Tynetec ZXT422 User manual

DocNo.FM0456issueFPage1
“A” “A”
169MHzTelecareDevices
CarbonMonoxideDetector
__________________________________________________________________________________________________________
CompatiblewithReachat‐homealarms,Adventxtwardencall,
AltecResponseandTouchsafeProNursecallsystems
COalarmactivatesonTimeWeightedAverage;
50ppm60‐90mins,100ppm10‐40minsor300ppm0‐3mins
85dB@3msounder
Indicatorlights:greenpower,redalarm&yellowfault
LongLifeLithiumbatteries
Lowbatterywarning
Test&Hushbutton
ComplieswithBSEN50291:2001
Dimensions:135x105x43mm(HxWxD)
Weight:260grams
ProductCode:ZXT422
WhereshouldCarbonMonoxideDetectorsbefitted?
CarbonMonoxide(CO)detectorsshouldbefittedinroomswithafuelburningappliancesuchasacentralheatingboiler
orgasfireandwherealotoftimeisspente.g.thekitchen,livingroomorbedroom.
Theyshouldnotbefittedinthebathroomorareassubjecttosteamorcondensation.
ChoosingaLocation
WhenfittedinthesameroomastheappliancetheCOdetectorshouldbewallmountedabovetheheightofanywindowordoor
butatleast150mmbelowceilinglevel.Ifceilingmounteditshouldbeatleast300mmfromanywall.Ineithercasethedetector
shouldbebetween1and3metresfromtheappliance.
Whenfittedinroomsremotefromtheappliancethedetectorshouldbewallmountedclosetothebreathingzoneofthe
occupant;inthelivingroomthiswillbeaboutheadheightofaseatedperson,inthebedroomthiswillbeaboutpillowheight.
TheCOdetectorshouldnotbelocatedinanenclosedspace,insideacupboard,behindacurtain,directlyabovethecookeror
sink,indraughtyareasnexttoadoororwindowornearanextractorfan.
TypicalToolsRequired
Becarefulwhenusingstepladders–alwaysfacethedirectionyouareworking.
Alwaysmakesurethecorrectdrillbitsandscrewdriversareused.
Installation–UsingScrewFixings(Recommended)
1. Removethetopcoverbypressingandslidingupwardsas
showninthediagramalongside.
2. Fixtherearsectiontothewallusingthescrewsandplugs
providedthrough2screwfixingholes.
3. Smoothlywithdrawthered“PULL”tabtoconnectthe
batteriesthenrefitthetopcover.
Installation–UsingSelfAdhesivePads
1. Selectthebestlocationwherethewallisclean,dryandeven.
IMPORTANT:forgoodadhesionthesurfacemustbeflat.
2. Cutoneoftheselfadhesivepadsinhalfandfixthe3pieces
totherearfaceoftheCOdetectorasshownalongside.
3. Removethebackingtapeandpressfirmlyagainstthewall
ensuringitisstucksecurely.
4. Followsteps1&3ofthescrewfixinginstructionsabove
toremovethetopcoverandconnectthebatteries.
SCREWFIXING HOLESPRESSHEREANDSLIDEUPWARDS
TOREMOVETOPCOVER
PULL
CUTBLACKWIRETO
DEACTIVATEATENDOFLIFE
PULLTABTO
CONNECT
BATTERIES
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk
REARVIEW
SHOWINGSELF
ADHESIVEPAD
POSITIONING

