Truvox International VTVe User manual

TM
TRUVOX
INTERNATIONAL
---- A TACONY COMPANY ----
I
ORIGINAL INSTRUCTIONS
I
CAUTION - READ THESE INSTRUCTIONS BEFOREUSING THE MACHINE
VTVe
Commercial Vacuum Cleaner
USERMANUAL EN
MANUEL D'UTILISATION FR
03-8400-0000
(E
Issue 1 02-17

IMPORTANT
BEFORE USE READ THESE INSTRUCTIONS AND RETAIN FOR FUTURE REFERENCE
Introduction
The following instructions contain important information about
the machine and safety advice for the operator. Equipment
must be operated, serviced and maintained in accordance with
the manufacturer's instructions. If in doubt contact the supplier
of your machine.
Read all instructions before using the
machine
Product information
This vacuum cleaner is designed for the collection of dust in
indoor areas. This machine is for indoor use only. The machine
is intended for commercial use, for example in hotels, schools,
hospitals, factories, shops, offices, rental businesses and other
than normal housekeeping purposes.
Technical Specifications
Model VTVe
Voltage AC (-)1
VI
Hz
220-240 50/60
Frequency
Construction class II
Protectionclass IP 20
Vacuum motor power W SOO
Vacuum kPa 24.S
Productivity rate
m2/h
232
Airflow rate
lis
30.5
Filtration H13
Capacity I 11.5
Sound pressure level dB(A) 65
Sound power level dB(A) 72
Dimensions (LxWx 34 x 33 x 37
H) cm
Weight kg 6
Hose length m 2
Cable length m 12
Warranty 1 year
• Noiselevelsmeasuredatadistanceof1meterfrommachineand
1.6metresabovefloor,whenwashinga hardfloor.Measurements
recordedusinga handheldmeter.
• Hand-armvibrationdoesnotexceed2.5m/s>,wheninnormal
use,oncarpetedorhardsurfaces.
• Abovedimensionsareapprox.Sincethecompany'spolicyisto
continuouslyimprovetheproduct,therecouldbechangeswithout
priornotice.
ECDECLARATIONOFCONFORMITY
MachineType:Commercialvacuumcleaner
Model:VTVe
ThismachineisinconformitywiththefollowingEUdirectives:
• MachineryDirective: 2006/42/EC
• TheEMCDirective: 2014/30/EU
• ECOLabellingDirective: 2009/125/EC,
2013/666/EU
Appliedharmonisedstandards:
EN60335-1,EN60335-2-69,EN55014-1,EN55014-2,EN610003-
2,EN610003-3,EN62233
TruvoxInternationalLimited
H.~·
UnitC(East),HamiltonBusinessPark,
ManatonWay,BotleyRoad, MalcolmEneas
HedgeEnd,Southampton OperationsManager
S0302JR,UK Southampton,06/1 0/2016
2
Waste Electrical
&
Electronic Equipment
(WEEE)
)t
-
Do not dispose of this device with unsorted waste.
Improper disposal may be harmful to the
environment and human health. Please refer to your
local waste authority for information on return and
collection systems in your area.
IMPORTANT SAFETY ADVICE
The safety information described in this manual provides basic
precautions and supplements standards in force in the country
where the machine is used.
This symbol warns the operator of hazards and unsafe
1'.
practices which could result in severe personal injury or
L.!.::l.
death.
I.\!
WARNING - to reduce the risk of injury, electric shock
L.!.::l.
or fire.
1. This machine must only be used for the manufacturer's
approved application as described inthis manual.
2. Operators must be fully trained in the use of the machine in
accordance with these instructions, able to perform regular
user maintenance and the correct selection of accessories.
3. Only genuine accessories and spare parts provided with
the machine or those approved by the manufacturer should
be used. All repairs must be performed by a qualified
service agent.
4. Do not use without filters or dust bags in place.
5. Do not modify the machine from its original design.
6. This machine is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the machine by a person responsible for their safety.
7. Keep children and unauthorised persons away from the
machinewhen in use. Do not use as a toy.
S. The machine must be kept clean and in good condition with
regular inspections of the power supply cord and plug for
signs of any damage. If any parts are damaged they shall
only be replaced by an approved part by the manufacturer,
its service agent or a similar qualified person in order to
avoid a hazard.
&@
iSf~
ELECTRICAL HAZARD
9. CAUTION - This machine is for dry indoor use only and
should not be used or stored outdoors in wet conditions.
10.DO NOT use where hazardousdust is present.
11.DO NOT use in an explosive atmosphere.
12.DO NOT pick up or use near flammable or combustible
fluids, dusts or vapours.
13.DO NOT use to pick up moisture or any liquids.
14.DO NOT use to clean up any burning or lighted materials
such as cigarettes, matches, ashes or other combustible
objects.
15.DO NOT use the appliance to vacuum tiny particles like
cement or plaster dust as this will shorten life of the motors.
16.Take care when using a machine near the top of stairs to
avoid overbalancing.
17.DO NOT put any object into openings. DO NOT use with
any opening blocked; keep free of dust, debris and anything
that may reduce airflow.
1S.Keep hair, loose clothing, hands, feet and all other parts of
the body away from openings and moving parts.
19.This machine should always be connected to a fully earthed
power supply of the right voltage and frequency.
02-17

