UCS C-SV 4A User manual

ULTRAFLEX CONTROL SYSTEMS s.r.l.
Via XXV Aprile 45
16012 BUSALLA (GE)
ITALY
Tel. +39 010 9768232
Fax +39 010 9768233
Doc. 85588U - Rev. 22/10/2020 Drw. / Dis. 32367/h
MANUALE D’USOMANUALE D’USO
USER MANUALUSER MANUAL
ITIT
ENEN
286 8005373
EN 12101-10:2005 + AC:2007


Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h3/54
1. GENERAL SAFETY RULES......................................................................................................................................................4
1.1 Symbols used......................................................................................................................................................................4
1.2Informaveleer ...............................................................................................................................................................5
2. PACKING CONTENTS.............................................................................................................................................................6
3. UNPACKING ..............................................................................................................................................................................6
4. DATA PLATE...............................................................................................................................................................................6
5. PRODUCT DESCRIPTION ......................................................................................................................................................7
6. TECHNICAL DATA.................................................................................................................................................................10
6.1 Dimensions.......................................................................................................................................................................10
7. INSTALLATION.........................................................................................................................................................................11
7.1 Controlpanelposioning .................................................................................................................................................11
7.2 Electricalconnecons.......................................................................................................................................................13
7.3 Calibraon ........................................................................................................................................................................14
8. USE .........................................................................................................................................................................................15
8.1 Commandsandsignals.....................................................................................................................................................15
8.2 Inialconguraon ..........................................................................................................................................................17
8.3 Commandsforsmokeextracon......................................................................................................................................18
8.3.1 Emergency ..............................................................................................................................................................18
8.3.2 EM SIG.....................................................................................................................................................................18
8.3.3 EM CL SIG ................................................................................................................................................................18
8.3.4 AUX SIG ...................................................................................................................................................................18
8.3.5Emergencyinterlock system ...................................................................................................................................19
8.3.6 Reset .......................................................................................................................................................................19
8.3.7 Emergencyclosing ..................................................................................................................................................19
8.4 Commandsfornaturalvenlaon....................................................................................................................................19
8.4.1 Manual naturalvenlaoncommands ...................................................................................................................19
8.4.2 Thermostat..............................................................................................................................................................20
8.4.3 CO2 sensor..............................................................................................................................................................20
8.4.4 Wind sensor ............................................................................................................................................................21
8.4.5 Rain sensor..............................................................................................................................................................21
9. MAINTENANCE.......................................................................................................................................................................22
9.1 Rounechecks..................................................................................................................................................................22
9.2 Baeries ...........................................................................................................................................................................22
10. ANOMALIES AND FAULTS .......................................................................................................................................................23
11. CLEANING...............................................................................................................................................................................23
12. DISPOSAL................................................................................................................................................................................23
13. WARRANTY.............................................................................................................................................................................24
INDEXINDEX

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h4/54
1. GENERAL SAFETY RULES
• Aertakingothepackagingmakesurethatthecontrolunitisintact.Incaseofdoubtdonotuseitandcontactanauthorized
service centre.
• Checkthatthecontrolunitisnotdamagedinanyofitsparts.Thesafetyconceptofthecontrolunitisvalidonlyinperfect
condions.
• Anydamagedsocket,conneconterminalorcablemustbereplacedimmediatelybyqualiedtechniciansorbyauthorized
service centre.
• Incaseofrepairorreplacementoftheconneconcablesand/orofthedamageddevicesorthatdon’tworkproperly,please
contact the authorizedservicecentre.
• Incorrectorimproperinstallaonmaycausethesystemtomalfunconand/orresultindamagetopeopleand/orproperty.
• Alwaysdisconnectthepowersupplybeforeopeningthecontrolunit.
1.1 Symbols used
Theoperaonswhichcanbedangerousiftheyarenotcarriedoutcorrectlyareindicatedwiththissymbol.
Dangertopersonsduetoelectricity.
Theoperaonswhoseexecuonrequiresqualiedorspecializedstatoavoidanydangerareindicatedwiththissymbol.
Importantinformaonforacorrectinstallaonanduseoftheproduct.

