manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tundra
  6. •
  7. Inverter
  8. •
  9. Tundra M600 User manual

Tundra M600 User manual

This manual suits for next models

1

Other Tundra Inverter manuals

Tundra M150 User manual

Tundra

Tundra M150 User manual

Tundra M1500 User manual

Tundra

Tundra M1500 User manual

Tundra IBC45 User manual

Tundra

Tundra IBC45 User manual

Tundra E-1000 User manual

Tundra

Tundra E-1000 User manual

Tundra M1500 Operation instructions

Tundra

Tundra M1500 Operation instructions

Tundra E-1000 User manual

Tundra

Tundra E-1000 User manual

Tundra CM Series User manual

Tundra

Tundra CM Series User manual

Popular Inverter manuals by other brands

Omnik New Energy Omniksol-1.5k-TL user manual

Omnik New Energy

Omnik New Energy Omniksol-1.5k-TL user manual

Agilent Technologies 33250A user guide

Agilent Technologies

Agilent Technologies 33250A user guide

4-noks ZR-SWITCH-RC instruction manual

4-noks

4-noks ZR-SWITCH-RC instruction manual

V&T V5 Series user manual

V&T

V&T V5 Series user manual

Hon Turing HT-T-S1000-12 introduction

Hon Turing

Hon Turing HT-T-S1000-12 introduction

Metabo E 140 SP Plus Original operating instructions

Metabo

Metabo E 140 SP Plus Original operating instructions

BARRON EXITRONIX Tucson Micro Series installation instructions

BARRON

BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

Baumer

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

electroil

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar TPS555-1230 instruction manual

Silicon Solar

Silicon Solar TPS555-1230 instruction manual

Mission Critical Xantrex Freedom SW-RVC owner's guide

Mission Critical

Mission Critical Xantrex Freedom SW-RVC owner's guide

HP 3312A Operating and service manual

HP

HP 3312A Operating and service manual

Hoymiles HM-500T user manual

Hoymiles

Hoymiles HM-500T user manual

Nitecore SPM10 user manual

Nitecore

Nitecore SPM10 user manual

AEG Protect PV installation manual

AEG

AEG Protect PV installation manual

On Board TruePower Plus 1200MS owner's manual

On Board

On Board TruePower Plus 1200MS owner's manual

Plugreen PGM-200P-230 Installation and operation manual

Plugreen

Plugreen PGM-200P-230 Installation and operation manual

Fourgroup Easy use and Programming Handbook

Fourgroup

Fourgroup Easy use and Programming Handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Owner Manual
M600 –MODIFIED SINE WAVE
M600-GD-0615-EN
2041-A, Leonard-de Vinci, Sainte-Julie (Quebec) Canada J3E 1Z2 9
Tel : 450.649.2470 / 1.877.964.2582 Fax : 1.888.855.9834
Congratulations! You have purchased one of the most sophisticated and reliable power inverters of the industry.
Incorporating the latest technologies, it will deliver years of trouble free operation for your truck, boat, RV or other “OFF Grid”
system.
In order to get the most out of your inverter, it must be installed and used properly. Please thoroughly read this
manual before installing and using your new inverter.
1. INSTALLATION & FUNCTIONNING
The M600 has been designed for special applications that are pre-wired. An electrical circuit capable of supporting 60A @
12 V is mandatory. You must make sure the circuit is properly fused.
This inverter must be permanently installed on a flat and even surface using its mounting flanges. *The hardware should be
strong enough to support the weight of the inverter. The inverter may be mounted on a vertical surface as long as the
cooling fan is pointing left, right or up (it must never point down). The M600 is equipped with 1 meter cables with terminal
lugs at each end. Make sure to respect the polarity of each cable.
To operate the inverter, use the ON/OFF switch located on the front panel. A green light will light up to indicate that the
inverter is now ready to deliver 120 volts power. If you intend to operate several loads from the inverter, we recommend to
switch them ON one by one up to the maximum capacity of the inverter. This will prevent the inverter from being overloaded
by the current inrush required to start all the devices simultaneously.
CAUTIONS!
1. The installation of this product requires skills and carefulness. For your safety, we recommend to have this product
installed by a certified installer.
2. Do not insert any object in the inverter; it may cause fire, electric shock or short circuit.
3. To avoid fire hazards and/or overheating; do not install the inverter in a zero clearance compartment and do not cover
or obstruct any ventilation openings.
4. This equipment contains components that may produce arcs or sparks. To reduce the risk of fire or explosion, do not
install in a compartment containing batteries or flammable materials, or in a location that requires ignition protected
equipment.
5. Reversing the polarities when connecting the DC cables will permanently damage your inverter.
This is not covered by the warranty.
2. MAINTENANCE
A power inverter only requires minimal maintenance to work properly:
1. In order to prevent dust accumulation inside its circuitry, clean the outside of your inverter and its environment
periodically using a dry cloth.
2. Your inverter must never be exposed to any liquids. If this occurs, have it inspected by a qualified technician before
use.
3. DC connections must be verified periodically and tightened if necessary.
CAUTION! Never use water of any type of liquid to clean this product. The electricity produced by this inverter can
create an electric arc in presence of humidity and cause serious injuries or even death.
Owner Manual
M600 –MODIFIED SINE WAVE
M600-GD-0615-EN
2041-A, Leonard-de Vinci, Sainte-Julie (Quebec) Canada J3E 1Z2 9
Tel : 450.649.2470 / 1.877.964.2582 Fax : 1.888.855.9834
3. SPECIFICATIONS
4. RECOMMENDATIONS
1. The M600 only works with a 12 volt DC source.
2. The inverter should always be OFF when starting the vehicle.
3. If your consumption exceeds the inverter capacity, an overload protection will automatically turn it OFF. To restart the
inverter, reduce your consumption. If the inverter doesn’t resume automatically, shut it and restart it manually using the
ON/OFF switch located on the front panel.
4. Stop using the inverter if the 12 volt power cord has been damaged. Have it repaired before using it again.
5. This inverter could get very hot. Make sure there is no flammable materials near or around it.
6. Keep the inverter away from liquids, snow or any other source of humidity. The electricity produced by the inverter can
create an electric arc in presence of humidity and cause serious injuries or even death.
7. If the inverter has been exposed to rain, moisture, or strong impact, have it inspected by a qualified technician before
using it again.
8. We strongly recommend using a «pure sine wave» inverter for sophisticated electronic devices.
9. Do not attempt any repair or modification on this product. If your inverter requires attention, contact your retailer.
Model
M600
Type
Power Inverter
Grade
Professional
Part number
TUN112003
Electrical specifications
Continuous output power
600W
Peak output power
1200W
Input voltage (nominal)
12 VDC
Operating input voltage
10-15 VDC
Output voltage
120 VAC +/- 3%
Output frequency
60 Hz
Output wave form
Modified sine wave
DC efficiency (Peak)
90%
AC efficiency (Peak)
90%
General Specifications
AC outputs
2 x NEMA 5-15R
Operating temperatures
-30° to 131°F
Cooling fan(s)
Thermostatic
Construction
Aluminium
DC inputs
1 meter cables w. lugs
Unit dimensions (W x L x H) - English (in.)
9,3 x 5,0 x 3,3
Unit dimensions (W x L x H) - Metric (cm.)
23,6 x 12,7 x 8,4
Unit weight (Lbs / kg)
4,0 / 1,8
Warranty
1 Year