20. DO NOT leave the machine connected to the electricity
supply when not in use; always remove the plug from the
socket outlet. DO NOT leave machine running unattended.
21. Switch off the machine before removing the plug.
22. When unplugging, pull the plug, not the supply cord.
23. The plug of the power supply cord must be removed from
the socket-outlet when not in use and before commencing
cleaning of the machine or undertaking maintenance
operations.
24. DO NOT pull or carry by the supply cord. DO NOT use cord
as a handle, close door on cord or pull cord around sharp
edges or corners.
25. WARNING: Keep the power supply cord clear of moving
parts. During operation hazard may occur when running
the machine over the power supply cord.
26. DO NOT kink or twist the power cord and keep cord away
from heated surfaces.
27. DO NOT operate switches or touch the mains plug with wet
hands as this may cause electric shock.
28. The power supply cord plus any extension leads should not
exceed 30 metres in total. The cross section of an
extension cable wiring must be at least 2.5mm
2.
Transporting the machine
Incorrect lifting techniques may result in personal injury. We
advise that the manual handling regulations are followed.
Carefully wrap the power cord and store in dry indoor location.
Do not expose the machine to rain or moisture. Lift the
machine by the carrying handle to transport.
Maintenance
J.\
WARNING - Before undertaking maintenance
~ operations or adjustments switch off machine and
• unplug from the electricity supply.
The machine requires minimum maintenance apart from the
following daily checks by the operator.
• Supply cord - Regularly inspect sheath, plug and cord
anchorage for damage or loose connection.
• Body of the vacuum - Clean with a damp cloth.
• Vacuum filter - Check the vacuum filters, clean and replace
as appropriate.
• Hose, wand and vacuum accessories - Check and remove
any debris or lint build-up from the head.
IMPORTANT - All other servicing and repairs should only be
performed by a Truvox engineer or Authorised Service Agent.
IMPORTANT - Should the machine fail to operate please refer
to the fault diagnosis section in the back of this instruction
manual. If the problem / remedy is not listed please contact
Truvox Customer Service Department for rapid attention.
UK Model only
The cord is equipped with a 13 amp fuse. If replacing fuse, use
a 13 amp fuse confirming to 8S1362. Do not use the machine
if fuse cover is missing.
3
After sales service
Truvox machines are high quality machines that have been
tested for safety by authorised technicians. It is always
apparent that after longer working periods, electrical and
mechanical components will show signs of wear and tear or
ageing. To maintain operational safety and reliability the
following service interval has been defined: Every year or after
250 hours. Under extreme or specialised conditions and/or
insufficient maintenance, shorter maintenance intervals are
necessary. Use only original Truvox spare parts. Use of other
spare parts will invalidate all warranty and liability claims.
Should you require after sales service please contact the
supplier from whom you purchased the machine, who will
arrange service. Repairs and servicing of Truvox products
should only be performed by trained staff. Improper repairs can
cause considerable danger to the user.
Guarantee
Your product is guaranteed for one year from the date of
original purchase, or hire purchase, against defects in materials
or workmanship during manufacture. Within the guarantee
period we undertake at our discretion, to repair or replace free
of charge to the purchaser, any part found to be defective,
subject to the following conditions:
CONDITIONS
1. Claims made under the terms of the guarantee must be
supported by the original invoice/bill of sale issued at the
time of sale, or the machine Serial No.
2. For claims under this guarantee contact the supplier from
whom you purchased the product who will arrange the
appropriate action. Do not initially return the product as this
could result in transit damage.
3. Neither Truvox nor its distributor shall be liable for any
incidentalor consequential loss.
4. This guarantee is governed by the laws of England.
5. This guarantee does not cover any of the following:
• Periodic maintenance, and repair or replacement of
parts due to normalwear and tear.
• Damage caused by accident, misuse or neglect, or
the fitting of other than genuine Truvox parts.
• Defects in other than genuine Truvox parts, or repairs,
modifications or adjustments performed by other than
a Truvox service engineer or authorised service
agent.
• Costs and risks of transport relating directly or
indirectly to the guarantee of this product.
• Consumable items such as, brushes, drive discs,
filters and vacuum skirts.
• This guarantee does not affect your statutory rights, or your
rights against the supplier arising from their sales or
purchase contract. Truvox International Limited policy is one
of continual product development and we reserve the right to
alter specifications without prior notice.
02-17