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h5/54
ALL RIGHTS ARE RESERVED ACCORDING TO THE
INTERNATIONAL COPYRIGHT CONVENTIONS,
Thereproduconofanypartofthismanual,inanyform,isforbiddenwithoutthepriorwrien
authorizaonofthemanufacturer.
Thecontentofthisguidecanbemodiedwithoutpriornoce.Greatcarehasbeentakenincollecngand
checkingthedocumentaoncontainedinthismanualtomakeitascompleteandcomprehensibleaspossible.
Nothingcontainedinthismanualcanbeconsideredasawarranty,eitherexpressedorimplied-including,notina
restricveway,thesuitabilitywarrantyforanyspecialpurpose.
Nothingcontainedinthismanualcanbeinterpretedasamodicaonorconrmaonoftheterms
of any purchase contract.
The UCS productshavenotbeenconceivedtoworkinareasatriskofexplosions.Incaseofdamageormalfuncon,the
controlunitsmustnotbeusedunltheCustomerCareTechnicalServicehasrepairedit.
Theinstallerandthemaintenancemanmustknowthecontentofthismanual.Althoughthemainfeaturesoftheequipmentdescribed
inthismanualarenotsubjecttochange,themanufacturerreservestherighttomodifythecomponents,detailsandaccessories
itdeemsnecessarytoimprovetheproductortomeetmanufacturingorcommercialrequirementsatanymeandwithoutbeing
obligedtoupdatethismanualimmediately.
Foranyinformaon,pleasecontact
ucs@ultraflexgroup.it
1.2 Informative letter
WARNINGWARNING
WARNINGWARNING

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h6/54
A
2. PACKING CONTENTS
3. UNPACKING
4. DATA PLATE
Thecontrolunitsaredeliveredinaboxinsidewhichtherearetheusemanualandthefollowingcomponents:
-6plugs(A)
-6xingscrews(B)
-1cabinetopeningkey(C)
-6transparentgaskets(D)
-3“earthing”adhesives(E)
-1gasketfortheupperplate(F)
Themanufacturer’sidencaonandEuropeanDirecveconformityplateislocatedonthecontrolunit.
Severalsafetywarningsareappliedtothecontrolunit;suchwarningsmustbestrictlyfollowedbyeveryonedealingwiththisproduct.
-
1. Remove the control unit from the box.
2. Removeallthecomponentsfromthepackaging.
TheidencaonplateCE/EACislocatedonthelelowerpartofthecontrolunit.
C
EB
D
F
WARNINGWARNING
Manufacturer’sidencaon CE/EACmarking
Model
Electrical features
Part Number
EN12101:10Cercaon
Producondate Serial Number

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h7/54
5. PRODUCT DESCRIPTION
1 Cable inlet plate
2Buerbaeries
3 Electronic board
4Powersupplyconneconterminal
5Cabinetclosingsystem
6Earthingconnecon
7Integratedemergencypushbuon
8Manualopeningpushbuonpanelfornaturalvenlaon
9Conneconofemergencypushbuon
10 Manualopeningconneconofnaturalvenlaon
5
13
6
42
7
8
9
10

