Tynetec ZXT427 User manual

DocNo.FM0471issueFPage1
TRANSMIT
GAS
TRANSMIT
CO
169MHzTelecareDevices
Gas&CarbonMonoxideDetector
__________________________________________________________________________________________________________
CompatiblewithReachat‐homealarms,Adventxtwardencall,
AltecResponseandTouchsafeProNursecallsystems
Gasalarmactivatesat10%ofLowerExplosiveLimit
COalarmactivatesonTimeWeightedAverage;
30ppm2hrs,50ppm1hr,100ppm10minsor300ppm0‐3mins
85dB@3msounder
Indicatorlights:greenpower,yellowfault&redalarm
Requires240VACmainssupply(5mlead&plugsupplied)
Transmitterlowbatterywarning
ComplieswithEN50194(Gas)&EN50291(CO)
Backplatedimensions:175x140mm(depth=55mm)
Weight:640grams
ProductCode:ZXT427
WhereshouldGas&CarbonMonoxideDetectorsbefitted?
CombinedGas&CarbonMonoxide(CO)detectorsshouldbefittedinallroomswithafuelburningappliancesuchasaboileror
gascookerandwherealotoftimeisspente.g.thekitchenorlivingroom.
Theyshouldnotbefittedinthebathroomorareassubjecttosteam,damporhumidity.
ChoosingaLocation
Thecombinedgas&COdetectorshouldbewallmountedinthehighestpartoftheroom,approx300mmfromtheceilingand
between1and5metresfromtheappliance.
Thecombinedgas&COdetectorshouldnotbelocatedinsideacupboard,behindacurtain,directlyabovethecookerorsink,next
toadoororwindowornearanextractorfan.
Thecombinedgas&COdetectorshouldbewithin5metresofamainssocketotherwisethecableprovidedwillneedextending.
TypicalToolsRequired
Becarefulwhenusingstepladders–alwaysfacethedirectionyouareworking.
Alwaysmakesurethecorrectdrillbitsandscrewdriversareused.
Installation
1. Fixthemountingplatecompletewithdetectortothewallusing
thescrewsandplugsprovidedthroughFIXINGHOLES“A”.
2. Runthemainsleadtothenearestsocketandsecureusing
theselfadhesivecableclipsprovided.
3. Plug‐inandswitchonthemainssupply–theGREENONlight
willFLASHforabout2minutesduringthesensorwarm‐upperiod.
4. WhentheGREENONlightgoessteadytheunitisoperatingnormally.
4FIXINGHOLES“A”
A
AA
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk

