Tynetec ZXT413 User manual

DocNo.FM0795issueBPage1
tynetec
tynetec
tynetec
169MHzTelecareDevices
FallDetector(v2)
__________________________________________________________________________________________________________
CompatiblewithReachat‐homealarms,Adventxtwardencall,
AltecResponseandAidcallTouchsafeProNursecallsystems
3impactsensitivitysettings
Vibrationalertandtri‐colourLEDindicatorlight
Auto‐canceloption
Alarmcallbutton
LonglifeLithiumbatterywithlowbatterywarning
Waterresistant:IP67
Dimensions:57mmx34mmx16mm(HxWxD)
Weight:23grams
ProductCode:ZXT413
HowdoestheFallDetectorwork?
Wornonthewrist,thefalldetectorautomaticallydetectsachangeinaccelerationthatisrelatedtotripsandstumbles,itthen
monitorsforthesubsequentimpactassociatedwithafall.
Ifafallisautomaticallydetected,theunitcanbesettovibratetoalerttheuserthatanalarmcallisabouttobetransmitted
(vibratealerton/offisanoptionalsetting).Analarmcallwillbetransmittedaftera10seconddelayunlesscancelledbytheuser.
Iftheusershakestheirwristwithin10secondsofafallbeingdetectedthealarmcallcanbecancelledautomatically(auto‐cancel
isanoptionalsetting).WhenanalarmcalliscancelledthelightwillflashGREEN.
IfnocancellationactionistakenthelightwillflashREDandanalarmcallwillbetransmitted.
ThelargeSILVERbuttoncanbepressedtoraiseanalarmcallatanytime,ifitispressedwithin10secondsofafallbeingdetected
afallalarmwillbetransmittedimmediately–thelightwillflashRED.
Duetothecomplexnatureoffallsitmaynotbepossibleforthefalldetectortoautomaticallydetectallfalls.
Usersshouldbeadvisedthatiftheyareable,topressthesilverbuttononthefalldetectoriftheyneedhelp.
WearingOptions
Thefalldetectorisnormallywornonthewristlikeawatch.Tominimise
falsealarmsitshouldbewornontheleastdominantside;i.e.aright
handedpersonshouldwearitontheirleftwristandvice‐versa.
Itcanalsobewornonthewaistbandofaskirtortrousers
byfittingthebeltclipoptionsupplied.
Fittingthebeltclipoption‐firstremovethewriststrapby
unclippingthe2blackplasticinsertsfromtheback.
Fitthebeltclipparttothetopandblankingparttothe
bottomofthefalldetector–seealongside...
FallDetectorFeatures
BLACKPROGRAMMODEBUTTON
GREENAMBERREDINDICATORLIGHT
SILVERALARMCALLBUTTON
BatteryLife
Thebatteryconditionischeckedeveryday,ifthevoltagefallsandstaysbelowapresetlevelfor7consecutivedaysalowbattery
alertisautomaticallytransmitted.Oncealowbatterycallisreceivedthefalldetectorshouldbereplacedwithin7days.
FalldetectorsmustbereturnedtoTynetec/Aidcallforbatteryreplacement.
DetailedinformationonbatterymanagementforallTynetec/Aidcallproductsisavailable–requestDocNo.FM0630.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment‐alwaystakecareduringinstallationand
performseveraltestcallsfromallextremesofthehome.
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk
PULLTHEWRIST
STRAPTOREMOVE
THE2BLACK
PLASTICINSERTS
FROMTHEFALL
DETECTORBODY.
FITTHEBELTCLIP
PARTTOTHETOP
ANDTHEBLANKING
PARTTOTHE
BOTTOMAS
SHOWNHERE.

