Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................4
Transport and storage...........................................................5
Assembly and installation.....................................................6
Operation ...............................................................................8
Available accessories............................................................9
Errors and faults..................................................................10
Maintenance ........................................................................11
Technical annex...................................................................15
Disposal ...............................................................................15
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
B 7 E
https://hub.trotec.com/?id=45089
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms or
areas and do not install it there.
• Do not use the device in aggressive atmosphere.
• Only put up the device in an upright, stable position on firm
ground.
• Do not expose the device to directly squirting water.
• Fill the device with clear drinking water only.
• Never insert any objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• This appliance is not a toy. Keep away from children and
animals. Do not leave the device unattended during
operation.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The mains connection must correspond to the
specifications in the Technical annex.

EN 3
humidifier B 7 E
• Insert the mains plug into a properly fused mains socket.
• Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• Make sure that the air inlet and outlet are not obstructed.
• Make sure that the suction side is kept free of dirt and
loose objects.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Do not use the device when the water tank is empty.
• Before filling the water tank, switch the device off and
disconnect the power cable from the mains socket. Hold
onto the mains plug while doing so.
• Only transport the device in an upright position with an
emptied water tank.
• Empty and clean the water tank prior to storage or
transport. Do not drink the water. Health hazard!
• Note that high humidity levels may enhance the growth of
biological organisms in the environment.
• Make sure that objects in the surroundings of the device
do not become wet or damp. If moisture is present, the
output must be reduced. Set the device to a lower level. If
the output cannot be reduced, the device must only be
operated in intervals. If necessary, switch the device off
completely for a short time. Absorbent materials such as
carpeting, curtains, sheers or tablecloths must not become
damp.
• Make sure that the water in the water thank is replaced
every3days. Otherwise there is a risk of microorganisms
growing in the water tank which presents a health hazard
if they get into the air or water.
• This device contains a UVlamp. Do not look into the light
source for too long.
Intended use
Only use the device as a mobile humidifier for the humidification
and filtration of room air, while adhering to and following the
technical data.
Intended use comprises humidifying the room air in:
• living spaces
• warehouses and archives
• libraries
• call centres and computer rooms
Foreseeable misuse
The device is not intended for industrial use.
• Do not place the device on wet or flooded ground.
• Do not place any objects, e.g. clothing, on the device.
• Do not use the device out of doors.
• Do not make any unauthorised modifications, alterations or
structural changes to the device.
• Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Symbols Meaning
This symbol located on the device indicates that
the water tank should be cleaned every3days.
Change the water in the water tank every3days.
Disconnect the device from the mains before
cleaning the water tank.
Operate the device with the adapter supplied by the
manufacturer.

4 EN
humidifier B 7 E
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Caution
If the device is knocked over, water will leak from the
lower part.
Disconnect the device from the mains to prevent
damage to the device caused by dry running.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Device description
The device B 7 E functions as a humidifier, aroma diffuser and
air cleaner.
The ultrasound technology ensures a pleasant room climate and
air quality improvement.
The capacity of the water tank of5l allows for a running time of
approx.16hours.
The device switches off automatically when the water tank is
empty.
Scented oil can be added to the scented oil tank for optional
room air aromatization.
The device comes with an automatic mode, a night mode and a
timer function. The timer function can be programmed for
automatic switch-on and switch-off after1to12hours.
An integrated antibacterialUV lamp works automatically and
reduces bacteria inside the water tank.
Device depiction
1
2
3
4
5
76

EN 5
humidifier B 7 E
8
10
9
11
12
13
14
No. Designation
1Lid with air outlet
2Air outlet
3Water tank
4Bottom section
5Control panel
6Cover with carbon filter(air filter)
7Mains connection(adapter)
8Cover for water filter
9Air nozzle
10 Nebulizer membrane
11 Float
12 UV lamp
13 Handle for removing the water tank
14 SecoSan® Stick 10 (optional accessory)
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
Before transporting the device, observe the following:
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Lift the device at the lower part.
• Empty the water tank.
• Empty the lower part.
• Do not use the power cable to drag the device.
• Check whether the upper part is correctly positioned on
the lower part.
After transporting the device, proceed as follows:
• Set up the device in an upright position after transport.