DocNo.FM0471issueFPage2
Testing&RegisteringtheGas&CODetector
TheTRANSMITGASandTRANSMITCOpushbuttonsonthelid
areusedwhenregisteringthecombinedGas&COdetector
ontothewardencallsystem,at‐homealarmorNursecallsystem.
Seethefollowingpagesforhowtoputeachoftheseproductsintoregistrationmode.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment,
alwaystakecareduringinstallationandperformseveraltestcalls.
ImportantNoteonSensorTesting
ThegasandCOdetectorshouldbefunctionallytestedevery6‐12months(dependingonlocation).
Thegassensorcanonlybetestedwithcalibratedtestgas,nevertestusingneatgasasthiswillpoisonthesensor.
TheCOsensorcanonlybetestedwithcalibratedtestCO,thiswilltakelessthan1minutetotrigger.
FortestgassuppliespleasecontactDuomo.
InCaseofGasAlarm
IfgasisdetectedtheRED“ALARMGAS”lightwillilluminateandtheaudiblealarmwillsound.
Putoutallnakedflames.
Don’tsmoke.Don’tusenakedflames.
Don’tturnelectricalswitchesonoroff.
Turnthegasoffatthesupply.
Openwindowsanddoorstoventilatethearea.
Thealarmwillsilencewhenthegasiscleared.Ifthealarmcontinuestosoundandtheleakcannotbefound,vacatethepremises
andinformtheGasEmergencyServiceimmediately.
InCaseofCarbonMonoxideAlarm
IfcarbonmonoxideisdetectedtheRED“ALARMCO”lightwillilluminateandtheaudiblealarmwillsound.
Openwindowsanddoorstoventilatethearea.
Ifthealarmstopsitissafeforaqualifiedpersontofindthecauseofthealarm.
Ifthealarmcontinuesturntheapplianceoffanddonotuseuntilithasbeencheckedbyaqualifiedperson.
Getmedicalhelpforanyonesufferingheadachesornausea,advisethatcarbonmonoxidepoisoningissuspected.
InCaseofFault
IftheYELLOW“FAULT”lightilluminatestheselftestfeaturehasdetectedafaultwiththesensor.
Theunitisprobablydefectiveandmustbereplaced.
After6yearstheYELLOWlightwillblinkcontinuouslyandtheunitwillemitabeepeveryhour.
Thesensorhasexceededitsusefullifeandmustbereplaced.
FalseAlarms
Itispossibleaerosolsprays,alcoholusedincooking,cigarette,cigaror
pipesmoke,gasfromacigarettelighter,stronghouseholdcleaning
agents,polishesorsolventsmaycausefalsealarms.
CleaningandCare
Itisrecommendedtocleanthegas&COdetectorperiodicallyusingthenozzleattachmentonavacuum
cleanertoremovedust,insectsandcobwebsfromthecoverslots.
Thedetectorcanbewipedcleanwithadampcloth,neverusedetergentsorpolishetc.
Avoidsprayinganyaerosolsnearthedetector.
Decorating
Neverpaintthegas&COdetectoritself.
Unplugthemainssupplyandcoverthedetectorwhendecoratingto
avoidcontaminationfromwaterordust.
BatteryLife
Thetransmitterbatteryischeckedonceaday,ifthevoltagefallsandstaysbelowapresetlevelfor7consecutivedaysalow
batteryalertisautomaticallytransmitted.Oncealowbatterycallisreceivedthegas&COdetectorshouldbereplacedwithin7
days.Thegas&COdetectormustbereturnedtoTynetec/Aidcallforbatteryreplacement.
DetailedinformationonbatterymanagementforallTynetec/Aidcallproductsisavailable‐requestDocNo.FM0630.
TRANSMIT
CO
TRANSMIT
GAS

DocNo.FM0471issueFPage3
TRANSMIT
GAS
TRANSMIT
CO
RegisteringaGas&CODetectorontoaReachat‐homealarmunit
1.PuttheReachunitintoradiodevicelearnmode…
2.Activatethegas&COdetector…
3.Exitradiodevicelearnmode…
4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall,firstactivateagastestcallandconfirmtheyreceivea
gasalarmcall,thenactivateaCOtestcallandconfirmtheyreceiveacarbonmonoxidealarmcall.
DeletingaGas&CODetectorfromaReachat‐homealarmunit
Enter1670usingthekeypadontherearoftheReachunit–thefrontlightwillFLASHFASTGREENandtheunitwillannounce
“ProgramMode‐Ready”.
Enter#041andtheReachwillannounce“DeleteRadioDevice”followedbya“Beep”.
Enterthe8digitgasdetectorIDtobedeletedandwaitforthe“Beep”
Enterthe8digitCOdetectorIDtobedeleted,afterthe“Beep”press#toexit.
PressthekeytoexitProgramMode;theunitwillsounda“Double‐Beep”andthefrontlightwillreturntoSTEADYGREEN.
Both8digitID’scanbefoundonalabelonthebackofthegas&COdetector–theywillalwaysstartwith44xxxxxxand49xxxxxx.
TheinstructionsgivenaboveforthestandardReachproductalsoappliestotheReachPlus,ReachPlusGSM
andReachUltramodels.Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation
onprogrammingandtestingradiodevices.
“Trigger
Radio
Device”
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounce“TriggerRadioDevice”.
Younowhave1minutetoactivatethegas&COdetector.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
PresstheTRANSMITGASbuttononceandtheReachwill
announce“Gas”.
Waitforabout10secondsthen…
PresstheTRANSMITCObuttononceandtheReachwill
announce“CarbonMonoxide”.

