Tsurumi Pump LB-250 User manual

%
,1752'8&7,21
7KDQN\RXIRUVHOHFWLQJWKH7VXUXPL/%6XEPHUVLEOH*HQHUDO'HZDWHULQJ3RUWDEOH3XPS
IRU\RXUDSSOLFDWLRQ
7KLVHTXLSPHQWVKRXOGQRWEHXVHGIRUDSSOLFDWLRQVRWKHUWKDQWKRVHOLVWHGLQWKLVPDQXDO
)DLOXUHWRREVHUYHWKLVSUHFDXWLRQPD\OHDGWRDPDOIXQFWLRQRUDQDFFLGHQW,QWKHHYHQWRI
DPDOIXQFWLRQRUDQDFFLGHQWWKHPDQXIDFWXUHUZLOOQRWDVVXPHDQ\OLDELOLW\$IWHUUHDGLQJ
WKLV2SHUDWLRQ0DQXDONHHSLWLQDORFDWLRQWKDWLVHDVLO\DFFHVVLEOHVRWKDWLWFDQEHUH
IHUUHGWRZKHQHYHULQIRUPDWLRQLVQHHGHGZKLOHRSHUDWLQJWKHHTXLSPHQW
23(5$7,210$18$/
/%6XEPHUVLEOH3RUWDEOH'HZDWHULQJ3XPS
/% /%7
/%$$ /%=
/% /%7
/%$ /%=
&217(176
%(685(725($')256$)7<
3$571$0(6
35,257223(5$7,21
,167$//$7,21
(/(&75,&$/:,5,1*
23(5$7,21
0$,17(1$1&($1',163(&7,21
',6$66(0%/<$1'5($66(0%/<352&('85(
7528%/(6+227,1*
768580,0$18)$&785,1*&2/7'

%(685(725($')25<2856$)(7<
:The mark indicates an action that must be taken, or instructs how to perform a task. The symbol
inside the mark describes the precaution in more detail ("provide ground work", in the case of the
example on the left).
:The mark indicates a WARNING or CAUTION item. The symbol inside the mark describes the
precaution in more detail ("electrical shock", in the case of the example on the left).
●
: Operating the equipment improperly by failing to observe this precaution may possibly
cause injury to humans and other physical damage.
: Operating the equipment improperly by failing to observe this precaution may possibly
lead to death or injury to humans.
: Gives information that does not fall in the WARNING or CAUTION categories.
●
:The mark indicates a prohibited action. The symbol inside the mark, or a notation in the vicinity of
the mark describes the precaution in more detail ("disassembly prohibited", in the case of the
example on the left).
Be sure to thoroughly read and understand the SAFETY PRECAUTIONS given in this section before using
the equipment in order to operate the equipment correctly.
The precautionary measures described in this section are intended to prevent danger or damage to you or
to others. The contents of this manual that could possibly be performed improperly are classified into two
categories: WARNING, and CAUTION. The categories indicate the extent of possible damage
or the urgency of the precaution. Note however, that what is included under CAUTION may at times
lead to a more serious problem. In either case, the categories pertain to safety-related items, and as such,
must be observed carefully.
WARNING
CAUTION
NOTE
Explanation of Symbols:
35(&$87,216727+(352'8&763(&,),&$7,216
35(&$87,216'85,1*75$163257$1',167$//7,21
Do not operate the product under any conditions other than those for which it is speci-
fied. Failure to observe the precaution can lead to electrical leakage, electrical
shock, fire, water overflow or other problems.
CAUTION
Frequency
Voltage
WARNING
Power
Supply
Capacity
When transporting the product, pay
close attention to its center of
gravity and mass. Use an appropri-
ate lifting equipment to lift the unit.
Improper lifting may result in the fall
of the product which could cause
damage of the product or human injury.
Electrical wiring should be
performed in accordance with all
applicable regulations in your
country. Imperfect wiring or
neglecting the installation of
proper equipment will cause
electrical leakage or fire.
Use a power outlet that has a sufficient rating and has been exclusively
provided for the pump. If the power outlet is shared with other equipment,
it can lead to an abnormal heat of the outlet and can cause fire as a
result.
Install the product properly in
accordance with this instruction
manual. Improper installation
may result in electrical leakage,
electrical shock, fire, water
leakage, or injury.
Provide a secure grounding
dedicated for the product. Never
fail to provide an earth leakage
circuit breaker and a thermal
overload relay in your starter or
control panel (Both available on
the market). If an electrical
leakage occurs by due to a
product failure, it may cause
electrical shock.

CAUTION
Do not scratch, fold, twist, make
alterations, or bundle the cable, or
use it as a lifting device. The cable
may be damaged, which may
cause electrical leakage, short-
circuit, electrical shock, or fire.
Be sure to provide a ground wire
securely. Do not connect the
ground wire to a gas pipe,
water pipe, lightening rod, or
telephone ground wire. Improper
grounding could cause electri-
cal shock.
Do not use the cabtyre cable, power
plug, or power outlet if it is damaged
or it is not closely fitted. Connect
every conductor of the cabtyre cable
securely to the terminals. Failure to
observe this can lead to electrical
shock, short-circuit, or fire.
When the product will be carried by
hand, decide the number of persons
considering the mass of the product.
When lifting up the product, do
not attempt to do it by simply
bowing from the waist. Use the
knees, too, to protect your back.
This pump is neither dust-proof nor
explosion-proof. Do not use it at a
dusty place or at a place where
toxic, corrosive or explosive gas is
present. Use in such places
could cause fire or explosion.
Prevent a metallic object or dust
from sticking to the power plug.
Adhesion of foreign object to the
plug could cause electrical
shock, short-circuit, or fire.
35(&$87,216'85,1*7(6723(5$7,21$1'23(5$7,21
CAUTION
WARNING
Never try to operate the pump if
somebody is present in the pump
sump.If an electrical leakage
occurs, it can cause electrical
shock.
When changing power connection is
needed to correct the direction of
rotation, be sure to turn off the
power supply (earth leakage circuit
breaker, etc.), and perform the work
after making sure that the impeller
has stopped completely. Failure to
do so may lead to electrical
shock, short-circuit, or injury.
Never start the pump while it is
suspended, as the unit may jerk
and could lead to injury.
When inspecting the pump, be sure
to turn off the power supply (earth
leakage circuit breaker, etc.) so that
the pump may not start acciden-
tally. Failure to do so may lead to
a serious accident.
Do not operate the product under
any voltage other than described
on the nameplate with the voltage
variation limit within ±10%. If it is
operated with a generator, it is
strongly suggested not to operate
other equipment with the same
generator. Failure to observe
this caution may cause
malfunction and breakdown of
the product, which may lead to
electrical leakage or electrical
shock.
Do not touch the product with bare
hands during or immediate after
the operation, as the product may
become very hot during operation.
Failure to observe this caution
may lead to be burned.
Do not use the product in a liquid
other than water. Use in oil, salt
water or organic solvents will
damage it, which may lead to
electrical leakage or electrical
shock.
Do not run the product dry or
operate it with its gate valve
closed, as doing so will damage
the product, which may lead to
electrical leakage or electrical
shock.
For water
only
Rated
Voltage
OFF
OFF
STOP

CAUTION
!
!
Failure to observe
this caution could cause it to
malfunction or to operate abnor-
mally, which may lead to electri-
cal leakage or electrical shock.
! doing so
will damage the product, which
may lead to electrical leakage or
electrical shock.
!
"
!#
Deterioration of the insulation
may lead to electrical leakage,
electrical shock, or fire.
%$$
35(&$87,216'85,1*0$,17(1$1&($1',163(&7,21
CAUTION
WARNING
Absolutely turn off the power
supply or disconnect the plug
before starting maintenance or
inspection. Do not work with wet
hands. Failure to observe these
cautions may lead to electrical
shock or injury.
After reassembly, always perform a test operation before resuming use of the
product. Improper assembly can result in electrical leakage, electrical
shock, fire, or water leakage.
In case any abnormality (excessive
vibration, unusual noise or odor) is
found in the operation, turn the
power off immediately and consult
with the dealer where it was
purchased or Ts urumi representa-
tive. Continuing to operate the
product under abnormal condi-
tions may result in electrical
shock, fire, or water leakage.
Do not disassemble or repair any
parts other than those designated
in the operation manual. If repairs
are necessary in any other than
the designated parts, consult with
the dealer where it was
purchased or Ts urumi representa-
tive. Improper repairs can
result in electrical leakage,
electrical shock, fire, or water
leakage.
Test
operation
STOP
OFF
OFF
35(&$87,217232:(5287$*(
27+(535(&$87,21
In case of power outage, turn off the power supply. The product will resume
operation when the power is restored, which presents serious danger to
people in the vicinity.
WARNING
power
outage
OFF
CAUTION
Never use the product for potable water. It may present a danger to human
health.
Potable
Water