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h8/54
Theinstallaonoftheemergencypushbuoniscompulsorybecause,inaddiontoallowingmanualemergencycontrol,italso
providesdisplayoffault/emergencywarnings,andcanbeusedforeasy,remoteRESETTING.
Forthewiringdiagrams,refertopagesfrom49to53.
Thecontrolunitcomeswith2baeriesthatarekeptchargedwhenthemainspowersupplyisavailableand,whenthisisnot
available,theyguaranteea72hourautonomyperiodinstand-bymode,makingitpossibletosllexecuteacompleteemergency
openingcommand,asprescribedbyEN12101-10.
Accessoriesandequipmentconnectedtothecontrolunitmustbechosenamongthoselistedinthefollowingtableanddiagram:
C-SV4A/8AandC-SVIB4A/8Acontrolunitscommandthesmokeandtheheatextraconincaseofreandalsotheyallowdaily
venlaonbyopeningasingleorseveralwindows.Dependingonthedesireduse,thecontrolunitcanbesuppliedin4and8Amp
versionsanditallowstheconneconofawiderangeofsensors,rodactuators,rackactuatorsandchainactuatorsanddierent
accessoriestocompletetheinstallaon.
Thecontrolunitsareequippedwithbuerbaeriesandtheycommand24Vdcactuators.Smokeextraconopeningoccursaer
theenablingofsmokedetectors,emergencypushbuons,recontrolunitsor“BMS-buildingmanagementsystem”systems.
TheemergencypushbuonsareequippedwithLEDsfordisplayingfaultsandmalfunconsofpowersupplyandemergencystatus.
Thecontrolunitalsoallowsnaturalvenlaonbycontrollingautomacallythewindowsdependingonenvironmentalcondions
detectedbythesensorsensuringcomfortandenergysaving.
Themanualcontrolofwindowsanddoorsoccursbymeansofspecicpushbuonsontwoseparateareas.
WARNINGWARNING
N.
1Smokeopcalsensor 36418Q 10 pcs 2poles,sect.0,5-1,5sq.mm,
Lmax 500m
2Emergencypushbuonpanel 42140N 10 pc 7poles,sect.0,5-1,5sq.mm,
Lmax 500m
3Acouscsignallingdevice 40892C 1 pcs 2poles,sect.0,5-1,5sq.mm,
Lmax 500m
4ConneconofBMSsystemor
third-partyreproteconsystem - - 2poles,sect.0,5-1,5sq.mm,
Lmax 500m
5 Wind sensor WS 37185V 1 pc 2poles,sect.0,5-1,5sq.mm,
Lmax 500m
6 Rain sensor RS 40450K 1 pc 4poles,sect.0,5-1,5sq.mm,
Lmax 500m
7 CO2 sensor 41773L 1 pc 2poles,sect.0,5-1,5sq.mm,
Lmax 500m
8 Thermostat TH 40675K 1 pc 3poles,sect.0,5-1,5sq.mm,
Lmax 500m
9Naturalvenlaonpushbuons
(2separateareas)
41019H
(orequivalent) -3poles,sect.0,5-1,5sq.mm,
Lmax 500m
10 Actuators24Vdc(2separatemotor
lines)
See UCS product
catalogue
Dependingonactuator
absorponandcontrol
unitsize
See par. 7.2 “Electrical
connecons”
11 C-SVsmokeextraconcontrolunit See UCS product
catalogue - -
WARNINGWARNING

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h9/54
1
9 9
10 10
10 10
1 5
6
7
8
9 9
4
3
11
FIRE ALARM
SYSTEM
or
BMS
2 2