DocNo.FM0795issueBPage2
tynetec
SwitchingtheFallDetectorON
Thefalldetectorisswitchedofftoconservebatterylifeintransit,toturnthefalldetectoron…
ProgrammingMode
Thereare4programmingoptionsavailable;
1=SensitivitySetting thissetsthelevelofimpactrequiredtoactivateafallalarm
2=VibrationAlerton/off thisprovidestheuserawarning10secondsbeforeafallalarmwillbetransmitted
3=Auto‐Cancelon/off thisdetermineswhetherafallalarmcanbecancelledbytheuser
4=TransportMode thisturnsthefalldetectorofftoconservebatterylifewhennotinuse
ToenterProgrammingMode;
PressandholdthesmallBLACKbuttonuntiltheunit((VIBRATES))thenrelease
ThelightwillflashthroughAMBERGREENREDforseveralsecondswhilea“FALL”alarmisbeingtransmitted
Whenthelightstopsflashingtheunitwill((VIBRATE))againtoindicateitisinProgrammingMode.
ToselecttheMenuOption;
PressthesmallBLACKbuttontostepthroughthe4menuoptions
ThelightwillflashREDand1to4vibrationswillbefeltaseachmenuoptionisreached
PressthelargeSILVERbuttontoselectthechosenoption,theunitwill((VIBRATE))toconfirmselection.
Note:ifnobuttonsarepressedfor10secondsthelightwillflashgreenandunitwillexitprogrammingmode.
Option1:SensitivitySetting
Whenmenuoption1isselectedthelightwillflashGREENanumberoftimestoindicatethecurrentsensitivitysetting
PressthesmallBLACKbuttontostepthroughtheSensitivitySettinglevels
TheunitwillvibrateandflashitslightRED1,2,or3timestoindicatethenewsensitivitylevel
1=High,2=Medium(default)and3=Low
OncethedesiredlevelisreachedpressthelargeSILVERbuttontoconfirm
Theunitwill((VIBRATE))thenflashGREENAMBERREDtoconfirmitssettings(seepage3)beforeexitingprogrammingmode.
Option2:VibrationAlertOn/Off
PlacetheunitintoProgrammingModeandselectmenuoption2
Whenoption2isselectedthelightwillflashAMBERanumberoftimestoindicatethecurrentvibrationalertsetting
PressthesmallBLACKbuttontotoggleVibrationAlertON/OFF
1vibration&1REDflash=VibrationAlertON
2vibrations&2REDflashes=VibrationAlertOFF(default)
OncethedesiredsettingismadepressthelargeSILVERbuttontoconfirm
Theunitwill((VIBRATE))thenflashGREENAMBERREDtoconfirmitssettings(seepage3)beforeexitingprogrammingmode.
Option3:Auto‐CancelOn/Off
Placetheunitintoprogrammingmodeandselectmenuoption3
Whenoption3isselectedthelightwillflashREDanumberoftimestoindicatethecurrentauto‐cancelsetting
PressthesmallBLACKbuttontotoggleAuto‐CancelON/OFF
1vibration&1REDflash=Auto‐CancelOFFi.e.analarmcannotbecancelledregardlessofactionbytheuser(default)
2vibrations&2REDflashes=Auto‐CancelON;analarmcallcanbecancelledbymovement(i.e.shakingthewrist)beforeand
afterthe5secondvibrationperiod
OncethedesiredsettingisselectedpressthelargeSILVERbuttontoconfirm
Theunitwill((VIBRATE))thenflashGREENAMBERREDtoconfirmitssettings(seepage3)beforeexitingprogrammingmode.
Option4:SwitchingtheFallDetectorOFF(TransportMode)
Placetheunitintoprogrammingmodeandselectmenuoption4
Whenoption4isselectedthelightwillflashREDtwicetoindicateTransportMode
PressthelargeSILVERbuttontoconfirmandthelightwillflashREDthreetimes
Theunitwill((VIBRATE))thenflashGREENAMBERREDtoconfirmitssettings(seepage3)beforeswitchingoff.
PressandholdthelargeSILVERbuttonfor3secondsthenrelease,thelight
willflashREDforseveralsecondstoindicatetheunitisswitchedon.