$IWHUXQSDFNLQJYHULI\WKHFRQWHQWV
3URGXFW,QVSHFWLRQ
,QVSHFWWKHSURGXFWIRUGDPDJHGXULQJVKLSPHQWDQGPDNHVXUHDOOEROWVDQGQXWVDUHWLJKWHQHGSURSHUO\
6SHFLÀFDWLRQ&KHFN
&KHFNWKHQDPHSODWHRIWKHXQLWWRYHULI\WKDWLWLVWKHSURGXFWWKDW\RXKDYHRUGHUHG3D\SDUWLFXODUDWWHQWLRQ
WRLWVYROWDJHDQGIUHTXHQF\VSHFLÀFDWLRQV
,I\RXGLVFRYHUDQ\GDPDJHRUGLVFUHSDQF\LQWKHSURGXFWSOHDVHFRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQW
ZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXUDUHD
Note:
([DPSOH
3$571$0(6
Handle
Hose Coupling
Oil Plug
Oil Lifter
Suction Cover
Strainer Stand
Cabtyre Cable
Mechanical Seal
Lubricant
Shaft Sleeve
V-Ring
Oil Casing
Rear Liner
Impeller
35,257223(5$7,21
$FFHVVRU\&KHFN
9HULI\WKDWDOODFFHVVRU\LWHPVDUHLQFOXGHGLQWKHSDFNDJH
+RVH%DQG SF
2SHUDWLRQ0DQXDO
,I\RXGLVFRYHUDQ\GDPDJHRUGLVFUHSDQF\LQWKHSURGXFWSOHDVHFRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQW
ZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXUDUHD
Note:

7KHVXSSO\YROWDJHVKRXOGEHZLWKLQRIWKHUDWHGYROWDJH
7KHZDWHUWHPSHUDWXUHIRURSHUDWLQJWKHSXPSVKRXOGEHEHWZHHQaʝ
)DLOXUHWRREVHUYHWKHSUHFDXWLRQVJLYHQDERYHFRXOGFDXVHWKHSXPSWR
PDOIXQFWLRQZKLFKPD\OHDGWRFXUUHQWOHDNDJHRUHOHFWULFDOVKRFN
CAUTION
&ULWLFDO8VH3UHVVXUH
'RQRWRSHUDWHWKHSXPSLQDQDUHDWKDWLVH[SRVHGWRDZDWHUSUHVVXUHWKDW
H[FHHGVWKHYDOXHVJLYHQEHORZ
CAUTION
7RXVHWKHSXPSIRUDVSHFLDOVROXWLRQFRQWDFWWKHGHDOHUZKHUHLWZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI
¿FHLQ\RXUDUHD
Note:
7KHZHLJKWPDVVJLYHQDERYHLVWKHRSHUDWLQJZHLJKWRIWKHSXPSLWVHOIQRWLQFOXGLQJWKHFDEW\UHFDEOH
Note:
6WDQGDUGVSHFLÀFDWLRQV+]
'RQRWRSHUDWHWKLVSURGXFWXQGHUDQ\FRQGLWLRQVRWKHUWKDQWKRVHWKDWKDYH
EHHQVSHFLÀHG
CAUTION
0DMRU6WDQGDUG6SHFLÀFDWLRQV
3URGXFW6SHFLÀFDWLRQV
..*)#!"*%)/3)$1 -,1)12%,#6!,$
%+.%0!230%
!2%0!),!2%0-,2!2%0!,$#!00),'!2%0
0-3,$!2%078
3+.
+.%**%0 %+)-02%56.%
(!&2%!* -3"*%%#(!,)#!*%!*
%!0),' ()%*$%$!**%!0),'
.%#)&)#!2)-,1 063"+%01)"*%,$3#2)-,-2-0-*%
,13*!2)-, *!11
0-2%#2)-,612%+
"3)*2),
),)!230%.0-2%#2-0
)0#*%2(%0+!*.0-2%#2-0-2(%0+-$%*1
30"),%-)*,-,!$$)2)4%3"0)#!,2
-,,%#2)-, -1%-3.*),'
-2-0
Bore
mm
Model Output
kW
Phase
Max.capacity
m3/min
GPM
Starting
Method
WHT
kg
40LB-250 0.251 Capacitor-Run 10.4
40LBT-250 0.253 Direct-on-line 10.0
50LB-480 0.481 Capacitor-Run
Capacitor-Run
Capacitor-Run
10.4
50LBT-480 0.483 Direct-on-line 10.0
40LB-250A 0.251 11.0
50LB-480A 0.481 11.0
50LB-800 0.751 Capacitor-Run 13.2
50LB-800A 0.751
Max.Head
m
ft.
8.8/8.6
28.9/28.2
8.8/8.6
28.9/28.2
11.0/12.0
36.1/39.5
11.0/12.0
36.1/39.5
8.8/8.6
28.9/28.2
11.0/12.0
36.1/39.5
15.0/18.0
49.0/59.0
15.0/18.0
49.0/59.0
0.190
50.2
0.190
50.2
0.220/0.240
58.1/63.4
0.220/0.240
58.1/63.4
0.190
50.2
0.220/0.240
58.1/63.4
Capacitor-Run50LBZ-480 0.481 10.4
11.0/12.0
36.1/39.5
0.220/0.240
58.1/63.4
0.31
82.0
50LBT-800 0.753 Direct-on-line 12.8
15.0/18.0
49.0/59.0
0.31
82.0
0.31
82.0
Capacitor-Run 13.8
50LBZ-800 0.751
15.0/18.0
49.0/59.0
0.31
82.0
Capacitor-Run 13.2
,167$//$7,21
&ULWLFDO8VH3UHVVXUH 03DNJIFPïGLVFKDUJHSUHVVXUHGXULQJXVH