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h10/54
6. TECHNICAL FEATURES
• ClassDcontrolpanel(controlpanelwithdetectors)accordingtoprEN12101-9:2008.
• Designedforuseinclass1environments,accordingtotheclassicaoncontainedinEN12101-10(clean,indoorenviron-
ments,temperature–5°Cto+40°C).
• Mainspowersupply(forsecondarypowersupply):100-250Vac,50–60Hz.Nominalpowerconsumpon:108W(C-SV4A)-
202W(C-SV8A).Standbypowerconsumpon:lessthan2W(C-SV4A)–lessthan9W(C-SV8A).
• Secondarypowersupplyfromleadbaeries:12V,4,5Ah,inseriesorleadbaeries:12V,4Ah,inseries.Maximuminterrup-
onmewhenswitchingbetweenthetwopowersupplysources:0,2s.
• Maximumcurrentrequiredofthebaeries,whentheprimarypowersupplyisunavailable:4,05Aor8,05Adependingon
the version.
• Motoroutputs:24Vdc+/-25%.2lines–max2Aor4AeachforC-SV4AandC-SV8Arespecvely.
• Visualsignals:n°3LEDs:GREEN,YELLOW,RED,onboard,fordiagnoscs.
• N°2X24Vdcpolarityinversionmotoroutputs,eachwithamaximumloadof2Aor4AforC-SV4AandC-SV8Arespecvely.2
naturalvenlaonzones,1smokeextraconzone.
• N°1x24Vdcauxiliaryoutput.Thisoutputisdisconnectedautomacallyifablackoutoranemergencyoccurs.Instandbymode,
youmustsubtractthepowerconsumponofthisoutputfromtheavailablepoweronthetwomotoroutputs.
• N°1outputwithclean(NC/NO)switchingcontact,todisplayemergencies(EM.SIG.).
• N°1outputwithclean(NC/NO)switchingcontact,todisplayemergencyclosing(EM.CL.SIG.);
• N°1outputwithclean(NC/NO)switchingcontact,todisplayanomalies/faults(AUX.SIG.).
• Inputforsmokesensors(upto10sensors).
• Inputforemergencypushbuons(upto10pushbuons).
• Inputforemergencysignalfromanyexternalalarmsystem.
• Inputforemergencyclosingcommand.
• AUX1inputdrivenbyanexternalvoltage(24Vdc+/-25%)fortheacvaonofEMERGENCYINTERLOCKcommand(bydefault,
theinputisdisabled).
• 2inputsformanualcontrolofthe2naturalvenlaonzones.
• Thermostatinput,1weathermanagementzone.
• Inputsforwind,rainandCO2sensors,1weathermanagementzone.
• Inputfordisablingweatherfuncons(thermostat,wind,rain,CO2).
ITEMS INCLUDED:
• 2leadbaeries:12V,4,5Ah(*)or2leadbaeries:12V,4Ah(*)(LxHxD:mm.90x100x70–Code40911V);
• Extractableinput/outputconnectorsforeasywiring.
Chargingme:for100%dischargedbaeries,maximum10hours.
6.1 Dimensions
WARNINGWARNING

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h11/54
7. INSTALLATION
7.1 Control panel positioning
3
4
Remove earth cable “A” placed on the
control unit door.
Mark on the wall the position of the
fixingholes.
Drillthewallandxthebox.
Choose adequately the xing system
accordingtothewalltypetowhichthe
controlunitisxed.
Remove plate “B”frombox“C”togainaccesstothexingholes.
For C-SVIB4A/8A version,disconnectconnectors“D” ofthepushbuon
panelandemergencypushbuonpanel.
WARNINGWARNING
1
A
2
B
C
C
D
B

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h12/54
Reposionplate“B”insidebox“C”.
For C-SVIB4A/8Aversion,reposionconnectors“D”ofthepushbuonpanel
andemergencypushbuonpanel.
Reposition earth cable “A” on the
control unit panel.
5
B
C
C
D
B
CONNECTORS ON BOARD
CONNECTORS ON COVER
6
A

