turck TBIL-S Series User manual

Your Global Automation Partner
Instructions for Use
TBIL-S…
Compact IO Hubs with IO-Link

2Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

V 01.01 | 2018/11 3
Table of Contents
1 About These Instructions............................................................................................................... 5
1.1 Explanation of Symbols Used .................................................................................... 5
1.2 Additional Documents ................................................................................................5
2 Notes on the Product...................................................................................................................... 6
2.1 Product Identification ................................................................................................. 6
2.2 Scope of Delivery.......................................................................................................... 6
2.3 Legal Requirements ..................................................................................................... 6
2.4 Manufacturer and Service........................................................................................... 6
3 For Your Safety................................................................................................................................. 7
3.1 Intended Use ................................................................................................................. 7
3.2 General Safety Instructions ........................................................................................ 7
4 Product Description ........................................................................................................................ 8
4.1 Device Overview........................................................................................................... 8
4.1.1 Display Elements...........................................................................................................................8
4.2 Properties and Features.............................................................................................. 9
4.3 Functions and Operating Modes...............................................................................9
5 Mounting.........................................................................................................................................10
5.1 Grounding the device................................................................................................10
6 Connecting .....................................................................................................................................11
6.1 Connecting the supply voltage and IO-Link .........................................................11
6.2 Connecting Digital Sensors and Actuators ...........................................................12
7 Parameterizing and Configuring ...............................................................................................14
7.1 Parameters...................................................................................................................14
8 Operating ........................................................................................................................................22
8.1 Process Input Data .....................................................................................................22
8.2 Process Output Data..................................................................................................25
8.3 LED Displays ................................................................................................................25
8.3.1 IO-Link............................................................................................................................................ 25
8.3.2 Channel-LEDs .............................................................................................................................. 25
8.4 Evaluating Diagnostic Data......................................................................................26
8.5 IO-Link Events .............................................................................................................27
8.6 IO-Link Error Codes ....................................................................................................28
9 Troubleshooting ............................................................................................................................29
10 Maintenance...................................................................................................................................30
11 Repair...............................................................................................................................................30
11.1 Returning Devices ......................................................................................................30
12 Disposal ...........................................................................................................................................30
13 Technical Data ...............................................................................................................................31
13.1 General Technical Data .............................................................................................31
13.2 TBIL-S…-8DIP..............................................................................................................32
13.3 TBIL-S…-8DXP.............................................................................................................33
14 Appendix: Declaration of Conformity .......................................................................................34

Table of Contents
4Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

V 01.01 | 2018/11 5
1 About These Instructions
These operating instructions describe the structure, functions and the use of the product and
will help you to operate the product as intended. Read these instructions carefully before using
the product. This is to avoid possible damage to persons, property or the device. Retain the in-
structions for future use during the service life of the product. If the product is passed on, pass
on these instructions as well.
1.1 Explanation of Symbols Used
The following symbols are used in these instructions:
DANGER
DANGER indicates a dangerous situation with high risk of death or severe injury if
not avoided.
WARNING
WARNING indicates a dangerous situation with medium risk of death or severe in-
jury if not avoided.
CAUTION
CAUTION indicates a dangerous situation of medium risk which may result in minor
or moderate injury if not avoided.
NOTICE
NOTICE indicates a situation which may lead to property damage if not avoided.
NOTE
NOTE indicates tips, recommendations and useful information on specific actions
and facts. The notes simplify your work and help you to avoid additional work.
uCALL TO ACTION
This symbol denotes actions that the user must carry out.
aRESULTS OF ACTION
This symbol denotes relevant results of actions.
1.2 Additional Documents
The following additional documents are available online at www.turck.com:
nData sheet
nDeclaration of Conformity
nIO-Link devices commissioning manual

Notes on the Product
Manufacturer and Service
6Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
2 Notes on the Product
2.1 Product Identification
These instructions are valid for the following devices:
nTBIL-S3-8DIP
nTBIL-S3-8DXP
nTBIL-S4-8DIP
nTBIL-S4-8DXP
2.2 Scope of Delivery
The scope of delivery includes:
nI/O hub
nDummy plugs for M8 or M12 connectors
nLabel clips
2.3 Legal Requirements
The device is subject to the following EC directives:
n2014/30/EU (electromagnetic compatibility)
n2011/65/EU (RoHS II Directive)
2.4 Manufacturer and Service
Hans Turck GmbH & Co. KG
Witzlebenstraße 7
45472 Muelheim an der Ruhr
Germany
Turck supports you with your projects, from initial analysis to the commissioning of your applic-
ation. The Turck product database contains software tools for programming, configuration or
commissioning, data sheets and CAD files in numerous export formats. You can access the
product database at the following address: www.turck.de/products
For further inquiries in Germany contact the Sales and Service Team on:
nSales: +49 208 4952-380
nTechnology: +49 208 4952-390
Outside Germany, please contact your local Turck representative.