:KHQDKRVHLVXVHGDWWDFKWKHKRVHWRWKHKRVHFRXSOLQJDV
IDUDVLWZLOOJRWKHQIDVWHQLWVHFXUHO\ZLWKDKRVHEDQG
3UHFDXWLRQV'XULQJ,QVWDOODWLRQ
:KHQLQVWDOOLQJWKHSXPSEHPLQGIXORIWKHSXPSVFHQWHURIJUDYLW\DQG
ZHLJKW,IWKHSXPSLVQRWVXVSHQGHGSURSHUO\WKHSXPSPD\IDOODQGEUHDN
ZKLFKPD\OHDGWRLQMXU\
:KHQLQVWDOOLQJRUPRYLQJWKHSXPSQHYHUVXVSHQGWKHSXPSE\WKHFDEW\UH
FDEOH'RLQJVRZLOOGDPDJHWKHFDEOHZKLFKPD\FDXVHDFXUUHQWOHDNDJH
HOHFWULFDOVKRFNRUÀUH
WARNING
CAUTION
+RZWRXVHOHYHOUHOD\XQLW/%$$$/%=
'RQRWPHDVXUHWKHLQVXODWLRQUHVLVWDQFHZLWKLQVXODWLRQ
UHVLVWDQFHWHVWHUIRUIROORZLQJSDUWV,WFDXVHVDWURXEOH
'RQRWOLIWRUKDQJWKHOHYHOUHOD\XQLW,WZLOOGDPDJHDQG
FDXVHDOHDNDJHDQHOHFWULFVKRFNDQGDÀUH
,QWKHFDVHRIWKHÁRDWW\SHGRQRWOLIWLWE\WKHÁRDWFDEOH
DVLWZLOOGDPDJHWKHFDEOHDQGOHDGWRDOHDNDJHHOHFWULFDO
VKRFNDQGÀUH
CAUTION
EHWZHHQWKHSOXJ EHWZHHQWKHHOHFWURGHRID
OHYHOUHOD\XQLW
EHWZHHQWKHHOHFWURGHRIDOHYHO
UHOD\XQLWDQGDSOXJ
'RQRWPDNH³RQ´SHULRGEHWZHHQWKHRWKHUOHYHOUHOD\XQLW
3UHSDUDWLRQIRU,QVWDOODWLRQ
6LQJOHSKDVHSRZHUVXSSO\
8VHDPHJJHUWRPHDVXUHWKHUHVLVWDQFHEHWZHHQWKHWLSRIWKH
FDEW\UHFDEOHSOXJDQGWKHJURXQGWHUPLQDOWRYHULI\WKHLQVXODWLRQ
UHVLVWDQFHRIWKHPRWRU
0HDVXUHWZLFHWKHUHVLVWDQFHEHWZHHQHDFKRIWKHWZRWLSVRIWKH
SOXJDQGJURXQG
7KLVGLDJUDPVKRZVDSLQSOXJW\SH
7KHLQVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXHRI0ȍPLQLPXPLVEDVHGRQDQHZRUUHSDLUHGSXPS)RUUHIHU
HQFHYDOXHVRIDSXPSWKDWKDVDOUHDG\EHHQSXWLQWRRSHUDWLRQUHIHUWR0DLQWHQDQFHDQG,QVSHFWLRQRI
WKLVPDQXDO
Note:
7KUHHSKDVHSRZHUVXSSO\
8VHDPHJJHUWRPHDVXUHWKHUHVLVWDQFHEHWZHHQHDFK
FRUHRIWKHFDEW\UHFDEOHDQGWKHJUHHQJURXQGZLUHWR
YHULI\WKHLQVXODWLRQUHVLVWDQFHRIWKHPRWRU
%HZDUHWKDWWKHSRZHUSOXJYDULHVE\FRXQWU\RUUHJLRQ
CAUTION
,QVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXH 0ȍPLQLPXP
Hose Band
Hose
Discharge Connection
Hose Coupling

,QVWDOOLQJWKH)ORDW
6HWWKHOHQJWKRIWKHÀRDWOHDGZLUHWRWKHGLPHQVLRQLQGLFDWHGEHORZ
)DLOXUHWRREVHUYHWKLVZLOOOHDGWRDQLPSURSHURSHUDWLRQ
,IWKHSXPSGUDZVLQDODUJHDPRXQWRIPXGLWFRXOGFDXVHWKHSXPSWRZHDU
SUHPDWXUHO\DQGOHDGWRDPDOIXQFWLRQFXUUHQWOHDNDJHDQGHOHFWULFDOVKRFN
CAUTION
2SHUDWHWKHSXPSXSULJKW,IWKHUHLVWKHOLNHOLKRRGRIWKHSXPSGUDZLQJLQH[FHVVPXGSODFHDFRQFUHWH
EORFNXQGHUWKHSXPS
5RXWHWKHKRVHDVVWUDLJKWDVSRVVLEOH([FHVVLYHEHQGLQJRIWKH
KRVHFRXOGREVWUXFWWKHÀRZRIZDWHUUHGXFHWKHSXPSLQJYROXPH
RUFORJWKHSXPSZLWKPXGWKXVGLVDEOLQJWKHSXPSLQJIXQFWLRQ
,IWKHKRVHLVNLQNHGDWLWVEDVHLWZLOOFUHDWHDLUSRFNHWVLQWKH
SXPSFDXVLQJWKHSXPSWRRSHUDWHGU\7RSUHYHQWWKLVIURP
RFFXUULQJVWUDLJKWHQWKHEHQGZKLOHRSHUDWLQJWKHSXPS
,IWKHKRVHEHFRPHVNLQNHGDVVKRZQLQ$UHSRVLWLRQWKHKRVH
FRXSOLQJVRWKDWLWIDFHVDVVKRZQLQ%/RRVHQWKHFDSQXWRQ
WKHKRVHFRXSOLQJWRFKDQJHLWVGLUHFWLRQ
2SHUDWHWKHSXPSLQDORFDWLRQWKDWKDVDVXI¿FLHQWZDWHUOHYHODQGFROOHFWVZDWHUHDVLO\
)RUWKHZDWHUOHYHOUHTXLUHGIRURSHUDWLQJWKHSXPSUHIHUWRWKH
H[WHUQDOGLPHQVLRQGUDZLQJZKLFKLVSURYLGHGVHSDUDWHO\
([WHQGWKHHQGRIWKHKRVHGLVFKDUJHVLGHDERYHWKHZDWHUVXU
IDFH,IWKHHQGRIWKHKRVHLVVXEPHUJHGLQZDWHULWPD\FDXVH
WKHZDWHUWRÀRZEDFNZKHQWKHSXPSKDVEHHQVWRSSHG&RQ
YHUVHO\LIWKHHQGRIWKHKRVHLVORFDWHGDWDOHYHOWKDWLVORZHU
WKDQWKHVRXUFHZDWHUVXUIDFHZDWHUPD\FRQWLQXHWRÀRZRXW
HYHQDIWHUWKHSXPSKDVEHHQVWRSSHG
Note:
7KHURSHIRUVXVSHQGLQJWKHSXPSGXULQJLWV
LQVWDOODWLRQPXVWEHRIDWKLFNQHVVWKDWDFFRPPRGDWHV
WKHZHLJKWRIWKHSXPS:KHQXVLQJDFKDLQPDNH
VXUHWKDWWKHFKDLQGRHVQRWEHFRPHWZLVWHG)DLOXUH
WRREVHUYHWKHVHSUHFDXWLRQVFRXOGFDXVHWKHURSHRU
FKDLQWREUHDNDQGWKHSXPSWRIDOODQGEUHDNZKLFK
FRXOGOHDGWRSHUVRQDOLQMXU\
CAUTION
+DQGOHWKHSXPSFDUHIXOO\ZLWKRXWDSSO\LQJVKRFNWRLWVXFKDVE\GURSSLQJLW7R
VXVSHQGWKHSXPSGRVRPDQXDOO\RUE\DWWDFKLQJDURSHRUFKDLQWRLWVKDQGOHV
Rope
Backflow Outflow
Pump stopped
(A)
(B) Cap Nut
Pump model L
LBZ-800
LBZ-480 150mm
200mm