DocNo.FM0795issueBPage3
tynetec tynetec tynetec
tynetec
ConfirmationofSettings
WhenevertheunitexitsprogrammingorregistrationmodeitwillvibrateandflashitslightGREENAMBERREDanumberoftimes
toindicateitsSensitivitySetting,ifVibrationAlertisonoroffandifAuto‐Cancelisonoroff.AftertheREDflashsequencethefall
detectorwillreturntonormaloperatingmode.
RegisteringaFallDetectorontoaReachat‐homealarmunit
1.PuttheReachunitintoradiodevicelearnmode…
2.Activatethefalldetector…
3.Exitradiodevicelearnmode…
4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall,activatethefalldetectorbothwaysandconfirmthey
receivebothpendantandfallalarmcalls.
DeletingaFallDetectorfromaReachat‐homealarmunit
Enter1670usingthekeypadontherearoftheReachunit–thefrontlightwillFLASHFASTGREENandtheunitwillannounce
“ProgramMode‐Ready”.
Enter#041andtheReachwillannounce“DeleteRadioDevice”followedbya“Beep”.
Enterthe8digitfalldetectorID(22xxxxxx)tobedeletedandtheunitwill“Beep”.
Enterthe8digitpendantID(20xxxxxx)tobedeleted,afterthe“Beep”press#toexit.
PressthekeytoexitProgramMode;theunitwillsounda“Double‐Beep”andthefrontlightwillreturntoSTEADYGREEN.
TheseinstructionsapplytothestandardReach,ReachPlus,ReachPlusGSMandReachUltramodels.
Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation.
followedby…
GREENFLASHESindicatethe
Sensitivitysetting;
1=High(mostsensitive)
2=Medium(default)
3=Low(leastsensitive)
followedby…
AMBERFLASHESindicatethe
VibrationAlertsetting;
1=VibrationAlertON
2=VibrationAlertOFF(default)
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounce“TriggerRadioDevice”.
Younowhave1minutetoactivatethefalldetector.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
unitisnowbackinnormaloperatingmode.
“Trigger
Radio
Device”
REDFLASHESindicatethe
Auto‐Cancelsetting;
1=Auto‐CancelOFF(default)
2=Auto‐CancelON
PressandHOLDthelargeSILVERbuttonfor3secondsthenrelease,thelightwill
flashREDforseveralsecondsandtheReachunitwillannounce“Pendant”.
After5seconds,thelightwillstartflashingREDagainandtheReachunitwill
announce“Fall”.

DocNo.FM0795issueBPage4
tynetec
tynetec
tynetec
RegisteringaFallDetectorontoanAdventxtwardencallsystem
1.PuttheAdventxtsystemintoradiodevicelearnmode…
2.FirstactivateaPENDANTalarmonthefalldetector…
3.ThenactivateaFALLalarmonthefalldetector…
4.Exittheregistrationmode…
5.Activatethefalldetectorandcheckbothpendantandfallalarmcallsarereportedonthewardencallsystem.
DeletingaFallDetectorfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitforthe“Ready”prompt,enter5001followedbythekey.
Waitforthe“RadioDeviceDisable–EnterFlat”prompt.
Entertheflatnumberthefalldetectorisbeingdeletedfromfollowedbythekey.
Usingthefalldetectortobedeleted,pressthelargeSILVERbuttononthefalldetectortobedeleted.
Waitforthe“PendantRadioDeviceDisabled–EnterFlat”prompt.
Enterthesameflatnumberthefalldetectorisbeingdeletedfromagainfollowedbythekey.
ThistimepressandholdthesmallBLACKbuttonuntiltheunitvibratesthenrelease.
Waitforthe“FallRadioDeviceDisabled–EnterFlat”prompt.
Pressthe#keyandwaitforthe“Ready”prompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogrammingandtestingradiodevices.
UsingtheManager’sDECTphone;
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5000followedbythekey.
Entertheflatnumberthefalldetectorisbeinginstalledinfollowedbythekey.
Waitforthe“Flat“x”–EnableRadioDevice”prompt
Younowhave1minutetoactivatethefalldetector.
“Ready”
“Ready”
PressandholdthesmallBLACKbuttonforabout3secondsuntilthefalldetector
vibratesthenrelease;thelightwillflashAMBERGREENREDforseveralseconds.
Waitforthe“FallRadioDevice–EnterLocationCode”promptthenpress0(no
location)followedbythekey.
Waitforthe“LocationCode0–RadioDeviceEnabled–EnterFlat”prompt.
PresstheSILVERbuttononce,thelightwillflashREDforseveralseconds.
Waitforthe“PendantRadioDevice–EnterLocationCode”promptthenpress0
(nolocation)followedbythekey.
Waitforthe“LocationCode0–RadioDeviceEnabled–EnterFlat”prompt.
Enterthesameflatnumberagainfollowedbythekey.
PresstheSILVERbuttontoexitthefall
detectorregistrationmode,orafter
about10secondsitwillexititself.
Onexititwillvibrateandflashasequence
ofcolourstoconfirmitssettings(seepage3).
UsingtheManager’sDECTphonepressthe#key
andwaitforthe“Ready”prompt.
PresstheLINEkeytocleartheconnectionand
thewardencallsystemisnowbackinnormal
operatingmode.