DocNo.FM0456issueFPage2
Activating&DeactivatingtheCODetector
RemovethetopcoverandwithdrawtheredPULLtabtoconnectthebatteriesandactivatethedetector.
TheGREEN,REDandYELLOWlightswillflashinsequence.TheGREENlightwillblinkevery45secondswhenactivated.
TheCOdetectorcannotbeturnedoff.WhenunitisapproachingitsendoflifeitwillemitabeepandflashtheGREENlightsimultaneouslyevery
45seconds.RemovethetopcoverandcuttheBLACKWIREtodeactivate(seedrawingabove).
TestingtheCODetector
PressandholdtheTEST&HUSHbuttonforatleast5seconds,
theGREENlightwillflashandthehornwillsound.
TheTEST&HUSHbuttonmustbepressedwhenregisteringtheCOdetector
ontothewardencallsystem,at‐homealarmorNursecallsystem.
Seethefollowingpagesforhowtoputeachoftheseproductsintoregistrationmode.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment.
Alwaystakecareduringinstallationandperformseveraltestcalls.
MaskTime&BatteryTest
COdetectorsincludea15minutemasktimetopreventalarmcallsre‐reporting
andanEngineersmaskreset/batterytestfunction.
Whenthedetectorisactivatedthealarmcallwillbetransmittedonce,nofurther
transmissionswilloccurfor15minutesgivingtimeforthecauseofthealarmtoclear.
Engineersmaskresetfunction;openthecover,pressandholdBUTTON1onthetransmitter
for2secondsuntiltheredlightflashesonce.Afterashortdelaytheredlightwillflashoncemore
toindicatethemasktimeisresetandthebatterypowerisOK.Iftheredlightflashesseveraltimesthebatterypowerislow.
InCaseofCarbonMonoxideAlarm
IfapotentiallydangerouslevelofcarbonmonoxideisdetectedtheREDlightwillflashandtheaudiblealarmwillsound.
Openwindowsanddoorstoventilatethearea
PresstheTEST&HUSHbuttontosilencethealarmfor4minutes
IfthealarmdoesnotsilencethelevelofCOisdangerouslyhigh(300ppm)
Ifthealarmdoesnotre‐soundafter4minutesitissafeforaqualifiedpersontofindthecauseofthealarm.
Ifthealarmcontinuesturntheapplianceoffanddonotuseuntilithasbeencheckedbyaqualifiedperson.
Getmedicalhelpforanyonesufferingheadachesornausea,advisethatcarbonmonoxidepoisoningissuspected.
AlarmMemory
IftheREDlightflashes2timesevery40secondsa50ppmlevelofCOhasbeendetectedforatleast90minutes.
IftheREDlightflashes4timesevery40secondsa100ppmlevelofCOhasbeendetectedforatleast40minutes.
IftheREDlightflashes8timesevery40secondsa300ppmlevelofCOhasbeendetectedforatleast3minutes.
PressandholdtheTEST&HUSHbuttonfor20secondstoclearthememory.Getallappliancescheckedbyaqualifiedperson.
InCaseofFault
IftheunitbeepsandtheYELLOWlightblinkssimultaneouslyevery45secondsthereisafaultwiththesensor.
Theunitisprobablydefectiveandmustbereplaced.
FalseAlarms
Itispossibletobaccosmoke,householdcleaningagents,paint,
airfresheners,insectsprays,bleaches,hairsprays,polishes
orotheraerosolscancausefalsealarms.
Cleaning&Decorating
Itisrecommendedtocleanthedetectorperiodicallyusingthenozzleattachmentonavacuumcleanerto
removedust,insectsandcobwebsfromthecoverslots.
Thedetectorcanbewipedcleanwithadampcloth,neverusedetergentsorpolishetc.
Avoidsprayinganyaerosolsnearthedetector.
NeverpainttheCOdetectoritself.WhendecoratingcovertheCOdetectorwithaplasticbagtoavoid
contaminationfromwaterordust.
BatteryLife
Thetransmitterbatteryischeckedonceaday,ifthevoltagefallsandstaysbelowapresetlevelfor7consecutivedaysalowbatteryalertis
automaticallytransmitted.OncealowbatterycallisreceivedtheCOdetectorshouldbereplacedwithin7days.
DetailedinformationonbatterymanagementforallTynetec/Aidcallproductsisavailable‐requestDocNo.FM0630.
TEST&HUSH
BUTTON
PRESSANDHOLD
BUTTON1TORESET
THEMASKTIME
THEREDLIGHT
WILLFLASH