(OHFWULFDO:LULQJ:RUN
$OOHOHFWULFDOZRUNPXVWEHSHUIRUPHGE\DQDXWKRUL]HGHOHFWULFLDQ
LQFRPSOLDQFHZLWKORFDOHOHFWULFDOHTXLSPHQWVWDQGDUGVDQGLQWHUQDO
ZLULQJFRGHV1HYHUDOORZDQXQDXWKRUL]HGSHUVRQWRSHUIRUPHOHFWULFDO
ZRUNEHFDXVHLWLVQRWRQO\DJDLQVWWKHODZEXWLWFDQDOVREHH[WUHPHO\
GDQJHURXV
,PSURSHUZLULQJFDQOHDGWRFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
$EXVROXWHO\SURYLGHDGHGLFDWHGHDUWKOHDNDJHFLUFXLWEUHDNHUDQGDWKHUPDO
RYHUORDGUHDO\VXLWDEOHIRUWKHSXPSDYDLODEOHRQWKHPDUNHW)DLOXUH
WRIROORZWKLVZDUQLQJFDQFDXVHHOHFWULFDOVKRFNRUH[SORVLRQZKHQWKH
SURGXFWIDLOVRUDQHOHFWULFDOOHDNDJHRFFXUV
2SHUDWHZHOOZLWKLQWKHFDSDFLW\RIWKHSRZHUVXSSO\DQGZLULQJ
WARNING
*URXQGLQJ
%HVXUHWRLQVWDOOWKHJURXQGZLUHVHFXUHO\)DLOXUHWRREVHUYHWKLVSUHFDXWLRQ
FRXOGGDPDJHWKHSXPSDQGFDXVHFXUUHQWOHDNDJHZKLFKPD\OHDGWR
HOHFWULFDOVKRFN
'RQRWFRQQHFWWKHJURXQGZLUHWRDJDVSLSHZDWHUSLSHOLJKWQLQJURGRU
WHOHSKRQHJURXQGZLUH,PSURSHUJURXQGLQJFRXOGFDXVHHOHFWULFDOVKRFN
WARNING
CAUTION
&RQQHFWLQJWKH3RZHU3OXJ
%HIRUHLQVHUWLQJWKHSRZHUSOXJRUFRQQHFWLQJWKHZLUHVWRWKHWHUPLQDO
ERDUGPDNHVXUHWKDWWKHSRZHUVXSSO\LHFLUFXLWEUHDNHULVSURSHUO\
GLVFRQQHFWHG)DLOXUHWRGRVRPD\OHDGWRHOHFWULFDOVKRFNVKRUWRULQMXU\
FDXVHGE\WKHXQLQWHQGHGVWDUWLQJRIWKHSXPS
'RQRWXVHGDPDJHGFDEW\UHFDEOHVSRZHUSOXJVRUORRVHSRZHURXWOHWV
)DLOXUHWRREVHUYHWKLVSUHFDXWLRQFRXOGOHDGWRHOHFWULFDOVKRFNVKRUWFLUFXLW
RUÀUH
)ROORZWKHGLDJUDPRQWKHULJKWWRFRQQHFWWKHSRZHU
WARNING
CAUTION
:KHQDVLQJOHSKDVHSRZHUVRXUFHLVXVHGFRQQHFWWKH
OHDGVWRWKHFRQWUROSDQHOWHUPLQDOVDVVKRZQLQWKHGLD
JUDPPDNLQJVXUHWKH\GRQRWEHFRPHWZLVWHGWRJHWKHU
:KHQXVLQJDWKUHHSURQJJURXQGHGSOXJFRQQHFWDVVKRZQLQWKHGUDZLQJ
%HVXUHWRXVHDGHGLFDWHG
SRZHUVXSSO\ZLWKDJURXQG
OHDNDJHFLUFXLWEUHDNHU
CAUTION
7KHVKDSHRIWKHSOXJPD\GLIIHUIURPWKDWVKRZQLQ
WKHLOOXVWUDWLRQ
Note:
%HZDUHWKDWWKHSRZHUSOXJ
YDULHVE\FRXQWU\RUUHJLRQ
CAUTION
7KLVGLDJUDPVKRZVDSLQSOXJW\SH
(/(&75,&$/:,5,1*
S
ingle Phase
L1-Red(Brown) G-Green
(Green/Y
ellow)
L2-White(Blue)
L1 L2 G Ground
Three Phase
U-Red(Brown) G-Green
(Green/Yellow)
W-Black(Black)
V-White
(Blue or Grey)
U V W G
Ground
:KHQDWKUHHSKDVHSRZHUVRXUFHLVXVHGFRQQHFWWKH
OHDGVWRWKHFRQWUROSDQHOWHUPLQDOVDVVKRZQLQWKHGLD
JUDPPDNLQJVXUHWKH\GRQRWEHFRPHWZLVWHGWRJHWKHU

Non-Automatic Circuit
LB-250 , LB-480
White(Blue)
Power Supply: Three-Phase
Non-Automatic Circuit
LBT-250 , LBT-480 , LBT-800
Red(Brown) Red
Black
White(Blue or Grey)
Black(Black)
White
Green(Green/Yellow)
Green
Frame
Grounding
Ground
Circle Thermal
Protector
Coil
Coil
Coil
Heater
Heater
U
V
W
Red Blue
Black
Capacitor
Aux.Coil
Main Coil
Miniature Protector
Power Supply:Single-Phase
Non-Automatic Circuit
LB-800
Power Supply:Single-Phase
Red(Brown) Red
White
Green
(Green/Yellow) Green
Frame Grounding
Ground
L1
L2
Automatic Operation Circuit ( Level Relay Uint)
LB-250A , LB-480A
Automatic Operation Circuit (for float type)
Automatic Operation Circuit (for float type)
LBZ-480
LBZ-800
Level Relay Unit
Red Red
Ground
Red(Brown)
Black Triac
Black
White(Blue)
White
White
Green
(Green/Yellow)
Green
Frame
Grounding
L1
L2
Blue
Red
Black
Blue
Capacitor
Aux.
Coil
Main
Coil
Miniature
Protector
Transformer
Electrode
Automatic Operation Circuit (for electrode type)
LB-800A
Power Supply: Single-Phase
Level Relay Unit
Red
Ground
Red(Brown)
Black Triac
White(Blue)
White
White
Green
(Green/Yellow)
Green
Frame
Grounding
L1
L2
Capacitor
Aux.
Coil
Main
Coil
Transformer
Electrode
Power Supply: Single-Phase
Power Supply:
Single-Phase
Power Supply:
Single-Phase
Miniature
Protector
Red
Ground
Red(Brown)
White(Blue) White
Green
(Green/Yellow)
Green
Frame
Grounding
Capacitor
Aux.
Coil
Main
Coil
Circle Thermal Protector
Circle Thermal Protector
Float Switch (Normally open contact)
Red
Ground
Red(Brown)
White(Blue) White Heater
Heater
Green
(Green/Yellow)
Green
Frame
Grounding
Capacitor
Aux.Coil
Main
Coil
Circle Thermal Protector
Red
Ground
Red(Brown)
White(Blue) White
Heater
Green
(Green/Yellow)
Green
Frame
Grounding
Capacitor
Aux.Coil
Main
Coil
L1
L2
L1
L2
L1
L2
Float Switch (Normally open contact)
0RWRU3URWHFWRU
7KHSXPSLVHTXLSSHGZLWKDEXLOWLQPRWRUSURWHFWRUFLUFOHWKHUPDOSURWHFWRUPLQLDWXUHSURWHFWRU
,IDFXUUHQWRYHUORDGRURYHUKHDWLQJRFFXUVXQGHUWKHV\PSWRPVJLYHQEHORZWKHSXPSZLOOVWRSDXWRPDWL
FDOO\WRSURWHFWWKHPRWRUUHJDUGOHVVRIWKHZDWHUOHYHODWWKHWLPHRIRSHUDWLRQ
([WUHPHÀXFWXDWLRQRISRZHUVXSSO\YROWDJH
3XPSRSHUDWHGXQGHURYHUORDGFRQGLWLRQ
3XPSRSHUDWHGDWRSHQSKDVHRUELQGLQJFRQGLWLRQ
$IWHUWKHPRWRUSURWHFWRUKDVWULSSHGWKHPRWRUDXWRPDWLFDOO\UHVXPHVLWVRSHUDWLRQ7KHUHIRUHPDNHVXUH
WRGLVFRQQHFWWKHFDEW\UHFDEOHIURPWKHWHUPLQDOERDUGRUWKHSRZHURXWOHWDQGHOLPLQDWHWKHFDXVHRIWKH
SUREOHP
'RQRWRSHUDWHWKHSXPSDWXQXVXDOO\ORZKHDGRUZLWKWKHLPSHOOHUFORJJHGZLWKGHEULV'RLQJVRZLOOQRW
RQO\SUHYHQWWKHSXPSIURPDWWDLQLQJLWVIXOOSRWHQWLDOEXWPD\DOVRJHQHUDWHDEQRUPDOQRLVHDQGYLEUDWLRQ
DQGGDPDJHWKHSXPS
Note:
(OHFWULFDO&LUFXLW'LDJUDPV