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h13/54
7.2 Electrical connections
A=
Thecableminimumcrossseconofeachmotorlinecanbecalculatedaccordingtothefollowingformula:
A = crossseconofthelineinmm²
L = line length in m (from control unit to last
lineactuator)
Ι = totalcurrentabsorbed(A)bythemotorsin-
stalled on the line
ΔU=maximumpermittedvoltagedropinthe
line = 2V
Thecontrolunitissuppliedwiththe(RED)posivecabletothebaerydisconnectedandisolatedbymeansoftape,toavoidthe
baerydischargingcompletelyandbeingdamagedbeforeinstallaon.
Thecontrolunitisedwithquickcouplingterminals,whichallowquick,opmumconnecon
oftheplant’swires.Theterminalsaresuitableforwireswitha0,5to1,5sq.mmsecon(20to
16AWG).
Seethe“ELECTRICALCONNECTIONS”wiringdiagramsinthismanual.
Thecontrolunitcomeswithsomeresistors/capacitorsedontheconnectors,toallowyoutoswitchitonwithoutanydevice
connected,andwithoutanalarmbeingacvatedonthecontrolunititself.
Whenconnecngtheaccessories(smokesensors,pushbuonpanel,actuators),theseresistors/capacitorsmustbemovedas
showninthe“ELECTRICALCONNECTIONS”diagram:
• the10kOhmresistorsontheSMOKEandEMERGENCYBUTTONterminalsmustbemovedasshownindiagram8onpage52.
• the10kOhmresistorsontheEXTALandEMCLterminalsmustbemovedasshownindiagrams6and7onpage51;
• the4,7uFcapacitorsontheMOTOR1andMOTOR2outputsmustbemovedtotheendofthelines,asshowninthediagram
3onpage50,inordertohavecontroloveranyinterrupons/short-circuitsonthecables.
C
WARNINGWARNING
Themotoroutputsterminalscantakewireswitha1,5to4sq.mmsecon(16to11AWG).
2 xLxΙ
50 xΔU

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h14/54
7.3 Calibration
Alltheelectricalconnecons,includingthemainpowersupply,mustreachthecontrolunitthroughthededicatedcover.
Forthatpurpose,proceedasfollows:
7
Removethexingholesfromcover“E”. Drillholesonthecoveraccordingtothe
amount of cables to be connected.
Reposioncover“E”ontheboxequipped
withgasket“F”.
E
8 9
E
F
Connect the power supply cable to terminal “G”.
Connecttheredcabletothebaery.
Oncetheinstallaonhasbeencompletedandallconnecons(includingthoserelatedtothe
baeriesandmainspowersupply)havebeenformed,theyellowLEDwillstaylitonthecon-
trolunit(redandgreedLEDso),toindicatethatcalibraonofthetestcircuitryonthemotor
outputsisrequired.Checkthatthecontrolunitandthemotorsareworkingcorrectly,andthen
pushtheCALbuonontheboard.Ifnoerrors,faults,oremergenciesaredetected,thecontrol
unitwillgointoSTANDBYmode,whichisindicatedbyonlythegreenLEDswitchingonand
stayingon.
10
G

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h15/54
8. USE
8.1 Commands and signals
•
•
WARNINGWARNING
Aerhavingcarriedoutthecalibraon,closethecontrolunitdoorbymeansofthededicatedkeysupplied.
Thecontrolunitconguraonmustbecarriedout/changedonlybyqualiedtechnicianswithadequatetraining.
POTENTIOMETER
FOR WIND
THRESHOLD
SETTING
(seepar.8.4.4)
RESET
(seepar.8.3.6) CALIBRATION
(seepar.7.3)
LED
(seepar.8.1)
DIP-SWITCH
(seepar.8.2)
DIAGNOSTIC
INTERFACE
(seepage17)
WARNINGWARNING