6 EN
humidifier B 7 E
Storage
Before storing the device, observe the following:
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Empty the water tank.
• Empty the lower part.
• Use a cloth to wipe all parts of the device dry.
• Clean the device according to the Maintenance chapter.
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
• Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and installation
Scope of delivery
• 1x Device
• 1x Adapter
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Only put up the device in an upright, stable position on firm
ground.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• Make sure that there are no moisture-sensitive objects in
the immediate vicinity of the mist nozzle, since water may
condense near the mist nozzle.
Filling the water tank
The water tank(3) should be filled with clear drinking water
before first use.
Note
Fill the device with clear drinking water only. The water
temperature must not exceed40°C.
Scented oil or other additives can damage the plastics
and the nebulizer membrane.
Info
If possible, change the water every3days to prevent
bacterial growth.
1. Open the lid with air outlet(1).
1
3
13
2. Fill clear drinking water(maximally40°C) up to the MAX
indication inside the water tank(3).
3. Insert the SecoSan® Stick (optional accessory)(14) into the
water tank(3).

EN 7
humidifier B 7 E
4. Now close the lid with air outlet(1).
1
3
13
Scent option
Additionally, the device offers the possibility to distribute a scent
during operation.
Note
Never put scented oil directly into the scented oil tank,
the water tank or on the membrane. Direct contact
with scented oil might cause damage to plastic
components or other device parts.
Use standard scented oil. Proceed as follows to use the scent
option:
üThe device is switched off and the power cable is
disconnected from the mains.
1. Remove the cover of the carbon filter(6) with the
integrated scented oil tank(15) from the device.
2. Put2 to3drops of scented oil onto the sponge in the
scented oil tank(15).
15 6
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
• Make sure that the air filter is installed before switching
the device on.
1. Insert the carbon filter(16) into the cover(6).
6 16
Connecting the power adapter
• Plug the power adapter cable into the device's mains
connection.
• Plug the power adapter into a properly fused mains socket.
7

8 EN
humidifier B 7 E
Operation
• Avoid open doors and windows.
• Make sure that there are no moisture-sensitive objects
located in the immediate vicinity of the mist nozzle, since
water may condense near the mist nozzle.
Operating elements
17
20
21
22
23
24
25
26
19
18
No. Designation Meaning
17 Segment display Indicates the current relative room
humidity.
Indicates the number of hours during
timer programming
Indicates error codes, see chapter
Errors and faults
18 Low water
levelLED
Illuminated if the water level is low
19 Timer LED Illuminated when the timer function is
activated
20 Timer button Switching the timer function on or off
21 Nebulizer intensity
button
Select nebulizer intensity
22 On/off button For switching the device on and off
23 Night mode
button
Switching night mode on or off
24 Automatic
operation button
Switching the automatic mode on or
off
25 Night mode LED Illuminated when night mode is
activated.
26 Automatic
operation LED
Illuminated when automatic mode is
activated
Switching the device on
1. Make sure that the water tank(3) has been filled with
drinking water.
2. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
3. Press the On/off switch(22).
ðThe segment display(17) indicates the last selected
nebulizer intensity.
ðThe device starts to humidify. Fine water mist leaves the
mist nozzle(2).
ðDuring manual humidification, the device indicates the
current relative humidity on the segment display in
percent.
Setting the nebulizer intensity
Info
If no operational input is made for40s, the segment
display(17) switches off.
The nebulizer intensity can be set to 3levels:
• Stage1: Low nebulizer intensity
• Stage 2: Medium nebulizer intensity
• Stage3: High nebulizer intensity
üThe device is switched on.
1. Press the Nebulizer intensity button(21).
ð"01" appears on the segment display(17) to indicate
the first stage.
2. Repeat the process for stage2 or3.
ðThe device now operates with the desired nebulizer
intensity.
Setting the operating mode
You can switch between the following operating modes:
• Automatic operation
• Night mode
• Manual humidification
Manual humidification
The nebulizer intensity can be set to stage1–3 in this operating
mode at any time(continuous humidification regardless of the
humidity level in the room).
Automatic operation
During automatic operation the device automatically regulates
the nebulizer intensity.
üThe device is switched on.
1. Press the automatic operation button(24) to activate
automatic operation.
ðThe automatic operationLED(26) appears on the
display.
ðAutomatic operation is now set.

EN 9
humidifier B 7 E
Night mode
The control element's sound output is deactivated during night
mode. The display switches off after approx.40s and only
switches back on when a button is pressed.
üThe device is switched on.
1. Press the night mode button(23) to activate the night
mode.
ðThe night modeindication(25) appears on the display.
ðNight mode is now activated.
2. Press the night mode button(23) again to activate the
night mode.
Timer function
The timer can be programmed in order to switch the device on
or off after a preset number of hours(1 to max.12). The timer
can be programmed in increments of 1hour.
Automatic switch-off
Please proceed as follows to programme automatic switch-off:
üThe device is switched on.
1. Press the timer button(20) until the desired number of
hours is displayed.
2. Wait a moment until the number of hours stops flashing.
ðThe timer setting equals the desired number of hours.
ðThe current room humidity is displayed again.
ðThe device switches off after the set period of time.
Notes regarding automatic switch-off:
• Pressing the On/off button(22) deactivates the automatic
switch-off function.
Automatic switch-on
Please proceed as follows to programme automatic switch-on:
üThe device is now in standby mode.
1. Press the timer button(20) until the desired number of
hours is displayed.
2. Wait a moment until the number of hours stops flashing.
ðThe timer setting equals the desired number of hours.
ðThe display switches off after a few seconds.
ðThe device switches on after the selected time has
elapsed.
Notes regarding automatic switch-on:
• Pressing the On/offbutton(22) deactivates the automatic
switch-on function.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Empty the water tank.
• Empty the lower part.
• Use a cloth to wipe all parts of the device dry.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Transport and storage
chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Designation Article number
SecoSan® Stick10 6.100.004.110

