Trotec BZ06 User manual

TRT-BA-BZ06-TC2019-26-001-EN
BZ06
EN
OPERATING MANUAL
CLIMATE MONITORING
STATION

2 EN
climate monitoring station BZ06
Table of contents
Notes regarding the operating manual.................................2
Safety .....................................................................................2
Information about the device................................................3
Transport and storage...........................................................4
Operation ...............................................................................4
Maintenance and repair ........................................................7
Disposal .................................................................................7
Notes regarding the operating manual
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information
(e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
operating manual must be observed.
You can download the current version of the operating manual
and the EU declaration of conformity via the following link:
BZ06
https://hub.trotec.com/?id=43554
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Do not immerse the device in water. Do not allow liquids to
penetrate into the device.
• The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.
• Protect the device from permanent direct sunlight.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Do not open the device.
• Observe the storage and operating conditions as given in
the Technical data chapter.

EN 3
climate monitoring station BZ06
Intended use
Only use the device to measure the indoor air temperature and
humidity. Observe and comply with the technical data.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.
Improper use
Do not use the device out of doors.
Do not use the device in potentially explosive areas.
Any unauthorised changes, modifications or alterations to the
device are forbidden.
Personnel qualifications
People who use this device must:
• have read and understood the operating manual, especially
the Safety chapter.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Note
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
Note
Do not use abrasive cleaners or solvents to clean the
device.
Information about the device
Device description
The climate monitoring station is a battery-powered measuring
device indicating the current indoor climate.
It comes with the following functional properties and equipment
features:
• Simultaneous indication of room temperature, weather
forecast, humidity level, date, weekday and time or
calendar year
• Alarm with snooze function
• Hourly time signal
• Indication of recorded minimum and maximum values for
temperature and relative humidity
• Switching option between °C and °F
Device depiction
AM PM YEAR
TEMP HUMIMIN
MAX
MODE
UP
SNZ
SET
13
4
6
7
2
8
11
9
10
5
No. Designation
1 °C/ °F indication
2 Weather forecast indication
3 Relative humidity indication
4 Indication of date and weekday/ alarm mode
5 Indication of time/ alarm time/ calendar year
6UPbutton
7SETbutton
8SNZbutton (snooze)
9MODEbutton
10 Opening with RESETbutton
11 Battery compartment

4 EN
climate monitoring station BZ06
Technical data
Parameter Value
Model BZ06
Article number 3.510.205.016
Weight
(incl. batteries) approx. 81g
Dimensions
(heightx widthx
depth)
approx. 134mmx 60mmx 44mm
Display LCD (monochrome)
Power supply 1battery of typeAAA, 1.5V
Relative humidity
Measuring range 20%RH to 99%RH
Accuracy ±5 %RH
Resolution 1%
Air temperature
Measuring range -10°C to 50 °C or 14°F to 122 °F
Accuracy ±1 °C or ±1.8 °F
Measuring range
resolution 1 °C / °F
Ambient conditions
Operation -10°C to 50°C or 14°F to 122°F
and 90%RH (non-condensing)
Storage -10°C to 50°C or 14°F to 122°F
and 90%RH (non-condensing)
Scope of delivery
• 1x Device BZ06
• 1x Battery, typeAAA, 1.5V
• 1 x Quick guide
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
When transporting the device, ensure dry conditions and and
protect the device from external influences e.g. by using a
suitable bag.
Storage
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• protected from dust and direct sunlight
• The storage temperature is the same as the range given in
the Technical data chapter.
• Remove the batteries from the device.
Operation
Inserting the battery
Prior to first use, insert a battery (typeAAA, 1,5V) into the
device. To do so, please proceed as follows:
1. Open the battery compartment(11) at the bottom of the
device.
2. Insert the batteries with correct polarity(+/-).
3. Close the battery compartment.
ðThe display will be activated and an acoustic signal is
emitted.

EN 5
climate monitoring station BZ06
Switching between the indication of time, alarm time and
calendar year
By pressing the MODEbutton(9) you can switch the
indication(5) from the time(time mode) to the alarm time(alarm
mode) and then to the indication of the calendar year(date
mode) by pressing the MODEbutton(9) once more.
AM PM YEAR
D
M
AM PM YEAR
AM PM YEAR
D
M
12 14
13
No. Designation
12 Time mode
13 Alarm mode
14 Date mode
Setting the time and time format
Please proceed as follows to set the time and the time format:
üYou have selected the time mode(12).
1. Press the SETbutton(7) for approx. 3seconds.
ðThe time format(12hr/ 24hr) flashes on the display.
2. Use the UPbutton(6) to set the desired time format.
3. Once the time format has been set correctly, press the
SETbutton(7) once more to switch to the hour display.
ðThe hour display starts flashing.
4. Use the UPbutton(6) to adjust the hourdisplay correctly.
Keep the button pressed to adjust the value at a faster
pace.
5. Once the hourdisplay has been set correctly, press the
SETbutton(7) once more to switch to the minute display.
ðThe minute display starts flashing.
6. Use the UPbutton(6) to adjust the minute display
correctly. Keep the button pressed to adjust the value at a
faster pace.
7. Once the minute display has been set correctly, press the
MODEbutton(9) to exit the mode.
Setting the alarm time
Please proceed as follows to set the alarm time:
1. Switch over into the alarm mode(13) by pressing the
MODEbutton(9).
ðThe indication(4) switches over into alarm mode and
displays AL, the indication(5) displays the alarm time.
2. Press the SETbutton(7) for approx. 3seconds.
ðThe hour display starts flashing.
3. Use the UPbutton(6) to adjust the hourdisplay correctly.
Keep the button pressed to adjust the value at a faster
pace.
4. Once the hourdisplay has been set correctly, press the
SETbutton(7) once more to switch to the minute display.
ðThe minute display starts flashing.
5. Use the UPbutton(6) to adjust the minute display
correctly. Keep the button pressed to adjust the value at a
faster pace.
6. Once the minute display has been set correctly, press the
MODEbutton(9) to exit the mode.
Setting the date and weekday
Please proceed as follows to set the date and the weekday:
1. Switch over into the date mode(14) by pressing the
MODEbutton(9).
ðThe indication(4) displays the month, day and weekday,
the indication(5) displays the calendar year.
2. Press the SETbutton(7) for approx. 3seconds.
ðThe calendar year flashes on the display.
3. Use the UPbutton(6) to adjust the displayed calendar year
correctly. Keep the button pressed to adjust the value at a
faster pace.
4. Once the displayed calendar year has been set correctly,
press the SETbutton(7) once more to switch to the month
display.
ðThe month display(M) starts flashing.
5. Use the UPbutton(6) to adjust the month display correctly.
Keep the button pressed to adjust the value at a faster
pace.
6. Once the month display has been set correctly, press the
SETbutton(7) once more to switch to the day display.
ðThe daydisplay(D) starts flashing.
7. Use the UPbutton(6) to adjust the daydisplay correctly.
Keep the button pressed to adjust the value at a faster
pace.
ðThe weekday will automatically be set to the correct
day.
8. Once the daydisplay has been set correctly, press the
MODEbutton(9) to exit the mode.