Recommended Spares
&
Accessories
Part No. Item
1903627900013 HEPA 13 Filter
05-4739-0000 Pack of 12 microfibre dust bags
1903108000002 Hose
1903408500001 Telescopic wand
HB15C Floortool
1903304900001 Tool Kit, Dusting Brush, Crevice Tool
Fault diagnosis
.t.\
WARNING - Before undertaking maintenance operations or adjustments switch off machine
~ and unplug from the electricity supply.
The following simple checks may be performed by the operator:
Trouble Reason Remedy
Machine not working • Lackof voltage/electrical supply • Check fuse
*,
supply cord, plug and
socket outlet
Loss of suction • Bag full • Replace bag
• Blocked hose or wand • Removeobstruction
• Motor not workinq • Contact supplier
Motor is not running • Broken switch • Contact supplier
• Defective power cord
• Defective motor
*If the fuse blows several times, the machine should be checked by an authorises Service Agent
PLEASE REFER TO THE BACK OF THE MANUAL FOR THE PICTORIAL
INSTRUCTIONS
4
02·17

IMPORTANT
VEUILLEZ LIRE CES INSTRUCTIONS ET LES CONSERVER POUR REFERENCE FUTURE
Informations generales
Ce manuel est fourni avec chaque nouveau modele et contient
des informations importantes sur la machine et des avis de
securite pour l'operateur. l.'equipernent doit fonctionner, etre
en service et entretenu conforrnernent aux instructions du
fabricant. Encas de doute, contactez votre fournisseur.
Lire attentivement toutes
instructions avant toute utilisation.
Product information
Ces aspirateurs sont concus pour collecter la poussiere en
interieur, Cette appareil n'est reserve qu'a une utilisation en
interieur., Cette machine est destinee a I'utilisation
commerciale, par exemples hotels, eccles, hopitaux, usines,
magasins, bureaux, societes de
locationou utilisation domestique.
Technical Specifications
Model Valet Tub Vac
Tension alternative (-)
I
Frequence
VI
Hz
220-240 50/60
Classe de construction II
Classification de protection IP 20
Puissancedu moteur W 800
Depression
a
la colonne d'eau kPa 24.8
Productivite
m2/h
232
Debitd'air
I/mm
30.5
Etapesde filtration H13
Capacite du sac poussieres I 11.5
Niveau sonore dB(A) 65
Niveau de puissance sonore dB(A) 72
Dimensions (L x W x H) cm 34 x 33 x 37
Poids kg 6
Longueur du flexible m 2
Longueur du cable m 12
Warranty 1 an
• Lesniveauxsonoressontrnasuras
a
unedistanced'1metrepar
rapport
a
lamachineetde1,6metresaudessusdusolpendantIe
lavaged'unrevetementduroLesmesuressontenregistreesparun
appareilportatif.
• Valeurdevibrationsbras-mainnedspassepas2,5
m/s2
lorsd'une
utilisationsurlesmoquettesetsolsdurs.
• Lesdimensionsci-dessussontapproximatives.Truvoxpoursuivant
unepolitiqued'arneliorationcontinue,deschangementspeuventetre
apportsssansavisprealable,
DECLARATIONDECONFORMITECE
Typedemachine:Aspirateurscommerciaux
Modele:VTVe/EURO
CettemachineestconformeauxdirectivesdeI'Unioneuropsenne
suivantes:
•Directivesurlesmachines 2006/42/EC
•DirectiveCME 2014/30/EU
•Directivesd'Ecolabslisation 2009/125/EC
20 13/666/E U
Normesharrnonisaesappliquess
EN60335·1,EN60335·2·69,EN55014·1,EN55014·2,
EN61000·3·2,EN61000·3·3,EN62233
TruvoxInternationalLimited ~.~.
UnitC(East),HamiltonBusinessPark,