DocNo.FM0795issueBPage5
tynetec
tynetec
tynetec
RegisteringaFallDetectorontoanAltecResponselocalcareralarmunit
1.PuttheAltecResponseunitintoradiodevicelearnmode…
2.ActivateaPENDANTalarmonthefalldetector…
3.ActivateaFALLalarmonthefalldetector…
4.Exitthefalldetectorregistrationmode…
5.ExittheAltecResponseradiodevicelearnmode…
6.ActivatethefalldetectorandcheckbothpendantandfallalarmcallsaredisplayedontheAltecResponseunit.
PressandholdthesmallBLACKbuttonforabout3secondsuntilthefalldetector
vibratesthenrelease;thelightwillflashAMBERGREENREDforseveralseconds.
Whenthetransmissioniscompletethefalldetectorwillvibrateagain.
ThedisplaywillshowFallDetectorandthefalldetector8digitIDnumber.
IftheIDiscorrectpressthekeytoselectAcceptthenpressENTER.
Re‐enterthesamedetailsasaboveforthefalldetector.
PressthelargeSILVERbuttononce,thelightwillflashREDforseveralseconds.
ThedisplaywillshowPersonalPendantandthefalldetector8digitIDnumber.
ChecktheIDiscorrect,pressthekeytoselectAcceptthenpressENTER.
Note:ifanotherdevicehasbeenpicked‐uppressENTERtoRejectandtryagain.
ThedisplaywillshowFlat,usethe&keystochoosethedwellingtype.
PressthekeytoselectNo:000000thenpresstheENTERkey.
Usethe&keystoselecteachdigitoftheflatnumberandthe&keysto
movebetweendigitsthenpresstheENTERkey.
PresskeyseveraltimestoselectExitthenpresstheENTERkey.
Thedisplaywillpromptyouto“TriggertheSensor”again.
PressthelargeSILVERbuttononce,thefalldetectorwillvibrateandthelight
willflashasequenceofcolourstoconfirmitssettings(seepage3).
or…afterabout10secondsthefalldetectorwillexitregistrationmode
automaticallyandconfirmitssettings.
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplay
themainmenu.
PressENTERtoselectRadioDevices
PressENTERtoselectLearnDevice
Thedisplaywillpromptyouto“TriggertheSensor”.
Younowhave20secondstoactivatethefalldetector.
FromtheLearnDevicemenuselectExitthenpressENTER.
FromtheRadioDevicesmenuselectExitthenpressENTER.
Thedisplaywillreturntothewake‐upscreenandgoblankafter10seconds.
TheAltecResponseisnowinnormaloperatingmode.
tynetec
tynetec