3ULRUWR2SHUDWLRQ
2QFHDJDLQFKHFNWKHQDPHSODWHRIWKHSXPSWRYHULI\WKDWLWVYROWDJHDQGIUHTXHQF\DUHFRUUHFW
,PSURSHUYROWDJHDQGIUHTXHQF\RIWKHSRZHUVXSSO\ZLOOSUHYHQWWKHSXPS
IURPDWWDLQLQJLWVIXOOSRWHQWLDODQGPD\DOVRGDPDJHWKHSXPS
9HULI\WKHVSHFVRQWKHSXPSVQDPHSODWH
&KHFNWKHZLULQJSRZHUVXSSO\YROWDJHWKHFDSDFLW\RIWKHJURXQGOHDNDJHFLUFXLWEUHDNHUDQGWKH
LQVXODWLRQUHVLVWDQFHRIWKHPRWRU
,QVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXH 0їPLQLPXP
7KHLQVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXHRI0ȍPLQLPXPLVEDVHGRQDQHZRUUHSDLUHGSXPS)RUUHIHU
HQFHYDOXHVRIDSXPSWKDWKDVDOUHDG\EHHQSXWLQWRRSHUDWLRQUHIHUWR0DLQWHQDQFHDQG,QVSHFWLRQ
$GMXVWWKHVHWWLQJRIWKHWKHUPDOUHOD\LH(UHOD\WRWKHSXPSVUDWHGFXUUHQW
9HULI\WKHUDWHGFXUUHQWRQWKHSXPSVQDPHSODWH
CAUTION
Note:
Note:
Note:
121$8720$7,&23(5$7,21
7ULDO2SHUDWLRQ
1HYHUVWDUWWKHSXPSZKLOHLWLVVXVSHQGHGDVWKHSXPSPD\MHUNDQGFDXVH
DVHULRXVDFFLGHQWLQYROYLQJLQMXU\
2SHUDWHWKHSXPSIRUDVKRUWWLPHWRVHFRQGVDQGYHULI\WKHGLUHFWLRQRIWKHURWDWLRQRIWKHLPSHOOHU
2EVHUYHWKHSXPSXQLWIURPDERYHDQGLILWVUHFRLOLVLQWKHFRXQWHUFORFNZLVHGLUHFWLRQWKHGLUHFWLRQRI
LWVURWDWLRQLVFRUUHFW
0DNHVXUHWRFKHFNWKHSXPSVGLUHFWLRQRIURWDWLRQZLWKWKHSXPSH[SRVHG
WRWKHDWPRVSKHUH2SHUDWLQJWKHSXPSLQUHYHUVHZKLOHLWLVVXEPHUJHGLQ
ZDWHUZLOOGDPDJHWKHSXPSZKLFKPD\OHDGWRFXUUHQWOHDNDJHDQGHOHFWULFDO
VKRFN
7RUHYHUVHWKHURWDWLRQWKHIROORZLQJFRXQWHUPHDVXUHVPXVWEHWDNHQ
WARNING
CAUTION
%HIRUHFKDQJLQJWKHFRQQHFWLRQVIRUUHYHUVH
URWDWLRQPDNHVXUHWKDWWKHSRZHUVXSSO\
LHFLUFXLWEUHDNHULVSURSHUO\GLVFRQQHFWHG
DQGWKDWWKHLPSHOOHUKDVVWRSSHG
FRPSOHWHO\)DLOXUHWRREVHUYHWKLVPD\OHDG
WRHOHFWULFDOVKRFNVKRUWRULQMXU\
COUNTERMEASURE
,QWHUFKDQJH DQ\ WZR RI WKH WKUHH ZLUHV GHVLJQDWHG 8 9 DQG :
UHVSHFWLYHO\
WARNING
:KHQXVLQJDJHQHUDWRUDVPXFKDVSRVVLEOHDYRLGRSHUDWLQJWKHSXPSLQFRQMXQFWLRQZLWKRWKHUW\SHV
RIHTXLSPHQW
DQGDUHDSSOLHGWRWKHWKUHHSKDVHSXPSV
Note:
23(5$7,21
Example:
U V W G
Interchanging
phases V and W
Ground

COUNTERMEASURE
,IWKHSRZHUVXSSO\YROWDJHGHYLDWHVIURPWKHYDULDWLRQYDOXHWKHFDXVHRIWKHGHYLDWLRQPD\EHWKHFDSDFLW\RI
WKHSRZHUVXSSO\RUWKHH[WHQVLRQFDEOHWKDWLVXVHG5HIHUWRVHFWLRQ(OHFWULFDO:LULQJWRRSHUDWHWKHSXPS
LQWKHFRUUHFWPDQQHU
COUNTERMEASURE
%HFDXVH DQ RYHUORDG FRQGLWLRQ PD\ EH SUHVHQW DW WKH SXPS PRWRU LI WKH
RSHUDWLQJFXUUHQWH[FHHGVWKHUDWHGFXUUHQWIROORZWKHLQVWUXFWLRQVLQVHFWLRQ
,QVWDOODWLRQWRRSHUDWHWKHSXPSLQWKHFRUUHFWPDQQHU
&RQQHFWWKHSXPSWRWKHSLSHDQGVXEPHUJHLWLQZDWHU
2SHUDWHWKHSXPSIRUDVKRUWWLPHWRPLQXWHVDQGSHUIRUPWKHIROORZLQJFKHFNV
8VLQJDQ$&DPPHWHUFODPSPHDVXUHWKHRSHUDWLQJFXUUHQWDWWKHSKDVHV8
9DQG:WKDWDUHFRQQHFWHGWRWKHWHUPLQDOERDUG
8VLQJDQ$&YROWPHWHUWHVWHUPHDVXUHWKHYROWDJHDWWKHWHUPLQDOERDUG
3RZHUVXSSO\YROWDJHYDULDWLRQ ZLWKLQRIWKHUDWHGYROWDJH
,QFDVHWKHSXPSH[KLELWVDQDEQRUPDOFRQGLWLRQVXFKDVDFRQVLGHUDEOH
DPRXQWRIYLEUDWLRQQRLVHRUVPHOOGLVFRQQHFWWKHSRZHUVXSSO\
LPPHGLDWHO\DQGFRQWDFWWKHGHDOHUZKHUH\RXSXUFKDVHGWKHHTXLSPHQWRU
7VXUXPLVVDOHVRIÀFHLQ\RXUDUHD,IWKHSXPSFRQWLQXHVWREHXVHGLQWKH
DEQRUPDOVWDWHLWPD\FDXVHFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
3URFHHGZLWKWKHQRUPDORSHUDWLRQLIQRDEQRUPDOFRQGLWLRQVDUHIRXQGGXULQJWKHWULDORSHUDWLRQ
CAUTION
2SHUDWLRQ
7KHSXPSXQLWPD\EHH[WUHPHO\KRWGXULQJRSHUDWLRQ7RSUHYHQWEXUQVGR
QRWWRXFKWKHSXPSXQLWZLWKEDUHKDQGVGXULQJRUDIWHUWKHRSHUDWLRQ
3D\DWWHQWLRQWRWKHZDWHUOHYHOGXULQJWKHSXPSRSHUDWLRQ7KHSXPSPD\EHFRPHGDPDJHGLILWLVDOORZHG
WRRSHUDWHGU\
'XHWRDQRYHUORDGRSHUDWLRQRUDSXPSPDOIXQFWLRQLIWKHPRWRUSURWHFWRUWULSVWRVWRSWKHSXPSPDNHVXUH
WRHOLPLQDWHWKHFDXVHRIWKHSUREOHPEHIRUHUHVWDUWLQJ
7RRSHUDWHDVXEPHUVLEOHSXPSLQFOXGLQJDXWRPDWLFRSHUDWLRQVHWWKHZDWHUOHYHOVRWKDWWKHSXPSZLOO
RSHUDWHDERXWWLPHVSHUKRXU
$ODUJHDPRXQWRIDPSHUDJHÀRZVZKHQDVXEPHUJLEOHSXPSLVVWDUWHGFDXVLQJWKHWHPSHUDWXUHRILWVZLQG
LQJVWRULVHUDSLGO\%HZDUHWKDWDIUHTXHQWVWRSDQGJRRSHUDWLRQRIWKHSXPSZLOODFFHOHUDWHWKHGHWHULRUD
WLRQRIWKHLQVXODWLRQRIWKHPRWRUZLQGLQJVDQGWKXVDIIHFWWKHXVHOLIHRIWKHPRWRU
WARNING
Note:
2SHUDWLQJ:DWHU/HYHO
'RQRWRSHUDWHWKHSXPSEHORZWKH&:/&RQWLQXRXV5XQQLQJ:DWHU/HYHO
LQGLFDWHGEHORZ)DLOXUHWRREVHUYHWKLVFRQGLWLRQPD\UHVXOWLQGDPDJHWR
WKHSXPSHOHFWULFDOOHDNDJHRUHOHFWULFDOVKRFN
CAUTION
V
U V G
W
Ground
C.W
.L.
Pump Model C.W.L.
(mm)
LB-250 50
LBT-250 50
LB-480 50
LBT-480 50
50
LBT-800
50
LB-800
UVWG
Ground