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h16/54
OnthepushbuonpanelandonthecontrolunittherearethreeLEDs-Green,Yellow,andRed-whichworkaccordingtothe
followinglogic:
Logicappliedforthe:
emergency(openingorclosing,indierently): ONFIXED
emergencyinterlock(seepar.8.3.5) ONFLASHING
allothercases: OFF
Logicappliedforthe:
fault ON FIXED
power supply problems ON SINGLE FLASHING
powersupplyproblems+fault ONDOUBLEFLASHING
Logicappliedforthe:
Nofault,primarypowersupplyOKandnoemergency ONFIXED
all other cases OFF
Allthecombinaonsareindicatedbelow:
LED STATUS CONTROL UNIT STATUS
RED GREEN
Fault
No No No No
No No No Yes
x1 No No Yes No
x2 No No Yes Yes
x1 No Yes No No
x2 No Yes No Yes
x1 No Yes Yes No
x2 No Yes Yes Yes
Yes No No No
Yes No No Yes
x1 Yes No Yes No
x2 Yes No Yes Yes
x1 Yes Yes No No
x2 Yes Yes No Yes
x1 Yes Yes Yes No
x2 Yes Yes Yes Yes
x1 Interlock em. No No No
x1 Interlock em. No No Yes
x1 x1 Interlock em. No Yes No
x1 x2 Interlock em. No Yes Yes
x1 x1 Interlock em. Yes No No
x1 x2 Interlock em. Yes No Yes
x1 x1 Interlock em. Yes Yes No
x1 x2 Interlock em. Yes Yes Yes
- o - on -flashing x1=Interlockemergencyx2=Emergencyclosing
Note

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h17/54
8.2 Initial configuration
In INTERLOCK SLAVEmode,AUX1inputisenabledwithemergencyinterlockfunconandEMCLSIGoutputbehavesasa
copyofEMSIG,sothatthecontrolunithastwoseparateemergencysignals(seediagram10onpage53).
In INTERLOCK MASTERmode,themotoroutput2isusedasanemergencyinterlockcommandtotheothercontrolunits
thatareinINTERLOCKSLAVEmode.Therefore,theoutput2isacvatedonlyintheemergencystatus(allthefunconsof
naturalvenlaonaredisabledforzone2)andithasalwaysthesamepolarity(theonecorrespondingtotheopening)(see
wiring10onpage53).
When a fault occurs, the control unit can be interrogated using a diagnoscs cable (code
41853M),whichcanbeconnectedtoaPCandmakesitpossibletorecoverinformaononthe
controlunit’sstatusinreal-me.
Tousethediagnoscscable,seethespecicmanual.
Thecontrolunitconguraonmustbecarriedoutbymeansofdip-switchesandwindsensorpotenometerposionedonthe
board.
Posiondip-switchesandwindthresholdaccordingtothedesiredconguraon.
OFF:actuatorsdriving
OFF:naturalvenlaonbuonsin“dead-
man”mode
OFF: automacclosingonlyincaseof
doubleresengclosetogether
OFF: INTERLOCKSLAVEmodedisabling
OFF: INTERLOCKMASTERmodedisabling
ON: solenoids/electromagnetsdriving
ON: momentaryoperaon
ON: automacclosingaersinglereset
ON: INTERLOCKSLAVEmodeenabling
ON: INTERLOCKMASTERmodeenabling
OFF:repeonofemergencyopencom-
mandinacve(deadlockinacve) ON: repeonofemergencyopencommand
acve(deadlockacve)
1 2 3 4 5 76 8
ON
NOT USED
NOT USED
NOT USED
NOT USED

