal/h)Sound pressure level (at distance of1 m)76 dB (A)Length1918 mmWidth731 mmHeight1220 mmWeight 149 kgFuse16 A1) indicates the temperature increase. ΔT + ambient temperature = exhaust air temperature2) optional