DocNo.FM0599issueDPage1
169MHzTelecareDevices
PIRMovementDetector
__________________________________________________________________________________________________________
CompatiblewithReachat‐homealarmsand
Adventxtwardencallsystems
Passiveinfrareddetector
WalktestLED(disabledduringnormaloperation)
Alarminterval:1or3minutes
UserreplaceableAALithiumbatteries
Lowbatterywarning
Dimensions:121mmx71mmx55mm(HxWxD)
Weight:135grams
ProductCode:ZXT475
WhatcanthePIRMovementDetectorbeusedfor?
ThePIRdetectorcanbeusedfor2differentapplications;
IntruderMonitoring–ifmovementisdetectedanalarmisreported
InactivityMonitoring–ifnomovementisdetectedwithinapresetperiodanalarmisreported
RecommendedLocation
ThePIRshouldbewallmountedathighlevel(2.1m)inthehallwaytomonitormovementbetweenrooms.
IftherearepetsinthehomethePIRshouldbeinvertedandfittedatlowlevel(1m)–seePETALLEYmode.
ConditionstoAvoid
AvoidplacingitemsinfrontofthePIRdetectorwhichmayrestrictitsfieldofview
DonotexposethePIRdetectortodirectsunlightorpowerfullights
DonotexposethePIRdetectortorapidvariationintemperature
DonotexposethePIRdetectortowind,airconditioningorheating
DonotdropthePIRdetectororexposetohighvibrationorshock
TypicalToolsRequired
Becarefulwhenusingstepladders–alwaysfacethedirectionyouareworking.
Adrillisnotrequirediftheselfadhesivefixingpadisused.
Alwaysmakesurethecorrectdrillbitsandscrewdriversareused.
Installation–UsingScrewFixings
1. UndoSCREW“A”fromthebottomofthedetectorandremovethe
completelidassembly.
2. Drill‐outthe2mostsuitableFIXINGHOLES“B”insidetherearsection.
Usethisasatemplatetomarkthewall.
3. Beforedrillingthewallbesuretherearenoelectricalcables
orplumbingunderthesurface.
4. Usethescrews&plugsprovidedtofixtherearsectiontothewall
notingthecorrectorientation(seenextpageforPETALLEY).
5. Removetheinsulatingtabtoconnectthebatteries,
refitthelidandtightenthescrew.
Installation–UsingSelfAdhesivePads
UndoSCREW“A”andremovethelidassembly.
Removetheinsulatingtabtoconnectthebatteries.
Refitthelidandtightenthescrew.
Selectthebestlocationwherethewallsurfaceisclean,dryandeven.
Sticktheadhesivepadtotherearofthedetector.
Pressthedetectorfirmlyagainstthewallensuringitisstucksecurely.
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk
NORMAL
ORIENTATION
UP
SCREW“A”
FIXINGHOLES“B”

DocNo.FM0599issueDPage2
PetAlleyModeUP
TopreventpetscausingfalseactivationsthePIRdetector
mustbeinvertedandfittedatlowlevel(1m). PETALLEYORIENTATION
Whenfittedinthismodeanymovementbelow FITATLOWLEVELWITHLEDATTHETOP
the1mlevelwillgoun‐detected.
Resultsbasedontestsina4mx4mroom.
WalkTestMode
Toenterthewalktestmode;
1. UndothescrewandremovethePIRlid
2. Waitforabout5seconds
3. Refitthelid
4. ThefrontredLEDwillflashrapidly8times
Younowhave3minutestoperformawalktest.
TheredLEDwillflashoncewhenmovementisdetected.
NOTE:therearenoradiotransmissionsduringawalktest.
AttheendofthewalktestperiodtheredLEDwill
flashrapidly8times.
ThePIRisnowinnormaloperatingmodeand
theLEDwillNOTflashwhenmovementisdetected.
Testing&RegisteringthePIRDetector
WhenthePIRlidisremovedthetamperswitchwilloperateandtransmitanalarmsignal.Thiswillalsocheckthebatterycondition
(andreportanalarmiflow)toassistServiceEngineers.
ThetamperswitchshouldbeactivatedwhenlearningthePIRontotheReachat‐homealarmorAdventxtwardencallsystem.
Seepages3&4forhowtoputeachoftheseproductsinto“LearnMode”.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment‐alwaystakecareduringinstallationand
performseveraltestcalls.
DILSwitchSettings
The2wayDILswitchinsidethePIRdetectorisusedtosetthesensitivityandalarminterval;
DILSwitchNo.&FunctionOFF(Default)ON
SW1=PulseCount(Sensitivity)2pulsestotrigger3pulsestotrigger
SW2=AlarmIntervalTime3minutes1minute
IffalsealarmsareaproblemtrysettingDILswitch1ONtoreducethesensitivity.
AfteranactivationthePIRturnsitselfoffforthealarmintervaltimetoconservebatterypower.
Duringthealarmintervalperiodmovementisnotdetected.
Maintenance
Noroutinemaintenanceisrequired;howeverawalktestshouldbeperformedonceayeartoverifyoperation.
PIR’sarenotassusceptibletodustandcontaminationassomedetectorsbutitisstillrecommendedtocleanthemperiodically.
PIR’scanbedustedorwipedcleanwithadampcloth,neverusedetergentsorpolish.
Decorating
NeverpaintthePIRdetectoritself.
Unlikesomedetectors,PIR’sarenotsusceptibletocontamination
frompaintfumesthereforenospecialprecautionsneedtobetaken.
BatteryLife
ThePIRcontains2longlifeLithiumbatteries.Undernormaloperatingconditions
(40activations/day)thebatteriesshouldlastforupto2years.
Thebatteryconditionischeckedonceaday,ifthevoltagefallsandstaysbelowa
presetlevelfor7consecutivedaysalowbatteryalertisautomaticallytransmitted.
Anotherlowbatterycallwillnotbetransmittedfor7days,thebatteriesshould
bereplacedwithin2weeksofthefirstlowbatterywarning.
Replacementbatteries:2xAAsizeEnergizerLithium–alwaysreplaceinpairs.
Takecaretorefitthebatteriesinthecorrectpolarity.
NORMALDETECTION
PATTERN‐SIDEVIEW
PETALLEYDETECTION
PATTERN‐SIDEVIEW
DETECTIONPATTERN
TOPVIEW

