turbionaire TS5GE06T User manual

AIR CURTAINS
INSTALLATION MANUAL
TS5GE06T (RM-1206S-3D/Y5G)/TS5GE06M (RM-1206S-D/Y5G)
TS5GE09T (RM-1209S-3D/Y5G)/TS5GE09M(RM-1209S-D/Y5G)
TS5GE10T (RM-1210S-3D/Y5G)/TS5GE10M (RM-1210S-D/Y5G)
TS5GE12T (RM-1212S-3D/Y5G)/TS5GE12M (RM-1212S-D/Y5G)
TS5GE15T (RM-1215S-3D/Y5G)/ TS5GE15M (RM-1215S-D/Y5G)
TS5GE18T (RM-1218S-3D/Y5G)/ TS5GE18M (RM-1218S-D/Y5G)
TS5GE20T(RM-1220S-3D/Y5G)/ TS5GE20M(RM-1220S-D/Y5G)
Thanks for purchasing this Air Curtain,
Please read these instructions carefully before use.

1、PRODUCT INTRODUCTION
As one of the new top-class products for modern decoration, air curtain is also matched
with the air-conditioner.And it is installed at the entrances of supermarket,theater,meeting
room,hotel,office room,working shop and storeroom to prevent the dust,mosquito and nocuous
air,and so on.
2、IDENTIFICATION & INSTALLATION DIMENSIONS
E
D
F
` MODEL A B C D E F
RM-1206S-3D/Y5G 600 240
90 190 105 260
RM-1209S-3D/Y5G 900
440
RM-1210S-3D/Y5G 1000
RM-1212S-3D/Y5G 1200
RM-1215S-3D/Y5G 1500
840
RM-1218S-3D/Y5G 1800
RM-1220S-3D/Y5G 2000
RM-1206S-D/Y5G 600 240
RM-1209S-D/Y5G 900
440
RM-1210S-D/Y5G 1000
RM-1212S-D/Y5G 1200
RM-1215S-D/Y5G 1500
840
RM-1218S-D/Y5G 1800
RM-1220S-D/Y5G 2000
3、INSTALLATION CAUTION
Must follow the following asking when installing air curtain:
3.1Please install the unit in a sturdy place to avoid
the shaking and ensure its security (because it
maybe causes the wall becoming flexible or shaking
and noise.
3.2 Please install the unit inside the room.

3.3 Don’t install the unit too low, no less than 2.3
meter from the ground. When the entrance is wider
than the unit, it is recommended to install two or
more units in parallel. In this case, provide
20-40mm gaps between the units.
3.4 Don’t install the unit in a place where it is
splashed by water, exposed to excessive
steam, explosive gas or corrosive gas.
4、INSTALLATION
A、Installing on the concrete wall:
4.1.1 Removed the mounting plate
Remove the plastic parts, unclamping
the fixed
screws on the back of main body to remove the
mounting plate.
PLASTIC PARTS
12
MOUNTING PLATE
21
4.1.2 Fix the bolts in the proper position
(Decide the position with the mounting plate
and pour cement into the bolt holes.)
CONC RE TE
13 -15 m m
70mm
φ40- 50mm
4.1.3 When the cement has freeze, fit the mounting
plate (use the washer and nut according to the
following)
4.1.4 Install the main body
Set the main body onto the upper end of
the mounting plate and clamp it as shown.
2
1

B、Installing on the wooden wall
C、Hanging from the ceiling
4.3.1 Remove the mounting plate from main body
(Same as step 5.1.1)
MOUNTING PIATE
FIXING SCREW
4.3.2 Fixing ceiling brackets as Fig.
CDC
NU T
S PR IN G WA S HE R
WA SHE R
4.3.3 Set the mounting plate on the ceiling
brackets and ensure safe & fixing (use the bolts
attached to the ceiling brackets as Fig. Using the
ceiling brackets to hang from the ceiling, the
position of mounting plate can be adjusted in the
limit of 100mm.
4.3.4 Do the same as step A to install the
main body.
2
1
4.2.1 Fix the mounting plate in the proper
positions with tapping screw.
MOODEN SCREW
M OUN TI N G PI ATE
4.2.2 Same as the step 4 of A
2
1

D、For above ceiling
4.4.1Fix the air curtain as in the procedure for
installing on the concrete wall.
4.4.2 Then pipe as right Fig. Instructs.
5、HEATED MODEL TECHNICAL PARAMETER
MODEL
Diam
Of
Wheel
(mm)
Volt.
/Freq.
(V~
/Hz)
Motor
power
(W)
Heater
power
(KW)
Temp.
(K)
Max.air
speed(m/s)Air volume
(m3/h) Noise(db) Net
weight
(Kg)
Ⅰ
Ⅱ
Ⅲ
H L H L H L
RM-1206S-3D/Y5G
115
380/50
140 1 2 3
35-45 9.5 8.5
840 680 56 54 11
RM-1209S-3D/Y5G 160 2 4 6 1200 1000 57 55 13.5
RM-1210S-3D/Y5G 180 2 4 6 1330 1110 57 56 14.5
RM-1212S-3D/Y5G 200 2.7 5.3 8 1700 1500 58 56 16
RM-1215S-3D/Y5G 230 3.3 6.7 10 2200 1900 59 57 18.5
RM-1218S-3D/Y5G 300 4 8 12 2700 2400 60 58 24
RM-1220S-3D/Y5G 350 4.6 9.4 14 3100 2800 61 59 26.5
RM-1206S-D/Y5G
220/50
140 1.5 3 —— 840 680 56 54 11
RM-1209S-D/Y5G 160 3 6 —— 1200 1000 57 55 13.5
RM-1210S-D/Y5G 180 1.75 3.5 —— 1330 1110 57 56 14.5
RM-1212S-D/Y5G 200 4 8 —— 1700 1500 58 56 16
RM-1215S-D/Y5G 230 5 10 —— 2200 1900 59 57 18.5
RM-1218S-D/Y5G 300 6 12 —— 2700 2400 60 58 24
RM-1220S-D/Y5G 350 7 14 —— 3100 2800 61 59 26.5
LINE SIZE
POWER
ITEM
SINGLE PHASE
(220V~,MAIN LINE:L、N)
THREE PHASES
(380V~ MAIN LINE:A、B、C、N)
HEATER POWER(kW)3 4 5 6 8 10 12 14 3 4 5 6 8 10 12 14
MAIN LINE(mm2)2.5 4.0 6.0 10 1.5 2.5 4.0 6.0
EARTH LINE(mm2)1.5 2.5 4.0 6.0 0.75 1.5 2.5 4.0
NOTE: forbid overload to operation for a long time!