DocNo.FM0456issueFPage3
RegisteringaCODetectorontoaReachat‐homealarmunit
1.PuttheReachunitintoradiodevicelearnmode…
2.ActivatetheCOdetector…
3.Exitradiodevicelearnmode…
4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall,activatetheCOdetectorandconfirmtheyreceivea
carbonmonoxidealarmcall.
DeletingaCODetectorfromaReachat‐homealarmunit
Enter1670usingthekeypadontherearoftheReachunit–thefrontlightwillFLASHFASTGREENandtheunitwillannounce
“ProgramMode‐Ready”.
Enter#041andtheReachwillannounce“DeleteRadioDevice”followedbya“Beep”.
Enterthe8digitCOdetectorIDtobedeleted;afterthe“Beep”press#toexit.
PressthekeytoexitProgramMode;theunitwillsounda“Double‐Beep”andthefrontlightwillreturntoSTEADYGREEN.
The8digitIDcanbefoundonalabelonthebackoftheCOdetector–itwillalwaysstartwith49xxxxxx
TheinstructionsgivenaboveforthestandardReachproductalsoappliestotheReachPlus,ReachPlusGSM
andReachUltramodels.Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation
onprogrammingandtestingradiodevices.
“Trigger
Radio
Device”
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounce“TriggerRadioDevice”.
Younowhave1minutetoactivatetheCOdetector.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
PressandholdtheTEST&HUSHbuttonforatleast5seconds.
Thehornwillsound,thelightwillflashGREENandtheReach
willannounce“CarbonMonoxide”.
*Note:iftheTEST&HUSHbuttonhasbeenpressedinthelast
15minutesyou’llhavetoresettheMASKTIME–seepage2.

DocNo.FM0456issueFPage4
RegisteringaCODetectorontoanAdventxtwardencallsystem
1.PuttheAdventxtsystemintoradiodevicelearnmode…
2.ActivatetheCOdetector…
3.ExittheAdventxtsystemradiodevicelearnmode…
4.ActivatetheCOdetectorandcheckacarbonmonoxidealarmcallisreportedonthewardencallsystem.
DeletingaCODetectorfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5001followedbythekey.
EntertheflatnumbertheCOdetectorisbeingdeletedfromfollowedbythekey.
ActivatetheCOdetectortobedeleted.
Waitforthe“PendantDisabled–EnterFlat”prompt.
Pressthe#keyandwaitforthe“Ready”prompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogrammingandtestingradiodevices.
UsingtheManager’sDECTtelephone;
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5000followedbythekey.
EntertheflatnumbertheCOdetectorisbeinginstalledin
followedbythekey.
Younowhave1minutetoactivatetheCOdetector.
“Ready”
UsingtheManager’sDECTtelephone;
Pressthe#keyandwaitforthe“Ready”prompt.
PresstheLINEkeytocleartheconnectionandthewardencallsystemis
nowbackinnormaloperatingmode.
PressandholdtheTEST&HUSHbuttonforatleast5seconds,thehornwill
soundandthelightwillflashGREEN.
Waitforthe“EnterLocationCode”promptthenpress0(nolocation)followed
bythekey.
Waitforthe“PendantEnabled–EnterFlat”prompt.
*Note:iftheTEST&HUSHbuttonhasbeenpressedinthelast15minutesyou’ll
havetoresettheMASKTIME–seepage2.
“Ready”

DocNo.FM0456issueFPage5
RegisteringaCODetectorontoanAltecResponselocalcareralarmunit
1.PuttheAltecResponseunitintoradiodevicelearnmode…
2.ActivatetheCOdetector…
3.ExittheAltecResponseradiodevicelearnmode…
4.ActivatetheCOdetectorandcheckacarbonmonoxidealarmcallisdisplayedontheAltecResponseunit.
DeletingaCODetectorfromanAltecResponselocalcareralarmunit
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplaythemainmenu
PressENTERtoselectRadioDevices
PressthekeytoselectDeleteDevicethenpressENTER
Thedisplaywillpromptyouto“TriggertheSensor”
ActivatetheCOdetectortobedeleted‐thedisplaywillshowthedevicetypeandits8digitIDnumber
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Ifit’sNOTthedeviceyouactivatedpresstheENTERkeytoselectRejectthentryagain
ToexitthemodeselectExitthenpresstheENTERkey.
RefertotheAltecResponseinstallationguide(DocNo.FM0548)providedwiththeportablealarmunitfor
moreinformationonprogrammingandtestingradiodevices.
PressandholdtheTEST&HUSHbuttonforatleast5seconds,thehornwillsound
andthelightwillflashGREEN.
ThedisplaywillshowCOAlarmandtheCOdetector8digitIDnumber.
ChecktheIDiscorrect,pressthekeytoselectAcceptthenpressENTER.
Note:ifanotherdevicehasbeenpicked‐uppressENTERtoRejectandtryagain.
ThedisplaywillshowFlat,usethe&keystochoosethedwellingtype.
PressthekeytoselectNo:000000thenpresstheENTERkey.
Usethe&keystoselecteachdigitoftheflatnumberandthe&keys
tomovebetweendigitsthenpresstheENTERkey.
PresskeyseveraltimestoselectExitthenpresstheENTERkey.
Thedisplaywillpromptyouto“TriggertheSensor”again.
*Note:iftheTEST&HUSHbuttonhasbeenpressedinthelast15minutesyou’ll
havetoresettheMASKTIME–seepage2.
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplay
themainmenu.
PressENTERtoselectRadioDevices
PressENTERtoselectLearnDevice
Thedisplaywillpromptyouto“TriggertheSensor”.
Younowhave20secondstoactivatetheCOdetector.
FromtheLearnDevicemenuselectExitthenpressENTER.
FromtheRadioDevicesmenuselectExitthenpressENTER.
Thedisplaywillreturntothewake‐upscreenandgoblankafter10seconds.
TheAltecResponseisnowbackinnormaloperatingmode.
tynetec
tynetec