10 EN
humidifier B 7 E
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
• Check the power connection.
• Check the power cable and mains plug for damage.
• Check the on-site fusing.
• Check whether the water tank indicator light is illuminated.
The water tank might be empty and need refilling.
• Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of mist:
• Check whether the water tank indicator light is illuminated.
The water tank might be empty and need refilling.
• Check the valve in the water tank lid. The valve must be
able to move freely. Clean the water tank if required.
• Check the float in the lower part of the device. The float
should be able to move freely.
• Check the air filter for dirt. Clean the air filter if required.
• Check the nebulizer intensity setting and increase it if
required.
• Check the nebulizer membrane in the lower part of the
device for dirt and clean it if required.
The water tank is full, but the device indicates an empty
water tank:
• Heavy deposits on the filter cartridge may prevent the
water from flowing from the water tank into the device.
This can occur if the device has been out of use for a long
time. Rinse the filter cartridge with clear water and, if
required, carefully clean the filter at the filter cartridge.
• Check the valve in the water tank lid. The valve must be
able to move freely. Clean the water tank if required.
Water is leaking:
• Check whether the device is set up in a stable and upright
position.
• Check the water level in the lower part of the device. The
water level might be too high and water is discharged via
the overflow.
• Check the valve in the water tank lid. The valve must be
able to move freely. Clean the water tank if required.
• Check the float in the lower part of the device. The float
should be able to move freely. It may block and cause
water to be discharged via the overflow.
• Check the device for leaks.
The water mist has a peculiar smell:
• The device is new. Remove and rinse the water tank. Let
the open water tank air for some hours.
• Check the water tank. There may be stale or dirty water in
the water tank. Rinse the water tank and fill it with clear
drinking water.
Condensate forms on the device:
• The air circulation in the room is insufficient. If necessary,
reduce the nebulizer intensity and provide better air
circulation (e.g. using a fan).
• The room's humidity level is quite high. This makes it
difficult for the mist to distribute and leads to water
condensing on the device. If necessary, reduce the
nebulizer intensity or switch off the device.
The device is loud or vibrates heavily:
• Check whether the device is set up in a stable and upright
position.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Table of faults
The following faults can be displayed on the control panel(5):
Error Meaning
The automatic
operationLED(26) flashes and
the segment display(17)
indicates"- -".
There is a fault at the
temperature or humidity
sensor.
The low water levelLED (18)
flashes.
The water tank is empty or not
installed correctly.

EN 11
humidifier B 7 E
Maintenance Maintenance intervals
Maintenance and care interval before
every start-
up
as needed every
3days
at least
every
2 weeks
at least
every
4 weeks
at least
every
6 months
at least
annually
Cleaning the water tank X
Check air inlets and outlets for
dirt and foreign objects and clean
ifnecessary
X X
Clean the exterior X X
Visually check the inside of the
device for dirt
X X
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
X X
Replace the air filter X
Check for damage X
Check the attachment screws X X
Test run X
Maintenance and care log
Device type: ............................................. Device number: ....................................
Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Cleaning the water tank
Check air inlets and outlets for dirt
and foreign objects and clean
ifnecessary
Clean the exterior
Visually check the inside of the
device for dirt
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
1. Date: ...................................
Signature: ................................
2. Date: ....................................
Signature: .................................
3. Date: ....................................
Signature: .................................
4. Date: ....................................
Signature: .................................
5. Date: ...................................
Signature: ................................
6. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
9. Date: ...................................
Signature: ................................
10. Date: ..................................
Signature: .................................
11. Date: ..................................
Signature: .................................
12. Date: ..................................
Signature: .................................
13. Date: .................................
Signature: ................................
14. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................