WHITE
BLUE(BROWN/RED)
YELLOW
c
MOTOR
ORANGE
(YELLOW)
BLACK
YELLOW-GREEN
RECEIVER
IC
HEATER
HEATER
B C
N A PN
THERMAL CUT-OUT
THERMAL CUT-OUT
THERMAL CUT-OUT
on
com 1
2
com on
on
com 3
I/O
RECEIVER
BROWN
BLUE WHITE
GREY
YELLOW-GREEN
WHITE
BLUE(BROWN/RED)
YELLOW
c
MOTOR
ORANGE
(YELLOW)
BLACK
YELLOW-GREEN
RECEIVER
IC
HEATER
HEATER
L
NPN
THERMAL CUT-OUT
THERMAL CUT-OUT
THERMAL CUT-OUT
on
com 1
2
com on
on
com 3
I/O
RECEIVER
BROWN
BLUE WHITE
GREY
YELLOW-GREEN
6、OPERATION
6.1. Controlled by remote controller
a. Press “ON/OFF” button to turn ON the unit. Main receiver receives the signal with the sound of “beep” to start
working with the green light in cool mode at high speed “H”. Press “ON/OFF” button again to turn OFF.
b. When the unit is working at the above a. situation, press “COOL” button in the Remote controller, receiver
receives the signal with the sound of “beep” and switch high speed to low speed “L”. Meanwhile there is a
green light display in the receiver. Press “COOL” button again, the unit will switch low speed to high speed.
So when the unit is working at cool mode, press “COOL” button can switch air curtain working under the
cycle of Low or High speed.
c. FOR SINGLE PHASE UNIT: When the unit is working at the above b. situation, press “HEAT” in the remote
controller, receiver receives the signal with the sound of “beep” and switch cool mode to heating mode at low
power. Meanwhile there is a Red light display in the receiver. Press “HEAT” button again, the unit will switch
low power to high power. Meanwhile there is TWO Red lights display in the receiver. Press “HEAT” button
again, the unit will switch heating mode to cool mode and the red lights display change to green light in the
receiver. So when the unit is working at cool mode, press “HEAT” button can switch air curtain working under
the cycle of heating low power, heating high power or cool mode.
FOR THREE PHASES UNIT: When the unit is working at the above b. situation, press “HEAT” in the remote
controller, receiver receives the signal with the sound of “beep” and switch cool mode to heating mode at low
power. Meanwhile there is a Red light display in the receiver. Press “HEAT” button again, the unit will switch
low power to middle power. Meanwhile there is TWO Red lights display in the receiver. Press “HEAT” button
again, the unit will switch middle power to high power. Meanwhile there is THREE Red lights display in the
receiver. Press “HEAT” button again, the unit will switch heating mode to cool mode and the red lights display
change to green light in the receiver. So FOR THREE PHASES MODEL when the unit is working at cool
mode, press “HEAT” button can switch air curtain working under the cycle of heating low power, heating
middle power, heating high power or cool mode.
d. When the unit works at cool mode, press “ON/OFF” button to turn OFF the unit.
e. When the unit works at heating mode, press “ON/OFF” button, receiver receives the signal with the sound of
“beep” and switch to cool mode at high speed, the indication light turns to green flicker light. The unit will
continue to work in cool mode for 3 minutes and then stop. (This is to ensure the heater is been cooled down
and has 3 minutes delay stop).

6.2. Controlled by the control panel in the unit is the same function as 6.1.
6.3. Overheat protection:
When the air curtain works at heating mode, there is overheat protection. When the heater temperature is
overheating, heating mode will stop and switch to cool mode automatic, at the same time the indication light
change to green light. When the temperature drop down to a certain temperature, if want the unit to work at
heating mode, press “HEAT” button to continue to work heating mode.
7、CAUTIONS
a)、Use the unit at the rate voltage and frequency indication on the nameplate.
b)、Disconnect power source before unit operation.
c)、Routing maintenance must be done every year.
d)、Never use petrol,benzese,thinner or any other such chemical for clearing the unit.
e)、Don’t allow water or anything enter the motor.
f)、When power supply comes from socket, the plug must accord with IEC335-1.When the
power cord is connected with charging line directly,all polarity switch that the contact gap is
3mm at least must be installed in the charging line.