DocNo.FM0795issueBPage6
DeletingaFallDetectorfromanAltecResponselocalcareralarmunit
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplaythemainmenu
PressENTERtoselectRadioDevices
PressthekeytoselectDeleteDevicethenpressENTER
Thedisplaywillpromptyouto“TriggertheSensor”
Usingthefalldetectortobedeleted,pressandholdthesmallBLACKbuttonuntiltheunitvibratesthenrelease‐thedisplaywill
showthedevicetypeandits8digitIDnumber
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Ifit’sNOTthedeviceyouactivatedpresstheENTERkeytoselectRejectthentryagain
PressthelargeSILVERbuttononthefalldetectortobedeleted‐thedisplaywillshowthedevicetypeandits8digitIDnumber
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Ifit’sNOTthedeviceyouactivatedpresstheENTERkeytoselectRejectthentryagain
ToexitthemodeselectExitthenpresstheENTERkey.
RefertotheAltecResponseinstallationguide(DocNo.FM0548)providedwiththeportablealarmunitfor
moreinformationonprogrammingandtestingradiodevices.
RegisteringaFallDetectorontoaTouchsafeProNursecallsystem
1.PuttheTouchsafeProMasterPanelintoTelecareregistrationmode;touchthescreenandLogonasanEngineeroraManager
(passwordrequired),thenfromthemainmenupagetouchtheTelecarebuttontoopenthescreenshownbelow…
2.EnterthefalldetectorID…
3.PresstheClosebuttontoexitTelecaremodeandtheNursecallpanelisnowinnormaloperatingmode.
The8digitIDisprintedonthesilverlabelontherearofthefalldetector.
Note:thisIDwillalwaysstartwith22xxxxxx(22prefix=fall).
TouchtheAddTelecareDeviceboxthenusetheon‐screenkeypadtoentertheID.
Hint:enterazoneintheFilterboxtonarrowthesearchfortheroom.
SelecttheusersCallPointIDfromtheRoompull‐downboxthenpressSave.
Note:thisistheroomunitthatwillbewillbeusedtocancelthecall.
Usetheon‐screenkeypadtoenterthesame8digitIDagainbutthistimechange
thefirst2digitsfrom“22”to“20”(20prefix=pendantcall).
SelectthesameZoneandCallPointIDasabovethenpressSave.
ID:22408597
Ser:251718194
ZXT413
Iss:1
Freq169MHz
EnvGroupII
*Note:falldetectorID
mustbeenteredtwice;
Prefix22=falland
Prefix20=pendant
Usekeypadtoenter
8digitID*here
Selecttherelevant
CallPointIDhere
Savewhendone
Closetoexitmode
On‐screenkeypad

DocNo.FM0795issueBPage7
4.PresstheSILVERbuttononthefalldetectorandcheckthecallisdisplayedontheNursecallpanellikethis…
Thescreenbannerisorangeforapendantcall(Touchthebannertodisplaynotes).
PresstheAcceptbuttononthebannertosilencethealarm‐thiswillalso
notifyallotherpanelsthecallisbeingdealtwith.
Thescreenbannerchangestopurplewhenacallisaccepted.
YoumustvisittheappropriateNursecallCallPointtocancelthecall.
5.PressandholdthesmallBLACKbuttonforabout3secondsuntilthefalldetector
vibratesthenrelease,checkthealarmisdisplayedontheNursecallpanellikethis…
Thescreenbannerisredforafallalarm(Touchthebannertodisplaynotes).
Afallalarmcannotbeacceptedorsilencedfromthescreen.
YoumustvisittheappropriateNursecallCallPointtocancelthecall.
DeletingaFallDetectorfromaTouchsafeProNursecallsystem
SelectthefallDetectorIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixedwitha“T22”).
DetailsofthefalldetectorselectedwillbedisplayedintheRoom,HouseCodeandIDboxesbelow.
IfthedetailsshownarecorrectpresstheDeletebutton.
SelectthependantIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixedwitha“T20”).
DetailsofthependantselectedwillbedisplayedintheRoom,HouseCodeandIDboxesbelow.
IfthedetailsshownarecorrectpresstheDeletebutton.
PresstheClosebuttontoexit.
RefertotheTouchsafeProDisplayPaneluserguide(DocNo.FM5505)providedwiththeNursecallsystemfor
moreinformation.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
Ifanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactourcustomersupportdepartmenton01670352371.
CALLING
CANCEL
HC345ID001
PresstheLIGHTGREY
buttontocancelthecall
Table of contents
Other Tynetec Security Sensor manuals
Popular Security Sensor manuals by other brands

Philips
Philips EasyAir SNS300 Quick installation guide

General Monitors
General Monitors TL104 instruction manual

olympia electronics
olympia electronics BS- 660/A quick start guide

Stanley
Stanley S100 user manual

IPVideo Corporation
IPVideo Corporation ViewScan Pro quick start guide

Orbis