V 01.01 | 2018/11 7
3 For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still
exist. Observe the following warnings and safety notices to prevent damage to persons and
property. Turck accepts no liability for damage caused by failure to observe these warning and
safety notices.
3.1 Intended Use
These devices are designed solely for use in industrial areas.
The block modules of the TBIL-S… series are IO-Link devices and serve as I/O hub between field
devices (sensors/actuators) and the IO-Link master. The hubs provide 8 digital I/O channels.
Depending on the device type, the devices provide 8 digital inputs for connecting digital
sensors or 8 digital DXP channels for connecting digital sensors and actuators. In the devices
with DXP channels, each I/O channel can be used as digital in- or output without additional
configuration. The device is designed in IP67/IP69K and can be mounted directly in the field.
The devices may only be used as described in these instructions. Any other use is not in accord-
ance with the intended use. Turck accepts no liability for any resulting damage.
3.2 General Safety Instructions
nThe device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
nThe device may only be used in accordance with applicable national and international regu-
lations, standards and laws.
nThe device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.

Product Description
Device Overview
8Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4 Product Description
The I/O hubs of the TBIL-S… series connect up to 8 digital sensors or up to sensors or actuators
with one IO-Link master port.
4 device types are available:
nTBIL-S3-8DIP: 8 digital input channels, 8 M8 connectors
nTBIL-S3-8DXP: 8 digital I/O, 8 M8 connectors, each channel can be used as digital in- or
output without additional configuration
nTBIL-S4-8DIP: 8 digital input channels, 4 M12 connectors
nTBIL-S4-8DXP: 8 digital I/O, 4 M12 connectors, each channel can be used as digital in- or
output without additional configuration
The devices are designed in a fully encapsulated housing with degree of protection IP67/IP69K.
4.1 Device Overview
16 [0.63] 22.2 [0.87]
26.8 [1.06]
31.6 [1.24]
132 [5.20]6.1 [0.24]
144 [5.67]
M12 x 1
Ø 4.3 [0.17]
Ø 4.3 [0.17]
C3 C2
C7 C6
C1
C5
C0
C4
Fig.1: Dimensions TBIL-S3-…
16 [0.63] 24.9 [0.98]
26.8 [1.06]
31.6 [1.24]
132 [5.20]6.1 [0.24]
144 [5.67]
M12 x 1
Ø 4.3 [0.17]
Ø 4.3 [0.17]
C3 C2 C1 C0
Fig.2: Dimensions TBIL-S4-…
4.1.1 Display Elements
The device has the following LED indicators:
nIO-Link communication
nI/O status

V 01.01 | 2018/11 9
4.2 Properties and Features
nFibre-glass reinforced housing
nShock and vibration tested
nFully potted module electronics
nProtection class IP67/IP69K
nIO-Link diagnostics for short-circuit and supply over- and undervoltage
nTBIL-S3-…: 1 digital input channel or 1 universal digital channel per M8 connector
TBIL-S4-…: 2 digital input channels or 2 universal digital channels per M12 connector
nmetal connectors
4.3 Functions and Operating Modes
The I/O hubs with IO-Link of the TBIL-S series connect up to 8 digital sensors or 8 digital sensors
and actuators with one IO-Link master port.
The device provides diagnostics for power supply and short circuit of the sensors and actuators
on the IO-Link master.

Mounting
Grounding the device
10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5 Mounting
The device is mounted via four M4 screws on a flat and pre-drilled mounting surface.
Attach the module to the mounting surface with two M4 screws. The maximum tighten-
ing torque for the screws is 1.3 Nm
31.8
132
M4 (2 x)
max. 1.3 Nm
Fig.3: Mounting the device to a mounting surface (example: TBIL-S3-…)
5.1 Grounding the device
When mounting on a mounting plate, fasten the device with an M4 metal screw.
aThe FE connection of the device is connected to the reference potential of the installation
via the M4 metal screw.

V 01.01 | 2018/11 11
6 Connecting
WARNING
Penetration of liquids or foreign objects through leaking connections
Danger to life due to malfunction
Fasten the M12 connectors with a tightening torque of 0.8 Nm.
Always seal unused connectors with respective protection caps.
6.1 Connecting the supply voltage and IO-Link
WARNING
Defective power supply unit
Danger to life due to dangerous voltages on touchable parts
Only use SELV or PELV power supplies in accordance with EN ISO 13849-2, which
allow a maximum of 60 VDC or 25 VAC in the event of a fault.
For the connection to IO-Link and the supply voltage, a 5-pole M12 connector is available.
Fig.4: M12 connector for the connection to IO-Link
Connect the device to the supply voltage and IO-Link according to the pin assignment.
4
13
2
5
1 = 24 VDC
2 = n.c.
3 = GND
4 = C/Q (IO-Link)
5 = n.c.
Fig.5: Pin assignment IO-Link