ManatonWay,BotleyRoad, MalcolmEneas
HedgeEnd,Southampton OperationsManager
S0302JR,UK Southampton,06/10/2016
5
Dechets d'Equipements Electriques et Electroniques
(DEEE)Ne pas jeter cet appareil avec les dechets non
recyclables. Toute elimination lnappropriee peut
etre nocive pour I'environnement et la
sante humaine.
S'adresser aux agences locales de traitement des
dechets pour obtenir des informations sur les
systemes de retour et de collecte dans votre
les
-
secteur.
IMPORTANTES CONSIGNES DE SECURITE
les consignes de securite decrites dans ce manuel proviennent
des consignes de securite standards en vigueur dans Ie pays
ou I'appareil est utilise,
1.\
Ce symbole alerte I'utilisateur sur les dangers
~ eventuels et les pratiques imprudentes pouvant
entrainer des blessures graves voire la mort.
I.\!
ATTENTION - Afin de reduire Ie risque d'incendie,
~ electrocution ou de blessure:
1. Cet appareil dans les conditions et destinations
preconisees par la fabricant comme decrites dans ce
manuel.
2. Afin de pouvoir proceder
a
une utilisation de la machine
conforme
a
ces instructions, les operateurs doivent avoir
suivis une formation complete, etre capables de realiser les
operations d'entretien ainsi que de proceder au choix
correct des accessoires.
3. Seuls les accessoires et pieces detachees d'origine prevus
pour cette machine ou approuves par Ie fabricant doivent
etre utilises. Toute reparation doit etre eftectuee par un
agent agree par Iefabricant.
4. Ne pas utiliser sans filtres ou sac
a
poussiere.
5. Ne pas modifier I'appareil de sa configuration initiale.
6. Cet appareil n'est pas concu pour etre utilise par des
personnes (et notamment des enfants)
a
capacites
motrices, sensorielles ou intellectuelles reduites, ou
manquant d'experience et de connaissances, excepte s'ils
sont supervises ou formes
a
I'utilisation de I'appareil par
une personne responsable de leur securite,
7. Tenir les enfants et toutes les personnes non autorisees
a
distance de la machine quand celle-ci est en
fonctionnement. Ne pas laisser I'appareil etre utilise
comme un jouet.
8. La machine doit etre nettoyee requlierernent et qardee
dans les meilleurs conditions de fonctionnement par une
inspection requliere du cable d'alimentation et
d'interrupteur. Toute piece detectueuse doit etre rernplacee
par une piece d'origine aqreee par la fabricant, Ie
reparateur agree ou toute personne habllitee
a
intervenir
sur I'appareil.
&@
iSf~
RISQUE ELECTRIQUE
9. CAUTION - Cet aspirateur doit etre utilise uniquement en
interieur et on ne doit pas s'en servir ni Ie stocker
a
l'exterieur ni I'utiliserdans des conditions humides
10.Ne pas utiliser en presence de poussieres presentant un
danger.
11.Ne pas utiliser dans des endroits presentant des risques
d'explosion.
12.NE PAS aspirer ou utiliser
a
proxirnite de liquides,
poussieres ou vapeurs inflammable.
13.Ne pas utiliser I'aspirateur pour collecter de la
condensation, tous autres liquides ou de poussieres
presentant un danger.
14.Ne pas utiliser I'appareil
a
vide pour ramasser des
cigarettes allurnees, des cendres chaudes ou autres objets
combustibles. 02·17