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h18/54
Ifused,theEXTALinputmustbeconnectedtooneofmorenormallyclosedcontacts
(usuallyrelays),putinserieswithoneanother,andwithasingle10kOhmresistorpo-
sionedattheendoftheline.
Ifnotused,theinputmustbeterminatedwitha10kOhmresistor(seediagram6on
page51).
Openingofoneormorecontact(s)(suchasbreakingofthecable)hasthesameeect
aspushingtheemergencybuon.
TheexternalalarminputcanalsobeconnectedtotheNCcontactontheEMSIGoutputforanotherC-SVcontrolunit,ifyou
wantanemergencystatusofthelaertobepropagatedtothecontrolpanelinvolved(seediagram11onpage53).
8.3.1 Emergency
8.3 Commands for smoke extraction
Thecontrolunitcanenterinemergencymodefollowing:
• SignalfromaSmokesensor
• HoldingtheEmergencyOpenBuon(NCcontact)downforatleast0,5seconds(lteringnecessarytoreducetheriskoffalse
alarms).
• ReceivingofanalarmfromanexternalsourceviatheEXTALterminal.Thecontrolunitcanbeconnected,forexample,toan
externalredeteconsystem.
Whenthecontrolunitisinemergencymode,theredLEDstaysonandthemanual,weather,thermostatandCO2sensorfuncons
are disabled. The control unit sends the motors an open command for 3 minutes. If the “deadlock” funconisenabled(default
seng),thecommandisrepeatedwith2minutepausesbetweeneachrepeon,foratotalmeof30minutes.
Insolenoidvalvepilongmodethemeschange:thecommandonlylasts3secondsandisrepeatedat10secondintervals,fora
totalmeoftwominutes.
Oncethecondionsthatcausedthealarmcease,thecontrolunitstaysinemergencystatusunlaresetcommandisgiven.
8.3.2 EM SIG
8.3.3 EM CL SIG
8.3.4 AUX SIG
Thisisacleancontactoutputforsignallinganalarmstatusofthecontrolunittoexternalde-
vices.Whenthecontrolunitgoesintoalarmmode(duetoanemergencysignalcomingfrom
smokesensors,theemergencybuon,oranexternalsource),thecontactswitchesasshown
indiagram9onpage52.
Thecontactstaysintheswitchedstateunlthealarmceases,andthecontrolunitisreset.
ItworksexactlylikeEMSIG,butbydefaultitisacvatedonlyintheEMERGENCYCLOSING
status signalling the intervenon of the Fire Brigade or authorized personnel on EM CL
command.
Ontheotherhand,ifthecontrolunitisconguredinINTERLOCKSLAVEmode(seedip-switch
conguraonpar.8.2),theoutputbehavesasanexactcopyoftheEMSIGoutput,sothatthe
controlunithastwoseparatecleancontactswhichsignaltheemergencystatus.
CleancontactswitchingNCtoNOincaseoffaults.
ON
OFF
ON
OFF
ON
OFF
ON
OFF

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h19/54
Manualoperaonrequiresthepresenceoftwomomentarypushbuons,oneforeachofthe
twonaturalvenlaonzones,withthreecontacts:common,openandclose(seediagram4
onpage50).
Themanualcommandsaredisabledifanemergency,weather,thermostatorCO2signalhas
beenacvated.Thecontrolunitcanbeconguredsothatthemanualcommandsworkonan
impulsebasis(bypushingthebuonandreleasingitwithin1second),or“deadman”basis
(thecommandremainsacveforaslongasthebuonishelddown).Tochoosethetypeof
operaon,seetheparagraph8.2“INITIALCONFIGURATION”.
1.
Anopeningcommandsenttotheactuatorbymanualcommands,doesnotresultinanytype
ofsignal.
Theopencommandceases:
a.Whenthemaximumstrokemeof180secondsisreached(impulseoperaon)orwhenthe
manualbuonisreleased(personpresentoperaon).
b.Whentheresetbuonispushed(thedrivestops).
c.Impulseoperaon:thedrivestopswhentheclosebuonispushedandreleasedwithin1second.
d.Whenanemergencyofweathereventoccurs(dependingonthesituaon,thedrivechangesdireconorexecutesemergency
opening/closing).
TheEMERGENCYINTERLOCKstatusisacvatedbysupplying24Vdc+/-25%externalvoltage
totheAUX1input(forexample,comingfromthemotoroutputofanothercontrolunitC-SV)
anditissignalledbyaflashingredLED.ItworksonlyifthecontrolunitisconguredinINTER-
LOCKSLAVEmode(seedip-switchconguraonpar.8.2)andifthecontrolunitisnotalready
inemergencystatus.
ThecontrolunitentersintheEMERGENCYINTERLOCKstatus2secondsaertheenablingof
AUX1inputanditremainsinthisstatusunlaRESETcommandisgiven;thecontrolunitgoes
into standby mode.
WhenthecontrolunitisinEMERGENCYINTERLOCKstatus,itgivesaclosingcommandtothemotorsanditignoresanyemergency
command(seediagram10onpage53).
8.3.5 Emergency interlock
8.3.6 Reset
8.3.7 Emergency closing
8.4.1 Manual natural ventilation commands
8.4 Commands for natural ventilation
ON
OFF
ON
OFF
Theresetcommandcanbeacvatedusingtheemergencypushbuonor(duringinstallaon
/maintenance/tesng)directlyonthecontrolunit’selectronicboard.Thiscontrolworks
onlywhenthepushbuonisreleased.
Resengallowsthecontrolunittoexittheemergencysituaon,providedtheeventthat
gaverisetothealarmhasceased.Duringtheresetphase(about1second)allthreeLEDs(red,
yellowandgreen)stayon,makingitpossibletovisuallycheckthattheyareactuallyworking.
Inthefactorysengs,thedoublepressingoftheRESETbuoncommandsthewindowsto
close(seesecon8.2).
TheEM CLinput is usedtosend an emergencyclosing command. This is used in some
countriestosuocateflamesandfacilitatetheFireBrigade’sacons,oncethebuildinghas
been evacuated.
It must be terminated with a 10 kOhm resistor.
Whenused,itmustbeconnectedtooneormoremanualcontrolpoints(normallyopen
contacts)inparallelwithoneanother,eachwitha1kOhmresistorinserieswithit.
Ashort-circuitorbreakinthecableisindicatedasafaultonthecontrolunit,anddoesnotinfluencetheotherfuncons.
ON
OFF
ON
OFF
Venlaonpushbuonpanel