Connecting
Connecting Digital Sensors and Actuators
12 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
6.2 Connecting Digital Sensors and Actuators
Connecting Digital Sensors and Actuators – TBIL-S3-…
For connecting digital sensors and actuators, 3-pin M8 connectors are available.
Fig.6: TBIL-S3-…: M8 connector for connecting digital sensors and actuators
Connect the sensors to the device according to the pin assignment.
3 1
4
v
1 = VAUX
3 = GND
4 = Signal In
C0…C7
Fig.7: Pin assignment TBIL-S3-8DIP
Connect the sensors and actuators to the device according to the pin assignment.
3 1
4
v
1 = VAUX
3 = GND
4 = Signal In/Out
C0…C7
Fig.8: Pin assignment TBIL-S3-8DIP

V 01.01 | 2018/11 13
Connecting Digital Sensors and Actuators – TBIL-S4-…
For connecting digital sensors and actuators, 5-pin M12 connectors are available.
Fig.9: TBIL-S4-…: M12 connector for connecting digital sensors and actuators
Connect the sensors to the device according to the pin assignment.
4
13
2
5
v1 = VAUX
2 = Signal In
3 = GND
4 = Signal In
5 = FE
C0...C3
Fig.10: Pin assignment TBIL-S4-8DIP
Connect the sensors and actuators to the device according to the pin assignment.
4
13
2
5
v1 = VAUX
2 = Signal In/Out
3 = GND
4 = Signal In/Out
5 = FE
C0...C3
Fig.11: Pin assignment TBIL-S4-8DXP

Parameterizing an Configuring
Parameters
14 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7 Parameterizing and Configuring
7.1 Parameters
IO-Link object directory – ISDU device parameters: Direct Parameter Page
ISDU
Index
Hex.
(Dec.)
Sub index Object name Access Length
[Byte]
Meaning/default value
0x00
(0)
Direct Parameter Page 1 read
only
16
0x07 Vendor ID read
only
2 0x013D
(ID for Turck)
0x08
0x09 Device ID read
only
3 e.g. TBIL-S3-8DXP:
0x1E2213
0x0A
0x0B
IO-Link object directory – ISDU device parameters: Identification
ISDU
Index
Hex.
(Dec.)
Object name Access Length
[Byte]
Meaning/
default value
Comment
0x10
(16)
Vendor
Name
read
only
16 Turck
0x11
(17)
Vendor Text read
only
32 www.turck.com
0x12
(18)
Product
Name
read
only
32 e.g. TBIL-S3-8DXP
0x13
(19)
Product ID read
only
16 Ident no. of the device:
e.g. 100002595 for
TBIL-S3-8DXP
0x14
(20)
Product Text read
only
32 I/O hub
0x15
(21)
Serial
Number
read
only
16 Sequential
serial number
0x16
(22)
Hardware ID read/
write
8 Hardware ID of the
device, e.g. V1.0
0x17
(23)
Firmware
Revision
read
only
16 Firmware version of
the device, e.g.
V1.0.7.0
0x18
(24)
Application
Specific Tag
read/
write
32 Default "***" Customer-specific or
application-specific
data can be stored in
this field.
0x19
(25)
Function Tag read/
write
32 Default "***" The application-spe-
cific device function
can be stored in this
field.

V 01.01 | 2018/11 15
ISDU
Index
Hex.
(Dec.)
Object name Access Length
[Byte]
Meaning/
default value
Comment
0x1A
(26)
Location Tag read/
write
32 Default "***" The application-spe-
cific installation loca-
tion of the device can
be stored in this field.
IO-Link object directory – ISDU device parameters: Preferred Index (parameters and
diagnostics of the digital in- and outputs)
ISDU
Index
Hex.
(dec.)
Object name Access Length
[Byte]
Meaning
0x40
(64)
Parameter ID read/
write
4 Customer-specific ID, for free use
0x41
(65)
Inverting
Input
read/
write
1 Invert digital input
0x42
(66)
Activate
Output
read/
write
1 Activate output
only for TBIL-S…-8DXP
0x43
(67)
Impulse
Stretching
Input
read/
write
8 Pulse stretching input
0x44
(68)
Short Circuit
Recovery
read/
write
1 Manual output reset after overcurrent
only for TBIL-S…-8DXP
0x45
(69)
Failsafe read/
write
2 Output After Error
only for TBIL-S…-8DXP
0x46
(70)
Under
Voltage
Diagnostics
read/
write
2 Undervoltage Diagnosis (defining the
threshold value for the undervoltag dia-
gnostics)
Diagnostics
0x50
(80)
Supply Error read
only
2nOver- and undervoltage supply
nOvercurrent VAUX connector C0…C7 or
C0…C3
0x51
(81)
Output Short
Circuit
read
only
1 Overcurrent output 0…7
only for TBIL-S…-8DXP