DocNo.FM0599issueDPage3
RegisteringaPIRDetectorontoaReachat‐homealarmunit
1.PuttheReachunitintoradiodevicelearnmode…
2.ActivatethePIRdetectortamper…
3.Exitradiodevicelearnmode…
4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall.PresstheGREENbuttonontheReachunitanditwill
announce“IntruderMode…Ready”.Pressthependantwithin20secondsandtheReachwillannounce“Enabled”followedby
“Beep‐Beep”forthedurationoftheexittime.Lettheexittimeexpirethenopenthedoor,donotdisableintrudermodeonthe
Reachunit,whentheentrytimeexpiresanintruderalarmcallwillbereportedtotheControlCentre.
DeletingaPIRDetectorfromaReachat‐homealarmunit
Enter1670usingthekeypadontherearoftheReachunit–thefrontlightwillFLASHFASTGREENandtheunitwillannounce
“ProgramMode‐Ready”.
Enter#041andtheReachwillannounce“DeleteRadioDevice”followedbya“Beep”.
Enterthe8digitPIRIDtobedeleted;afterthe“Beep”press#toexit.
PressthekeytoexitProgramMode;theunitwillsounda“Double‐Beep”andthefrontlightwillreturntoSTEADYGREEN.
The8digitIDcanbefoundonalabelinsidethebackofthePIRdetector–itwillalwaysstartwith50xxxxxx
TheinstructionsgivenaboveforthestandardReachproductalsoappliestotheReachPlus,ReachPlusGSM
andReachUltramodels.Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation
onprogramming/testingradiodevicesandsetup/operatingintrudermode.
“Trigger
Radio
Device”
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounce“TriggerRadioDevice”.
Younowhave1minutetoactivatethePIRdetector.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
UndothescrewandremovethePIRlidfromitsbasetoactivatethe
tamperswitch.
TheReachwillannounce“MovementSensor”.
RefitthePIRlid.

DocNo.FM0599issueDPage4
RegisteringaPIRDetectorontoanAdventxtwardencallsystem
1.PuttheAdventxtsystemintoradiodevicelearnmode…
2.ActivatethePIRdetectortamper…
3.ExittheAdventxtsystemradiodevicelearnmode…
4.UsingtheManager’sDECTtelephonesettheflatintointrudermode;presstheLINEkeyandwaitforthe“Ready”prompt,enter
3007thenentertheflatnumbertohaveintrudermodeenabledfollowedbythekey,thenpresstheLINEkeytoclearthe
connection.Openthedoorandcheckanintruderalarmcallisreportedonthewardencallsystem.Toresetintrudermode;enter
3008thenentertheflatnumbertobedisabledfollowedbythekey,thenpresstheLINEkeytocleartheconnection.
DeletingaPIRDetectorfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5001followedbythekey.
EntertheflatnumberthePIRisbeingdeletedfromfollowedbythekey.
ActivatethetamperswitchonthePIRtobedeleted.
Waitforthe“PendantDisabled–EnterFlat”prompt.
Pressthe#keyandwaitforthe“Ready”prompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogramming/testingradiodevicesandoperationoftheintrudermode.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
UsingtheManager’sDECTtelephone;
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5000followedbythekey.
EntertheflatnumberthePIRisbeinginstalledinfollowedbythekey.
Younowhave1minutetoactivatethePIRdetector.
“Ready”
UsingtheManager’sDECTtelephone;
Pressthe#keyandwaitforthe“Ready”prompt.
PresstheLINEkeytocleartheconnectionandthewardencallsystemis
nowbackinnormaloperatingmode.
UndothescrewandremovethePIRlidfromitsbasetoactivatethe
tamperswitch.
Waitforthe“EnterLocationCode”promptthenpress0(nolocation)
followedbythekey.
Waitforthe“PendantEnabled–EnterFlat”prompt.
RefitthePIRlid.
“Ready”
Table of contents
Other Tynetec Security Sensor manuals
Popular Security Sensor manuals by other brands

B.E.G.
B.E.G. LUXOMAT Indoor 180-M-2C Installation and operating instruction

iSysmart
iSysmart SGZB11C user manual

Interlogix
Interlogix Firefighter SLX-AD-T3 Installation manual and user's guide

Micropack
Micropack FDS303 Safety & technical manual

Clare Controls
Clare Controls ClareOne CLR-C1-PIR Installation sheet

yellow jacket
yellow jacket 69373 Series Installation and operation manual