DocNo.FM0471issueFPage4
TRANSMIT
GAS
TRANSMIT
CO
RegisteringaGas&CODetectorontoanAdventxtwardencallsystem
1.PuttheAdventxtsystemintoradiodevicelearnmode…
2.Activatethegas&COdetector…
3.ExittheAdventxtsystemradiodevicelearnmode…
4.Firstactivateagastestcallandcheckagasalarmcallisreportedonthewardencallsystem,thenactivateaCOtestcalland
checkacarbonmonoxidealarmcallisreported.
DeletingaGas&CODetectorfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5001followedbythekey.
Entertheflatnumberthegasdetectorisbeingdeletedfromfollowedbythekey.
PresstheTRANSMITGASbuttononthegas&COdetectortobedeleted.
Waitforthe“PendantDisabled–EnterFlat”prompt.
PresstheTRANSMITCObuttononthegas&COdetectortobedeleted.
Waitforthe“PendantDisabled–EnterFlat”prompt.
Pressthe#keyandwaitforthe“Ready”prompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogrammingandtestingradiodevices.
UsingtheManager’sDECTtelephone;
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5000followedbythekey.
Entertheflatnumberthegas&COdetectorisbeinginstalledin
followedbythekey.
Younowhave1minutetoactivatethegas&COdetector.
“Ready”
UsingtheManager’sDECTtelephone;
Pressthe#keyandwaitforthe“Ready”prompt.
PresstheLINEkeytocleartheconnectionandthewardencallsystemis
nowbackinnormaloperatingmode.
PresstheTRANSMITGASbuttononce.
Waitforthe“EnterLocationCode”promptthenpress0
(nolocation)followedbythekey.
Waitforthe“PendantEnabled–EnterFlat”prompt.
PresstheTRANSMITCObuttononce.
Waitforthe“EnterLocationCode”promptthenpress0
(nolocation)followedbythekey.
Waitforthe“PendantEnabled–EnterFlat”prompt.
“Ready”

DocNo.FM0471issueFPage5
TRANSMIT
GAS
TRANSMIT
CO
RegisteringaGas&CODetectorontoanAltecResponselocalcareralarmunit
1.PuttheAltecResponseunitintoradiodevicelearnmode…
2.Activatethegas&COdetector…
3.ExittheAltecResponseradiodevicelearnmode…
4.ActivatethegasdetectorandcheckagasalarmcallisdisplayedontheAltecResponseunit.
DeletingaGas&CODetectorfromanAltecResponselocalcareralarmunit
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplaythemainmenu
PressENTERtoselectRadioDevices
PressthekeytoselectDeleteDevicethenpressENTER
Thedisplaywillpromptyouto“TriggertheSensor”
PresstheTRANSMITGASbuttononthegas&COdetectortobedeleted‐thedisplaywillshowthedevicetypeandits8digitID
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
PresstheTRANSMITCObuttononthegas&COdetectortobedeleted‐thedisplaywillshowthedevicetypeandits8digitID
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Note:iftheIDisNOTthedeviceyouactivatedpresstheENTERkeytoselectRejectthentryagain
ToexitthemodeselectExitthenpresstheENTERkey.
RefertotheAltecResponseinstallationguide(DocNo.FM0548)providedwiththeportablealarmunitfor
moreinformationonprogrammingandtestingradiodevices.
PresstheTRANSMITGASbuttononce.
ThedisplaywillshowGasAlarmandthegasdetector8digitIDnumber.
ChecktheIDiscorrect,pressthekeytoselectAcceptthen
pressENTER.Note:ifanotherdevicehasbeenpicked‐uppress
ENTERtoRejectandtryagain.
ThedisplaywillshowFlat,usethe&keystochoosethe
dwellingtype.
PressthekeytoselectNo:000000thenpresstheENTERkey.
Usethe&keystoselecteachdigitoftheflatnumberandthe
&keystomovebetweendigitsthenpresstheENTERkey.
PresskeyseveraltimestoselectExitthenpresstheENTERkey.
Thedisplaywillpromptyouto“TriggertheSensor”again.
PresstheTRANSMITCObuttonandrepeatasabove.
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplay
themainmenu.
PressENTERtoselectRadioDevices
PressENTERtoselectLearnDevice
Thedisplaywillpromptyouto“TriggertheSensor”.
Younowhave20secondstoactivatethegas&COdetector.
FromtheLearnDevicemenuselectExitthenpressENTER.
FromtheRadioDevicesmenuselectExitthenpressENTER.
Thedisplaywillreturntothewake‐upscreenandgoblankafter10seconds.
TheAltecResponseisnowbackinnormaloperatingmode.
tynetec
tynetec