15. Ne pas utiliser I'appareil
a
vide pour ramasser des
particules de ciment ou de platte, cela reduire la duree de
vie du moteur.
16.Prendre garde d'eviter les desequillbres lors de I'utilisation
de la machine
a
proxirnite de la partie haute des escaliers.
17.NE PAS introduire d'objets dans les ouvertures. NE PAS
utiliser en cas d'obturation d'une ouverture. Eliminer tout
amas de poussiere, debris ou autre qui pourrait reduire Ie
flux d'air.
18.Eloigner les cheveux, les veternents amples, les pieds et
autres parties du corps des ouvertures et parties mobiles
de I'appareil.
19.Ne pas laisser I'aspirateur branche lorsque vous ne
I'utilisez pas, debranchez toujours la fiche de la prise de
courant. Ne laissez pas I'aspirateur fonctionner sans
surveillance.
20. Eteignez la machine avant de Iedebrancher,
21. Pour debrancher la machine tirer sur la prise et non sur Ie
cordon.
22. La prise electrique doit etre debranchee apres avoir arrete
Ie moteur de I'appareil , et avant toute intervention
d'entretien ou de reparation.
23. Ne tirer pas et ne transporter pas I'appareil par Ie cordon
d'alimentation. N'utilisez pas Ie cordon comme poiqnee, ne
coincez pas Ie cordon lorsque vous fermez une porte, ne
frottez pas Iecordon sur des angles de murs ou des arretes
vives.
24.ATTENTION : Tenir Ie cable d'alimentation eloiqne des
pieces mobiles. Durant Ie fonctionnement, il peut etre
dangereux de faire passer la machine sur Ie cordon
d'alimentation.
25. NE PAS tordre ou vriller Iecable et Ietenir eloiqne de toute
source de chaleur.
26. Ne pas manoeuvrer les commutateurs et ne pas toucher la
prise electrique avec des mains mouillees car ceci peut
provoquer une electrocution.
27. Le fil electrique et sa rallonge ne doivent pas depasser 30
m au total. Tout prolongateur doit avoir au minimum une
section de 2,5 rnrn-.
Transporter la machine
Une technique de transport incorrecte peut generer des
blessures musculaires. Nous conseillons de suivre les
consignes de ce manuel. Ranger correctement Ie cable et
stocker I'appareil dans un endroit sec. Ne pas exposer
I'appareil
a
la pluie ou
a
l'hurnidite. Lever I'appareil par la
poiqnee prevue
a
cet effet.
Entretien
Ii\. ATTENTION - Avant toute modification ou
~ changement d'accessoires, etelqnez I'aspirateur
• et debranchez Ie du courant
electrlque,
La machine necessite un minimum d'entretien en dehors de la
verification eftectuee par l'operateur,
• Cordon d'alimentation - Inspecter requlierernent la gaine,
la prise et Iecordon pour y detecter les dommages ou les
connexions desserrees,
• Corps de I'aspirateur - Nettoyer avec un chiffon humide.
• Filtre aspirateur - Verifier les filtres, nettoyer et remplacer si
necessaire,
• Tuyau, manche et accessoires d'aspirateur - Verifier et
enlever les debris du suceur.
IMPORTANT - Toutes les autres operations de maintenance et
les reparations doivent uniquement etre entreprises par un
inqenieur Truvox ou un agent d'entretien agree. IMPORTANT-
En cas de defaillance de la machine, veuillez vous reporter
a
la
6
section diagnostic des pannes au dos de ce manuel
d'instruction. Si Ie problema et sa solution ne sont pas
repertories, veuillez contacter Ie service client Truvox qui
repondra rapidement
a
vos questions.
Service Apres Vente
Cet appareil est de haute qualite, teste en matiere de securite
par des techniciens agrees. II est logique qu'apres une longue
periode d'utilisation, les pieces electriques et rnecaniques
montrent des signes d'usure ou de faiblesse. Afin de garantir
une securite totale d'utilisation, les frequences de
remplacement suivantes ont ete definies : 1 fois par an ou
toutes les 250 heures de travail. Encas de conditions extremes
ou specitiques d'utilisation et/ou de frequences d'entretien
insuffisantes, des intervalles plus courts sont necessaires,
N'utiliser que des pieces d'origine. L'utilisation de pieces non
aqreees entraine I'invalidation des conditions de garantie et la
responsabllite du fabricant. En cas de besoin d'intervention,
prenez contact avec votre revendeur qui prendra les mesures
adaptees, Reparation et maintenance doivent etre eftectuees
par un agent agree par Iefabricant. Toute reparation incorrecte
peut devenir dangereuse pour I'utilisateur.
Garantie
Votre produit est garanti pieces et main d'ceuvre pendant une
annee
a
partir de la date de I'achat ou du contrat d'achat
a
credit, centre les detauts de rnateriaux ou de fabrication
pendant la production. Pendant la periods de garantie, nous
prendrons en charge gratuitement,
a
notre discretion, la
reparation ou Ie remplacement de toute piece detectueuse
sous reserve des conditions suivantes.
CONDITIONS
1. Les reclamations presentees dans Ie cadre de la garantie
doivent etre accornpaqnees de la facture/ du contrat de
vente delivrete) au moment de la vente ou du nurnero de
serie de la machine.
2. Pour toute reclamation dans Ie cadre de la garantie,
contactez Ie fournisseur aupres duquel Ie produit a ete
achete car c'est lui qui prendra les mesures appropriees,
Ne pas retourner Ie produit tout de suite car il pourrait
subir des dommages lors du transport.
3. Ni Truvox ni ses distributeurs ne pourraient etre tenus pour
responsablede toute perte rnaterielleou imrnaterielle.
4. Cette garantie est regie par la legislation en vigueur en
Angleterre.
5. Cette garantie ne couvre pas:
L'entretien requlier, les reparations et Ie
remplacement de pieces d'usure.
Les dommages causes pas accident, par un mauvais
usage ou par negligence, ou encore par la fixation de
pieces autres que celles de Truvox.
Les defauts de pieces autres que celie de Truvox, ou
des reparations, des modifications ou reglages
realises par une autre personne autre que par un
inqenieur conseiller de Truvox ou un agent de service
agree.
Les coats et risques de transport en rapport direct ou
non avec lagarantie du produit.
Des produits consommables tels que les brosses,
disques d'entrainement, filtres et collerettes vides.
• Cette garantie n'affecte pas vos droits leqaux ni vos droits
centre Iefournisseur provenant des ventes ou du contrat
d'achat. La politique de developpernentde produits
reserve Ie droit de changer les specifications sans
preavls,
02·17