$XWRPDWLF2SHUDWLRQIRUHOHFWURGHW\SH
2SHUDWLRQ:DWHU/HYHO
6WDUWRIWKHSXPS
7KHSXPSVWDUWVZKHQWKHFXUUHQWFRQWLQXRXVO\ÁRZVEHWZHHQWKHWZRHOHFWURGHVIRUPRUHWKDQRQH
VHFRQG
7KHQHFHVVDU\ZDWHUOHYHOWRRSHUDWH
WKHSXPSLVPPRUPPIURP
WKHERWWRPRIDSXPS
,QFDVHRIVWDUWE\UDFLQJGXULQJWKH
WULDORSHUDWLRQSOHDVHVKRUWFLUFXLWIRU
PRUHWKDQRQHVHFRQGZLWKH[FLWLQJ
LWHPVVFUHZGULYHUHWFEHWZHHQWKH
HOHFWURGHVDQGVWDUWIRUFLEO\
3OHDVHNHHSDZD\IURPWKRVHWKDWPD\
FORJLQDSXPSZLUHQDLOFRUGHWF
Note:
7ULDO2SHUDWLRQ
1HYHUVWDUWWKHSXPSZKLOHLWLVVXVSHQGHGDVWKHSXPSPD\MHUNDQGFDXVH
DVHULRXVDFFLGHQWLQYROYLQJLQMXU\
2SHUDWHWKHSXPSWRPLQXWHVWRYHULI\WKHFRQGLWLRQVOLVWHGEHORZ
WARNING
,QFDVHWKHSXPSH[KLELWVDQDEQRUPDOFRQGLWLRQVXFKDVDFRQVLGHUDEOH
DPRXQWRIYLEUDWLRQQRLVHRUVPHOOGLVFRQQHFWWKHSRZHUVXSSO\
LPPHGLDWHO\DQGFRQWDFWWKHGHDOHUZKHUH\RXSXUFKDVHGWKHHTXLSPHQWRU
7VXUXPLVVDOHVRIÀFHLQ\RXUDUHD,IWKHSXPSFRQWLQXHVWREHXVHGLQWKH
DEQRUPDOVWDWHLWPD\FDXVHFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
3URFHHGZLWKWKHQRUPDORSHUDWLRQLIQRDEQRUPDOFRQGLWLRQVDUHIRXQGGXULQJWKHWULDORSHUDWLRQ
CAUTION
$XWRPDWLF2SHUDWLRQIRUÁRDWW\SH
7ULDO2SHUDWLRQ
7KHWULDORSHUDWLRQPXVWEHFRPSOHWHGZLWKLQPLQXWH
Note:
,QFDVHWKHSXPSH[KLELWVDQDEQRUPDOFRQGLWLRQVXFKDVDFRQVLGHUDEOH
DPRXQWRIYLEUDWLRQQRLVHRUVPHOOGLVFRQQHFWWKHSRZHUVXSSO\
LPPHGLDWHO\DQGFRQWDFWWKHGHDOHUZKHUH\RXSXUFKDVHGWKHHTXLSPHQWRU
7VXUXPLVVDOHVRIÀFHLQ\RXUDUHD,IWKHSXPSFRQWLQXHVWREHXVHGLQWKH
DEQRUPDOVWDWHLWPD\FDXVHFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
CAUTION
(TXLSSHGZLWKÀRDWVWRGHWHFWWKHZDWHUOHYHOWKHDXWRPDWLFW\SH/%=
SXPSFDQSHUIRUPDQDXWRPDWLFGUDLQDJHRSHUDWLRQDORQHE\PHUHO\
FRQQHFWLQJLWVFDEOHWRDSRZHUVXSSO\
&RQQHFWWKHSRZHUDQGSHUIRUPDWULDORSHUDWLRQDVIROORZV
'LUHFWDOOWKHÀRDWVGRZQZDUG
5DLVHWKH\HOORZÀRDW7KLVZLOOFDXVHWKHSXPSWRVWDUW
1H[WUHWXUQWKH\HOORZÀRDWWRWKHLURULJLQDOSRVLWLRQV7KLVZLOO
FDXVHWKHSXPSWRVWRS
3HUIRUPVWHSVDQGFRQVHFXWLYHO\WZRRUPRUHWLPHVWR
YHULI\WKHRSHUDWLRQ
Check float switch operation
Move
Float Switch
115mm (LB-250A/480A)
170mm (LB-800A)
The lowest starting level
In case o
f
f
orced starting
Level Relay Unit
Screw driver
more than one (1) second
7KHHOHFWURGHPD\QRWGHWHFWWKHZDWHU
VXUIDFHXQGHUFRQGLWLRQVVXFKDV
SXUL¿HGZDWHURUGLVWLOODWHGZDWHUZKLFK
WKHFXUUHQWGRHVQRWÀRZFDXVHRIKLJK
VSHFL¿FUHVLVWDQFH
Note:

2SHUDWLRQ)ORZ&KDUW
7RHQDEOHWKHXVHUWREULQJWKHSXPSVDELOLW\LQWRIXOOSOD\WKLVFKDUWGHVFULEHVWKHYDULRXVFRQWUROPRGHVWKDW
DUHPDGHSRVVLEOHE\WKHFRPELQDWLRQVRIWKHHOHFWURGHDQGWLPHUIXQFWLRQV
Start
Operation
(Drainage)
Level Relay Unit Pump
Water
Level Condition
Drop
[Switch on]
Operation
(Drainage)
Stop
Operation
(Drainage)
Start
Operation
(Drainage)
Drop
Drop
Rise
Drop
The draining of water by the timer lasts
approximately 1 minute.
(Detection Time : more than one (1) second)
(Electrodes open Trips the timer)
(Detection Time : more than one (1) second)
Level Relay
Unit
Level Relay Unit
Electrode
※
※
When the water level rises and the water
surface comes in contact for more than one
(1) second with the electrodes, the pump will
restart.
The pump will stop 1 minute later.
The pump will also stop after a continuous
dry run, in some cases.
If the water surface comes in contact for more than
one (1) second with the electrodes within 1 minute,
the pump will operate continuously even though the
timer has tripped.
As the water level drops and the water
surface recedes from the electrodes, the
timer trips to drain water.
The electrodes of the level relay unit are
submerged, causing the current to operate
the pump.