DocNo.FM0471issueFPage6
RegisteringaGas&CODetectorontoaTouchsafeProNursecallsystem
1.PuttheTouchsafeProMasterPanelintoTelecareregistrationmode;touchthescreenandLogonasanEngineeroraManager
(passwordrequired),thenfromthemainmenupagetouchtheTelecarebuttontoopenthescreenshownbelow…
2.EnterthegasandCOdetectorID’s…
3.PresstheClosebuttontoexitTelecaremodeandtheNursecallpanelisnowbackinnormaloperatingmode.
4.ActivatebothgasandCOtestcallsandchecktheyaredisplayedontheNursecallpanellikethis…
ThescreenbannerisredforagasandCOalarmcall(Touchthebannertodisplaynotes).
AgasorCOalarmcallcannotbeacceptedorsilencedfromthescreen.
YoumustvisittheappropriateNursecallCallPointtocancelthecall.
DeletingaGas&CODetectorfromaTouchsafeProNursecallsystem
SelectthegasdetectorIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixed“T44”).
DetailsofthegasdetectorselectedwillbedisplayedintheRoom,HouseCodeandIDboxesbelow.
IfthedetailsshownarecorrectpresstheDeletebutton.
SelecttheCOdetectorIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixed“T49”)andrepeatasabove.
PresstheClosebuttontoexit.
RefertotheTouchsafeProDisplayPaneluserguide(DocNo.FM5505)providedwiththeNursecallsystemfor
moreinformation.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
Both8digitID’sareprintedonalabelontherearofthegas&COdetector.
Note:theID’swillalwaysstartwith44xxxxxx(gas)and49xxxxxx(CO).
TouchtheAddTelecareDeviceboxthenusetheon‐screenkeypadtoenterthegasID.
Hint:enterazoneintheFilterboxtonarrowthesearchfortheroom(seebelow).
SelecttheusersCallPointIDfromtheRoompull‐downlistboxthenpressSave.
Note:thisistheroomunitthatwillbewillbeusedtocancelthecall.
TouchtheAddTelecareDeviceboxagainandrepeatasabovefortheCOID.
Usekeypadtoenter
8digitID’s*here
Selecttherelevant
CallPointIDhere
Savewhendone
Closetoexitmode
On‐screenkeypad
CALLING
CANCEL
HC345ID001
PresstheLIGHTGREY
buttontocancelthecall
ZXT427W66283
Ser:10151313
ID:44037640
ID:49040302
EE0775V1.01A
MC
*Note:bothgasandCO
ID’smustbeentered;
Prefix44=Gas
andPrefix49=CO
Table of contents
Other Tynetec Security Sensor manuals
Popular Security Sensor manuals by other brands

Cura1
Cura1 iBeam 2721 quick start guide

Ecolink
Ecolink Firefighter CS-600 Installation manual & users guide

EOT
EOT ET-3500AF user guide

Intermatic
Intermatic IOS-CMP-DT-U Installation and configuration instructions

Mitsubishi Electric
Mitsubishi Electric PZ-70CSD-E Installation and instruction manual