Accessoires
Code de Produit Denomination
1903627900013 HEPA13
05-4739-0000 Sacs poussiere (lot de 12)
1903108000002 Flexible + coude
1903408500001 Tube telescopique
HB15C Suceur sols mixte
1903304900001 Suceur plat et brosse ronde
Diagnostic de panne
~ AVERTISSEMENT : Avant de proceder
a
des operations de maintenance ou
a
des
~ reglages, pensez
a
etelndre la machine et
a
la debrancher
Les verifications suivantes sont simples et peuvent etre realisees par l'operateur,
Trouble Reason Remedy
L'aspirateur ne fonctionne •Manque de tension/courant •Verifiez Iefusible*, Iefil electrique, la
pas electrlque, fiche et la prise de courant.
Perte d'aspiration •Sac plein •Remplacer Iesac
•Flexibles ou tube bouche •Oegager les obstructions
•Le moteur ne fonctionne pas •Contacter Iefournisseur
Le moteur ne tourne pas •Commutateur casse •Contacter Iefournisseur
•Cordon d'alimentation detectueux
•Moteurs detectueux
* Si les fusibles sautent plusieurs fois, I'aspirateur doit etre veritie par un agent agree.
MERCI DE VOUS REFERER A LA FIN DE CE MANUEL D'UTILISATION POUR LES
INSTRUCTIONS EN PICTOGRAMME
702-17

8
02-17

9
•
02-17

10 02-17

11
02-17

12 02-17

13
02-17

14
02-17
Table of contents
Languages:
Other Truvox International Vacuum Cleaner manuals

Truvox International
Truvox International Valet BackPack User manual

Truvox International
Truvox International Valet 10–V10 Installation instructions

Truvox International
Truvox International Valet Commercial VCU User manual

Truvox International
Truvox International HM10 User manual

Truvox International
Truvox International BOMAC User manual

Truvox International
Truvox International VT12 User manual

Truvox International
Truvox International VA20HD User manual

Truvox International
Truvox International Valet Tub Vac Installation instructions