5HJXODUPDLQWHQDQFHDQGLQVSHFWLRQDUHLQGLVSHQVDEOHWRPDLQWDLQLQJWKHSXPSVSHUIRUPDQFH,IWKH
SXPSEHKDYHVGLIIHUHQWO\IURPLWVQRUPDORSHUDWLQJFRQGLWLRQUHIHUWRVHFWLRQ7URXEOHVKRRWLQJDQG
WDNHDSSURSULDWHPHDVXUHVDWDQHDUO\VWDJH:HDOVRUHFRPPHQGWKDW\RXKDYHDVSDUHSXPSRQKDQG
IRUDQHPHUJHQF\
3ULRUWR,QVSHFWLRQ
0DNHVXUHWKDWWKHSRZHUVXSSO\LHFLUFXLWEUHDNHULVGLVFRQQHFWHGDQG
GLVFRQQHFWWKHFDEW\UHFDEOHIURPWKHSRZHURXWOHWRUUHPRYHLWIURPWKH
WHUPLQDOERDUG)DLOXUHWRGRVRPD\FDXVHHOHFWULFDOVKRFNRUXQLQWHQGHG
VWDUWLQJRIWKHSXPSZKLFKPD\OHDGWRVHULRXVDFFLGHQWV
:DVKLQJWKH3XPS
5HPRYHDQ\GHEULVDWWDFKHGWRWKHSXPSVRXWHUVXUIDFHDQGZDVKWKHSXPSZLWKWDSZDWHU3D\
SDUWLFXODUDWWHQWLRQWRWKHLPSHOOHUDUHDDQGFRPSOHWHO\UHPRYHDQ\GHEULVIURPWKHLPSHOOHU
,QVSHFWLQJWKH3XPS([WHULRU
9HULI\WKDWWKHUHLVQRGDPDJHDQGWKDWWKHEROWVDQGQXWVKDYHQRWORRVHQHG
,IWKHSXPSPXVWEHGLVDVVHPEOHGIRUUHSDLUGXHWRGDPDJHRUORRVHEROWVRUQXWVFRQWDFWWKHGHDOHUZKHUH
LWZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXUDUHD
WARNING
Note:
'DLO\DQG3HULRGLF,QVSHFWLRQ
5HIHUWRVHFWLRQ2LO,QVSHFWLRQDQG&KDQJH3URFHGXUHVEHORZIRUIXUWKHUGHWDLO
Note:
0$,17(1$1&($1',163(&7,21
Interval
Monthly
Daily
Semi-yearly
Inspection Item
Yearly
Once every
2 to 5 years
Measuring the operating current To be within the rated current
Measuring the insulation resistance Insulation resistance reference value = 1MΩminimum
[NOTE] The motor must be inspected if the insulation resistance is considerably lower
than the last inspection.
Inspecting oil
[NOTE] The inspection and replacement of the mechanical seal requires specialized
equipment. To have this operation performed, contact the dealer where this
equipment was purchased, or the Tsurumi sales office in your area.
Overhaul The pump must be overhauled even if the pump appears normal during operation.
Especially, the pump may need to be overhauled earlier if it is used continuously.
[NOTE] To overhaul the pump, contact the dealer where it was purchased, or the
Tsurumi sales office in your area.
1,000 hours or 6 months, whichever comes first.
Changing oil
Changing the mechanical seal
2,000 hours or 12 months, whichever comes first.
Power supply voltage variation
= within ±10% of the rated voltage
Measuring the power voltage
Inspection of liffting rope Replace if damage, corrosion, or wear has occurred to the rope.
Remove if foreign object is attaching to it.

6WRUDJH
,IWKHSXPSZLOOQRWEHRSHUDWHGIRUDORQJSHULRGRIWLPHSXOOWKHSXPSXSZDVKWKHSXPSDOORZLWWRGU\
DQGVWRUHLWLQGRRUV
)RUUHLQVWDOODWLRQEHVXUHWRSHUIRUPDWULDORSHUDWLRQEHIRUHSXWWLQJWKHSXPSLQWRRSHUDWLRQ
,IWKHSXPSUHPDLQVLPPHUVHGLQZDWHURSHUDWHLWRQDUHJXODUEDVLVLHRQFHDZHHN
Note:
2LO,QVSHFWLRQDQG&KDQJLQJ3URFHGXUHV
,QVSHFWLQJ2LO
5HPRYHWKHRLOSOXJDQGWDNHRXWDVPDOODPRXQWRIRLO
7KHRLOFDQEHH[WUDFWHGHDVLO\E\WLOWLQJWKHSXPSVRWKDW
WKHRLO¿OOHUSOXJIDFHVGRZQZDUG,IWKHRLODSSHDUVPLON\
RULQWHUPL[HGZLWKZDWHUDOLNHO\FDXVHLVDGHIHFWLYHVKDIW
VHDOLQJGHYLFHLHPHFKDQLFDOVHDOZKLFKUHTXLUHVWKDW
WKHSXPSEHGLVDVVHPEOHGDQGUHSDLUHG
&KDQJLQJ2LO
5HPRYHWKHRLOSOXJDQGGUDLQWKHRLOFRPSOHWHO\3RXUD
VSHFL¿HGYROXPHRIRLOLQWRWKHRLO¿OOHULQOHW
7KHGUDLQHGRLOPXVWEHGLVSRVHGRISURSHUO\WRSUHYHQWLW
IURPEHLQJUHOHDVHGLQWRWKHVHZHURUULYHUV7KHSDFNLQJ
RUWKH2ULQJIRUWKHRLOSOXJPXVWEHUHSODFHGZLWKDQHZ
SDUWDWHDFKRLOLQVSHFWLRQDQGFKDQJH
Note:
5HSODFHPHQW3DUWV
7KHWDEOHOLVWVWKHSDUWVWKDWQHHGWREHUHSODFHGSHULRGLFDOO\5HSODFHWKHVHXVLQJWKHUHFRPPHQGHG
IUHTXHQF\DVDJXLGHOLQH
Hex Key W
rench
Oil Plug
Packing
Oil Inlet
Mechanical Seal
Lubricant ; Turbine Oil VG 32 (non-additive)
Packing, O-Ring
Part Replacement condition
V-Ring
Shaft sleeve
When oil in oil compartment becomes milky.
Every 12 mouths or after 2,000 hours of use, whichever comes first.
Each time pump is disassembled or inspected
When ring is worn, and each time pump is disassembled or inspected
When it becomes worn
LB-250, LBT-250, LB-250A
LB-480, LBT-480, LB-480A, LBZ-480
155
155
LB-800, LBT-800, LB-800A, LBZ-800
155
Pump Model Specified
Volume
Unit :
Specified Oil: Turbine Oil VG32 (non-additive)
m

'LVDVVHPEO\3URFHGXUH
3ULRUWR'LVDVVHPEO\DQG5HDVVHPEO\
7KLVVHFWLRQH[SODLQVWKHGLVDVVHPEO\DQGUHDVVHPEO\SURFHVVHVWKDWDUHLQYROYHGXSWRWKHUHSODFHPHQW
RIWKHLPSHOOHULWVHOI2SHUDWLRQVLQYROYLQJWKHGLVDVVHPEO\DQGUHDVVHPEO\RIWKHVHDOLQJSRUWLRQLH
PHFKDQLFDOVHDODQGRIWKHPRWRUUHTXLUHDVSHFLDOL]HGIDFLOLW\LQFOXGLQJYDFXXPDQGHOHFWULFDOWHVWHTXLS
PHQW)RUWKHVHRSHUDWLRQVFRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQWZDVSXUFKDVHGRUWKH7VXUXPLVDOHV
RIÀFHLQ\RXUDUHD
%HIRUHGLVDVVHPEOLQJDQGUHDVVHPEOLQJWKHSXPSEHVXUHWKDWWKHSRZHU
VXSSO\LHFLUFXLWEUHDNHULVGLVFRQQHFWHGDQGUHPRYHWKHFDEW\UHFDEOH
IURPWKHRXWOHWRUWKHWHUPLQDOERDUG'RQRWFRQQHFWRUGLVFRQQHFWWKH
SRZHUSOXJZLWKDZHWKDQGLQRUGHUWRSUHYHQWHOHFWULFDOVKRFN'RQRW
SHUIRUPDQDFWLYDWLRQWHVWWRFKHFNWKHURWDWLRQRIWKHLPSHOOHUGXULQJ
GLVDVVHPEO\DQGUHDVVHPEO\)DLOXUHWRREVHUYHWKLVSUHFDXWLRQFRXOG
OHDGWRDVHULRXVDFFLGHQWLQFOXGLQJLQMXU\
WARNING
5HPRYLQJWKHVWUDLQHUVWDQGVXFWLRQFRYHUDQGWKHSXPSFDVLQJ
5HPRYHWKHKH[EROWVIURPXQGHUWKHVWUDLQHUVWDQGWKHQUHPRYHWKHVWUDLQHUVWDQGVXFWLRQFRYHUDQG
WKHSXPSFDVLQJIURPWKHSXPSERG\
5HPRYLQJWKHLPSHOOHU
8VLQJDER[ZUHQFKUHPRYHWKHLPSHOOHUQXWVSULQJZDVKHUDQGSODLQZDVKHUWKHQUHPRYHWKH
LPSHOOHUWKHVKDIWVOHHYHDQGWKHYULQJIURPWKHVKDIW
5HPRYLQJWKHUHDUOLQHU
5HPRYHWKHUHDUOLQHUIURPWKHRLOFDVLQJ
'LVDVVHPEO\'LDJUDP
([DPSOH
',6$66(0%/<$1'5($66(0%/<352&('85(
Oil Casing
Packing
Oil Plug
V-Ring
Shaft Sleeve
Rear Liner
Impeller
Plain Washer
Spring Washer
Hex. Cap Nut
Pump Casing
Suction Cover
Strainer Stand
Hex. Bolt