DocNo.FM0456issueFPage6
RegisteringaCODetectorontoaTouchsafeProNursecallsystem
1.PuttheTouchsafeProMasterPanelintoTelecareregistrationmode;touchthescreenandLogonasanEngineeroraManager
(passwordrequired),thenfromthemainmenupagetouchtheTelecarebuttontoopenthescreenshownbelow…
2.EntertheCOdetectorID…
3.PresstheClosebuttontoexitTelecaremodeandtheNursecallpanelisnowbackinnormaloperatingmode.
4.ActivatetheCOdetectorandcheckthecallisdisplayedontheNursecallpanellikethis…
ThescreenbannerisredforaCOalarmcall(Touchthebannertodisplaynotes).
Acarbonmonoxidealarmcallcannotbeacceptedorsilencedfromthescreen.
YoumustvisittheappropriateNursecallCallPointtocancelthecall.
DeletingaCODetectorfromaTouchsafeProNursecallsystem
SelecttheCOdetectorIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixedwitha“T49”).
DetailsoftheCOdetectorselectedwillbedisplayedintheRoom,HouseCodeandIDboxesbelow.
IfthedetailsshownarecorrectpresstheDeletebutton.
PresstheClosebuttontoexit.
RefertotheTouchsafeProDisplayPaneluserguide(DocNo.FM5505)providedwiththeNursecallsystemfor
moreinformation.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
The8digitIDisprintedonalabelontherearoftheCOdetector.
Note:thisIDwillalwaysstartwith49xxxxxx.
TouchtheAddTelecareDeviceboxthenusetheon‐screenkeypadtoentertheID.
Hint:enterazoneintheFilterboxtonarrowthesearchfortheroom(seebelow).
SelecttheusersCallPointIDfromtheRoompull‐downlistboxthenpressSave.
Note:thisistheroomunitthatwillbewillbeusedtocancelthecall.
Usekeypadtoenter
8digitIDhere
Selecttherelevant
CallPointIDhere
Savewhendone
Closetoexitmode
On‐screenkeypad
CALLING
CANCEL
HC345ID001
PresstheLIGHTGREY
buttontocancelthecall
ZXT422W63923
Ser:10154255
ID:49040292
EE0755V1.04A
MC
Table of contents
Other Tynetec Security Sensor manuals
Popular Security Sensor manuals by other brands

Franke
Franke 2030019212 Installation and operating instructions

DEFA
DEFA LedgeCircle RF manual

Broadcast Tools
Broadcast Tools Silence Sentinel Basic G2 Installation and operation manual

B.E.G.
B.E.G. LUXOMAT PD3-1C Installation and operating instruction

Cooper Menvier
Cooper Menvier Scantronic 714r manual

Milesight
Milesight VS121 user guide

Kistler
Kistler 8852A Series instruction manual

Zeo Detect
Zeo Detect POOL FINDER PLUS user manual

Elcometer
Elcometer 266 user guide

Waters
Waters ACQUITY UPLC Operator's, overview and maintenance guide

Infinite
Infinite L-com SRCN-C413-2 user guide

steute
steute Ex RC Si M30-3G/D Mounting and wiring instructions