6 EN
climate monitoring station BZ06
De-/activating the alarm function and the hourly time signal
1. Switch over into the alarm mode(13) by pressing the
MODEbutton(9).
ðThe indication(4) switches over into alarm mode and
displays AL, the indication(5) displays the alarm time.
2. Press the UPbutton(6) to activate the alarm function.
ðThe alarm icon(15) will be indicated on the display.
3. By pressing the UPbutton(6) once more you can now in
turn select the following functions:
• Hourly time signal activated instead of the alarm function.
The icon for the hourly alarm signal(16) will be displayed
and an acoustic signal is emitted every full hour.
• Both the alarm function and the hourly time signal are
activated. Both icons(15, 16) will be displayed.
• Both the alarm function and the hourly time signal are
deactivated. None of the two icons(15, 16) will be
displayed.
AM PM YEAR
15
17
16
No. Designation
15 Alarm function activated icon
16 Hourly time signal activated icon
17 Snooze function activated icon
Turning off the alarm
When the acoustic alarm signal is emitted, you can turn it off by
pressing any of the buttons (other than SNZ(8)).
Note:
The alarm will stop automatically after 1minute if no button is
pressed.
Snooze function
The device comes equipped with a snooze function enabling you
to turn the alarm off for the time being. The acoustic alarm
signal will be emitted once more after approx. 4minutes:
1. Press the SNZbutton(8) when you hear the alarm.
ðThe alarm will stop and the icon for the snooze
function(17) starts flashing.
2. After approx. 4minutes, when the acoustic alarm signal is
emitted once more, you can use the snooze function again
by pressingSNZ(8).
3. To deactivate the active snooze function, simply press any
other button thanSNZ(8).
ðThe icon for the snooze function(17) will stop flashing
and the snooze function is deactivated.
Weather forecast
The device has an indication for the weather forecast(2)
displayed by foursymbols:
18
20
19
21
No. Designation
18 Sunny symbol
19 Partly cloudy symbol
20 Overcast symbol
21 Rain symbol
Info
The device is not fitted with a sensor for atmospheric
pressure. The weather forecast is based on the
changing relative humidity level. If the relative humidity
level changes by more than ±5% within one hour, the
indication will be adjusted accordingly.

EN 7
climate monitoring station BZ06
Indication of minimum and maximum values
The device saves the minimum and maximum values for
temperature and relative humidity. These values can be
displayed by pressing the UPbutton(6):
1. Briefly press the UPbutton(6) once to display the
maximum values.
ðThe maximum values will be displayed along with the
MAXsymbol.
2. Press the UPbutton(6) again to display the minimum
values.
ðThe minimum values will be displayed along with the
MINsymbol.
3. Press the UPbutton(6) once more to exit the mode.
Switching the temperature indication between °C and °F
Briefly press the SETbutton(7) to switch the indicated
temperature unit from degrees Celsius to degrees Fahrenheit or
vice versa.
Info
Switching between °C and °F can only be
accomplished in the time mode.
Resetting the system
You can reset the system to its initial configuration. To do so,
use a pointed object to press the RESETbutton in the
opening(10).
Maintenance and repair
Battery change
A battery change is required when the display is no longer or
only partly visible.
See chapter Operation.
Cleaning
Clean the device with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Do not use any
sprays, solvents, alcohol-based cleaning agents or abrasive
cleaners, but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
www.trotec.com
Table of contents
Other Trotec Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

Platinum CCTV
Platinum CCTV PT-BF5421-T Installation and setup

ero electronic
ero electronic LFS user manual

Ropex
Ropex CIRUS UPT-640 operating instructions

DELTA DORE
DELTA DORE PACK TYBOX 5000 Instructions for use

CLIMASET
CLIMASET SDT Series user guide

Beacon
Beacon TC-W Series Wifi Connection Instructions

dixell
dixell XR530C Installing and operating insructions

Advanced Power technologies
Advanced Power technologies TTC-1000 instruction & operation manual

ascon
ascon M1 line manual

AGPtek
AGPtek TA4 instruction manual

Carbolite
Carbolite Type 301 operating instructions

Richter
Richter SAFERUN CMS-S Installation and operating manual