5HDVVHPEO\3URFHGXUH
2EVHUYHWKHSUHFDXWLRQVJLYHQEHORZDQGUHDVVHPEOHWKHXQLWLQWKHUHYHUVHRUGHURIGLVDVVHPEO\
$IWHUFRPSOHWLQJWKHUHDVVHPEO\PDNHVXUHWR¿OOWKHSXPSZLWKWKHVSHFL¿HGDPRXQWRIRLO7KHSDFNLQJV
PXVWEHUHSODFHGZLWKDQHZSDUW,IDQ\SDUWLVZRUQRUGDPDJHGPDNHVXUHWRUHSODFHLWZLWKDQHZSDUW
$IWHUUHLQVWDOOLQJWKHLPSHOOHURUWKHVXFWLRQFRYHUFKHFNWKDWWKHLPSHOOHUURWDWHVVPRRWKO\DQGWKDWWKHUHLV
QRLQWHUIHUHQFHEHWZHHQWKHSXPSFDVLQJDQGWKHVXFWLRQFRYHU
Note:
$VVHPEOHWKHUXEEHUSDUWVUHDUIDFHOLQHULPSHOOHUDQG
SXPSFDVLQJDIWHUUHPRYLQJGHEULVIURPWKHPVXFKDV
VDQG
0RXQWWKHYULQJRQWRWKHRXWVLGHRIWKHVKDIWVOHHYHDV
VKRZQLQWKHGUDZLQJ:KHQGRLQJVRGRQRWDSSO\RLORU
RWKHUOXEULFDWLRQWRWKHVXUIDFHZKHUHWKHYULQJFRQWDFWV
WKHVKDIWVOHHYH
:KHQDWWDFKLQJWKHUHDUOLQHUPDNHVXUHWKHIURQWDQG
EDFNDUHRULHQWHGFRUUHFWO\DQGSUHVVWKHOLQHU¿UPO\
RQWRWKHVXUIDFH
$IWHUUHLQVWDOOLQJWKHLPSHOOHURUWKHVXFWLRQFRYHUFKHFN
WKDWWKHLPSHOOHUURWDWHVVPRRWKO\DQGWKDWWKHUHLVQR
LQWHUIHUHQFHEHWZHHQLWDQGWKHVXFWLRQFRYHU
5HDVVHPEOLQJPRGHOV
Do not apply
oil here
V-Ring
Shaft
Motor Side
Shaft Sleeve

7RSUHYHQWVHULRXVDFFLGHQWVGLVFRQQHFWWKHSRZHUVXSSO\EHIRUHLQVSHFWLQJ
WKHSXPS
5HDGWKLV2SHUDWLRQ0DQXDOFDUHIXOO\EHIRUHUHTXHVWLQJUHSDLU$IWHUUHLQVSHFWLQJWKHSXPSLILWGRHVQRW
RSHUDWHQRUPDOO\FRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQWZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXU
DUHD
WARNING
'LVSRVDORI3URGXFW
3URSHUO\GLVSRVHRIWKHSURGXFWE\GLVDVVHPEOLQJLWSUHVRUWLQJWKHFRQWHQWVDQGVHQGLQJWKHPWRWKHZDVWH
PDWHULDOWUHDWPHQWVLWH
7KHIROORZLQJLQIRUPDWLRQLVUHTXLUHGZKHQRUGHULQJUHSDLUVRUPDNLQJRWKHULQTXLULHV
7528%/(6+227,1*
Contact the electric power company or an electrical
repair shop.
Connect the plug.
Check whether there is an open circuit in the
cabtyre cable or wiring.
Remove obstacles and check the operation of the
float.
Use sandpaper to remove the debris.
Repair or replace the level relay unit.
No proper power is supplied
(i.e. power outage).
Plug is not inserted.
Open circuit in cabtyre cable or poor
connection.
Malfunction in float.
Electrode is insulated by debris.
Malfunction in level relay unit.
Inspect the pump and remove the debris.
Remove obstacles and check the operation of the
stop float.
Provide the rated voltage or use an extension
cable that meets the specifications.
Check the nameplate and replace the pump or the
impeller.
Remove the debris from the strainer stand.
Repair or replace.
Place a concrete block under the pump to prevent
the pump from drawing in excess mud.
Foreign matter is wedged in the impeller,
causing the motor protector to trip.
The movement of the stop float is
obstructed, causing the start float alone to
perform the start and stop operations.
The voltage is too low.
A 50Hz unit is used at 60Hz.
The pump has been operated for a long
time with its strainer stand clogged.
Malfunction of motor (seizure or water
leakage).
The pump is drawing in too much mud.
Replace the bearings.Motor bearings are damaged.
Remove the blockage. Or, replace the part.
Set the water level of the (stop) float higher than the
pump's minimum possible operating water level.
Repair or replace the level relay unit.
Use sandpaper to remove the debris.
Check whether there are any wires that are tangled
around the electrode. Check whether there are any
electrical devices that could generate
electro-magnetic interference, and relocate the unit
as necessary.
The movement of the floats is obstructed.
The switch in a float is faulty.
The water level of the (stop) float is set
lower than the pump's minimum possible
operating water level.
Malfunction in level relay unit
Electrode is shorted by debris.
Influence by electrical device in the vicinity
of the pump.
Replace the impeller.
Minimize the bends of the hose, and if the pump is
used in a dusty area, place it inside a mesh basket
during operation.
Remove the debris from the strainer stand.Place a
concrete block under the pump to prevent the
pump from drawing in excess mud.
Change the power connection.
Check the nameplate and replace the pump or the
impeller.
The impeller is worn.
The hose is clogged or kinked at its
midspan.
The strainer stand is clogged or is buried.
The motor rotates in reverse.
A 60Hz pump is used at 50Hz.
Pump fails to start; or, starts
but stops immediately.
Pump generates vibration or noise.
The pump does not stop
automatically.
Problem Possible cause Countermeasure
Pump starts but stops
immediately, causing the
motor protector to trip.
The pumping volume is low.
Remarks
Purchase date
Manufacturing number
Product model
Other manuals for LB-250
2
This manual suits for next models
12
Popular Swimming Pool Pump manuals by other brands

Polygroup
Polygroup SUMMER WAVES RP400 owner's manual

Bestway
Bestway 58230 owner's manual

Theralux
Theralux Theraflo S-Series Installation and operating instruction manual

Enerpac
Enerpac MP Series instruction sheet

Intex
Intex 128376NP manual

HERBORNER pumpentechnik
HERBORNER pumpentechnik herborner.X Series operating manual

Pahlen
Pahlen Jet Swim 2000 user manual

Pentair Pool Products
Pentair Pool Products Pinnacle Operation & service manual

Pentair
Pentair WHISPERFLO VS 1500 owner's manual

Hayward
Hayward EcoStar Quick reference guide

PEDROLLO
PEDROLLO MAGNIFICA Original instructions for use

K2 Pumps
K2 Pumps PPV10001SPK owner's manual