Parameterizing an Configuring
Parameters
16 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Invert Digital Input – 0x41 (65), Sub Index 0
This parameter inverts the state of the digital input in the process image.
Format Length
Byte 1 byte 1 bit per channel
Default values are shown in bold.
Value Meaning
0 No
1 Yes Input signal inverted
nTBIL-S3-8DIP
nTBIL-S3-8DXP
Byte 0
Bit offset
76543210
C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4
nTBIL-S4-8DIP
nTBIL-S4-8DXP
Byte 0
Bit offset
76543210
C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4
NOTE
This parameter can also be set for all connectors of the module via the IODD.

V 01.01 | 2018/11 17
Activate Output – 0x42 (66), Sub Index 0
this parameeter activates or deactivates the output function of the digital channel.
Format Length
Byte 1 byte 1 bit per channel
Default values are shown in bold.
Value Meaning
0 No Output function deactivated, channel can only be used as
input
1 Yes Output function activated, channel can be used as in- or
output
nTBIL-S3-8DXP
Byte 0
Bit offset
76543210
C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4
nTBIL-S4-8DXP
Byte 0
Bit offset
76543210
C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4
NOTE
This parameter can also be set for all connectors of the module via the IODD.

Parameterizing an Configuring
Parameters
18 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Pulse Stretching Input – 0×43 (67)
This parameter defines the duration of the pulse stretching for digital input edges in multiples
of 10 ms. This allows that even short signals with longer PLC cycle times can be detected.
Format Length
Array of Bytes 8 byte 1 byte per channel
Default values are shown in bold.
Value Meaning
0 disabled Pulse stretching deactivated
1 1…255 Pulse stretching input [*10 ms]
nTBIL-S3-8DIP
nTBIL-S3-8DXP
Bit offset
0 8 16 24 32 40 48 56
Sub index
87654321
C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4
nTBIL-S3-8DIP
nTBIL-S3-8DXP
Bit offset
0 8 16 24 32 40 48 56
Sub index
16 15 14 13 12 11 10 9
C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4
NOTE
This parameter can also be set for all connectors of the module via the IODD.

V 01.01 | 2018/11 19
Manual Output Reset after Overcurrent – 0x44 (68), Sub Index 0
This parameter defines if a manual reset is necessary after an overcurrent occurred at the digital
channel.
Format Length
Byte 1 byte 1 bit per channel
Default values are shown in bold.
Value Meaning
0 No Automatic recovery mode
1 Yes Controlled recovery mode (output has to be reset manually)
nTBIL-S3-8DXP
Byte 0
Bit offset
76543210
C7P2 C6P4 C5P4 C4P4 C5P2 C2P4 C1P4 C0P4
nTBIL-S4-8DXP
Byte 0
Bit offset
76543210
C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4
NOTE
This parameter can also be set for all connectors of the module via the IODD.

Parameterizing an Configuring
Parameters
20 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Output After Error – 0x45 (69), Sub Index 0
This parameter defines the behavior of the output in case of an interruption of the IO-Link com-
munication.
Format Length
Array of Bytes 2 byte 2 bit per channel
Default values are shown in bold.
Value Meaning
00 0 Set output to 0
01 1 Set output to 1
10 Current value Hold current value
11 reserved
nTBIL-S3-8DXP
Byte 1 Byte 0
Bit offset Bit offset
64206420
C7P4 C6P4 C5P4 C4P4 C3P4 C2P4 C1P4 C0P4
nTBIL-S4-8DXP
Byte 1 Byte 0
Bit offset Bit offset
64206420
C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4
NOTE
This parameter can also be set for all connectors of the module via the IODD.
Other manuals for TBIL-S Series
1
This manual suits for next models
4
Table of contents
Other turck Switch manuals

turck
turck IM1-451EX Series User manual

turck
turck TBEN-L SE-M2 Series User manual

turck
turck TBEN-L-SE-U1 Series User manual

turck
turck TBIL-S Series User manual

turck
turck TBIP-L 16DXP-AUX Series User manual

turck
turck FMX-IM-3UP63X User manual

turck
turck TBIL-M1-16DXP User manual

turck
turck TBIL-M1-16DIP User manual
Popular Switch manuals by other brands

Brocade Communications Systems
Brocade Communications Systems FastIron SX 800 Diagnostic manual

WTI
WTI IPS-800 user guide

StarTech.com
StarTech.com VS415RVGA instruction manual

gofanco
gofanco Prophecy PRO-KVMDP-4P user guide

Mellanox Technologies
Mellanox Technologies Mellanox SX1018 release note

SEIAOTEK
SEIAOTEK ST-G16T user manual