12 EN
humidifier B 7 E
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Switch the device off.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Cleaning the water tank
Info
Use the SecoSan®Stick by Trotec to provide protection
from germs in the water. The SecoSan®Stick prevents
the reproduction of germs by means of silver ions. Due
to the special, antimicrobial surface, the silver ions are
emitted to the immediate proximity of bacteria and
germs. This way, microbial growth can be effectively
prevented– at the same time, the water remains pure
and uncontaminated. The dosage of the SecoSan ®
Stick is carried out automatically.
Info
Clean the nebulizer membrane, air outlet, water tank
and the water lines as often as possible.
The water tank should be cleaned every3days if actively used.
Use household vinegar as cleaning/descaling agent. Observe the
manufacturer's specifications and hazard warnings of the
descaling agent. Before a longer period of non-use or storage
the water tank should be drained.
1. Remove the cover(1).
2. Remove the water tank(3) from the bottom section(4)
holding it by the handle(13).
Please note that there may still be residual water left in the
bottom section if the device was used beforehand.
1
3
13
3. Clean the water tank with a standard cleaning agent to
remove limescale deposits.
4. Allow the water tank(3) to dry.
5. Fill the water tank(3) with fresh drinking water.
6. Place the water tank(3) back on the bottom section(4)
again and fold the handle(13) back to the side. Now close
the lid with mist outlet(1).
1
3
13

EN 13
humidifier B 7 E
Cleaning the nebulizer membrane
Depending on the hardness of the drinking water used, deposits
may form on the nebulizer membrane over time. These could
affect the nebulizer performance. Therefore, the nebulizer
membrane should be cleaned on a regular basis.
To do so, please proceed as follows:
1. Remove the top section with water tank(3) as described in
Cleaning the water tank.
2. Remove any residual water from the inside of the device.
3. Wet the nebulizer membrane(10) with household
vinegar(descaling agent).
4. Let the descaling agent act for approx.2 to 5min.
5. Remove the deposits from the nebulizer membrane(10)
using the cotton bud.
10
6. Rinse the inside of the device with clear water.
7. Refit the water tank(3) as described in Cleaning the water
tank.
Cleaning the air filter
The air filter should be cleaned or replaced in case of heavy
soiling.
1. Lightly push against the cover of the carbon filter(6).
ðThe cover of the carbon filter(6) is unlocked from the
bottom section(4).
2. Carefully remove the cover of the filter(6) from the bottom
section(4).
6 16
4
3. Clean or replace the carbon filter(airfilter)(16).
4. Insert the carbon filter(airfilter)(16) into the cover(6).
5. Slide the cover(6) into the bottom section(4).
6 16

14 EN
humidifier B 7 E
Clean the water filter
The water filter should be cleaned in case of heavy soiling.
1. Carefully remove the cover of the water filter(8) from the
water tank(3).
8
27
2. Clean or replace the water filter(27).
3. Position the water filter(27) inside the cover of the water
filter(8).
4. Refasten the cover of the water filter in the water tank(3).
Cleaning the scented oil tank
The scented oil tank should be cleaned on a regular basis. This
tank is integrated in the cover of the carbon filter.
1. Lightly push against the cover of the carbon filter(6) so
that the cover is unlocked from the housing.
2. Carefully remove the cover of the carbon filter(6) from the
device.
3. Now clean the area around the scented oil tank(15).
6
15
4. Use a cloth to wipe the scented oil tank(15) dry.
5. Slide the cover of the carbon filter(6) into the bottom
section(4) again.
Activities required after maintenance
If you want to continue using the device:
• Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
• Store the device according to the Transport and storage
chapter.

EN 15
humidifier B 7 E
Technical annex
Technical data
Parameter Value
Model B 7 E
Nebulizer performance 300ml/h
Runtime 16 h
Temperature of surrounding
conditions
+5°C to +40°C
Power consumption 24W
Mains connection adapter 100 V – 240 V / 50 Hz – 60 Hz
Output voltage of adapter 24V
Output current of adapter 1A
Nominal current consumption 0.6A
Plug type CEE 7/16
Cable length 1.45 m
Sound pressure level(1m
distance)
38 dB (A)
Water tank capacity 5l
Dimensions (lengthx widthx
height)
195 x 195 x 385 mm
Weight 2kg
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the
website https://hub.trotec.com/?id=45090. Otherwise, please
contact an official recycling centre for electronic and electrical
equipment authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
www.trotec.com
Table of contents
Other Trotec Humidifier manuals

Trotec
Trotec B 500 User manual

Trotec
Trotec AW 20 S User manual

Trotec
Trotec B 200 User manual

Trotec
Trotec B 200 User manual

Trotec
Trotec B 1 E User manual

Trotec
Trotec B6E User manual

Trotec
Trotec B 2 E User manual

Trotec
Trotec B 400 User manual

Trotec
Trotec AW 10 S User manual

Trotec
Trotec B 25 E User manual