Doc. 85588U - Rev. 22/10/2020
USER MANUALUSER MANUAL
ENEN
Drw. 32367/h20/54
WerecommendngaswitchontheCO2sensortoenableanddisableit.
TheCO2sensorcommandslapseinthefollowingcondions:
a. fordisablingtheweatherfunconsbymeansofadedicatedswitch;
b.Whenanemergencyorweathereventoccurs(dependingonthesituaon,thecommandis
invertedorleinthestateitwasin).
8.4.2 Thermostat
8.4.3 CO2 sensor
Whenthe actuatoris stopped,toselect the new direconofmovement,simply
push and release within 1 second thepushbuonthatrelatestothenewacon
required.
NOTE
VENTILATION
ZONE 1
CLOSING OF
VENTILATION
ZONE 1
VENTILATION
ZONE 2
CLOSING OF
VENTILATION
ZONE 2
2. CLOSING
Aclosingcommandsenttotheactuatorbymanualcommands,doesnotresultinanytypeofsignal.
Theclosecommandceases:
a. Whenthemaximumstrokemeof180secondsisreached(impulseoperaon)orwhenthemanualbuonisreleased
(deadmanoperaon).
b. Whentheresetbuonispushed(thedrivecommandends).
c. Impulseoperaon:thedrivestopswhentheopenbuonispushedandreleasedwithin1second.
d. fortheoccurrenceofanemergencyorweatherevent(asthecasemaybe,thedrivechangesitsdireconorperformsan
emergencyopening/closing)
ON
OFF
Youcanconnectathermostatwhichsendsanopenorclosesignaltothecontrolunit,accord-
ingtothetemperaturethresholdset(seediagram5onpage50).
Werecommendngaswitchonthethermostattoenableanddisableit.
Thethermostatcommandslapseinthefollowingcondions:
a. fordisablingtheweatherfunconsbymeansofadedicatedswitch;
b.Whenanemergencyorweatheror CO2eventoccurs(dependingonthesituaon,thecom-
mandisinvertedorleinthestateitwasin).
Thermostat TH
CO2 sensor
YoucanconnectaCO2sensorwhichsendsanopensignaltothecontrolunit,ifthethreshold
setforthepresenceofcarbondioxideisexceeded(seediagram5onpage50).
ON
OFF
This manual suits for next models
3